• Please read this installation manual completely before installing the product.
• Installation work must be performed in accordance with the national wiring standards by authorized personnel only.
• Please retain this installation manual for future reference after reading it thoroughly.
P/NO : MFL67448516
Single A Air Conditioner Installation Manual
CONTENTS
Safety Precautions ..............................................................................................3
Model Line up ......................................................................................................6
Installation of Outdoor Unit................................................................................6
Wiring Connection...............................................................................................8
Connecting Pipes ..............................................................................................11
Leakage test and Evacuation ...........................................................................16
Test running .......................................................................................................18
Function..............................................................................................................20
Self-diagnosis Function....................................................................................21
Installation Guide at the Seaside .....................................................................22
2 Air Conditioner
To prevent the injury of the user or other people and property damage, the following instructions must be followed.
n Be sure to read before installing the air conditioner. n Be sure to observe the cautions specified here as they include important items related to safety. n Incorrect operation due to ignoring instruction will cause harm or damage. The seriousness is
classified by the following indications.
n The meanings of the symbols used in this manual are as shown below.
This symbol indicates the possibility of death or serious injury.
This symbol indicates the possibility of injury or damage to properties only.
n Installation
Be sure not to do.
Be sure to follow the instruction.
Safety Precautions
Always perform grounding.
• Otherwise, it may cause elec­trical shock.
Don’t use a Power cable, a plug or a loose socket which is damaged.
• Otherwise, it may cause a fire or electrical shock.
For installation of the prod­uct, always contact the ser­vice center or a professional installation agency.
Otherwise, it may cause a fire, electrical shock, explosion or injury.
Securely attach the electrical part cover to the indoor unit and the service panel to the outdoor unit.
If the electrical part cover of the indoor unit and the service panel of the out­door unit are not attached securely, it could result in a fire or electric shock due to dust, water, etc.
Be sure to install an earth leakage breaker.
• Failure to install an earth leak­age breaker may result in electric shocks or fire.
Do not keep or use flamma­ble gases or combustibles near the air conditioner.
• Otherwise, it may cause a fire or the failure of product.
Ensure that an installation frame of the out­door unit is not damaged due to use for a long time.
• It may cause injury or an accident.
Do not disassemble or repair the product randomly.
• It will cause a fire or electrical shock.
Use a vacuum pump or Inert (nitrogen) gas when doing leakage test or air purge. Do not com­press air or Oxygen and do not use Flammable gases. Otherwise, it may cause fire or explosion.
• There is the risk of death, injury, fire or explosion.
Installation Manual 3
Safety Precautions
4 Air Conditioner
Safety Precautions
Do not install the product at a place that there is concern of falling down.
• Otherwise, it may result in personal injury.
Use caution when unpacking and installing.
• Sharp edges may cause injury.
Do not use the power cord near the heating tools.
• Otherwise, it may cause a fire and electrical shock.
Do not open the suction inlet of the indoor/outdoor unit during operation.
• Otherwise, it may electrical shock and failure.
Do not allow water to run into electrical parts.
• Otherwise, it may cause the failure of machine or electrical shock.
Hold the plug by the head when taking it out.
• It may cause electric shock and damage.
Never touch the metal parts of the unit when removing the filter.
• They are sharp and may cause injury.
Do not step on the indoor/outdoor unit and do not put anything on it.
• It may cause an injury through dropping of the unit or falling down.
Do not share the outlet with other appliances.
• It will cause an electric shock or a fire due to heat genera­tion.
Do not use the damaged Power cable.
• Otherwise, it may cause a fire or electrical shock.
Take care so that the power cord may not be pulled dur­ing operation.
• Otherwise, it may cause a fire or electrical shock.
Unplug the unit if strange sounds, smell, or smoke comes from it.
• Otherwise, it may cause elec­trical shock or a fire.
Keep the flames away.
• Otherwise, it may cause a fire.
Take the power plug out if necessary, holding the head of the plug and do not touch it with wet hands.
• Otherwise, it may cause a fire or electrical shock.
Do not place a heavy object on the power cord.
• Otherwise, it may cause a fire or electrical shock.
When the product is submerged into water, always contact the service center.
• Otherwise, it may cause a fire or electrical shock.
Take care so that children may not step on the outdoor unit.
• Otherwise, children may be seriously injured due to falling down.
n Operation
Installation Manual 5
Safety Precautions
n Installation
Install the drain hose to ensure that drain can be securely done.
• Otherwise, it may cause water leakage.
Install the product so that the noise or hot wind from the outdoor unit may not cause any damage to the neighbors.
• Otherwise, it may cause dispute with the neigh­bors.
Always inspect gas leakage after the instal­lation and repair of product.
• Otherwise, it may cause the failure of product.
Keep level parallel in installing the product.
• Otherwise, it may cause vibration or water leakage.
Avoid excessive cooling and perform venti­lation sometimes.
• Otherwise, it may do harm to your health.
Use a soft cloth to clean. Do not use wax, thinner, or a strong detergent.
• The appearance of the air conditioner may deteriorate, change color, or develop surface flaws.
Do not use an appliance for special purposes such as preserving animals vegetables, pre­cision machine, or art articles.
• Otherwise, it may damage your properties.
Do not place obstacles around the flow inlet or outlet.
• Otherwise, it may cause the failure of appli­ance or an accident.
Do not use the product for special purposes, such as preserving foods, works of art, etc. It is a consumer air conditioner, not a preci­sion refrigeration system
• Otherwise, it may damage your properties.
n Operation
1. Installation Places
• If an awning is built over the unit to prevent direct sunlight or rain exposure, make sure that heat radiation from the condenser is not restricted.
• Ensure that the spaces indicated by arrows around front, back and side of the unit.
• Do not place animals and plants in the path of the warm air.
Take the air conditioner weight into account and select a place where noise and vibration are minimum.
• Select a place so that the warm air and noise from the air conditioner do not disturb neighbors.
More than 300 mm
Model Line up
Installation of Outdoor Unit
Specification of derivative model on the above table is same as base model. (This Manual is written by base model name)
Model Line up
2. Piping length and the elevation
6 Air Conditioner
Unit : mm
FREE JOINT SINGLE OUTDOOR
Model Capacity
Pipe Size Length A(m) Elevation B(m)
Additional
Refrigerant
(g/m)
Gas Liquid Standard Max. Standard Max.
AUUQ30LH1 30 kBtu/h
Ø 15.88(5/8)
Ø 9.52(3/8) 7.5 50 5 30 20
AUUQ36LH1 36 kBtu/h
Ø 15.88(5/8)
Ø 9.52(3/8) 7.5 50 5 30 20
AUUQ42LH1 42 kBtu/h
Ø 15.88(5/8)
Ø 9.52(3/8) 7.5 50 5 30 20
AUUQ48LH1 48 kBtu/h
Ø 15.88(5/8)
Ø 9.52(3/8) 7.5 50 5 30 20
AUUQ54LH1 54 kBtu/h
Ø 19.05(3/4)
Ø 9.52(3/8) 7.5 50 5 30 40
Base Model Derivative Model
AUUQ30LH1
ATUQ30LMLE3 / ABUQ30LGLA0
AVUQ30LKLA0 / APUQ30LRA1
AUUQ36LH1
ATUQ36LMLE3 / ABUQ36LGLA0
AVUQ36LKLA0 / APUQ36LRA1
AUUQ42LH1
ATUQ42LMLE3 / ABUQ42LRLA0
AVUQ42LLLA0 / APUQ42LTA1
AUUQ48LH1
ATUQ48LMLE3 / ABUQ48LRLA0
AVUQ48LLLA0 / APUQ48LTA1
AUUQ54LH1 ATUQ54LMLE3 / ABUQ54LRLA0
More than 300 mm
Fence or
obstacles
Sunroof
More than 700 mm
More than
More than 300 mm
300 mm
More than 600 mm
Installation Manual 7
Installation of Outdoor Unit
Night Silent Operation setting
1. Open the Side panel or Top Cover of outdoor unit.
2. Set the SW01N.
3. Close the Side panel or Top Cover.
SW01N
If installed tube is shorter than 7.5 m, additional charging is not necessary. Additional Refrigerant = (A -7.5) x Additional refrigerant (g)
CAUTION:
• Capacity is based on standard length and maximum allowance length is on the basis of reliability.
• Improper refrigerant charge may result in abnormal cycle.
Indoor unit
Outdoor unit
A
B
Outdoor unit
Indoor unit
A
B