Lg As-w093wsa7, As-w123bsa7, Ls120hev, Ls090hev Owner's Manual

Page 1
Room Air Conditioner
SVC MANUAL(Exploded View)
MODEL : AS-W093WSA7(LS090HEV) AS-W123BSA7(LS120HEV)
CAUTION
Before Servicing the unit, read the safety precautions in General SVC manual. Only for authorized service personnel.
Internal Use Only
Page 2
- 2 -
Copyright ©2011 LG Electronics. Inc. All right reserved. Only for training and service purposes
LGE Internal Use Only
1. Specification
Note:
O
: Applied, - : No relation
*
For circuit breaker rating, please conform to local standards wherever necessary.
h
Some of functions are slightly different depending upon models.
h
The specification may be subject to change without notic for purpose of improve­ment.
Model
Set
Indoor Unit
Outdoor Unit
Cooling Capacity
kW
Btu/h
Heating Capacity
kW
Btu/h Power Input Cooling/Heating W Running Current Cooling/Heating A Staring Current Cooling/Heating A
EER/COP
W/W
Btu/h.W SEER HSPF Power Supply Ø / V / Hz Power Factor %
Air Flow Rate
Inddor, Max m3/min(CFM) Outdoor,Max m3/min(CFM)
Moisture Removal l/h (pts/hr)
Sound Level
Indoor,H/M/L/S-Low dB(A)+3
Outdoor,Max dB(A)+3 Refrigerant & Charge(at 7.5m) g Additional Refrigerant Charge g/m(oz/ft)
Compressor
Type
Model
Motor Type
Oil Type
Oil Charge cc
O.L.P Name
Fan(Indoor)
Type
Motor Type
Motor Output W
Fan(outdoor)
Type
Motor Type
Motor Output W Circuit Breaker A Power Supply Cable No.*mm
2
Power and Transmission Cable No.*mm2 + No.*mm
2
Piping Connections
Liquid Side mm(in)
Gas Side mm(in) Drain Hose (O.D/I.D) mm(in)
Dimension
Indoor(W*H*D)
mm
inch
Outdoor(W*H*D)
mm inch
Net Weight
Indoor kg(lbs)
Outdoor kg(lbs)
Gross Weight
Indoor kg(lbs)
Outdoor kg(lbs)
Operation Range
Cooling(Outdoor) ℃(℉)
Heating(Outdoor) ℃(℉) Max. Piping Length m(ft) Chargeless m(ft) Max. Elevation Difference m(ft) Tool Code(Chassis) Indoor + Outdoor
Fuctions
Temperature Control
Allergy Free Filter
Plasma Filter
Prefilter(washable/anti-fungus)
Auto Clean
CHAOS Wind(Auto Wind)
Steps, Fan/Cool/Heat
Airflow Direction Control(up& Down)
Airflow Direction Control(left & right)
Remote Controller Type
Setting Temperature
Cooling
Heating Auto Operation (Micom Control) Auto Changeover (Micom Control) Self Diagnosis Timer Sleep Operation Soft Dry Operation Restart Delay(minute) Deice Control(Defrost) Hot Start Jet Cool, Jet Heat Low Ambient Operation Special Function
LS090HEV LSN090HEV LSU090HEV
0.90~2.5~2.79
3070~8500~9500
0.90~2.7~3.15
3070~9000~10500
780/780
3.6/3.6
3.6/3.6
3.19/3.38
10.90/11.54
16.3
8.3
1, 208~230, 60
97.1%
8(283)
27(953)
0.83(1.76)
39/33/25/19
47
R410A, 750
20(0.22)
1P Rotary
GA092MMA
Brushless DC Motor
PVE(FVD68D)
310
-
Cross Flow Fan
BLDC
20
Propeller, Fan
AC
75 15
3*1.0
4*0.75
6.35(1/4)
9.52(3/8)
21.5,16.0(0.85,0.63) 756*265*184
29.8*10.4*7.2 717*483*230
28.2*19.0*9.1
7.2(15.9)
23.2(51.1)
8.6(19.0)
24.8(54.7)
18 ~ 48 (64.4 ~ 118.4)
-5 ~ 24 (23 ~ 75.2) 15(49.2)
-
7(23)
SW + UA3 Plus
O
-
­O O O
3/4/3
O
-
Wireless LCD(Better-Remocon)
18-30 16-30
­O O O O O
3 O O O
-
-
LS120HEV LSN120HEV LSU120HEV
0.9~3.5~3.8
3070~12000~13000
0.9~3.8~4.2
3070~12000~14300
1,170/980
5.2/4.4
5.2/4.4
3.00/3.59
10.26/12.24
16.3
8.5
1, 208~230, 60
98.3% 10(353) 27(953)
1.01(2.14)
39/33/25/19
47
R410A, 750
20(0.22)
1P Rotary
GA092MAB
Brushless DC Motor
PVE(FVD68D)
310
-
Cross Flow Fan
BLDC
20
Propeller, Fan
AC
75 15
3*1.0
4*0.75
6.35(1/4)
9.52(3/8)
21.5,16.0(0.85,0.63) 885*285*210
35.2*11.2*8.3 717*483*230
28.2*19.0*9.1
9(19.8)
22.0(48.5) 11(24.2)
23.6(52.1)
18 ~ 48 (64.4 ~ 118.4)
-5 ~ 24 (23 ~ 75.2) 15(49.2)
-
7(23)
SB + UA3 Plus
O
-
­O O O
3/4/3
O
-
Wireless LCD(Better-Remocon)
18-30 16-30
­O O O O O
3 O O O
-
-
Page 3
- 3 -
Copyright ©2011 LG Electronics. Inc. All right reserved. Only for training and service purposes
LGE Internal Use Only
2. Piping Diagrams
Indoor Unit Outdoor Unit
Heat Exchanger (Evaporator)
Heat Exchanger (Condenser)
Compressor
Accumulator
Gas Side
3-Way Valve
2-Way Valve
Liquid Side
Cooling
Heating
Reversing Valve
Th1
Th2
Th3
Th4
Th5
Th6
Capillary
Tube
LOC Description PCB Connector
Th1 Thermistor for indoor air temperature CH-TH1(Indoor)
Th2 Water level sensor (Option) CH-TH2(Indoor)
Th3 Thermistor for evaporating temperature CH-TH3(INDOOR)
Th4 Thermistor for discharge pipe temperature CN-TH2(OUTDOOR)
Th5 Thermistor for condensing temperature CN-TH1(OUTDOOR)
Th6 Thermistor for outdoor air temperature CN-TH1(OUTDOOR)
Page 4
- 4 -
Copyright ©2011 LG Electronics. Inc. All right reserved. Only for training and service purposes
LGE Internal Use Only
3. Wiring Diagrams
Indoor Unit
CN-COM2
CN-IN/N1
CN-L1
CN-U/D CN-DISP3
CN-DISP1
CH-TH1
CH-TH2
CH-TH3
Page 5
- 5 -
Copyright ©2011 LG Electronics. Inc. All right reserved. Only for training and service purposes
LGE Internal Use Only
Safety Precautions
Outdoor Unit
CN-UVW
BROWN
RED
BLUE
CN-COIL2
WCN-ACFAN(N)
CN-TH2
CN3
CN-TH1
CN-4WAY
CN-LGMV
CN-FAN
CN-FLASH
-WRITER
COM(RD) CN-COIL1
WCN-P(L)
CN2
WCN-P(N)
Page 6
- 6 -
Copyright ©2011 LG Electronics. Inc. All right reserved. Only for training and service purposes
LGE Internal Use Only
Indoor Unit ASNW093WSA7
4. Exploded View
LOC. Description PCB Connector
263230A Thermistor for indoor air temperature CN-TH1(Indoor)
263230B Thermistor for evaporating temperature CN-TH3(Indoor)
135316
237202
267110
146811
145200
354212
354210
352150
W50400
149304
342800
152302
13 1111
359011
131410
35211B
733010
149303
135516
135090
346810
268711B
135511
249951
147582
147581
135311
268711D
263230A
263230B
W6640
Page 7
- 7 -
Copyright ©2011 LG Electronics. Inc. All right reserved. Only for training and service purposes
LGE Internal Use Only
ASNW123BSA7
LOC. Description PCB Connector
263230A Thermistor for indoor air temperature CN-TH1(Indoor)
263230B Thermistor for evaporating temperature CN-TH3(Indoor)
135316
152302
135303
135511
131111
131410
267110
146811B
147582A
354212
354210
352150
W50400
145200
359011
147582B
149304
342800
147581
35211B
135311
268711D
249951
135516
149303
135080
346810
733010
135500A
263230B
268711C
W6640A
263230A
Page 8
Outdoor Unit
137213A
137213B
435511B
549610
546810
559010
552202
Tube Assembly, Reverse
Valve, Reverse
552116
437211
554031
135500C
552111
Tube Assembly, Capillary
430410
152503
550140
554160
W6640B W0CZZ
649950
268711F
263230B
263230A
552203A
552203B
148000
W6631
447910
261704
237202
435301
561410
435300
W4986A
W4986B
ASUW093WSA7/ASUW123BSA7
LOC. Description PCB Connector
263230A Thermistor for condensing temperature CN-TH1(Outdoor)
263230B Thermistor for discharge pipe temperature CN-TH2(Outdoor)
Copyright ©2011 LG Electronics. Inc. All right reserved. Only for training and service purposes
- 8-
LGE Internal Use Only
Page 9
P/NO : MFL67499915
February, 2015
Loading...