Please read this installation manual completely before installing the product.
Installation work must be performed in accordance with the national wiring
standards by authorized personnel only.
Please retain this installation manual for future reference after reading it thoroughly.
Ɠ
This product contains Fluorinated Greenhouse Gases. (R410A)
Here are some tips that will help you minimize the power consumption when you use the air
conditioner. You can use your air conditioner more efficiently by referring to the instructions
below:
• Excessive cooling may be harmful to your health and may consume more electricity.
• Block sunlight with blinds or curtains while you are operating the air conditioner.
• Keep doors or windows closed while you are operating the air conditioner.
• Adjust the direction of the air flow vertically or horizontally to circulate indoor air.
• Speed up the fan to cool or warm indoor air quickly, in a short period of time.
• Open windows regularly for ventilation as the indoor air quality may deteriorate if the air
conditioner is used for many hours.
• Clean the air filter once every 2 weeks. Dust and impurities collected in the air filter may block the
air flow or weaken the cooling / dehumidifying functions.
For your records
Staple your receipt to this page in case you need it to prove the date of purchase or for warranty
purposes. Write the model number and the serial number here:
Model number :
Serial number :
You can find them labeled on the side of each unit.
Dealer’s name :
Date of purchase :
IMPORTANT SAFETY INSTRUCTIONS
3
IMPORTANT SAFETY INSTRUCTIONS
READ ALL INSTRUCTIONS BEFORE USING THE APPLIANCE.
Always comply with the following precautions to avoid dangerous
situations and ensure peak performance of your product
WARNING
!
Serious injury or death can result if directions are ignores.
CAUTION
!
Minor injury or product damage can result if directions are ignored.
WARNING
!
• Installation or repairs made by unqualified persons can result in
hazards to you and others.
Refrigeration work must be performed by a qualified person who
is "F-Gas" registered.
• Installation work must be performed in accordance with the
National Electric Code by qualified and authorized personnel only.
• The information contained in the manual is intended for use by a
qualified service technician familiar with safety procedures and
equipped with the proper tools and test instruments.
• Failure to carefully read and follow all instructions in this manual
can result in equipment malfunction, property damage, personal
injury and/or death.
ENGLISH
Installation
• Do not use a defective or underrated circuit breaker. Use the
correctly rated breaker and fuse. There is risk of fire or electric
shock.
• For electrical work, contact the dealer, seller, a qualified
electrician, or an Authorized Service Center. Do not disassemble
or repair the product by yourself. There is risk of fire or electric
shock.
• Always ground the product as per the wiring diagram. Do not
connect the ground wire to gas or water pipes lightening rod or
telephone ground wire. There is risk of fire or electric shock.
• Install the panel and the cover of control box securely. There is
risk of fire or electric shock due to dust , water etc.
• Use the correctly rated breaker or fuse. There is risk of fire or
electric shock.
4
ENGLISH
IMPORTANT SAFETY INSTRUCTIONS
• Do not modify or extend the power cable. If power cable is
damaged or has deteriorated, then it must be replaced. There is
risk of fire or electric shock.
• For installation, removal or reinstall , always contact the dealer or
an Authorized Service Center. There is risk of fire, electric shock,
explosion, or injury.
• Do not install the product on a defective installation stand. Be
sure that the installation area does not deteriorate with age. It
may cause product to fall.
• Never install the outdoor unit on a moving base or a place from
where it can fall down.
The falling outdoor unit can cause damage or injury or even death
of a person.
• In outdoor unit the step-up capacitor supplies high voltage
electricity to the electrical components. Be sure to discharge the
capacitor completely before conducting the repair work.
A charged capacitor can cause electrical shock.
• When installing the unit, use the installation kit provided with the
product. Otherwise the unit may fall and cause severe injury.
• Indoor/outdoor wiring connections must be secured tightly and
the cable should be routed properly so that there is no force
pulling the cable from the connection terminals. Improper or
loose connections can cause heat generation or fire.
• Safely dispose off the packing materials. Like screws, nails,
batteries, broken things etc after installation or svc and then tear
away and throw away the plastic packaging bags. Children may
play with them and cause injury.
• Be sure to check the refrigerant to be used. Please read the label
on the product. Incorrect refrigerant used can prevent the normal
operation of the unit.
•
Do not turn on the breaker or power under condition that front panel,
cabinet, top cover, control box cover are removed or opened.
Otherwise, it may cause fire, electric shock, explosion or death.
•
Use a vacuum pump or Inert (nitrogen) gas when doing leakage test
or air purge. Do not compress air or Oxygen and do not use
Flammable gases. Otherwise, it may cause fire or explosion.
- There is the risk of death, injury, fire or explosion.
Operation
• When the product is soaked (flooded or submerged) in water ,
contact an Authorized Service Center for repair before using it
again. There is risk of fire or eletric shock.
IMPORTANT SAFETY INSTRUCTIONS
•
Be sure to use only those parts which are listed in the svc parts
5
list. Never attempt to modify the equipment. The use of
inappropriate parts can cause an electrical shock, excessive heat
generation or fire.
• Do not touch , operate, or repair the product with wet hands.
Hold the plug by hand when taking it out. There is risk of electric
shock or fire.
• Do not place a heater or other heating appliances near the power
cable. There is risk of fire and electric shock.
• Do not allow water to run into electric parts. Install the unit away
from water sources. There is risk of fire, failure of the product, or
electric shock.
• Do not store or use or even allow flammable gas or combustibles
near the product. There is risk of fire.
• Do not use the product in a tightly closed space for a long time.
Perform ventilation regularly. Oxygen deficiency could occur and
hence harm your health.
• Do not open the front grille of the product during operation. (Do
not touch the electrostatic filter, if the unit is so equipped.) There
is risk of physical injury, electric shock, or product failure.
• If strange sound, smell or smoke comes from product.
Immediately turn the breaker off or disconnect the power supply
cable. There is risk of electric shock or fire.
• Ventilate the product room from time to time when operating it
together with a stove, or heating element etc. Oxygen deficiency
can occur and hence harm your health.
• When the product is not to be used for a long time, disconnect
the power supply plug or turn off the breaker. There is risk of
product damage or failure, or unintended operation.
• Take care to ensure that nobody especially kids could step on or
fall onto the outdoor unit. This could result in personal injury and
product damage.
• Take care to ensure that power cable could not be pulled out or
damaged during operation. There is risk of fire or electric shock.
• Do not place ANYTHING on the power cable. There is risk of fire
or electric shock.
• When flammable gas leaks, turn off the gas and open a window
for ventilation before turning on the product. Do not use the
telephone or turn switches on or off. There is risk of explosion or
fire.
ENGLISH
6
ENGLISH
Installation
IMPORTANT SAFETY INSTRUCTIONS
CAUTION
!
• Two or more people must lift and transport the product. Avoid
personal injury.
• Do not install the product where it will be exposed to sea wind
(salt spray) directly. It may cause corrosion on the product.
• Install the drain hose to ensure that the condensed water is
drained away properly. A bad connection may cause water
leakage.
• Keep level even when installing the product. To avoid vibration or
noise.
• Do not install the product where the noise or hot air from the
outdoor unit could damage or disturb the neighborhoods. It may
cause a problem for your neighbors and hence dispute.
• Always check for gas (refrigerant) leakage after installation or
repair of product. Low refrigerant levels may cause failure of
product.
• Please install safely at a place that can sufficiently endure the
weight of the product.
If the strength is not sufficient, the product may fall and cause
injury.
Operation
• Do not use the product for special purposes, such as preserving
foods, works of art, etc. It is a consumer air conditioner, not a
precision refrigeration system. There is risk of damage or loss of
property.
• Do not block the inlet or outlet of air flow. It may cause product
failure.
• Use a soft cloth to clean. Do not use harsh detergents, solvents
or splashing water etc. There is risk of fire, electric shock, or
damage to the plastic parts of the product.
• Do not touch the metal parts of the product when removing the
air filter. There is risk of personal injury.
• Do not step on or put anyting on the product. (outdoor units)
There is risk of personal injury and failure of product.
• Always insert the filter securely after cleaning. Clean the filter
every two weeks or more often if necessary. A dirty filter
reduces the efficiency.
IMPORTANT SAFETY INSTRUCTIONS
7
• Do not insert hands or other objects through the air inlet or outlet
while the product is operating. There are sharp and moving parts
that could cause personal injury.
• Be cautious when unpacking and installing the product. Sharp
edges could cause injury.
• If the refrigerant gas leaks during repair, do not touch the leaking
refrigerant gas. The refrigerant gas can cause frostbite (cold
burn).
• Do not tilt the unit when removing or uninstalling it. The
condensed water inside can spill.
• Do not mix air or gas other than the specified refrigerant used in
the system. If air enters the refrigerant system, an excessively
high pressure results, causing equipment damage or injury.
• If the refrigerant gas leaks during the installation, ventilate the
area immediately. Otherwise it can be harmfull for your health.
• Dismantling the unit, treatment of the refrigerant oil and eventual
parts should be done in accordance with local and national
standards.
• Replace all batteries in the remote control with new ones of the
same type. Do not mix old and new batteries or different types of
batteries. There is risk of fire or product failure.
• Do not recharge or disassemble the batteries. Do not dispose off
batteries in a fire. They may burn or explode.
• If the liquid from the batteries gets onto your skin or clothes,
wash it well with clean water. Do not use the remote if the
batteries have leaked. The chemicals in batteries could cause
burns or other health hazards.
• If you eat the liquid from the batteries, brush your teeth and see
doctor. Do not use the remote if the batteries have leaked.
The chemicals in batteries could cause burns or other health
hazards.
• Do not let the air conditioner run for a long time when the
humidity is very high and a door or a window is left open.
Moisture may condense and wet or damage furniture.
• Do not expose your skin or kids or plants to the cool or hot air
draft. This could harm to your health.
• Do not drink the water drained from the product. It is not sanitary
and could cause serious health issues.
• Use a firm stool or ladder when cleaning, maintaining or repairing
the product at height. Be careful and avoid personal injury.
ENGLISH
TABLE OF CONTENTS
8
ENGLISH
TABLE OF CONTENTS
2TIPS FOR SAVING ENERGY
3IMPORTANT SAFETY INSTRUCTIONS
9INSTALLATION
10 INSTALLATION OF OUTDOOR UNIT
11 CONNECTING PIPES
11Preparation of Piping
12Connection of piping - Outdoor
13Forming the piping
14 WIRING CONNECTION
14Electrical Wiring
14Connecting Cables between Indoor Unit and Outdoor Unit
16Connecting the cable to Outdoor Unit