LG ATNW18GPLS1 Owner’s Manual

<![if ! IE]>

<![endif]>FRANÇAIS ENGLISH

INSTALLATION MANUAL

AIR

CONDITIONER

Please read this installation manual completely before installing the product. Installation work must be performed in accordance with the national wiring standards by authorized personnel only.

Please retain this installation manual for future reference after reading it thoroughly.

CEILING CASSETTE

www.lg.com

P/NO : MFL68500204

<![if ! IE]>

<![endif]>ENGLISH

2

TIPS FOR SAVING ENERGY

 

 

TIPS FOR SAVING ENERGY

Here are some tips that will help you minimize the power consumption when you use the air conditioner. You can use your air conditioner more efficiently by referring to the instructions below:

Do not cool excessively indoors. This may be harmful for your health and may consume more electricity.

Block sunlight with blinds or curtains while you are operating the air conditioner.

Keep doors or windows closed tightly while you are operating the air conditioner.

Adjust the direction of the air flow vertically or horizontally to circulate indoor air.

Speed up the fan to cool or warm indoor air quickly, in a short period of time.

Open windows regularly for ventilation as the indoor air quality may deteriorate if the air conditioner is used for many hours.

Clean the air filter once every 2 weeks. Dust and impurities collected in the air filter may block the air flow or weaken the cooling / dehumidifying functions.

For your records

Staple your receipt to this page in case you need it to prove the date of purchase or for warranty purposes. Write the model number and the serial number here:

Model number :

Serial number :

You can find them on a label on the side of each unit.

Dealer’s name :

Date of purchase :

SAFETY PRECAUTIONS 3

IMPORTANT SAFETY INSTRUCTIONS

READ ALL INSTRUCTIONS BEFORE USING THE APPLIANCE.

Always comply with the following precautions to avoid dangerous situations and ensure peak performance of your product

! WARNING

It can result in serious injury or death when the directions are ignored

! CAUTION

It can result in minor injury or product damage when the directions are ignored

! WARNING

Installation or repairs made by unqualified persons can result in hazards to you and others.

Installation MUST conform with local building codes or, in the absence of local codes, with the Nation Electrical Code NFPA 70/ANSI C1-1003 or current edition and Canadian Electrical Code Part1 CSA C.22.1.

The information contained in the manual is intended for use by a qualified service technician familiar with safety procedures and equipped with the proper tools and test instruments.

Failure to carefully read and follow all instructions in this manual can result in equipment malfunction, property damage, personal injury and/or death.

Installation

Always perform grounding. - Otherwise, it may cause electrical shock.

Don’t use a power cable, a plug or a loose socket which is damaged. - Otherwise, it may cause a fire or electrical shock.

For installation of the product, always contact the service center or a professional installation agency. - Otherwise, it may cause a fire, electrical shock, explosion or injury.

Securely attach the electrical part cover to the indoor unit and the service panel to the outdoor unit.

-If the electrical part cover of the indoor unit and the service panel of the outdoor unit are not attached securely, it could result in a fire or electric shock due to dust, water, etc.

Always install an air leakage breaker and a dedicated switching board. - No installation may cause a fire and electrical shock.

Do not keep or use flammable gases or combustibles near the air conditioner. - Otherwise, it may cause a fire or the failure of product.

Ensure that an installation frame of the outdoor unit is not damaged due to use for a long time.

-It may cause injury or an accident.

Do not disassemble or repair the product randomly. - It will cause a fire or electrical shock.

Do not install the product at a place that there is concern of falling down. - Otherwise, it may result in personal injury.

Use caution when unpacking and installing. - Sharp edges may cause injury.

Operation

Do not share the outlet with other appliances. - It will cause an electric shock or a fire due to heat generation.

Do not use the damaged power cable. - Otherwise, it may cause a fire or electrical shock.

<![if ! IE]>

<![endif]>ENGLISH

4 SAFETY PRECAUTIONS

<![if ! IE]>

<![endif]>ENGLISH

• Do not modify or extend the power cable randomly. - Otherwise, it may cause a fire or electrical

 

 

shock.

 

• Take care so that the power cable may not be pulled during operation. - Otherwise, it may cause a

 

fire or electrical shock.

 

• Unplug the unit if strange sounds, smell, or smoke comes from it. - Otherwise, it may cause electri-

 

cal shock or a fire.

 

• Keep the flames away. - Otherwise, it may cause a fire.

 

• Take the power plug out if necessary, holding the head of the plug and do not touch it with wet

 

hands. - Otherwise, it may cause a fire or electrical shock.

 

• Do not use the power cable near the heating tools. - Otherwise, it may cause a fire and electrical

 

shock.

 

• Do not open the suction inlet of the indoor/outdoor unit during operation. - Otherwise, it may electri-

 

cal shock and failure.

 

• Do not allow water to run into electrical parts. - Otherwise, it may cause the failure of machine or

 

electrical shock.

 

• Hold the plug by the head when taking it out. - It may cause electric shock and damage.

 

• Never touch the metal parts of the unit when removing the filter. - They are sharp and may cause

 

injury.

 

• Do not step on the indoor/outdoor unit and do not put anything on it. - It may cause an injury through

 

dropping of the unit or falling down.

 

• Do not place a heavy object on the power cable. - Otherwise, it may cause a fire or electrical shock.

 

• When the product is submerged into water, always contact the service center. - Otherwise, it may

 

cause a fire or electrical shock.

 

• Take care so that children may not step on the outdoor unit. - Otherwise, children may be seriously

 

injured due to falling down.

! CAUTION

Installation

Install the drain hose to ensure that drain can be securely done. - Otherwise, it may cause water leakage.

Install the product so that the noise or hot wind from the outdoor unit may not cause any damage to the neighbors. - Otherwise, it may cause dispute with the neighbors.

Always inspect gas leakage after the installation and repair of product. - Otherwise, it may cause the failure of product.

Keep level parallel in installing the product. - Otherwise, it may cause vibration or water leakage.

Operation

Avoid excessive cooling and perform ventilation sometimes. - Otherwise, it may do harm to your health.

Use a soft cloth to clean. Do not use wax, thinner, or a strong detergent. - The appearance of the air conditioner may deteriorate, change color, or develop surface flaws.

Do not use an appliance for special purposes such as preserving animals vegetables, precision machine, or art articles. - Otherwise, it may damage your properties.

Do not place obstacles around the flow inlet or outlet. - Otherwise, it may cause the failure of appliance or an accident.

 

 

 

 

TABLE OF CONTENTS

5

TABLE OF CONTENTS

 

 

 

 

 

 

 

 

 

2

TIPS FOR SAVING

12

INSTALLATION OF DEC-

 

ENERGY

 

 

ORATIVE PANEL(ACCES-

3

IMPORTANT SAFETY

 

 

SORY)

 

 

14

TEST RUNNING

 

 

INSTRUCTIONS

 

6

INSTALLATION PLACES

15

INSTALLATION

 

7

THE INDOOR UNIT

 

 

INSTRUCTIONS

 

15

Installer Setting - Setting Address of

 

 

INSTALLATION

 

 

 

 

Central Control

 

8

Indoor Unit Drain Piping

15

Installer Setting - Checking Address of

9

Wiring Connection

 

 

Central Control

 

 

 

16

Installer Setting -How to enter installer

11

OPERATING INSTRUC-

 

 

setting mode

 

17

Installer Setting - Installer Setting

 

 

TION

 

 

 

 

Code Table

 

11 How to insert the Batteries

11Wireless Remote Controller Maintenance

11 Operating Method

<![if ! IE]>

<![endif]>ENGLISH

<![if ! IE]>

<![endif]>ENGLISH

6 INSTALLATION PLACES

INSTALLATION PLACES

-There should not be any heat source or steam near the unit.

-There should not be any obstacles to prevent the air circulation.

-A place where air circulation in the room will be good.

-A place where drainage can be easily obtained.

-A place where noise prevention is taken into consideration.

-Do not install the unit near the door way.

-Ensure the spaces indicated by arrows from the wall, ceiling, or other obstacles.

-The indoor unit must keep the maintenance space.

Ceiling

 

 

At least 10

<![if ! IE]>

<![endif]>less

 

 

 

 

 

 

 

Ceiling Board

 

 

 

 

 

<![if ! IE]>

<![endif]>or

Ceiling Board

 

 

 

 

 

 

 

 

 

 

<![if ! IE]>

<![endif]>800

 

<![if ! IE]>

<![endif]>less

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

<![if ! IE]>

<![endif]>or

500 or

<![if ! IE]>

<![endif]>1000

<![if ! IE]>

<![endif]>or more

 

 

<![if ! IE]>

<![endif]>4200or less (TM/TN)

 

500 or

<![if ! IE]>

<![endif]>300

more

 

<![if ! IE]>

<![endif]>3600or less (TP)

 

more

 

<![if ! IE]>

<![endif]>Atleast 1800

 

 

 

 

 

 

 

 

 

 

Unit : mm

 

 

 

 

 

Floor

 

 

 

*Please use an annexed sheet or the corrugated cardboard on the bottom of packing as installation sheet.

 

Or

Annexed sheet

Packing corrugated

 

cardboard on the

 

bottom

*When using the bottom sheet, please use it after separating the installation sheet from packing of the product floor by using a knife etc as a picture below.

THE INDOOR UNIT INSTALLATION

7

 

THE INDOOR UNIT INSTALLATION

Ceiling

Level gauge

Ceiling board

1Such places as restaurants and kitchen where considerable amount of oil steam and flour is generated. These may cause heat exchange efficiency reduction, or water drops, drain pump mal-function. In these cases, take the following actions;

-Make sure that ventilation fan is enough to cover all noxious gases from this place.

-Ensure enough distance from the cooking room to install the air conditioner in such a place where it may not suck oily steam.

TP/TN/TM Series

 

875(Ceiling opening)

 

 

 

787(Hanging bolt)

 

 

<![if ! IE]>

<![endif]>671

840 Unit size

<![if ! IE]>

<![endif]>684(Hanging bolt)

<![if ! IE]>

<![endif]>875(Ceiling opening)

<![if ! IE]>

<![endif]>840 Unit size

 

 

Unit:mm

-Select and mark the position for fixing bolts and piping hole.

-Decide the position for fixing bolts slightly tilted to the drain direction after considering the direction of drain hose.

-Drill the hole for anchor bolt on the wall.

Air conditioner

Take enough distance

Cooking table

Use the ventilation fan for smoke-collecting hood with sufficient capacity.

2Avoid installng air conditioner in such places where cooking oil or iron powder is generated.

3Avoid places where inflammable gas is generated.

4Avoid place where noxious gas is generated.

5Avoid places near high frequency generators.

!CAUTION

This air-conditioner uses a drain pump.

Install the unit horizontally using a level gauge.

During the installation, care should be taken not to damage electric wires.

!NOTE

<![if ! IE]>

<![endif]>ENGLISH

Avoid the following installation location.

<![if ! IE]>

<![endif]>ENGLISH

8

THE INDOOR UNIT INSTALLATION

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Ceiling

 

 

Hanging bolt

Keep the length of the bolt

Air Conditioner body

<![if ! IE]>

<![endif]>150mm

 

Nut

Flat washer for M10

 

(W3/8 or M10)

from the bracket to 40mm

 

 

 

(W3/8 or M10)

(accessory)

Ceiling board

 

 

 

 

Spring washer

 

 

 

 

 

 

 

 

 

 

(M10)

 

 

Keep the length of 15~18mm

Ceiling

 

 

Flat washer for M10

between the air conditioner

 

 

bottom surface and the ceiling

board

 

 

(accessory)

 

surface

Set screw of

 

 

 

Nut

 

Paper model

 

 

 

(W3/8 or M10)

 

for installation

paper model (4 pieces)

 

 

 

Adjust the

Open the ceiling board

The following parts is option.

same height

 

 

along the outer edge of the

Hanging Bolt

- W 3/8 or M10

 

 

paper model

 

 

 

 

 

Nut

- W 3/8 or M10

Spring Washer - M10

Plate Washer - M10

Drill the piping hole on the wall slightly tilted to the outdoor side using a Ø 70 hole-core drill.

! CAUTION

Tighten the nut and bolt to prevent unit falling.

 

Wall

Indoor

Outdoor

 

<![if ! IE]>

<![endif]>5~7mm

Indoor Unit Drain Piping

-Drain piping must have down-slope (1/50 to 1/100): be sure not to provide up-and-down slope to prevent reversal flow.

-During drain piping connection, be careful not to exert extra force on the drain port on the indoor unit.

-The outside diameter of the drain connection on the indoor unit is 32mm.

Piping material: Polyvinyl chloride pipe VP25 and pipe fittings

-Be sure to execute heat insulation on the drain piping.

-Install the drain raising pipes at a right angle to the indoor unit and no more than 300mm from the unit.

Pipe clamp

Upward

routing

 

 

not allowed

Indoor unit

 

Maintenance drain port

THE INDOOR UNIT INSTALLATION

9

 

HEAT INSULATION

300mm or less

1 -1.5m

 

<![if ! IE]>

<![endif]>700 or less

 

Drain raising pipe

Clamp metal(attached)

Drain hose(attached)

Heat insulation material: Polyethylene foam with thickness more than 8 mm.

Drain test

-Use the heat insulation material for the refrigerant piping which has an excellent heat-resistance (over 120°C).

-Precautions in high humidity circumstance: This air conditioner has been tested according to the "KS Standard Conditions with Mist" and confirmed that there is not any default. However, if it is operated for a long time in high humid atmosphere (dew point temperature: more than 23°C), water drops are liable to fall. In this case, add heat insulation material according to the following procedure:

The air conditioner uses a drain pump to drain water.

Use the following procedure to test the drain pump operation:

-Connect the main drain pipe to the exterior and leave it provisionally until the test comes to an end.

-Feed water to the flexible drain hose and check the piping for leakage.

-Be sure to check the drain pump for normal operating and noise when electrical wiring is complete.

-When the test is complete, connect the flexible drain hose to the drain port on the indoor unit.

 

Fastening band

 

(accessory)

Indoor

Refrigerant

unit

piping

Thermal insulator (accessory)

-Heat insulation material to be prepared...

Adiabatic EPDM or NBR with thickness 10 to 20mm.

-Stick glass wool on all air conditioners that are located in ceiling atmosphere.

Feed water

Flexible drain hose

(accessory)

 

 

Main

 

drain pipe

Drain Pump

Drain

Glue the joint

port

 

Drain hose connection

 

Use the clip (accessory)

Drain pan

 

 

Wiring Connection

-Open the control box cover and connect the Remote controller cable and Indoor power wires.

-Remove the control box cover for electrical connection between the indoor and outdoor unit. (Remove screws )

-Use the cord clamper to fix the cable.

! CAUTION

The supplied flexible drain hose should not be curved, neither screwed. The curved or screwed hose may cause a leakage of water.

Hanger

Max 300mm

distance

Hanger Bracket

 

1~15m

1/50~1/100 slope

 

 

Metal

 

<![if ! IE]>

<![endif]>700mmMax

clamp

 

 

Flexible drain hose

 

Insulation

 

 

 

 

Remote

 

 

controller

 

 

cable

Connection

 

1

cable

1

 

between the

Control box cover

indoor unit and

 

the outdoor

 

(On which the

unit

 

Electric Wiring

Connection is put)

<![if ! IE]>

<![endif]>ENGLISH

<![if ! IE]>

<![endif]>ENGLISH

10 THE INDOOR UNIT INSTALLATION

! CAUTION

The connecting cable connected to the indoor and outdoor unit should be complied with the following specifications (This equipment shall be provided with a cable set complying with the national regulation). (Rubber insulation, type H05RN-F approved by HAR or SAA).

10±3 mm

35±5

mm

 

GN/YL

NORMAL

20

mm

 

CROSS-SECTIONAL

AREA 0.75 mm2

Precautions when laying power wiring

Use round pressure terminals for connections to the power terminal block.

Round pressure terminal

Power wire

When none are available, follow the instructions below.

-Do not connect wiring of different thicknesses to the power terminal block. (Slack in the power wiring may cause abnormal heat.)

-When connecting wiring which is the same thickness, do as shown in the figure below.

Connect same thickness wiring to both sides.

If the supply cable is damaged, it must be replaced by a special cable or assembly available from the manufacturer of its service agent.

! CAUTION

The Power cable connected to the unit should be selected according to the following specifications.

 

It is forbidden to

 

 

 

It is forbidden to

 

 

 

 

connect two to one

 

 

 

connect wiring of

 

side.

 

 

different thicknesses.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

-For wiring, use the designated power wire and connect firmly, then secure to prevent outside pressure being exerted on the terminal block.

-Use an appropriate screwdriver for tightening the terinal screws. A screwdriver with a small head will strip the head and make proper tighterning impossible.

-Over-tightening the terminal screws may break them.

REMOTE CONTROLLER INSTALLATION 11

OPERATING INSTRUCTION

How to insert the Batteries

1Remove the battery cover by pulling it according to the arrow direction.

2Insert new batteries making sure that the

(+) and (-) of battery are installed correctly.

3Reattach the cover by sliding it back into position.

!NOTE

Always use/replace both batteries of same type.

If the system is not to be used for a long time, remove the batteries to save their working life.

If the display screen of remote controller starts, fading replace both of the batteries.

Wireless Remote Controller

Maintenance

1Choose a suitable place where its safe & easy to reach.

2Fix the holder to wall etc with the supplied screws firmly.

3Slide the remote controller inside the holder.

!NOTE

Remote controller should never be exposed to direct sunlight.

Signal transmitter & receiver should always be clean for proper communication. Use a soft cloth to clean them.

In case some other appliances also get operated with remote control, change their position or consult your serviceman.

Operating Method

1 The signal receiver is inside the unit.

2Aim the remote controller towards the unit to operate it. There should not be any blockage in between.

<![if ! IE]>

<![endif]>ENGLISH

<![if ! IE]>

<![endif]>ENGLISH

12 INSTALLATION OF DECORATIVE PANEL(ACCESSORY)

INSTALLATION OF DECORATIVE PANEL(ACCESSORY)

The decorative panel has its installation direction.

Before installing the decorative panel, always remove the paper template.

1Remove the packing and take out air inlet grille from front panel.

Front grille

4Insert two screws on diagonal corners of panel. Do not tighten the bolts completely. (The fixing screws are included in the indoor unit box.)

Check the alignment of panel with the ceiling. Height can be adjusted using hanging bolts as shown in picture. Insert the other two screws and tighten all screws completely.

2 Remove the Corner covers of the panel.

Coner cover

3 Fit the panel on the unit by inserting hooks

5 Fit the corner covers.

as shown in picture.

 

Hook clip

Hook

LG ATNW18GPLS1 Owner’s Manual

INSTALLATION OF DECORATIVE PANEL(ACCESSORY) 13

6 Open two screws of control panel cover.

9 Install the air inlet grille and Filter on the

 

panel.

Screw

7Connect one display connector and two vane control connectors of front panel to indoor unit PCB.

The position marking on PCB is as: Display connector : CN-DISPLAY Vane control connector: CN-VANE 1,2

CN-VANE 1,2 CN-DISPLAY

8 Close the cover for control box.

! CAUTION

Install certainly the decorative panel. Cool air leakage causes sweating. Water drops fall.

Good example

Air conditioner unit

Ceiling

board

Fit the insulator (this part) and Decorative panel be careful for cool air leakage

Bad example

Air conditioner unit

 

 

Cool air leakage

 

(no good)

 

Ceiling

 

board

 

Decorative

 

panel

<![if ! IE]>

<![endif]>ENGLISH

<![if ! IE]>

<![endif]>ENGLISH

14 TEST RUNNING

TEST RUNNING

PRECAUTIONS IN TEST RUN

-The initial power supply must provide at least 90 % of the rated voltage.

Otherwise, the air conditioner should not be operated.

Connection of power supply

-Connect the power supply cable to the independent power supply.

Circuit breaker is required.

-Operate the unit for 15 minutes or more.

!CAUTION

For test run, carry out the cooling operation firstly even during heating season. If heating operation is carried out firstly, it leads to the trouble of compressor. Then attention must be paid.

Carry out the test run more than 5 minutes without fail.

(Test run will be cancelled 18 minutes later automatically)

-To cancel the test run, press any button.

CHECK THE FOLLOWING ITEMS WHEN INSTALLATION IS COMPLETED

-After completing work, be sure to measure and record trial run properties, and store measured data, etc.

-Measuring items are room temperature, outside temperature, suction temperature, blow out temperature, wind velocity, wind volume, voltage, current, presence of abnormal vibration and noise, operating pressure, piping temperature, compressive pressure.

-As to the structure and appearance, check following items.

* Is the circulation of air adequate?

*Is the draining smooth?

*Is the heat insulation complete (refrigerant and drain piping)?

*Is there any leakage of refrigerant?

*Is the remote controller switch operated?

*Is there any faulty wiring?

*Are not terminal screws loosened?

M4......

118 N·cm{12 kgf·cm}

M5......

196 N·cm{20 kgf·cm}

M6......

245 N·cm{25 kgf·cm}

M8......

588 N·cm{60 kgf·cm}

Evaluation of the performance

-Measure the temperature of the intake and discharge air.

-Ensure the difference between the intake temperature and the discharge one is more than 8 °C (Cooling) or reversely (Heating).

Thermometer

INSTALLATION INSTRUCTIONS 15

INSTALLATION INSTRUCTIONS

Installer Setting - Setting Address of Central Control

1 With the MODE button pressed, press the RESET button.

2

By using the temperature setting button, set the indoor unit address.

- Setting range : 00 ~ FF

Group No.

Indoor Unit No.

3 After setting the address, press the ON/OFF button toward the indoor unit 1 time.

4 The indoor unit will display the set address to complete the address setting.

- The address display time and method can differ by the indoor uint type.

5 Reset the remote controller to use the general operation mode.

Installer Setting - Checking Address of Central Control

1 When FUNCTION button pressed, press RESET button

2 Press the ON/OFF button toward the indoor unit 1 time, and the indoor unit will display the set address in the display window.

- The address display time and method can differ by the indoor unit type.

3 Reset the remote controller to use the general operation mode.

<![if ! IE]>

<![endif]>ENGLISH

<![if ! IE]>

<![endif]>ENGLISH

16 INSTALLATION INSTRUCTIONS

Installer Setting -How to enter installer setting mode

! CAUTION

Installer setting mode is to set the detail function of the remote controller.

If the installer setting mode is not set correctly, it can cause problems to the product, user injury or property damage. This must be set by an certificated installer, and any installation or change that is carried out by a non-certificated person should be responsible for the results. In this case, free service cannot be provided.

1 When JET COOL button pressed, press RESET button

2 By using the TEMPERATURE SETTING button, set function code and setting value. (Please refer the Installer Setting Code Table.)

Function Code

Setting Code

3 Press the ON/OFF button toward the indoor unit 1 time.

4 Reset the remote controller to use the general operation mode.

* Refer to the Installer Setting Code Table on the next page.

INSTALLATION INSTRUCTIONS 17

Installer Setting - Installer Setting Code Table

Installer Setting Code Table

No.

Function

Function Code

 

Setting Value

Remote

 

Controller LCD

 

 

 

 

 

 

 

 

 

 

 

0

Mode Override

0

0

: Set to Master

00

1

: Set to Slave

01

 

 

 

 

 

 

 

 

 

 

 

 

1

: Standard

11

1

Ceiling Height

1

2 : Low

12

Selection

3 : High

13

 

 

 

 

 

4

: Super High

14

 

 

 

0

: Set to Master

20

 

 

 

 

 

 

Group Control

2

1 : Set to Slave

21

2

 

 

2

: Check Master/Slave

22

 

 

 

 

 

 

 

3

: Set to Auxiliary heater

23

 

 

 

 

Auxiliary heater

2

4 : Cancel Auxiliary heater

24

 

 

 

 

 

 

 

 

 

2

: Check Auxiliary heater Installation

25

Mode Override

This Function is only for Non-Auto Changeover H/P model.

Ceiling Height Selection

Indoor unit connected to wired remote controller operate as wired remote controller setting.

Group Control

This function is only for group control. Please don’t set this function in case of non-group control. After setting Group Control of the product, turn off the power then turn it back on after 1 minute.

Auxiliary heater

This function is only applied to models with Auxiliary Heater function being activated.

<![if ! IE]>

<![endif]>ENGLISH

18

<![if ! IE]>

<![endif]>ENGLISH

<![if ! IE]>

<![endif]>FRANÇAIS

MANUEL D'INSTALLATION

CLIMATISEUR

Veuillez lire ce manuel dans son intégralité avant d'installer le climatiseur. L'installation doit être effectuée conformément aux normes électriques nationales par un personnel agréé uniquement.

Après avoir lu ce manuel attentivement, conservez-le pour pouvoir vous y reporter ultérieurement.

CASSETTE 4 VOIESTYPE CASSETTE

www.lg.com

<![if ! IE]>

<![endif]>FRANÇAIS

2

ASTUCES POUR ECONOMISER L’ENERGIE

 

 

ASTUCES POUR ECONOMISER L’ENERGIE

Nous vous donnons ici quelques astuces qui vous permettront de minimiser la consommation d’énergie lorsque vous utilisez le climatiseur. Vous pouvez utiliser un climatiseur de manière plus efficace en vous référant aux instructions ci-dessous.

Evitez un refroidissement excessif des unités intérieures. Une telle application pourrait représenter un danger pour votre santé et entraîner une plus grande consommation de courant.

Evitez d'exposer le climatiseur aux rayons solaires à l’aide des rideaux ou des persiennes lorsqu’il est en marche.

Maintenez les portes et les fenêtres complètement fermées lorsque vous utilisez le climatiseur.

Ajustez le sens du débit d’air verticalement ou horizontalement pour permettre la circulation de l’air intérieur.

Accélérez le ventilateur pour refroidir ou réchauffer rapidement l’air intérieur en peu de temps.

Ouvrez régulièrement des fenêtres pour des besoins d’aération étant donné que la qualité de l'air intérieur peut se détériorer si vous utilisez le climatiseur pendant plusieurs heures.

Ouvrez régulièrement des fenêtres pour des besoins d’aération étant donné que la qualité de l'air intérieur peut se détériorer si vous utilisez le climatiseur pendant plusieurs heures.

Pour vos archives

Agrafez votre reçu sur cette page dans le cas où vous en avez besoin pour prouver la date d’achat ou pour des besoins de garantie. Ecrivez le numéro du modèle et le numéro de série ici:

Numéro du modèle:

Numéro de série:

Ces numéros sont disponibles sur l’étiquette de chaque côté du climatiseur.

Nom du distributeur:

Date d’achat:

CONSIGNES DE SECURITE IMPORTANTES

3

 

CONSIGNES DE SECURITE IMPORTANTES

LISEZ ENTIEREMENT LES INSTRUCTIONS AVANT D’UTILISER L’APPAREIL.

Respectez toujours les consignes suivantes pour éviter des situations dangereuses et garantir une performance optimale de votre produit.

! ATTENTION

Le non respect de ces consignes peut être fatal ou provoquer des blessures graves.

! AVERTISSEMENT

Le non respect de ces consignes peut provoquer des blessures légères ou endommager le produit.

!ATTENTION

Les travaux d’installation ou de dépannage effectués par des personnes non qualifiées peuvent vous exposer aux risques en même temps que les autres personnes.

L’installation DOIT être conforme aux codes de construction locaux, et dans le cas où il n’en existe pas, au Code National de l’Electricité NFPA 70/ANSI C1-1003 ou à l’édition actuelle et au Code Canadien de l’Electricité, Partie 1 CSA C.22.1.

Les informations contenues dans ce manuel sont destinées à un technicien de maintenance qualifié qui maîtrise les consignes de sécurité et dispose d’outils et d’instruments de test appropriés.

Le fait de ne pas lire attentivement et de ne pas respecter les instructions de ce manuel peut provoquer un dysfonctionnement de l’équipement, des dégâts matériels, des blessures individuelles et/ou la mort.

Installation

Mettez toujours à terre le produit. - Autrement, vous risquez de provoquer un choc électrique.

N'utilisez pas un cordon d’alimentation, une fiche d’alimentation ou une prise de courant endommagés. - Autrement, vous risquez de causer un incendie ou un choc électrique.

Pour l'installation du produit, contactez toujours le centre après-vente ou un service d’installation professionnel. - Autrement, vous risquez de provoquer un incendie, un choc électrique, une explosion ou des blessures.

Fixez correctement le couvercle de protection des pièces électriques à l’unité intérieure et le panneau de service à l’unité extérieure. - Si le couvercle de protection des pièces électriques de l’unité intérieure et le panneau de service de l’unité extérieure ne sont pas bien fixés, cela peut provoquer un incendie ou un choc électrique dus à la poussière, à l’eau, etc.

Installez toujours un interrupteur pour fuites d’air et un tableau électrique spécialisé. - Ne pas le faire peut provoquer un incendie ou un choc électrique.

Ne rangez ni n’utilisez de gaz inflammable ni de combustibles près du climatiseur. - Autrement, vous risquez de provoquer un incendie ou le mauvais fonctionnement de l’appareil.

Assurez-vous que le cadre d’installation de l’unité extérieure ne soit pas endommagé à cause d’une utilisation prolongée. - Cela peut provoquer des blessures ou un accident.

Ne démontez ni ne réparez le produit en n’importe quel point. - Cela peut provoquer un incendie ou un choc électrique.

N'installez pas le produit dans un endroit d’où il puisse tomber. - Autrement, vous risquez de blesser quelqu’un.

Soyez prudent pendant le déballage et l’installation. - Les bords aiguisés peuvent provoquer des blessures.

<![if ! IE]>

<![endif]>FRANÇAIS

4

CONSIGNES DE SECURITE IMPORTANTES

 

 

Fonctionnement

 

• Ne partagez pas la prise avec d’autres appareils. - Cela peut provoquer un choc électrique ou un incendie à cause de la

 

génération de chaleur.

 

• N'utilisez pas un cordon d’alimentation endommagé. - Vous risquez de provoquer un incendie ou un choc électrique.

<![if ! IE]>

<![endif]>FRANÇAIS

• Ne modifiez ni ne rallongez le cordon d’alimentation en n’importe quel point. - Autrement, vous risquez de provoquer

 

 

un incendie ou un choc électrique.

 

• Veillez à ce que le cordon d’alimentation ne soit pas tiré en cours de fonctionnement. - Autrement, vous risquez de

 

provoquer un incendie ou un choc électrique.

 

• Débranchez l’unité si vous constatez la présence de bruits étranges, d’odeurs ou de fumée provenant de l’appareil. -

 

 

Autrement, vous risquez de provoquer un incendie ou un choc électrique.

 

• Évitez le contact avec des flammes. - Autrement, vous risquez de provoquer un incendie.

 

• A l’occasion, débranchez la fiche d’alimentation, en la prenant par la tête, et ne la touchez pas avec les mains

 

mouillées. - Autrement, vous risquez de provoquer un incendie ou un choc électrique.

 

• N`utilisez pas le cordon d’alimentation près des dispositifs de chauffage. - Autrement, vous risquez de provoquer un

 

incendie ou un choc électrique.

 

• N’ouvrez pas l’ouverture d’aspiration de l’unité intérieure/extérieure en cours de fonctionnement. - Autrement, vous

 

risquez de provoquer un choc électrique ou un mauvais fonctionnement.

 

• Ne permettez pas que de l’eau entre en contact avec les pièces électriques. - Autrement, vous risquez de provoquer

 

le mauvais fonctionnement de l’appareil ou un choc électrique.

 

• Prenez la fiche d’alimentation par la tête lorsque vous la débranchez. - Cela peut provoquer un choc électrique ou des

 

dommages.

 

• Ne touchez jamais les pièces métalliques de l’unité lorsque vous retirez le filtre. - Elles sont aiguisées et peuvent

 

provoquer des blessures.

 

• Ne montez sur l’appareil ni n’y placez aucun objet. - Autrement, vous risquez de vous blesser en tombant de l’appareil.

 

• Ne placez pas d’objet lourd sur le cordon d’alimentation. - Autrement, vous risquez de provoquer un incendie ou un

 

choc électrique.

 

• Contactez le service après-vente si le produit est submergé dans l’eau. - Autrement, vous risquez de causer un

 

incendie ou un choc électrique.

 

• Veillez à ce que les enfants ne montent pas sur l’unité extérieure. - Autrement, ils risquent d’être sérieusement

 

blessés en tombant.

! AVERTISSEMENT

Installation

Installez le raccord de drainage de manière à assurer un drainage convenable. - Autrement, vous risquez de causer une fuite d'eau.

Installez le produit de sorte que vos voisins ne soient pas dérangés par le bruit ou par le vent chaud venant de l'unité extérieure. - Autrement, vous risquez de susciter des querelles avec les voisins.

Après l’installation ou la réparation du produit, veillez toujours à vérifier qu’il n’y ait pas de fuite de gaz. - Autrement, vous risquez de causer le mauvais fonctionnement de l'appareil.

Maintenez le niveau lors de l’installation du produit. - Autrement, vous risquez de provoquer des vibrations ou une fuite d'eau.

Fonctionnement

Évitez le refroidissement excessif et aérez parfois. - Autrement, vous risquez de nuire à votre santé.

Utilisez un tissu doux pour nettoyer l’appareil. N'employez ni de cire, ni de diluant ni de détergent fort.

-Autrement, vous risquez de détériorer l’aspect de l’appareil, changer sa couleur ou provoquer des défauts sur sa surface.

N'utilisez pas le produit à des buts particuliers, tels que la préservation d’animaux, de plantes, de dispositifs de précision ou d’objets d'art, etc. - Autrement, vous risquez d’endommager vos biens.

Ne placez pas d'obstacles autour de l'entrée ou de la sortie du flux d’air. - Autrement, vous risquez de provoquer le mauvais fonctionnement de l’appareil ou un accident.

Loading...
+ 50 hidden pages