LG ANNQ60GKA4 INSTALLATION MANUAL

INSTALLATION MANUAL
SINGLE DUCTED SPLIT
AIR CONDITIONER
Please read this installation manual completely before installing the product. Installation work must be performed in accordance with the national wiring standards by authorized personnel only. Please retain this installation manual for future reference after reading it thoroughly.
MFL68061102
Rev.02 _ 052020
www.lg.com
Copyright © 2016 - 2020 LG Electronics Inc. All Rights Reserved.
ENGLISH ESPAÑOL
TIPS FOR SAVING ENERGY
2
ENGLISH
TIPS FOR SAVING ENERGY
Here are some tips that will help you minimize the power consumption when you use the air conditioner. You can use your air conditioner more efficiently by referring to the instructions below:
• Do not cool excessively indoors. This may be harmful for your health and may consume more electricity.
• Block sunlight with blinds or curtains while you are operating the air conditioner.
• Keep doors or windows closed tightly while you are operating the air conditioner.
• Adjust the direction of the air flow vertically to circulate indoor air.
• Speed up the fan to cool or warm indoor air quickly, in a short period of time.
• Open windows regularly for ventilation as the indoor air quality may deteriorate if the air conditioner is used for many hours.
• Clean the air filter once every 2 weeks. Dust and impurities collected in the air filter may block the air flow or weaken the cooling / dehumidifying functions.
For your records
Staple your receipt to this page in case you need it to prove the date of purchase or for warranty purposes. Write the model number and the serial number here:
Model number :
Serial number :
You can find them on a label on the side of each unit.
Dealer’s name :
Date of purchase :
IMPORTANT SAFETY INSTRUCTIONS
IMPORTANT SAFETY INSTRUCTIONS
READ ALL INSTRUCTIONS BEFORE USING THE APPLIANCE.
Always comply with the following precautions to avoid dangerous situations and ensure peak performance of your product
WARNING
!
It can result in serious injury or death when the directions are ignored
CAUTION
!
It can result in minor injury or product damage when the directions are ignored
WARNING
!
• Installation or repairs made by unqualified persons can result in hazards to you and others.
• The information contained in the manual is intended for use by a qualified service technician familiar with safety procedures and equipped with the proper tools and test instruments.
• Failure to carefully read and follow all instructions in this manual can result in equipment malfunction, property damage, personal injury and/or death.
Installation
• Do not use a defective or underrated circuit breaker. Use this appliance on a dedicated circuit.
- There is risk of fire or electric shock.
• For electrical work, contact the dealer, seller, a qualified electrician, or an Authorized Service Center. Do not disassemble or repair the product.
- There is risk of fire or electric shock.
• Always ground the product.
- There is risk of fire or electric shock.
• Install the panel and the cover of control box securely.
- There is risk of fire or electric shock.
• Always install a dedicated circuit and breaker.
- Improper wiring or installation may cause fire or electric shock.
• Use the correctly rated breaker or fuse.
- There is risk of fire or electric shock.
• Do not modify or extend the power cable.
- There is risk of fire or electric shock.
• Do not let the air conditioner run for a long time when the humidity is very high and a door or a window is left open.
- Moisture may condense and wet or damage furniture.
• Be cautious when unpacking and installing the product. Sharp edges could cause injury.
- Be especially careful of the case edges and the fins on the condenser and evaporator.
• For installation, always contact the dealer or an Authorized Service Center.
- There is risk of fire, electric shock, explosion, or injury.
• Do not install the product on a defective installation stand.
- It may cause injury, accident, or damage to the product.
• Be sure the installation area does not deteriorate with age.
- If the base collapses, the air conditioner could fall with it, causing property damage, product failure,
and personal injury.
3
ENGLISH
4
ENGLISH
• Use a vacuum pump or Inert (nitrogen) gas when doing leakage test or air purge. Do not compress
Operation
• Do not store or use flammable gas or combustibles near the product.
!
Installation
• Always check for gas (refrigerant) leakage after installation or repair of product.
• Install the drain hose to ensure that water is drained away properly.
• Keep level even when installing the product.
• Do not install the product where the noise or hot air from the outdoor unit could damage the
• Use two or more people to lift and transport the product.
• Do not install the product where it will be exposed to sea wind (salt spray) directly. It may cause
• If you eat the liquid from the batteries, brush your teeth and see doctor. Do not use the remote if
• Safely dispose of the packing materials. Packing materials, such as nails and other metal or wooden
IMPORTANT SAFETY INSTRUCTIONS
air or Oxygen and do not use Flammable gases. Otherwise, it may cause fire or explosion.
- There is the risk of death, injury, fire or explosion.
- There is risk of fire or failure of product.
CAUTION
- Low refrigerant levels may cause failure of product.
- A bad connection may cause water leakage.
- To avoid vibration or water leakage.
neighborhoods.
- It may cause a problem for your neighbors.
- Avoid personal injury.
corrosion on the product. Corrosion, particularly on the condenser and evaporator fins, could cause product malfunction or inefficient operation.
the batteries have leaked. The chemicals in batteries could cause burns or other health hazards.
parts, may cause stabs or other injuries. Tear apart and throw away plastic packaging bags so that children may not play with them. If children play with a plastic bag which was not torn apart, they face the risk of suffocation.
TABLE OF CONTENTS
2 TIPS FOR SAVING ENERGY
3 IMPORTANT SAFETY INSTRUCTIONS
6 FEATURES
7 Duct Connection Dimensions
8 INSTALLATION
8 Selection of the best location
9 Upflow Installation
10 Duct work
11 Insulation
12 Condensate Drain
14 Wiring Connection
16 INSTALLATION INSTRUCTION
19 Remote controller installation
20 Group control
21 Installer Setting -E.S.P.
TABLE OF CONTENTS
5
ENGLISH
22 PRODUCT DATA
22 External Static Pressure & Air Flow
FEATURES
6
ENGLISH
FEATURES
Wiring knockouts for conduit
Wiring knockouts for conduit
Refrigerant connections
Filter access
Drain connections for upflow application
Duct Connection Dimensions
G
H
FEATURES
7
ENGLISH
Refrigerant connections
Air filter cover
I
<Top>
D
<Front>
J
Drain connections for upflow application
F
J
A
C
<Side-right>
E
<Bottom>
(Unit: inch(mm))
Dimensions
A B C
Wiring
Knock out
I J
Refrigerant
Connections
Pipe size
D E F G H
Height Width Depth Power Communication Liquid Gas
55-1/8 (1 401)25(635)
21-3/8
(540)
1-9/16
(40)
24-1/2
(623)
20
(530)
24
(610)
12-1/8
(308)
1-11/16
(43)
7/8
(22)
3/8
(9.52)
3/4
(19.05)
Loading...