LG ASNW096MWR0 User Guide

www.lg.comP/NO : MFL67399744
TYPE : WALL MOUNTED
MODELS : ASNW096MWR0 - ASUW096MWR0 (AS-W096MWR0) ASNW126MWR0 - ASUW126MWR0 (AS-W126MWR0)
OWNER’S MANUAL
Please read this manual carefully before operating your set and retain it for future reference.
ENGLISH
TÜRE
2
TIPS FOR SAVING ENERGY
ENGLISH
TIPS FOR SAVING ENERGY
Here are some tips that will help you minimize the power consumption when you use the air conditioner. You can use your air conditioner more efficiently by referring to the instructions below:
• Do not cool excessively indoors. This may be harmful for your health and may consume more electricity.
• Block sunlight with blinds or curtains while you are operating the air conditioner.
• Keep doors or windows closed tightly while you are operating the air conditioner.
• Adjust the direction of the air flow vertically or horizontally to circulate indoor air.
• Speed up the fan to cool or warm indoor air quickly, in a short period of time.
• Open windows regularly for ventilation as the indoor air quality may deteriorate if the air con­ditioner is used for many hours.
• Clean the air filter once every 2 weeks. Dust and impurities collected in the air filter may block the air flow or weaken the cooling / dehumidifying functions.
For your records
Staple your receipt to this page in case you need it to prove the date of purchase or for warranty purposes. Write the model number and the serial number here:
Model number :
Serial number :
You can find them on a label on the side of each unit.
Dealer’s name :
Date of purchase :
IMPORTANT SAFETY INSTRUCTIONS
3
ENGLISH
IMPORTANT SAFETY INSTRUCTIONS
READ ALL INSTRUCTIONS BEFORE USING THE APPLIANCE.
Always comply with the following precautions to avoid dangerous situations and ensure peak performance of your product
WARNING
It can result in serious injury or death when the directions are ignored
CAUTION
It can result in minor injury or product damage when the directions are ignored
WARNING
• Installation or repairs made by unqualified persons can result in hazards to you and others.
• Appliance shall be installed in accordance with national wiring regulations.
• If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified persons in order to avoid a hazard.
• The information contained in the manual is intended for use by a qualified service technician familiar with safety procedures and equipped with the proper tools and test instruments.
• Failure to carefully read and follow all instructions in this manual can result in equipment mal­function, property damage, personal injury and/or death.
• When the power cord is to be replaced, replacement work shall be performed by authorized personnel only using only genuine replacement parts.
Installation
• Use a standard circuit breaker and fuse conforming with the rating of the air conditioner. Fail­ure to do so may result in electric shock or product failure.
• Contact an authorized service center when you install or relocate the air conditioner. Failure to do so may result in serious injury or product failure.
• Always use a power plug and socket with a ground terminal.Failure to do so may result in electric shock or product failure
• Install the panel and the cover of the control box safely. Failure to do so may result in explo­sion or fire.
• Install a dedicated electric outlet and circuit breaker before you use the air conditioner. Failure to do so may result in electric shock or product failure.
• Do not modify or extend the power cable. If the power cable or cord has scratches or skin peeled off or deteriorated then it must be replaced. It may result in fire or electric shock.
• Be cautious when you unpack or install the air conditioner. Failure to do so may result in seri­ous injury or product failure.
• Do not install the air conditioner on an unstable surface or where there may be a danger of it falling. It may result in death, serious injury, or product failure.
• Use inflammable gas (nitrogen) to inspect leak and to purge air, using compressed air or flam­mable gas may cause fire or explosion.
• Select installation locations that can properly support the weight of the indoor. Failure to do so may cause property damage, product failure, and personal injury.
• Improper wiring or installation may cause fire or electric shock.
• Exposure of unit to water or other moisture before installation could result in electrical shock. Do not store in it a wet basement or expose to rain or water.
• When installing the unit, use the installation kit provided with the product. Otherwise the unit
!
!
!
4
IMPORTANT SAFETY INSTRUCTIONS
ENGLISH
may fall and cause severe injury.
• Do not install the outdoor unit in a place which can be a nest for small animals. Small animals could enter and contact internal electrical parts, causing a failure or fire.
Operation
• Do not let the air conditioner run for a long time when the humidity is very high or when a door or window has
been left open. Failure to do so may result in product failure.
• Make sure that the power cord is not pulled or damaged while the air conditioner is operating. Failure to do so
may result in fire, electric shock, or product failure.
• Do not place any objects on the power cord. It may result in electric shock or product failure.
• Do not turn on or off the air conditioner by plugging in or unplugging the power plug. It may result in fire or elec-
tric shock.
• Do not touch, operate or repair the air conditioner with wet hands. It may result in electric shock or product fail-
ure.
• Do not place a heater or other heating appliances near the power cable. It may result in fire, electric shock, or
product failure.
• Do not allow water to run into the air conditioner. It may result in explosion or fire.
• Do not leave flammable substances such as gasoline, benzene and thinner near the air conditioner. It may re-
sult in explosion or fire.
• Do not use the air conditioner for an extended period of time in a small place without ventilation. Ventilate the
place regularly. Failure to do so may result in explosion or fire.
• When there is a gas leak, ventilate sufficiently before using the air conditioner again. Failure to do so may result
in explosion or fire.
• Unplug the power plug if there is a noise, smell or smoke coming from the air conditioner. Failure to do so may
result in explosion or fire.
• Stop operating and close the window in strom or hurricane.If possible remove the product from the window
before hurricane arrives
• Contact an authorized service center when the air conditioner is submerged into water due to flooding. Failure
to do so may result in explosion or fire.
• Be cautious water could not enter the product
• Make sure to ventilate sufficiently when this air conditioner and a heating appliance such as a heater are used
simultaneously. Failure to do so may result in fire, serious injury, or product failure.
• Turn the main power off and unplug the power plug when you clean or repair the air conditioner. Failure to do
so may result in death, serious injury, or product failure.
• Unplug the power plug when the air conditioner is not used for an extended period of time. Failure to do so
may result in product failure.
• Do not place any objects on the air conditioner. It may result in product failure.
• For inner cleaning, contact an Authorized Service Center or a dealer.
Do not use harsh detergent that causes corrosion or damage on the unit. Harsh detergent may also cause failure of product, fire, or electronic shock.
• This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental
capabilities, or lack of experience and knowledge unless they have been given supervision or instruction con­cerning use of the appliance by a person responsible for their safety.
• Children should be supervised to ensure that they do not play with the appliance.
• For electrical work, contact the dealer, seller, a qualified electrician, or an Authorized Service Center. There is
risk of fire or electric shock.
• Do not hang laundry or other objects from the unit. The unit could fall and cause property damage, product fail-
ure, and personal injury.
• Safely dispose of the packing materials. Like screws, nails, batteries, broken things etc after installation or svc
and then tear away and throw away the plastic packaging bags. Children may play with them and cause injury.
IMPORTANT SAFETY INSTRUCTIONS
5
ENGLISH
CAUTION
Installation
• Make sure to check if there is a refrigerant leak after you install or repair the air conditioner. Failure to do so may result in product failure.
• Install the drain hose properly for smooth drainage of condensed water. Failure to do so may result in product failure.
• Keep level even when installing the product.
• Install the air conditioner where the noise from the outdoor unit or the exhaust gas will not inconvenience the neighbors. Failure to do so may result in conflict between neighbors.
• When transporting the equipment, there should be at least 2 or more people, or a forklift. It may result in seri­ous injury.
• Do not install the air conditioner where it will be exposed to sea wind (salt spray) directly. It may result in prod­uct failure.
Operation
• Do not expose people, animals or plants to the cold or hot wind from the air conditioner. It may result in serious injury.
• Do not use the product for special purposes, such as preserving foods, works of art, etc. It is a consumer air conditioner, not a precision refrigeration system. It may result in death, fire or electric shock.
• Do not block the inlet or outlet of air flow. It may result in explosion or product failure.
• Do not use strong cleaning agents or solvents when you clean the air conditioner, or spray water. Use a smooth cloth. It may result in serious injury or product failure.
• Never touch the metal parts of the air conditioner when you remove the air filter. It may result in serious injury or product failure.
• Always insert the filter securely after cleaning. Clean the filter every two weeks or more often if necessary.
• Do not insert hands or other objects through the air inlet or outlet while the air conditioner is operating. It may result in electric shock.
• Do not drink the water drained from the air conditioner. It may result in serious health complications.
• Use a sturdy stool or ladder when you clean, maintain or repair the air conditioner at a height. Failure to do so may result in serious injury or product failure.
• Do not mix the batteries for the remote control with other types of batteries or mix new batteries with used batteries. Failure to do so may result in product failure.
• Do not recharge or disassemble the batteries. Failure to do so may result in explosion, fire or serious injury.
• Stop using the remote control if there is a battery fluid leak. If your cloth or skin is exposed to the battery fluid from a leak, wash it off with clean water. Failure to do so may result in serious injury.
• If you swallow the battery fluid from a leak, wash out the inside of your mouth thoroughly and then consult a doctor. Failure to do so may result in serious health complications.
• Do not step on the indoor/outdoor unit and do not put anything on it. It may cause an injury through dropping of the unit or falling down.
• Do not tilt the unit when removing or uninstalling it. The condensed water inside can spill.
• Be careful that liquids do not spill onto the remote controller. Otherwise, it may cause failure of remote con­troller.
• Do not expose the remote controller to direct sunlight or heat. Air conditioner may not function properly.
!
6
TABLE OF CONTENTS
ENGLISH
TABLE OF CONTENTS
2
TIPS FOR SAVING ENERGY
3 IMPORTANT SAFETY
INSTRUCTIONS
7 BEFORE USE
7 Components
8 Using the remote control
10 BASIC FUNCTIONS
10 Cooling your room
10 Heating your room
10 Removing humidity
11 Airing your room
11 Adjusting the fan speed
11 Adjusting the air flow direction
11 Setting the timer
12 Setting sleep mode
13 ADVANCED FUNCTIONS
13 Changing room temperature quickly
13 Indoor air purification
13 Display the current energy usage
14 Plasmaster Purification operation
14 Auto operation
14 Auto Changeover operation
15 Silent mode
15 Active Energy Control mode
15 Display screen brightness
16 Operating the air conditioner without the
remote control
16 Restarting the air conditioner
automatically
17 MAINTENANCE
19 Cleaning the air filter
19 Cleaning the 3M filter
20 TROUBLESHOOTING
20 Self-diagnosis function
20 Before requesting service
BEFORE USE
7
ENGLISH
BEFORE USE
Components
Outdoor unit
NOTE
!
The number of operation lamps and their locations may vary, depending on the model of the air conditioner.
Indoor unit
* The feature can be changed according to type of model.
* The feature can be changed according to type of model.
Operation ranges
The table below indicates the temperature ranges the air conditioner can be operated within.
Mode Indoor temperature outdoor temperature Cooling 18°C~32°C -10°C~48°C Heating 16°C~30°C -10°C~24°C
3M filter
Front grille
Air filter
Air outlet
Air inlet
On/Off button
Signal receiver
Operation lamp
Ionizer
Air deflector (Vertical louver & Horizontal vane)
Air inlet vents
Air outlet vents
Coolant piping
Drain hose
Connection wire
Base plate
Loading...
+ 16 hidden pages