LG DLGY1702V, DLEY1701W, DLEY1701V Owner’s Manual

Life's Good
{:ii({ii>
DR
Please read this owner's manual thoroughly before operating and keep it handy for reference at all times,
DLEY1701 _ DLGY1702 _
IIFII]l]llllllt!1
P/No. : 3828EL2001Q
2 TABLE OF CONTENTS
TABLE OF CONTENTS
3 IMPORTANT SAFETY INSTRUCTIONS
3 WHAT TO DO IF YOU SMELL GAS 4 BASIC SAFETY PRECAUTIONS
4 CALIFORNIA SAFE DRINKING WATER AND
TOXIC ENFORCEMENT ACT
5 GROUNDING INSTRUCTIONS 5 SAFETY INSTRUCTIONS FOR INSTALLA]ION
7 SAFETY INSTRUCTIONS FOR CONNECTING
ELECTRICITY
8 PRODUCT FEATURES
9 INTRODUCING YOUR DRYER
9 Parts 9 Accessories 10 Control Panel Features
11 Display
12 INSTALLATION INSTRUCTIONS
12 Preview Installation Order 13 Installation Location Requirements
13 Clearances 14 Leveling the Dryer
15 Reversing the Door 16 Installing the Side Vent Kit 17 Venting the Dryer 19 Connecting inlet Hose 20 Connecting Gas Dryers 22 Connecting Electric Dryers 27 Special Requirements for Manufactured or
Mobile Homes
27 Final Installation Check 28 Installation °rest (Duct Check)
30 HOW TO USE
30 Operating the Dryer 31 Cycle Guide 32 Sorting Load 32 Loading the Dryer 32 Check the Lint Filter Before Every Load 33 Cycle Settings and Options 34 Special Functions 34 Custom Program
34 Steam Functions
3S MAINTENANCE
35 Regular Cleaning
36 TROUBLESHOOTING
36 Before Calling for Service
38 SPECIFICATIONS
39 USING SMART DIAGNOSIS TM
40 WARRANTY
IMPORTANT SAFETY INSTRUCTIONS 3
IMPORTANT SAFETY INSTRUCTIONS
READ ALL INSTRUCTIONS BEFORE USE
_WARNING
For your safety, the information in this manual must be followed to minimize the risk of fire or explosion, electric shock, or to prevent property damage, injury to persons, or death.
Your safety and the safety of others is very important.
We have provided many important safety messages in this manual and on your appliance, Always read and obey all safety messages,
This is the safety alert symbol, This symbol alerts you to potential hazards that can kill or hurt you and others.
All safety messages will follow the safety alert symbol and either the word DANGER, WARNING, or CAUTION, These words mean:
_DANGER
You will be killed or seriously injured if you don't immediately follow instructions,
_WARNING
You can be killed or seriously injured if you don't follow instructions,
f_CAUTION
You may be slightly injured or cause damage to the product if you do not follow instructions, All safety messages will tell you what the potential hazard is, tell you how to reduce the chance of injury, and tell
you what can happen if the instructions are not followed,
k
Do not install a clothes dryer with flexible plastic venting materials. If flexible metal (foil type) duct is installed, it must be of a specific type identified by the appliance manufacturer as suitable for use with
clothes dryers. Flexible venting materials are known to collapse, be easily crushed, and trap lint. These conditions will obstruct clothes dryer airflow and increase the rise of fire.
Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this appliance or any other appliances.
installation and service must be performed by a qualified installer, service agency, or the gas supplier.
Install the clothes dryer according to the manufacturer's instructions and local codes.
Save these instructions.
WHAT TO DO IF YOU SMELL GAS:
1. Do not try to light a match or cigarette, or turn on any gas or electrical appliance.
2. Do not touch any electrical switches. Do not use any phone in your building.
3. Clear the room, building, or area of all occupants.
4. Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's instructions
carefully.
5. If you cannot reach your gas supplier, call the fire department.
_WARN ING:This product contains chemicals known to the State of California to cause cancer and birth defects or other reproductive harm. Wash hands after handlin 9.
4 IMPORTANT SAFETY INSTRUCTIONS
IMPORTANT SAFETY INSTRUCTIONS
READ ALL INSTRUCTIONS BEFORE USE
_WARNING
For your safety, the information in this manual must be followed to minimize the risk of fire or explosion, electric shock, or to prevent property damage, injury to persons, or death,
BASIC SAFETY PRECAUTIONS
_WARNING
To reduce the risk of fire, electric shock, or injury to persons when using this appliance, follow basic precautions, including the following:
Read all instructions before using the dryer.
Before use, the dryer must be properly installed as described in this manual.
Do not place items exposed to cooking oils in your dryer, items contaminated with cooking oils may
contribute to a chemical reaction that could cause
a Bad to catch fire.
Do not dry articles that have been previously cleaned in, washed in, soaked in, or spotted with gasoline, dry-
cleaning solvents, or other flammable or explosive substances as they give off vapors that could ignite or
explode,
Do not reach into the dryer if the drum or any other part ismoving.
Do not repair or replace any part of the dryer or attempt any servicing unless specifically
recommended in this owner's manual or in published user-repair instructions that you understand and have
the skills to carry out.
Do not tamper with controls.
Before the dryer is removed from service or discarded, remove the door to the drying compartment,
. Do not allow children to play on or in the dryer. Close
supervision of children is necessary when the dryer is
used near children,
. Do not use fabric softeners or products to eliminate
static unless recommended by the manufacturer of the fabric softener or product,
. Do not use heat to dry articJes containing foam
rubber or similarly textured rubber-like materials.
. Keep area around the exhaust opening and adjacent
surrounding areas free from the accumulation of lint, dust, and dirt.
. The interior of the dryer and exhaust vent should be
cleaned periodically by qualified service personnel.
. Do not install or store the dryer where it will be
exposed to the weather.
. Always check the inside of the dryer for foreign
objects,
. Clean lint screen before or after each load, . Do not store plastic, paper, or clothing that may
burn or melt on top of the dryer during operation.
CALIFORNIA SAFE DRINI(IN6 WATER AND TOXIC ENFORCEMENT ACT
This act requires the governor of California to publish a list of substances known to the state to cause cancer, birth defects, or other reproductive harm and requires businesses to warn customers of potential exposure to such
substances.
Gas appliances can cause minor exposure to four of these substances, namely benzene, carbon monoxide, formaldehyde, and soot, caused primarily by the incomplete combustion of natural gas or LP fuels,
Properly adjusted dryers will minimize incomplete combustion, Exposure to these substances can be minimized further by properly venting the dryer to the outdoors,
IMPORTANT SAFETY INSTRUCTIONS 5
IMPORTANT SAFETY INSTRUCTIONS
READ ALL INSTRUCTIONS BEFORE USE
_WARNING
For your safety, the information in this manual must be followed to minimize the risk of fire or explosion, electric shock, or to prevent property damage, injury to persons, or death.
GROUNDING iNSTRUCTiONS
This appliance must be grounded. In the event of malfunction or breakdown, grounding will reduce
the risk of electric shock by providing a path of least resistance for electric current. This appliance must be
equipped with a cord having an equipment-grounding conductor and a grounding plug. The plug must be
plugged into an appropriate outlet that is properly installed and grounded in accordance with all local codes and ordinances.
_WARNING
Improper connection of the equipment-grounding conductor can result in a risk of electric shock. Check with a qualified electrician or service person if you are in doubt that the appliance is properly grounded.
SAFETY iNSTRUCTiONS FOR iNSTALLATiON
Do not modify the plug provided with the appliance. If it will not fit the outlet, have a proper outlet installed by
a qualified electrician. This appliance must be connected to a grounded metal,
)ermanent wiring system or an equipment-grounding
conductor must be run with the circuit conductors and connected to the equipment-grounding terminal or
lead on the appliance. Electric shock can result if the dryer is not properly
grounded.
_WARNING
To reduce the risk of fire, electric shock, or injury to persons when using this appliance, follow basic precautions, including the following:
Properly ground dryer to conform with all governing codes and ordinances. Follow details in
the installation instructions. Electric shock can result if the dryer is not properly grounded.
Before use, the dryer must be properly installed as described in this manual. Electric shock can result if
the dryer is not properly grounded.
install and store the dryer where it will not be exposed to temperatures below freezing or
exposed to the weather.
Aft repairs and servicing must be performed by an authorized servicer unless specifically
recommended in this owner's manual. Use only
authorized factory parts. Failure to follow this warning can cause serious injury, fire, electric shock, or death.
To reduce the risk of electric shock, do not install the dryer in humid spaces. Failure to follow this
warning can cause serious injury, fire, electric shock, or death.
Connect to a properly rated, protected, and sized power circuit to avoid electrical overload. Improper
power circuit can melt, creating electric shock and/or fire hazard.
Remove all packing items and dispose of all
shipping materiak properly. Failure to do so can
result in death, explosion, fire, or burns.
Place dryer at least 18 inches above the floor for
a garage installation. Failure to do so can result in
death, explosion, fire, or burns.
Keep aJJpackaging from chffdren. Packaging material can be dangerous for children. There is a risk
of suffocation.
Do not install near another source of heat such as
a stove, cooking oven. Failure to do so can cause deform, smoke and fire.
Do not place candles, smoking materials, or other
flammables on top of the product. Dripping wax,
smoke, or fire can result.
Remove all protective vinyl film from the product. Failure to do so can cause product damage, smoke or
fi re.
6 IMPORTANTSAFETYINSTRUCTIONS
IMPORTANT SAFETY INSTRUCTIONS
READ ALL INSTRUCTIONS BEFORE USE
_WARNING
For your safety, the information in this manual must be followed to minimize the risk of fire or explosion, electric shock, or to prevent property damage, injury to persons, or death.
SAFETY iNSTRUCTiONS FOR iNSTALLATiON
_WARNING
To reduce the risk of injury to persons, follow all industry recommended safety procedures including the use of long sleeved gloves and safety glasses. Failure to follow all of the safety warnings in this manual could result in property damage, injury to persons, or death.
Exhaust/Ducting:
Gas dryers MUST be exhausted to the outside. Failure to follow these instructions can result in fire or
death.
The dryer exhaust system must be exhausted to the outside of the dwelling. If the dryer is not
exhausted outdoors, some fine lint and large amounts of moisture will be expelled into the
laundry area. An accumulation of lint in any area of the home can create a health and fire hazard.
Use only rigid metal or flexible metal 4-inch diameter ductwork inside the dryer cabinet or for
exhausting to the outside. Use of plastic or other combustible ductwork can cause a fire. Punctured
ductwork can cause a fire if it collapses or becomes otherwise restricted in use or during installation.
Ductwork is not provided with the dryer, and you should obtain the necessary ductwork locally. The
end cap should have hinged dampers to prevent
backdraff when the dryer is not in use. Failure to follow these instructions can result in fire or death.
. The exhaust duct must be 4 inches (10.2 cm} in
diameter with no obstructions. The exhaust duct should be kept as short as possible. Make sure
to dean any old ducts before installing your new dryer. Failure to follow these instructions can result in
fire or death.
. Rigid or semi-rigid metal ducting is recommended
for use between the dryer and the wall. In special
installations when it is impossible to make a
connection with the above recommendations, a UL-
listed flexible metal transition duct may be used between the dryer and wall connection only. The use of this ducting will affect drying time. Failure to
follow these instructions can result in fire or death.
. DO NOT use sheet metal screws or other fasteners
which extend into the duct that could catch lint and
reduce the efficiency of the exhaust system, Secu re
all joints with duct tape. For complete details, follow the Installation Instructions. Failure to follow these
instructions can result in fire or death.
IMPORTANT SAFETY INSTRUCTIONS 7
IMPORTANT SAFETY INSTRUCTIONS
READ ALL INSTRUCTIONS BEFORE USE
_WARNING
For your safety, the information in this manual must be followed to minimize the risk of fire or explosion, electric shock, or to prevent property damage, injury to persons, or death.
SAFETY iNSTRUCTiONS FOR CONNECTING ELECTRiCiTY
_WARNING
To reduce the risk of fire, electric shock, or injury to persons when using this appliance, follow basic precautions,
including the following:
Do not, under any circumstances, cut or remove the ground prong from the power cord, To prevent
injury to persons or damage to the dryer, the electrical power cord must be plugged into a properly grounded outlet.
For personal safety, this dryer must be properly grounded. Failure to do so can result in electric shock
or injury.
Refer to the installation instructions in this manual for specific electrical requirements for your model.
Failure to follow these instructions can create an electric shock hazard and/or a fire hazard.
This dryer must be plugged into a properly grounded outlet. Electric shock can result if the
dryer is not properly grounded. Have the wall outlet and circuit checked by a qualified electrician
to make sure the outlet is properly grounded. Failure to follow these instructions can create an electric shock hazard and/or a fire hazard.
. The dryer should always be plugged into its own
individual electrical outlet which has a voltage rating that matches the rating plate. This provides
sparkling performance and also prevents overloading house wiring circuits which could cause a fire hazard
from overheated wires.
. Never unplug your dryer by pulling on the power
cord. Always grip plug firmly and pull straight out
from the outlet. The power cord can be damaged,
resulting in a risk of fire and electric shock.
. Repair or replace immediately all power cords that
have become frayed or otherwise damaged, Do not use a cord that shows cracks or abrasion damage
along its length or at either end. The power cord can
melt, creating an electric shock and/or fire hazard.
. When installing or moving the dryer, be careful not
to pinch, crush, or damage the power cord. This will
prevent injury and prevent damage to the dryer from
fire and electric shock.
SAVE THESE INSTRUCTIONS
8 PRODUCT FEATURES
PRODUCT FEATURES
An entire selection of user-friendly functions make operating the dryer easy.
The wide-opening door provides easy access for loading and unloading. The door hinge can be reversed to adjust for installation location.
LG'ssteam technology allows you to inject fabrics with a swirling jet of steam to refresh clothes, reduce static,
and make ironing easier. Simply select the Steam Fresh TM cycle or Wrinkle Care cycle.
The Flow Sense TM duct blockage sensing system detects and alerts you to restrictions in the installed household
ductwork that reduce exhaust airflow through the dryer. If you seethe alert: Clean or repair the ducts to remove the restrictions. Keep your ducts clean to help increase efficiency and reduce long drying times caused
by blocked ducts.
Should you experience any technical difficulty with your dryer, it has the capability of transmitting data via your telephone to the Customer Information Center. The call center agent records the data transmitted from your machine and uses it to analyze the issue, providing a fast and effective diagnosis (refer to page 3g).
_ rotocol P154
Sanitization Performance of Residential Clothes dryer
INTRODUCING YOUR DRYER
Parts
INTRODUCING YOUR DRYER 9
Reversible
Control
panel
Leveling ....................................... location Exhaust
feet (Gas models) duct
door
Lint filter connection
Terminal -
block
access panel
(Electric models)
Gas -
Accessories
Induded accessories
Y connector Hose Drying rack
J
outlet
(sold separately)
383EELgOO1B
location
(Gas
models)
Water inlet valve
Side vent kit
Kit No.
f@ NOTE
Contact LG Customer Service at 1-800-243-0000 (1-888-542-2623 in Canada) if any accessories are missing. For your safety and for extended product life, use only authorized components. The manufacturer is not responsible for product malfunction or accidents caused by the use of separately purchased unauthorized components or parts.
The images in this owner's manual may be different from the actual components and accessories, and are
subject to change by the manufacturer without prior notice for product improvement purposes. .,
10 INTRODUCINGYOURDRYER
Confrol Panel F'eafures
Following are instructions for starting and using your new dryer. Please refer to specific sections of this manual for more detailed information.
_WARNING
To reduce the risk of fire, electric shock, or injury to persons, read this entire manual, including the Important Safety Instructions, before operating this dryer.
POWER ON/OFF BUTTON
Press to turn the dryer ON. Press again to turn
the dryer OFF.
o@NOTE
ressing the ON/OFF button during a cycle will
ncel that cycle and any load settings will belost.
k
Q CYCLEBUTTONS
Press the Cycle button repeatedly to scroll through the cycle selections until the desired cycle is selected. The standard presets for the selected cycle will be shown in the display. On MANUAL DRY cycles, these settings can be adjusted using the cycle setting buttons anytime before starting the cycle.
START/PAUSEBUTTON
Press this button to start the selected cycle. If the dryer is running, use this button to pause the cycle without losing the current settings.
.--@NOTE
If you do not press the START/PAUSEbutton to
resume a cycle within 4 minutes, the dryer turns
/ off automatically.
MORE TIME/LESSTIME BUTTONS
®
Use these buttons with tile Time Dry and other MANUAL DRY cycles to adjust the drying time.
Press the More Time button to increase the selected manual cycle time by one minute;
press LessTime to decrease the cycle time by one minute.
CYCLE SETTING BUTTONS
O
Use these buttons to select the desired cycle settings for the selected cycle. The current settings are shown in the display. Press the button for that option to select other settings.
TIME AND STATUSDISPLAY
O
The display shows the settings, estimated time remaining, options, and status messages for your dryer.
OPTION BUTTONS
®
The option buttons allow you to select additional cycle options. Certain buttons also allow you to activate special functions by pressing and holding the button for 3 seconds.
STEAM FUNCTIONS
@
LG's steam technology allows you to inject fabrics with a swirling jet of steam to refresh clothes, reduce static, and make ironing easier. Simply select the Steam FreshTM cycle or Wrinkle Free cycle.
INTRODUCINGYOURDRYER"1"1
Display
Following are instructions for starting and using your new dryer. Please refer to specific sections of this manual for more detailed information.
_WARNING
To reduce the risk of fire, electric shock, or injury to persons, read this entire manual, including the Important Safety Instructions, before operating this dryer,
Q ESTIMATED TIME REMAINING
This display shows tile estimated time remaining
for SENSOR DRYcycles or the actual time
remaining for Time Dry or MANUAL DRY cycles.
S _ NOTE
IThe cycle time on SENSORDRYcycles may I fluctuate as the dryer recalculates drying time for
optimal results.
_) CYCLECOMPLETION INDICATOR
WITH CHECK FILTER REMINDER
This portion of the display shows which stage of the drying cycle is currently underway (Clean
Filter, Drying, Cooling).
CHILD LOCK INDICATOR When Child Lock is set, the Child Lock indicator
will appear and all buttons are disabled except
the POWER button. This prevents children from changing settings while the dryer is operating.
CLEAN FILTERREMINDER
The display will show Clean Filter when tile dryer is turned on as a reminder to check the
filter. It turns off when the START/PAUSE button is pressed.
CUSTOM PROGRAM If you have aspecial combination of settings
that you use frequently, you can save these settings as a Custom Program.
Flow Sense TM DUCT BLOCKAGE
SENSING SYSTEM INDICATOR The Flow Sense"_duct blockage sensing
system detects and alerts you to blockages in the ductwork that reduce exhaust flow from
the dryer. Maintaining a clean exhaust system improves operating efficiency and helps minimize service calls, saving your money.
12 INSTALLAiTIONINSTRUCTIONS
INSTALLATION INSTRUCTIONS
PREVIEW INSTALLATION ORDER
Checking and
choosing the proper
location
Connecting the inlet hose Connecting gas
Plugging in the power cord and
grounding
Leveling the dryer Venting the dryer
Press and hold
installation test
(Refer to page 28,)
dryers
Connecting electric
d rye rs
Test run
INSTALLAiTION INSTRUCTIONS ]3
Insfallafion Locafion Requiremenfs
_WARNING
Read all installation instructions completely before installing and operating your dryer! It isimportant that you review this entire manual before installing and using your dryer. Detailed instructions concerning electrical connections, gas connections, and exhaust requirements are provided on the following pages.
° A location that allows for proper exhaust installation, A
gas dryer must be exhausted to the outdoors, See Venting the dryer,
A grounded electrical outlet located within 2 ft. (61 cm) of either side of the dryer, See Connecting
electric dryers,
Do not operate your dryer at temperatures below 45°F (7°C). At lower temperatures, the dryer might not shut off at the end of an automatic cycle. This can result in longer drying times, The dryer must not be installed or stored in
an area where it will be exposed to water and/or weather, Check code requirements. Some codes limit, or do not permit, installation of the dryer in garages, closets, mobile homes or sleeping quarters, Contact your local building
inspector,
'i NOTE
level floor with a maximum slope of 1 inch (2,5 cm) under entire dryer, If slope is greater than 1 inch (2.5 cm),
install the Extended Dryer Feet Kit. Clothes may not tumble properly, and automatic sensor cycles may not
perate correctly if dryer is not level.
or a garage installation, you will need to place the dryer at least 18 inches (46 cm) above the floor, If using a
pedestal, you will need 18 inches (46 cm) to the bottom of the dryer.
Clearances
. A sturdy floor to support the total dryer weight of 200
Ibs (90.7 kg). The combined weight of a companion
appliance should also be considered,
. No other fuel-burning appliance can be installed in the
same closet as a dryer,
_14" rTa_
21 / _(35 6 cr]
(7_4 _-',) (_27c,',)
1"_11_ 27_11_ 1"
(254 ore) (686 ore) (2.54 crf]) 3" Closet Door Vent
(7.6cm)
_/SS
(76 cm) Requirements
INSTALLATION SPACING FOR RECESSED AREA OR CLOSET INSTALLATION
The following spacing dimensions are recommended for this dryer, This dryer has been tested for spacing of
1 inches(2,S4cm) clearance on the sides and rear, Recommended spacing should be considered for the following
reasons:
Additional spacing should be considered for ease of installation and servicing.
Additional clearances might be required for wall, door and floor moldings,
. Additional spacing should be considered on all sides
of the dryer to reduce noise transfer,
For closet installation, with a door, minimum ventilation openings in the top and bottom of the
door are required, Louvered doors with equivalent ventilation openings are acceptable.
. Companion appliance spacing should also be
considered,
here should be at least a little space around the dryer (or any other appliance) to eliminate the transfer of ibration from one to the other, Too much vibration, it could cause them to make noise or touch each other
@ NOTE 1
using paint damage and making even more noise,
14 INSTALLATION INSTRUCTIONS
Clearances (COnt.)
RECOMMENDED INSTALLATION SPACING FOR CABINET INSTALLA TION
For cabinet installation with a door, minimum ventilation openings in the top of the cabinet are required.
*Required spacing **For side or bottom venting,
2 inches (5.1 cm) spacing is allowed.
Leveling fhe Dryer
AWARNiNG
To reduce the risk of injury to persons, adhere to all industry recommended safety procedures including
the use of long sleeved gloves and safety glasses. Failure to follow this warning can cause serious injury
or death.
The appliances are heavy, Two or more people are required when installing the dryer. Failure to follow
this warning can cause serious injury or death.
To ensure that the dryer provides optimal drying performance, it must be level. To minimize vibration, noise, and unwanted movemenl, the floor must be a perfectly level, solid surface.
i@NOTE -',
djust the leveling feet only as far as necessary to
vel the dryer. Extending the leveling feet more than
ecessary can cause the dryer to vibrate, J
m
T
_ _I_ 1,__1i_ 27,,_ i_ 1,,
5"* 281S/16" 1"*
(12.7 cm) (73.4 cm) (2.5 cm) (2.54 cm) (68.6 cm) (2.54cm)
. All four leveling feet must rest solidly on the floor.
Gently push on the top corners of the dryer to make sure that the dryer does not rock from corner to corner.
If you are installing the dryer on the optional pedestal,
you must use the leveling feet on the pedestal to
level the dryer, The dryer leveling feet should be fully retracted,
2. Use an adjustable wrench to turn the leveling feet, Turn clockwise to raise the dryer or counterclockwise to lower it. Raise or lower the leveling feet until dryer
is level from side to side and front to back.
Make sure that all 4 leveling feet are in firm contact with
the floor.
I
1,Position the dryer in the final location. Place a level
across the top of the dryer,
_Leveling Feet
Reversing the Door
INSTALLATIONINSTRUCTIONS"1.5
_WARNING
To avoid damage to the dryer or the door, support the door with a stool or box that fits under the
door, or have an assistant support the weight of the
door,
Avoid dropping the door to avoid damage to the door or the floor.
THE DRYER DOOR ISVERY LARGE AND HEAVY. Failure to follow the instructions below can result in damage to
the dryer, property damage or injury to persons.
1.Open the door and remove the two plastic hole caps on the catch side by gently prying up with a flat blade
screwdriver. Save these for step 6.
,' Hole cap
2. While supporting the door, remove the 4 screws, two from each hinge. Set the door aside face down on a
protected surface to prevent damage to the door or the work surface.
4. Remove the 4 screws securing the hinges to the door frame. Remove the two plastic cover caps. Reinstall
the hinges and cover caps on the opposite sides from which they were removed.
I
S. With the hinges and cover caps in the new locations,
remount the inner door frame onto the outer door frame with the screws removed in step 3 above.
m m m
6. Reinstall the door with the screws from steps 1,2.
I
|
3. With the door on aprotected surface, remove the 12 screws on each side of the door and lift off the inner
door frame using a flat blade screwdriver. Remove the latch hook and blank and move them to the opposite
side.
6. Test the swing of the door to make sure the hinges
and latch are properly aligned and that the door closes and latches correctly.
16 INSTALLAiTION INSTRUCTIONS
Insfalling fhe Side Venf Kif
_WARNING
Use a heavy metal vent.
Do not use plastk or thin foil duct.
Clean old ducts before installing this dryer.
To reduce the risk of injury to persons, adhere to all
industry recommended safety procedures including the use of ]onej sleeved g[oves and safety glasses.
Failure to follow all of the safety warnings in this
manual could result in property damage, injury to persons, or death.
Your new dryer is shipped to vent to the rear. It can also be configured to vent to the bottom or side
(right-side venting is not available on gas models). An adapter kit, part number 383EELgOO1B, may be
purchased from your LG retailer. This kit contains the necessary duct components to change the dryer vent
location.
1.Remove the rear exhaust duct retaining screw. Pull out the exhaust duct.
Retaining Screw
3.Preassemble a 4 inches (10.2 cm) elbow to the next 4-inches (10.2 cm) duct section, and secure all joints
with duct tape. Be sure that the male end of the elbow faces AWAY from the dryer. Insert the elbow/duct assembly through the side opening and press it onto the adapter duct. Secure in place with duct tape. Be sure that the male end of the duct protrudes 1V2 inches (3.8 cm) to connect the remaining ductwork Attach cover plate to the back of the dryer with
included screw.
Cover Plate
OPTION 2: BOTTOM VENTING
2. Press the adapter duct onto the blower housing and secure to the base of the dryer as shown.
Adapter
OPTION !: SIDE VENTING
2. Press the tabs on the knockout and carefully remove the knockout for the desired vent opening (right- side venting is not available on gas models). Press the adapter duct onto the blower housing and secure to the base of the dryer as shown.
Bracket
Bracket
3.Insert the 4 inches (10.2 cm) elbow through the rear opening and press it onto the adapter duct. Be sure that the male end of the elbow faces down through
hole in the bottom of the dryer. Secure in place with duct tape.
Attach the cover plate to the back of the dryer with included screw.
Cover, Plate
INSTALLAiTIONINSTRUCTIONS17
Venting the Dryer
_WARNING
To reduce the risk of fire, electric shock, or injury to persons when using this appliance, follow basic precautions, including the following:
Do not crush or collapse ductwork. Failure to follow these instructions can result in fire or death.
Do not allow ductwork to rest on or contact sharp objects. Failure to follow these instructions can result
in fire or death.
if connecting to existing ductwork, make sure it is suitable and clean before installing the dryer.
Failure to follow these instructions can result in fire or death.
Venting must conform to local building codes. Failure to follow these instructions can result in fire or
death.
Gas dryers MUST exhaust to the outdoors. Failure to follow these instructions can result in fire or
death.
Use only 4-inch (10,2 cm) rigid or flexible metal ductwork inside the dryer cabinet and for venting
outside. Failure to follow these instructions can result in fire or death.
To reduce the risk of fire, combustion, or accumulation of combustible gases, DO NOT
exhaust dryer air into an enclosed and unventilated area, such as an attic, wall, ceiling, crawl space,
chimney, gas vent, or concealed space of a building. Failure to follow these instructions can result
in fire or death.
To reduce the risk of fire, DO NOT exhaust the dryer with plastic or thin foil ducting.
Failure to follow these instructions can result in fire or death.
The exhaust duct must be 4 inches (10.2 cm) in diameter with no obstructions. The exhaust duct
should be kept as short as possible. Make sure to clean any old ducts before installing your new dryer. Failure to follow these instructions can result in
fire or death.
. Rigid or semirigid metal ducting is recommended
for use between the dryer and the wall. In special
installations when it is impossible to make a
connection with the above recommendations, a
UL-Jisted flexible metal transition duct may be used between the dryer and wall connection only. The
use of this ducting will affect drying time. Failure to
follow these instructions can result in fire or death.
. DO NOT use sheet metal screws or other fasteners
which extend into the duct that could catch lint and
reduce the efficiency of the exhaust system. Secure
all joints with duct tape. Failure to follow these
instructions can result in fire or death.
. To maximize operating results, please observe
the duct length limitations noted in the chart next
page. Failure to follow these instructions can result in
fire or death.
. Ductwork is not provided with the dryer. You
should obtain the necessary ductwork locally. The end cap should have hinged dampers to prevent
backdraff when the dryer isnot in use. Failure to
follow these instructions can result in fire or death.
. The total length of flexible metal duct shall not
exceed 8 ft. (2.4 m)
. In Canada, that only those foil-type flexible ducts,
if any, specifically identified for use with the
appliance by the manufacturer shall be used. in the
United States, that only those foil-type flexible ducts, if any. specifically identified for use with the appliance
by the manufacturer and that comply with the Outline
for Clothes Dryer Transition Duct, Subject 21S8A, shall
be used.
18 INSTALLAiTIONINSTRUCTIONS
Venting the Dryer (conf.)
Ductwork
CORRECT VENTING
Recommended
(10 2cm)
(10 2cm)
Use only for
short run
installations
Iie NOTE
educt 6 ft. (1.8 m) for each additional elbow, It is not" "_
commended to use more than four 90° elbows.
Routing and Connecting Ductwork
o
I
2
3
4
o
I
2
3
4
65 ft. (19.8 m)
55 ft. (16.8 m)
47 ft. (14.3 m)
36 ft. (11.0 m)
28 ft. (8.5 m)
55 ft. (16.8 m)
47 ft. (14.3 m)
41 ft. (12.5 m)
30 ft. (9.1 m)
22 ft. (6.7 m)
- @ NOTE
Follow the guidelines below to maximize drying performance and reduce lint buildup and
condensation in the ductwork. Ductwork and fittings are NOT included and must be
purchased separately. . Use 4-inch (10.2 cm) diameter rigid or semirigid
metal ductwork.
. The exhaust duct run should be as short as possible, . Use as few elbow joints as possible,
. The male end of each section of exhaust duct must
point away from the dryer. . Use duct tape on all duct joints. . Insulate ductwork that runs through unheated areas
in order to reduce condensation and lint buildup on
duct surfaces.
. Incorrect or inadequate exhaust systems are not
covered by the dryer warranty. Failures or poor
performance caused by such exhaust systems will
not be covered by the dryer warranty.
INCORRECT VENTING
INSTALLATIONINSTRUCTIONS19
Connecting Inlef Hose
The dryer must be connected to the cold water tap using tile new water supply hose. Do not use old hoses
/ii @N°TE
ater supply pressure must be between 21.8 PSIand 116 PSI (150-800 kPa).
o not strip or cross-thread when connecting inlet hose to the valve.
fthe water supply pressure is more than 800 kPa, a decompression device should be installed.
eriodically check the condition of the hose and replace the hose if necessary. eplace inlet hoses after 5 years of use to reduce the risk of hose failure. ecord hose installation or replacement dates on the hoses for future reference.
1. Check rubber seal in the inlet hose. Two rubber seals are supplied with each inlet hose. They are used for preventing water leaks. Make sure the connection to
the cold water tap istight.
I
2. Check the installation type.
I
Hose
seal
Y connector
I
3.Connect the hose to the dryer.
. Connect the water supply hose to the dryer inlet valve
tightly by hand and then tighten another 2/3 turn with
pliers. Make sure that there are no kinks in the hoses and that
they are not crushed.
s,ori
j_ hose
Y connector
WITH WASHER WITHOUT WASHER
Connect all water supply hoses tightly by hand and then tighten another 2/3 turn with pliers.
WITH WASHER: When connecting the dryer to the
a. Shut off the cold water tap and remove the washer hose. b. Connect the short hose to the Y-connector using one
of the hose washers.
c. Connect the other end of the short hose to the cold
water faucet.
d. Connect the long dryer hose to one side of theY-connector
and connect the washer hose to the other side.
WITHOUT WASHER: If the dryer does not share the
a. Connect tile straight end of the long hose to the cold
water faucet.
same faucet as a washer.
__--Long ....
hose
cold water tap with a washer.
F- 0 NOTE
I Before connecting the water line to the dryer, flush I several gallons of water into a drain or bucket, This will I help prevent foreign particles such assand and scale I from clogging the dryer inlet valve.
Do not overtighten, Damage to the coupling can result.
4. Turn on the cold water faucet.
S. Check for leaks at the Y-connector (if used) and in all
hoses.
I
i
ONOTE
If any leaks are found, shut off the water faucet, remove the hose and check the condition of the
20 INSTALLAiTIONINSTRUCTIONS
Connecfing Gas Dryers
_WARNING
To reduce the risk of fire, electric shock, or injury to persons when using this appliance, follow basic precautions, including the following:
Gas supply requirements: As shipped from the factory, this dryer is configured for use with natural gas. it can be
converted for use with LP (Liquefied Propane) gas. Gas pressure must not exceed 13 inches of water
column.
A qualified service or gas company technician must connect the dryer to the gas service. Failure to do socan result in fire, explosion, or death.
Isolate the dryer from the gas supply system by closing its individual manual shutoff valve during any pressure testing of the gas supply. Failure to do
so can result in fire, explosion, or death.
Supply line requirements: Your laundry room must have a rigid gas
supply line to your dryer, in the United States, an individual manual shutoff valve MUST be
installed within at least 6 ft. (1.8 m) of the dryer, in accordance with the National Fuel Gas Code
ANSi Z223.1 or Canadian gas installation code CSA
B149.1. A 1/s- inch NPT pipe plug must be instaffed. Failure to do socan result in fire, explosion, or death.
If using a rigid pipe, the rigid pipe should be 1/2
- inch IPS. if acceptable under local codes and ordinances and when acceptable to your gas
supplier, 3/e-inch approved tubing may be used where lengths are less than 20 ft. (6.1 m). Larger
tubing should be used for lengths in excess of 20 ft. (6.1 m). Failure to do so can result in fire, explosion, or death.
Electrical requirements for gas models only
. Connect the dryer to the type of gas shown on
the nameplate. Failure to do so can result in fire, explosion, or death.
. To prevent contamination of the gas valve,
purge the gas supply of air and sediment before
connecting the gas supply to the dryer. Before
tightening the connection between the gas supply and the dryer, purge remaining air until the odor of gas is detected. Failure to do socan result in fire,
explosion, or death.
. DO NOT use an open flame to inspect for gas leaks.
Use a noncorrosive leak-detection fluid. Failure to
do so can result in fire, explosion, or death.
. Use only a new AGA- or CSA-certified gas supply
line with flexible stainless steel connectors. Failure
to do so can result in fire, explosion, or death.
. Securely tighten all gas connections. Failure to do
so can result in fire, explosion, or death.
. DO NOT attempt any disassembly of the dryer;
any disassembly requires the attention and tools of an authorized and qualified service person or
company. Failure to do so can result in fire, explosion, or death.
. Use a pipe-joint compound that is insoluble in
Liquefied Petroleum (LP) gas on all pipe threads. Failure to do so can result in fire, explosion, or death.
_WARNING
To reduce the risk of fire, electric shock, or injury to persons when using this appliance, follow basic precautions, including the following:
Do not, under any circumstances, cut or remove the . This dryer must be plugged into a 60 Hz, 120 VAC, third (ground) prong from the power cord. Failure grounded outlet protected by a 1S-ampere fuse
to follow this warning can result in fire, explosion, or or circuit breaker. Failure to follow this warning can death, result in fire, explosion, or death.
For personal safety, this dryer must be properly grounded. Failure to follow this warning can result in
fire, explosion, or death.
The power cord of this dryer is equipped with a 3-prong (grounding) plug which mates with
a standard 3-prong (grounding) wall outlet to minimize the possibility of electric shock hazard
from this appliance. Failure to follow this warning can result in fire, explosion, or death.
. Where a standard 2-prong wall outlet is
encountered, it is your personal responsibility and obligation to have it replaced with a properly grounded 3-prong wall outlet. Failure to follow this
warning can result in fire, explosion, or death.
Connecfing Gas Dryers (conf.)
INSTALLAiTIONINSTRUCTIONS21
_WARNING
To reduce the risk of fire, electric shock, or injury to persons when using this appliance, follow basic precautions, including the following:
Installation and service must be performed by a qualified installer, service agency, or the gas
supplier. Failure to do so can result in fire, explosion,
or death.
Use only a new stainless steel flexible connector and a new AGA-certified connector. Failure to do so
can result in fire, explosion, or death.
A gas shutoff valve must be installed within 6 ft. (1.8 m) of the dryer. Failure to do so can result in fire,
explosion, or death.
The dryer isconfigured for Natural Gas when shipped from the factory. Make sure that the dryer
is equipped with the correct burner orifice for the type of gas being used (Natural Gas or Liquefied
Petroleum). Failure to do socan result in fire, explosion, or death.
if necessary, the correct orifice (For the LP orifice kit, order part number 383EEL3002D) should be
installed by a qualified technician and the change should be noted on the dryer. Failure to do so can
result in fire, explosion, or death.
All connections must be in accordance with local codes and regulations. Failure to do so can result in
fire, explosion, or death.
Gas dryers MUST exhaust to the outdoors. Failure to do so can result in fire, explosion, or death.
Connecting the gas supply
1.Make sure that the gas supply to the laundry room is turned OFF. Confirm that the type of gas available in
your laundry room is appropriate for the dryer. The dryer is prepared for Natural Gas with a 3/8- inch NPT
gas connection. Remove the shipping cap from the gas connection
at the back of the dryer. Be careful not to damage the threads of the gas connector when removing the
shipping cap. Connect the dryer to your laundry room's gas supply
using a new flexible stainless steel connector with a 3/s
-inch NPT fitting. Securely tighten all connections between the
dryer and your laundry room's gas supply. Turn on your laundry room's gas supply and check all pipe connections (both internal and external) for gas leaks with a noncorrosive leak-detection fluid.
Electrical connection
Plug dryer into a 120 VAC,
outlet.
__ 60 Hz grounded 3-prong
3/8" NPT Gas Connection
AGA/CSA-Certified Stainless Steel Flexible
Connector
High-altitude installations
The BTU rating of this dryer is AGA-certified for
elevations below 10,000 feet.
If your gas dryer is being installed at an elevation above 10,000 feet, it must be derated by a qualified technician
or gas supplier.
Gas Supply ShutoffValve
22 INSTALLAiTION INSTRUCTIONS
Connecfing Elecfric Dryers
_WARNING
To help prevent fire, electric shock, serious injury, or death, the wiring and grounding must conform to the latest edition of the National Electrical Code,
ANSI/NFPA 70 and all applicable local regulations, Please contact a qualified electrician to check your
home's wiring and fuses to ensure that your home has adequate electrical power to operate the dryer,
Electrical requirements for electric models only
_WARNING
To reduce the risk of fire, electric shock, or injury to persons when using this appliance, follow basic
precautions, including the following:
This dryer must be connected to a grounded metal, permanent wiring system, or an equipment-
grounding conductor must be run with the circuit conductors and connected to the equipment-
grounding terminal or lead on the dryer. Failure to do so can result in fire, explosion, or death.
The dryer has its own terminal block that must
be connected to a separate 240 VAC, 60-Hertz, single-phase circuit, fused at 30 amperes (the
circuit must be fused on both sides of the line). ELECTRICAL SERVICE FOR THE DRYER SHOULD BE OF THE MAXIMUM RATE VOLTAGE LISTED ON THE
NAMEPLATE. DO NOT CONNECT DRYER TO 110-, 115-, OR 120-VOLT CIRCUIT. Failure to follow these instructions can result in fire, explosion, or death.
If branch circuit to dryer is 15 ft. (4.5 m) or less in
length, use UL (Underwriters Laboratories) listed
No.-10 AWG wire (copper wire only), or as required by local codes. If over 15 ft. (4.5 m), use UL-listed
No.-8 AWG wire (copper wire only), or as required by local codes. Allow sufficient slack in wiring
so dryer can be moved from its normal location when necessary. Failure to do so can result in fire,
explosion, or death.
The power cord (pigtail) connection between
wall receptacle and dryer terminal block IS NOT supplied with dryer. Type of pigtail and gauge
of wire must conform to local codes and with instructions on the following pages. Failure to
follow these instructions can result in fire, explosion, or death.
A 4-wire connection is required for all mobile and
manufactured home installations, as well as all new construction after January 1, 1996. A 4-wire
connection must be used where local codes do not permit grounding through the neutral wire. Failure
to do so can result in fire, explosion, or death.
_WARNING
To reduce the risk of fire, electric shock, or injury to persons when using this appliance, follow basic
precautions, including the following:
Do not modify the plug and internal wire provided with the dryer.
The dryer should be connected to 4-hole outlet.
If it does not fit the outlet, a proper outlet will
need to be installed by a qualified electrician.
_WARNING
To reduce the risk of fire, electric shock, or injury to persons when using this appliance, follow basic
precautions, including the following:
Any installation in a manufactured or mobile home must comply with the Manufactured Home
Construction and Safety Standards Title 24 CFR, Part 3280 or Standard CAN/CSA Z240 MH and
local codes and ordinances.
A 4-wire connection is required for all mobile and
manufactured home installations, as well as all new construction after January 1, 1996. Failure to do so can result in fire, explosion, or death.
Connecfing Elecfric Dryers (conf.)
USA only
_WARNING
Connect the power cord to the terminal block. Connect each power cord wire to the terminal block screw that has the same colored wire. For example,
connect the black power cord wire to the terminal block screw with the black wire. Failure to follow
these instructions may result in ashort, overload, fire or death.
Grounding through the neutral conductor is prohibited for: (1) new branch-circuit installations,
(2) mobile homes, (3) recreational vehicles, and (4) areas where local codes prohibit grounding through the neutral conductor,
Four-wire connection for electric dryers:
Power cord
A 4-wire connection is required for all mobile and manufactured home installations, as well as all new
construction after January 1, 1996.
A ULqisted strain relief is required.
1.Remove the terminal block access cover on the upper back of the dryer. Install a UL-listed strain relief into the power cord through-hole; then thread a UL-listed, 30 A, 240 V, 4-wire, #10 AWG-minimum copper conductor power cord through the strain relief.
INSTALLAiTIONINSTRUCTIONS23
. Use a 30 A, 240 V, UL-listed power cord with #10
AWG-minimum copper conductor and closed loop or
forked terminals with upturned ends.
2. Transfer the dryer's ground wire from behind the green ground screw to the center screw of the
terminal block. Attach the two hot leads of the power cord to the outer terminal block screws. Attach the
white neutral wire to the center terminal block screw. Attach the power cord ground wire to the green
ground screw, TIGHTEN ALL SCREWS SECURELY. Reinstall the terminal block access cover.
Hot Neutral
(Black) (White)
Grou nd_--_ =_=_i__ Hot
Screw I (Red)
W iv'e ;re
POoW:rdC_e, _ Ground Screw
_r_ _/_E:,,_ I_.._Terminal
I I l/uL-Listed
__ Strain Relief
Cord
24 INSTALLAiTION INSTRUCTIONS
Connecting Elecfric Dryers (conf.)
USA only
_WARNING
Connect the power cord to the terminal block. Connect each power cord wire to the terminal block screw that has the same colored wire. For example, connect the black power cord wire to the terminal
block screw with the black wire. Failure to follow these instructions may result in a
short, overload, fire or death.
Grounding through the neutral conductor is prohibited for: (1) new branch-circuit installations, (2) mobile homes, (3} recreational vehicles, and (4) areas where local codes prohibit grounding through the neutral conductor.
Four-wire connection for electric dryers: Direct wire
A 4-wire connection is required for all mobile and manufactured home installations, as well as all new
construction after January 1, 1996,
. A UL-listed strain relief is required,
1,Remove 5 inches (12.7 cm) of the outer covering from
the wire. Remove Sinches of insulation from the ground wire, Cut off approximately 11/2inches (3,8 cm)
from the other three wires and strip 1 inch (2.5 cm) insulation from each wire, Bend the ends of the three
shorter wires into a hook shape,
1" (2.5cm)
H
Ground Wire
. Use UL-listed 4-wire #10 AWG-minimum copper
conductor cable.
. Allow at least Sft. (1.S m) length to allow for removal
and reinstallation of the dryer,
3.Transfer the dryer's ground wire from behind the green ground screw to the center screw of the terminal block. Attach the two hot leads of the power
cable to the outer terminal block screws, Attach the white neutral wire to the center terminal block screw.
Attach the power cable ground wire to the green ground screw, TIGHTEN ALL SCREWS SECURELY.
Reinstall the terminal block access cover,
Hot Neutral
(Black) (White)
Ground _ _------_----------_(_Hel )
Screw ___ White Wire
............ moved from
Power Cord /'_ Ground Screw Ground Wire <_-__
2, Remove the terminal block access cover on the upper
back of the dryer. Install a UL-listed strain relief into the power cord through-hole; then thread the power cable prepared in Step 1 through the strain reliefl
Terminal
Block
L ..... _1..... _ Strain Relief
!ted L-Liste4_wire_
IL-Li
Power Cord
Connecting Elecfric Dryers (conf.)
USA only
INSTALLAiTIONINSTRUCTIONS25
_WARNING
Connect the power cord to the terminal block. Connect each power cord wire to the terminal
block screw that has the same colored wire. For example, connect the black power cord wire to the
terminal block screw with the black wire. Failure to follow these instructions may result in a short,
overload, fire or death.
Grounding through the neutral conductor is prohibited for: (1) new branch-drcuit installations,
(2) mobile homes, (3) recreational vehicles, and (4) areas where local codes prohibit grounding
through the neutral conductor.
Three-wire connection for electric dryers: Power cord
A 3-wire connection is NOT permitted on new construction after January 1, 1996.
A UL-iisted strain relief is required.
1.Remove the terminal block access cover on the upper back of the dryer. Install a UL-listed strain relief
into the power cord through-hole; then thread a UL- listed, 30 A, 240 V, 3-wire, #10 AWG-minimum
copper conductor power cord through the strain reliefl
_ _i_---_ !...,_Terminal
. Use a 30 A, 240 V, UL-listed power cord with #10
AWG-minimum copper conductor and closed loop or
forked terminals with upturned ends.
2. Attach the two hot leads of the power cord to the outer terminal block screws. Attach the neutral wire to
the center terminal block screw. Connect the external ground (if required by local codes) to the green
ground screw. TIGHTEN ALL SCREWS SECURELY. Reinstal] the terminal block access cover.
Hot
(Black)
Neutral (White)
Ground(
Screw t __(Red)
Wire
from Dryer White
harness
External Ground Wire (If required
by local codes)
I I I/UL-Listed __ Strain Relief
Cord
26 INSTALLAiTION INSTRUCTIONS
Connecting Elecfric Dryers (conf.)
USA only
_WARNING
Connect the power cord to the terminal block. Connect each power cord wire to the terminal block screw that has the same colored wire. For example, connect the black power cord wire to the terminal
block screw with the black wire. Failure to follow these instructions may result in a short, overload,
fire or death.
Grounding through the neutral conductor is prohibited for: (1} new branch-circuit installations,
(2) mobile homes, (3) recreational vehicles, and (4) areas where local codes prohibit grounding
through the neutral conductor.
Three-wire connection for electric dryers: Direct wire
A 3-wire connection is NOT permitted on new construction after January 1, 1996.
A ULqisted strain relief is required.
1.Remove 3/2 inches (8.9 cm) of the outer covering from the wire. Strip 1 inch (2.5 cm) insulation from each
wire. Bend the ends of the three wires into a hook shape.
2. Remove the terminal block access cover on the upper back of the dryer. Install a ULqisted strain relief into the power cord through-hole; then thread the power cable prepared in Step 1 through the strain reliefl
1
1" (2,5 cm)
I-4
. Use UL-listed 3-wire #10 AWG-minimum copper
conductor cable.
. Allow at least 5ft. (1.5 m) length to allow for removal
and reinstallation of the dryer.
3.Attach the two hot leads of the power cord to the outer terminal block screws. Attach the neutral wire to
the center terminal block screw. Connect the external ground (if required by local codes) to the green
ground screw. TIGHTEN ALL SCREWS SECURELY. Reinstall the terminal block access cover.
Hot
(Black)
Ground _ Hot
White Wire / __
from Dryer ""
harness /
External Ground Wire (if required
by local codes)
Neutral (White)
_ Red)
Uk-IJsted 3-Wire / Power Cord
Terminal
Block
Li2t; 1,of
Loading...