LG C09LCR, C09LCB, C09LCM, C12LCB, C12LCM Owner's Manual

...
Page 1
  
Page 2
2 Room Air Conditioner
Room Air Conditioner Owner’s Manual
TABLE OF CONTENTS
Write the model and serial numbers here:
Model # Serial #
You can find them on a label on the side of each unit.
Dealer's Name Date Purchased
Staple your receipt to this page in the event you need it to prove date of purchase or for warranty issues.
READ THIS MANUAL
Inside you will find many helpful hints on how to use and maintain your air conditioner properly. Just a little preventive care on your part can save you a great deal of time and money over the life of your air conditioner.
You'll find many answers to common problems in the chart of troubleshooting tips. If you review our chart of
Troubleshooting Tips first, you may not need to call for service at all.
PRECAUTION
Contact the authorized service technician for
repair or maintenance of this unit.
• Contact the installer for installation of this unit.
• The air conditioner is not intended for use by
young children or invalids without supervision.
• Young children should be supervised to ensure
that they do not play with the air conditioner.
• When the power cord is to be replaced,
replacement work shall be performed by authorized personnel only using only genuine replacement parts.
• Installation work must be performed in
accordance with the National Electric Code by qualified and authorized personnel only.
Safety Precautions.........................3
Prior to Operation ..........................8
Introduction....................................9
Electrical Safety ...........................10
Operating Instructions.................12
Maintenance and Service............26
Page 3
Owner's Manual 3
Safety Precautions
ENGLISH
Safety Precautions
To prevent the injury of the user or other people and property damage, the following instructions must be followed.
Incorrect operation due to ignoring instruction will cause harm or damage. The seriousness is classified by the following indications.
This symbol indicates the possibility of death or serious injury.
This symbol indicates the possibility of injury or damage to properties only.
The meanings of the symbols used in this manual are as shown below.
Be sure not to do.
Be sure to follow the instruction.
Installation
Always perform grounding.
• Otherwise, it may cause electrical shock.
Don’t use a power cord, a plug or a loose socket which is damaged.
• Otherwise, it may cause a fire or electrical shock.
For installation of the product, always contact the service center or a professional installation agency.
• Otherwise, it may cause a fire, electrical shock,
explosion or injury.
Securely attach the electrical part cover to the indoor unit and the service panel to the outdoor unit.
• If the electrical part cover of the indoor unit and the service panel of the outdoor unit are not attached securely, it could result in a fire or electric shock due to dust, water, etc.
Page 4
4 Room Air Conditioner
Safety Precautions
Always install an air leakage breaker and a dedicated switching board.
• No installation may cause a fire and electrical shock.
Do not keep or use flammable gases or combustibles near the air conditioner.
• Otherwise, it may cause a fire or the failure of product.
Ensure that an installation frame of the outdoor unit is not damaged due to use for a long time.
• It may cause injury or an accident.
Do not disassemble or repair the product randomly.
• It will cause a fire or electrical shock.
Do not install the product at a place that ther is concern of falling down.
• Otherwise, it may result in personal injury.
Use caution when unpacking and installing.
• Sharp edges may cause injury.
Do not share the outlet with other appliances.
• It will cause an electric shock or a fire due to heat generation.
Do not use the damaged power cord.
• Otherwise, it may cause a fire or electrical shock.
Do not modify or extend the power cord randomly.
• Otherwise, it may cause a fire or electrical shock.
Take care so that the power cord may not be pulled during operation.
• Otherwise, it may cause a fire or electrical shock.
Unplug the unit if strange sounds, smell, or smoke comes from it.
• Otherwise, it may cause electrical shock or a fire.
Keep the flames away.
• Otherwise, it may cause a fire.
Operation
Wax
Thinner
Page 5
Owner's Manual 5
Safety Precautions
ENGLISH
Take the power plug out if necessary, holding the head of the plug and do not touch it with wet hands.
• Otherwise, it may cause a fire or electrical shock.
Do not use the power cord near the heating tools.
• Otherwise, it may cause a fire and electrical shock.
Do not open the suction inlet of the indoor/outdoor unit during operation.
• Otherwise, it may electrical shock and failure.
Do not allow water to run into electrical parts.
• Otherwise, it may cause the failure of machine or electrical shock.
Hold the plug by the head when taking it out.
• It may cause electric shock and damage.
Never touch the metal parts of the unit when removing the filter.
• They are sharp and may cause injury.
Ventilate the room well when using this appliance together with a stove, etc.
• An oxygen shortage may occur.
When cleaning the unit, first make sure the power and breaker are turned off.
• Otherwise, it may cause electrical shock.
Turn off the main power switch when not using the product for a long time.
• Otherwise, it may cause the failure of product or a fire.
Do not step on the indoor/outdoor unit and do not put anything on it.
• It may cause an injury through dropping of the unit or falling down.
Do not place a heavy object on the power cord.
• Otherwise, it may cause a fire or electrical shock.
Page 6
6 Room Air Conditioner
Safety Precautions
When the product is submerged into water, always contact the service center.
• Otherwise, it may cause a fire or electrical shock.
Take care so that children may not step on the outdoor unit.
• Otherwise, children may be seriously injured due to falling down.
Install the drain hose to ensure that drain can be securely done.
• Otherwise, it may cause water leakage.
Install the product so that the noise or hot wind from the outdoor unit may not cause any damage to the neighbors.
• Otherwise, it may cause dispute with the
neighbors.
Always inspect gas leakage after the installation and repair of product.
• Otherwise, it may cause the failure of product.
Keep level parallel in installing the product.
• Otherwise, it may cause vibration or water leakage.
Installation
Page 7
Owner's Manual 7
Safety Precautions
ENGLISH
Do not insert the hands or bars through the air inlet or outlet during operation.
• Otherwise, it may cause personal injury.
Do not drink water coming out of the air conditioner.
• Otherwise, it may cause stomachache.
Avoid excessive cooling and perform ventilation sometimes.
• Otherwise, it may do harm to your health.
Use a soft cloth to clean. Do not use wax, thinner, or a strong detergent.
• The appearance of the air conditioner may deteriorate, change color, or develop surface flaws.
When gas leaks, open the window for ventilation before operating the unit.
• Otherwise, it may cause explosion, and a fire.
Do not use an appliance for special purposes such as preserving animals vegetables, precision machine, or art articles.
• Otherwise, it may damage your properties.
Do not place obstacles around the flow inlet or outlet.
• Otherwise, it may cause the failure of appliance or an accident.
Always insert the filter securely. Clean it every two weeks.
• Operation without the filter will cause failure.
Operation
Wax
Thinner
Page 8
8 Room Air Conditioner
Prior to Operation
Prior to Operation
1. Contact an installation specialist for installation.
2. Plug in the power plug properly.
3. Use a dedicated circuit.
4. Do not use an extension cord.
5. Do not start/stop operation by plugging/unplugging the power cord.
6. If the cord/plug is damaged, replace it with only an authorized replacement part.
1. Being exposed to direct airflow for a long time may be hazardous to your health. Do not expose occupants, pets, or plants to direct airflow for a long time.
2. Due to the possibility of oxygen deficiency, ventilate the room when using the appliance together with stoves or other heating devices.
3. Do not use this air conditioner for non-specified special purpose (e.g. preserving precision devices, food, pets, plants, or art objects). Such use may damage your properties.
1. Do not touch the metal parts of the unit when removing the filter. Injury can occur.
2. Do not use water to clean inside the air conditioner. Exposure to water can destroy the insulation, leading to electric shock.
3. When cleaning the unit, first make sure that the power and breaker are turned off. The fan rotates at a very high speed during operation. There is a possibility of injury if the unit’s power is triggered while cleaning inner parts of the unit.
For repair and maintenance, contact your authorized service dealer.
Preparing for Operation
Usage
Cleaning and Maintenance
Service
Page 9
Page 10
10 Room Air Conditioner
Electrical Safety
Electrical Safety
WARNING: This appliance must be properly grounded.
To minimize the risk of electric shock, you must alway plug into a grounded oulet.
WARNING: Do not cut or remove the grounding prong from the power plug.
WARNING: Attaching the adapter ground terminal to the wall receptacle cover screw does not ground the appliance unless the cover screw is metal and not insulated, and the wall receptacle is grounded through the house wiring.
WARNING: If you have any doubt whether the air conditioner is properly grounded, have the wall receptacle and circuit checked by a qualified electrician.
Preferred method
Ensure proper ground
exists before use
Page 11
Owner's Manual 11
Electrical Safety
ENGLISH
Temporary Use of an Adapter
We strongly discourage the use of an adapter due to potential safety hazards. For temporary connections, use only a UL-listed adapter, available from most local hardware stores. Ensure that the large slot in the adapter is aligned with the large slot in the receptacle for a proper polarity connection.
To disconnect the power cord from the adapter, use one hand on each to avoid damaging the ground terminal. Avoid frequently unplugging the power cord as this can lead to eventual ground terminal damage.
WARNING: Never use the appliance with a broken adapter.
We strongly discourage the use of an extension cord due to potential safety hazards. For temporary situations, use only CSA certified and UL listed 3-wire grounded extension cords, rated 15 A, 125 V.
Temporary Use of an Extension Cord
Temporary method
Adapter Plug
Receptacle Cover
Metal Screw
Page 12
Page 13
Page 14
14 Room Air Conditioner
ON
Cooling
Healthy
Dehumidification
Auto
Heating
(Heat pump model only)
To lower the temperature
To raise the temperature
Operating Instructions
Press the Start/Stop button. The unit will respond with a beep.
Open the door of the remote controller. To select Cooling Operation, press the Operation Mode Selection button. Each time the button is pressed, the operation mode is shifted in the direction of the arrow.
Close the door of the remote controller. Set the temperature lower than the room temperature. The temperature can be set within a range of 18°C~30°C at intervals of 1°C.
Set the fan speed again with the door of the remote controller still closed. You can select the fan speed in four steps-low, medium, high and CHAOS. Each time the button is pressed, the fan speed mode is shifted.
1
2
3
4
Natural wind by the CHAOS logic
For fresher feeling, press the Indoor fan speed selector and set to CHAOS mode. In this mode, the wind
blows like a natural breeze by automatically changing fan speed according to the CHAOS logic.
Cooling operation
Page 15
ENGLISH
Owner's Manual 15
ON
Cooling
Healthy
Dehumidification
Auto
Heating
(Heat pump model only)
To lower the temperature
To raise the temperature
Operating Instructions
Press the Start/Stop button. The unit will respond with a beep.
Open the door of the remote controller. To select Auto Operation, press the operation mode selection button. Each time the button is pressed, the operation mode is shifted in the direction of the arrow.
The temperature and fan speed are automatically set by the electronic controls based on the actual room temperature. If you want to change the set temperature, press the Room Temperature Setting buttons. The cooler or warmer you feel, the more times (up to two times) you should press the button. The set temperature will be changed automatically.
During Auto Operation
You cannot control the indoor fan speed. It has already been set by the Fuzzy rule.If the system is not operating as desired, manually switch to another mode. The system will not
automatically switch from the cooling mode to the heating mode, or from heating mode to cooling mode, it must be done by manually resetting.
During Auto Operation, pressing the chaos swing button makes the horizontal louvers swing up and
down automatically. If you want to stop auto-swing, press the chaos swing button again.
1
2
3
Auto operation (Cooling model only)
Page 16
16 Room Air Conditioner
ON
Cooling
Healthy
Dehumidification
Auto
changeover
Heating
(Heat pump model only)
To lower the temperature
To raise the temperature
Operating Instructions
Auto changeover operation(Heat pump model only)
Press the Start/Stop button. The unit will respond with a beep.
Open the door of the remote controller. To select Auto Changeover Operation, press the Operation Mode Selection button. Each time the button is pressed, the operation mode is shifted in the direction of the arrow.
1
2
Close the door of the remote controller. Set the temperature lower than the room temperature. The temperature can be set within a range of 18°C~30°C at intervals of 1°C.
Set the fan speed again with the door of the remote controller still closed. You can select the fan speed in four steps-low, medium, high and CHAOS. Each time the button is pressed, the fan speed mode is shifted.
3
4
During Auto changeover Operation
The air conditioner changes the operation mode automatically to keep indoor temperature. When room temperature vary over ±2°C with respect to setting temperature, air conditioner keeps the room temperature within ±2°C with respect to setting temperature by auto changeover mode.
Page 17
ENGLISH
Owner's Manual 17
ON
Cooling
Healthy
Dehumidification
Auto
Heating
(Heat pump model only)
Operating Instructions
Press the Start/Stop button. The unit will respond with a beep.
Open the door of the remote controller. To select Healthy Dehumidification Operation, press the Operation Mode Selection button. Each time the button is pressed, the operation mode is shifted in the direction of the arrow.
1
2
Set the fan speed again with the door of the remote controller still closed. You can select the fan speed in four steps-low, medium, high, or CHAOS. Each time the button is pressed, the fan speed mode is shifted.
3
Natural wind by the CHAOS logic
For fresher feeling, press the Indoor Fan Speed Selector and set
to CHAOS mode. In this mode, the wind blows like a natural breeze by automatically changing fan speed according to the CHAOS logic.
Healthy dehumidification operation
During Healthy Dehumidification Operation
If you select the dehumidification mode on the operation selection button, the A/C starts to run the
dehumidification function. It automatically sets the room temp. and airflow volume to the best condition for dehumidification, based on the sensed current room temp.
In this case, however, the setting temp. is not displayed on the remote controller and you are not able to control the room temp. either.
During the healthy dehumidification function, the airflow volume is automatically set according to the
optimization algorithm responding to the current room temp. status, so that the room condition is kept healthy and comfortable even in the very humid season.
Page 18
18 Room Air Conditioner
ON
Cooling
Healthy
Dehumidification
Auto
Heating
(Heat pump model only)
To lower the temperature
To raise the temperature
Operating Instructions
Heating operation (Heat pump model only)
Press the Start/Stop button. The unit will respond with a beep.
Open the door of the remote controller. To select Heating Operation, press the Operation Mode Selection button. Each time the button is pressed, the operation mode is shifted in the direction of the arrow.
Close the door of the remote controller. Set the temperature higher than the room temperature. The temperature can be set within a range of 16°C~30°C at intervals of 1°C.
Set the fan speed again with the door of the remote controller still closed. You can select the fan speed in four steps–low, medium, high and CHAOS. Each time the button is pressed, the fan speed mode is shifted.
1
2
3
4
Natural wind by the CHAOS logic
For fresher feeling, press the Indoor Fan Speed Selector and set to CHAOS mode. In this mode, the
wind blows like a natural breeze by automatically changing fan speed according to the CHAOS logic.
Page 19
ENGLISH
Owner's Manual 19
or or
Operating Instructions
During the JET COOL function at any moment, the A/C starts to blow the cool air at extremely
high speed for 30 minutes setting the room temp. automatically to 18°C. It is especially used to cool the room temp. quickly in a hot summer.
In heat pump mode or neuro fuzzy mode, however, the JET COOL function is not available.
In order to return to the normal cooling mode from the JET COOL mode, just press the operation
mode selection button, airflow volume selection, temp. setting button or the JET COOL button again.
NOTICE
Press the Start/Stop button. The unit will respond with a beep.
Press the Jet Cool button to operate the speed cooling mode and the unit will operate at super high fan speed on cooling mode for 30 minutes.
To cancel the Jet Cool mode, press the Jet Cool button, the fan speed button or the room temperature setting button again and the unit will operate at high fan speed on cooling mode.
1
2
3
Jet cool operation
Page 20
20 Room Air Conditioner
Operating Instructions
Press the Start/Stop button. The unit will respond with a beep.
1
Open the door of the remote controller. Press the NANO PLASMA button.
Operation will start when the button is pressed and stop when the button is pressed again.
2
Set the fan speed again with the door of the remote controller closed. You can select the fan speed in four steps-low, medium, high or CHAOS. Each time the button is pressed, the fan speed mode is shifted.
Air purifying operation (NANO PLASMA) can be
with cooling, Heating or any other operations.
NANO PLASMA Air Purifying Operation only
If you press the only NANO PLASMA button, only NANO PLASMA purification function operates. Then, fan speed is low. You can select the fan speed in four steps-low, medium, high or CHAOS. Each time the button ( ) is pressed, the fan speed mode is shifted.
3
NANO PLASMA purification operation(Optional)
Page 21
ENGLISH
Owner's Manual 21
ON
OFF
CANCEL
SET
ON
OFF
SET
AUTO CLEAN
Operating Instructions
Press the Start/Stop button. The unit will respond with a beep.
Open the door of the remote control and press the 2nd Function button to operate functions printed in blue unter buttons. (Check the indication of 2nd function on the display of the remote controller.) These buttons can set the timer as follows:
2nd function disappears in a short time automatically or when the button is pressed again.
1
2
3
2nd F operation
For more details, refer to functions next pages.
Page 22
22 Room Air Conditioner
Delay OFF Timer Delay ON Timer Delay OFF and ON Timer Delay ON and OFF Timer
Operating Instructions
Sleep mode
1. Press the Sleep Mode Auto button to set the time you want the unit to stop automatically.
2. The Timer is programmed in one-hour increments by pressing the Sleep Mode Auto button 1 to 7 times. The sleep mode is available for 1 to 7 times. To alter the time period in steps of 1 hour, press the Sleep Mode Button while aiming at air conditioner.
3. Make sure the Sleep Mode Auto LED lights up. To cancel the Sleep Mode, press the sleep Mode Auto button several times until the star ( ) disappears from the operation display.
The Sleep Mode will be operated at slow fan speed (cooling) or medium fan speed (heat pump only) for a comfortable sleep.
In cooling mode or healthy dehumidification mode:
The temperature will automatically rise by 1°C over the next 30 minutes and by 2°C in 1 hour for a comfortable sleep.
NOTICE
Setting the time
1. Time can be set only when you press the Reset button. Having replacing the batteries, you should press the reset buttons to reset the time. Press the Start/Stop button.
2. Press 2nd F button and check if 2nd F icon is on.
3. Press the Time Setting buttons until the desired time is set.
4. Press the Timer SET button.
Check the indicator for A.M. and P.M.
NOTICE
1. Make sure the time is set correctly on the display of the remote controller.
2. Press 2nd F button.
3. Press the ON/OFF Timer buttons to turn Timer on or off.
4. Press the Time Setting buttons until the desired time is set.
5. To set the selected time, press the Timer setting button aiming the remote controller at the signal receptor.
To cancel the timer setting
Check if 2nd F icon is off. Press the Timer Cancel button aiming the remote controller at the signal receptor. (The timer lamp on the air conditioner and the display will go out.)
Delay start/Pre-set stop
Select one of the following four types of operation.
NOTICE
with the unit running
ON
OFF
CANCEL
SET
CANCEL
SET
CANCEL
SET
Additional Features
Page 23
ENGLISH
Owner's Manual 23
Fan speed is on low. Fan speed is on medium. Fan speed is on high.CHAOS Air
Operating Instructions
Vertical Airflow Direction Control
The up/down airflow (Vertical Airflow) can be adjusted by using the remote control.
1. Press the Start/Stop button to start the unit.
2. Press Chaos Swing button and the louvers will swing up and down. Press the Chaos Swing button again to set the vertical louver at the desired airflow direction.
If you press the CHAOS swing button, the
horizontal airflow direction is changed automatically based on the CHAOS algorithm to distribute the air in the room evenly and at the same time to make the human body feel most comfortable, as if enjoying a natural breeze.
Always use the remote control to adjust the
up/down airflow direction. Manually moving the vertical airflow direction louver by hand, could damage the air conditioner.
When the unit is shut off, the up/down airflow
direction louver will close the air outlet vent of the system.
NOTICE
Horizontal Airflow Direction Control (Optional)
The left/right(Horizontal Airflow) can be adjusted by using the remote control. Press the Start/Stop button to start the unit. Open the door on the remote control. Press the Airflow Direction Start/Stop
button and the louvers will swing left and right. Press the Horizontal Airflow Direction Control Button again to set the horizontal louver at the desired airflow direction.
Air circulation mode
Circulates the room air without cooling or heating.
1. Press the Start/Stop button. the unit will respond with a beep.
2. Open the door on the remote control. Press the Air Circulation button. Close the door on the remote control. Now each time that you press the Indoor Fan Speed Selector, the fan speed is shifted from low to CHAOS and back to low again.
CHAOS Air economizes power consumption and prevents overcooling. The fan speed is automatically changed from high to low or vice versa, depending on the ambient temperature.
NOTICE
Page 24
24 Room Air Conditioner
AUTO CLEAN
Operating Instructions
During Auto Clean function, moistures left in indoor units after Cooling Operation or Healthy
Dehumidification Operation can be removed.
During Auto Clean function, only Start/Stop button, Plasma button and Auto Clean button are available.
NOTICE
Auto clean (Optional)
1. Whenever you press the Auto Clean button, Auto Clean Function will be reserved and cancelled.
2. Auto Clean function works before and after cooling or dehumidification mode. For details, refer to the below points.
3. When the unit is started after the reservation of Auto Clean ,the Cool Start function operates and indoor Fan is started after 20 seconds.
4. When you press Start/Stop button to turn off the unit after the you have reserved Auto Clean function, the air-conditioner circulates the indoor air in the Auto Clean mode with no more Cooling or Dehumidification operation. For Cooling only model, it lasts for 30 minutes for Heat pump model, for 16 minutes.
5. If you press the auto clean button again during the product operation , Auto Clean function will be cancelled.
Display Luminosity (Optional)
The Display Luminosity can be adjusted by using the remote control. Press the start/stop button to start the unit. Open the door on the remote control, press the 2ndF button and, press display luminosity button. Display will be dark. Press the button again to set bright display.
Page 25
ENGLISH
Owner's Manual 25
Power
button
High
Speed
Operating Instructions
Operation procedures when the remote control can't be used. The operation will be started if the power button is pressed. If you want to stop operation, re-press the button.
Forced operation
Auto restart
In case the power comes on again after a power failure, Auto Restarting Operation is the function to operate procedures automatically to the previous operating conditions. So there is no need of activating this function by pressing any key or button. In the initial mode, the fan operates at a low speed and the compressor starts 2.5~3 minutes later. As the compressor starts, the fan speed also resumes its previous setting mode.
Heat pump Model
Cooling Model
Room Temp. 24°C21°C ≤ Room Temp. < 24°C Room Temp. < 21°C
Operating mode Cooling Cooling Healthy Dehumidification Heating
Indoor FAN Speed
High High High High
Setting Temperature
22°C22°C23°C24°C
Helpful information
Fan speed and cooling capacity. The cooling capacity indicated in the specification is the value when the fan speed is set to high, and the capacity will be lower at low or medium fan speed. High fan speed is recommended when you wish to cool the room quickly.
Test operation
During the TEST OPERATION, the unit operates in cooling mode at high speed fan, regardless of room temperature and resets in 18 minutes. During test operation, if remote controller signal is received, the unit operates as remote controller sets. If you want to use this operation, open the front panel upward and Press the power button let it be pressed for about 3 seconds. If you want to stop the operation, re-press the button.
Page 26
26 Room Air Conditioner
Front panel
Panel hook
Air filters
Air filters
G
a
s
o
l
i
n
e
P
o
w
d
e
r
Maintenance and Service
Maintenance and Service
Indoor Unit
WARNING: Turn the system off before cleaning. To clean, wipe with a soft, dry cloth. Do not use bleach or abrasives.
Supply power must be disconnected before cleaning the indoor unit.
NOTICE
1. Open the upside of Front Panel
2. Put up the Front panel. The hook of panel comes off.
3. Come down the panel and then remove the air filter.
WARNING: Dont touch the PLASMA Filter within 10 seconds after opening the inlet grille, it may cause electric shock.
4. Clean it wi a soft brush and the vacuum cleaner. If it is very dirty, wash it with water.
5. Reinstall the air filter dried at the shade and then close the panel.
Never use any of the followings:
Water hotter than 40°C
Could cause deformation and/or discoloration.
Volatile substances
Could damage the surfaces of the air conditioner.
Page 27
Page 28
28 Room Air Conditioner
Maintenance and Service
Common Problems and Solutions
Before calling for service
If you have problems with your air conditioner, read the following information and try to solve the problem. If you cannot find a solution, turn off the air conditioner and contact your dealer.
Air conditioner does not operate
1. Ensure that the air conditioner is plugged into a proper outlet.
2. Check the fuse or circuit breaker.
3. Check whether the voltage is unusually high or low.
Air does not feel cold enough on the cooling setting
1. Ensure that the temperature settings are correct.
2. Check to see if the air filter is clogged with dust. If so, replace the filter.
3. Ensure that the air flow from the outside is not obstructed and that there is a clearance of over 20" between the back of the air conditioner and the wall or fence behind it.
4. Close all doors and windows and check for any source of heat in the room.
Before calling for service, please review the following list of common problems and solutions.
The air conditioner is operating normally when:
You hear a pinging noise. This is caused by water being picked up by the fan on rainy days
or in highly humid conditions. This feature is designed to help remove moisture in the air and improve cooling efficiency.
You hear the thermostat click. This is caused by the compressor cycle starting and
stopping.
You see water dripping from the rear of the unit. Water may be collected in the base pan in
highly humid conditions or on rainy days. This water overflows and drips from the rear of the unit.
You hear the fan running while the compressor is silent. This is a normal operational
feature.
Page 29
ENGLISH
Owner's Manual 29
Maintenance and Service
Troubleshooting
The air conditioner may be operating abnormally when:
Problem
The air conditioner is unplugged.
The fuse is blown/circuit breaker is tripped.
Power failure.
Airflow is restricted.
The thermostat may not be
set high enough.
The air filter is dirty.
The room may have been
hot.
Cold air is escaping.
Cooling coils have iced up.
Ice blocks the air flow and
stops the air conditioner from cooling the room.
Air conditioner does not start
Air conditioner does not cool as it should
Air conditioner freezing up
Make sure the air conditioner plug is pushed completely into the outlet.
Check the house fuse/circuit breaker box and replace the fuse or reset the breaker.
If power failure occurs, turn the mode control to Off. When power is restored, wait 3 minutes to restart the air conditioner to prevent tripping of the compressor overload.
Make sure there are no curtains, blinds, or furniture blocking the front of the air conditioner.
Turn the knob to a higher number. The highest setting provides maximum cooling.
Clean the filter at least every 2 weeks. See the care and Maintenance section.
When the air conditioner is first turned on, you need to allow time for the room to cool down.
Check for open furnace floor registers and cold air returns.
See Air Conditioner Freezing Up below.
Set the mode control at High Fan or High Cool with thermostat at 1 or 2.
What To DoPossible Causes
* You can refer to the Energy Star program in detail at www.energystar.gov.
Page 30
P /No.: 3828 A 20266X