LG ARNU28GM2A4 installation manual

AIR CONDITIONER
ENGLISH
FRANÇAIS
Please read this installation manual completely before installing the product. Installation work must be performed in accordance with the national wiring standards by authorized personnel only. Please retain this installation manual for future reference after reading it thoroughly.
CEILING CONCEALED DUCT
Original instruction
www.lg.com
P/NO : MFL68821906
Copyright © 2017 LG Electronics Inc. All Rights Reserved.
TABLE OF CONTENTS
Installation Requirements
Features...................................3
Safety Precautions.................4
Installation
Selection the best location....9
Ceiling opening dimension
and hanging bolt location....10
Indoor Unit Installation.........11
Wiring Connection ...............11
Checking the Drainage .......12
Indoor Unit Drain Piping......13
Required Parts Required Tools
o Level gauge o Screw driver
o Connecting cable
o Pipes: Gas side
Liquid side (Refer to Product Data)
o Insulation materials o Additional drain pipe
o Electric drill o Hole core drill
o Flaring tool set o Specified torque wrenches
(different depending on model No.)
o Spanner.......Half union
o A glass of water
o Hexagonal wrench o Gas-leak detector o Vacuum pump o Gauge manifold
Dip Switch Setting ...............15
Group Control Setting .........16
Model Designation ..............21
Airborne Noise Emission ....21
Limiting concentration .........21
How to Set E.S.P?................22
2 Indoor Unit
o Owner's manual o Thermometer
Remote Controller
Air inlet vents
Air outlet vents
(Accessory)
Features
Installation Tool
Name Drain hose Clamp metal
Quantity
1 EA 2 EA 8 EA 4 EA 1 SET
Washer for
hanging bracket
Clamp
(Tie Wrap)
Insulation for
fitting
Feature
(Other)
• Owner's manual Installation manual
ENGLISH
Shape
for gas pipe
for liquid pipe
Installation Manual 3
Safety Precautions
WARNING
CAUTION
WARNING
Safety Precautions
To prevent injury to the user or other people and property damage, the following instructions must be followed. n Incorrect operation due to ignoring instruction will cause harm or damage. The seriousness is classi-
fied by the following indications.
This symbol indicates the possibility of death or serious injury.
This symbol indicates the possibility of injury or damage to properties only.
n Meanings of symbols used in this manual are as shown below.
Be sure not to do.
Be sure to follow the instruction.
n Installation
Do not use a defective or underrated circuit breaker. Use this appli­ance on a dedicated circuit.
• There is risk of fire or electric shock.
Install the panel and the cover of control box securely.
• There is risk of fire or electric shock.
Do not modify or ex­tend the power cable.
• There is risk of fire or electric shock.
4 Indoor Unit
For electrical work, contact the dealer, seller, a qualified elec­trician, or an Author­ized Service Center.
• Do not disassemble or
• There is risk of fire or repair the product. There is risk of fire or electric shock.
Always install a dedi­cated circuit and breaker.
• Improper wiring or in-
• There is risk of fire or stallation may cause fire or electric shock.
Do not install, remove, or re-install the unit by yourself (customer).
• There is risk of fire,
• electric shock, explo­sion, or injury.
Always ground the product.
electric shock.
Use the correctly rated breaker or fuse.
electric shock.
Be cautious when un­packing and installing the product.
Sharp edges could cause injury. Be especially careful of the case edges and the fins on the condenser and evaporator.
For installation, always con­tact the dealer or an Author­ized Service Center.
• There is risk of fire, electric shock, explo­sion, or injury.
Do not install the prod­uct on a defective in­stallation stand.
• It may cause injury, ac­cident, or damage to the product.
Safety Precautions
Be sure the installation area does not deterio­rate with age.
If the base collapses, the air conditioner could fall with it, causing property damage, product failure, and personal injury.
ENGLISH
Do not turn on the breaker or power under condition that front panel, cabinet, top cover, control box cover are removed or opened.
Use a vacuum pump or Inert (nitrogen) gas when doing leakage test or air purge. Do not compress air or Oxygen and Do not use Flammable gases. Oth­erwise, it may cause fire or explosion.
• Otherwise, it may cause fire, electric shock, explosion or death.
• There is the risk of death, injury, fire or explosion.
n Operation
Do not let the air condi­tioner run for a long time when the humidity is very high and a door or a window is left open.
• Moisture may condense and wet or damage fur-
Take care to ensure that power cable could not be pulled out or damaged during oper­ation.
• There is risk of fire or electric shock.
niture.
Do not plug or unplug the power supply plug during operation.
• There is risk of fire or electric shock.
Do not touch(operate) the product with wet hands.
• There is risk of fire or electrical shock.
Do not place anything on the power cable.
• There is risk of fire or electric shock.
Do not place a heater or other appliances near the power cable.
• There is risk of fire and electric shock.
Do not allow water to run into electric parts.
It may cause There is
• There is risk of fire or risk of fire, failure of the product, or electric shock.
Do not store or use flammable gas or com­bustibles near the
Do not use the product in a tightly closed space for a long time.
product.
• Oxygen deficiency could
failure of product.
occur.
Installation Manual 5
Safety Precautions
When flammable gas leaks, turn off the gas and open a window for ventilation before turn the product on.
If strange sounds, or small or smoke comes from product. Turn the breaker off or discon­nect the power supply cable.
• Do not use the tele-
• There is risk of electric phone or turn switches on or off. There is risk of explosion or fire.
Do not open the inlet grill of the product dur­ing operation. (Do not touch the elec­trostatic filter, if the
When the product is soaked (flooded or submerged), contact an Authorized Service Center.
unit is so equipped.)
• There is risk of physical
• There is risk of fire or injury, electric shock, or product failure.
shock or fire.
electric shock.
Stop operation and close the window in storm or hurricane. If possible, remove the product from the win­dow before the hurri­cane arrives.
• There is risk of property damage, failure of prod­uct, or electric shock.
Be cautious that water could not enter the product.
• There is risk of fire, electric shock, or prod­uct damage.
Ventilate the product from time to time when operating it together with a stove, etc.
Turn the main power off when cleaning or maintaining the prod­uct.
When the product is not be used for a long time, disconnect the power supply plug or turn off the breaker.
• There is risk of fire or electric shock.
• There is risk of electric shock.
• There is risk of product damage or failure, or unintended operation.
Take care to ensure that nobody could step on or fall onto the outdoor unit.
• This could result in personal injury and product damage.
6 Indoor Unit
CAUTION
n Installation
Safety Precautions
ENGLISH
Always check for gas (refrigerant) leakage after installation or re-
Install the drain hose to ensure that water is drained away properly.
pair of product.
• Low refrigerant levels
• A bad connection may may cause failure of product.
Do not install the prod­uct where the noise or hot air from the outdoor
Use two or more peo­ple to lift and transport
the product. unit could damage the neighborhoods.
• It may cause a problem
• Avoid personal injury.
for your neighbors.
cause water leakage.
Keep level even when installing the product.
• To avoid vibration or water leakage.
Do not install the prod­uct where it will be ex­posed to sea wind (salt spray) directly.
• It may cause corrosion on the product. Corro­sion, particularly on the condenser and evapora­tor fins, could cause product malfunction or inefficient operation.
n Operation
Do not expose the skin directly to cool air for long periods of time. (Don't sit in the draft.)
• This could harm to your health.
Do not use the product for special purposes,
Do not block the inlet
or outlet of air flow. such as preserving foods, works of art, etc. It is a consumer air con­ditioner, not a precision refrigeration system.
• There is risk of damage or loss of property.
• It may cause product failure.
Installation Manual 7
Safety Precautions
Use a soft cloth to clean. Do not use harsh detergents, sol­vents, etc.
• There is risk of fire,
• There is risk of personal electric shock, or dam­age to the plastic parts of the product.
Always insert the filter securely. Clean the filter every two weeks or more often if necessary.
A dirty filter reduces the
• There are sharp and efficiency of the air condi­tioner and could cause product malfunction or damage.
Use a firm stool or lad­der when cleaning or maintaining the prod­uct.
Do not touch the metal parts of the product when removing the air filter.
Do not step on or put anyting on the product. (outdoor units)
They are very sharp!
• There is risk of personal
injury.
injury and failure of product.
Do not insert hands or other objects through the air inlet or outlet while the
Do not drink the water drained from the prod­uct.
product is operated.
• It is not sanitary and moving parts that could cause personal injury.
Replace the all batteries in the remote control with new ones of the same type. Do not mix old and
could cause serious health issues.
Do not recharge or dis­assemble the batteries. Do not dispose of bat-
teries in a fire. new batteries or different types of batteries.
• Be careful and avoid personal injury.
If the liquid from the batteries gets onto your skin or clothes, wash it well with clean water. Do not use the re­mote if the batteries have leaked.
• The chemicals in batteries could cause burns or other health hazards.
8 Indoor Unit
• There is risk of fire or explosion.
If you eat the liquid from the batter­ies, brush your teeth and see doc­tor. Do not use the remote if the batteries have leaked.
• The chemicals in batteries could cause burns or other health hazards.
• They may burn or ex­plode.
+ 16 hidden pages