LG
LG
Multi Type Air Conditioner
INSTALLATION MANUAL
IMPORTANT
•Please read this instruction sheet completely before installing the product.
•When the power cord is damaged, replacement work shall be performed by authorized personnel only.
•Installation work must be performed in accordance with the national wiring standards by authorized personnel only.
<![endif]>ESPAÑOL ENGLISH
Multi Type Air Conditioner Installation Manual
TABLE OF CONTENTS
Installation Requirements |
|
Installation Parts Provided ......................................... |
3 |
Safety Precautions.................................................. |
4~5 |
Installation of indoor, outdoor unit ..................... |
6~11 |
Flaring work and connection of piping............. |
12~21 |
Connecting the Cable between Indoor Unit and |
|
Outdoor Unit ........................................................ |
22~24 |
Checking the Drainage, Forming the Pipings |
|
and Long pipe Setting ........................................ |
25~27 |
Air Purging and Evacuation ..................................... |
28 |
Panel Front Assembly .............................................. |
30 |
Installation PI485....................................................... |
31 |
Test running............................................................... |
33 |
Combination indoor units ........................................ |
34 |
Max Combination Capacity ...................................... |
35 |
Installation guide at the seaside.............................. |
36 |
Required Tools
Level gauge
Screw driver
Electric drill
Hole core drill (ø70mm)
Horizontal meter
Flaring tool set
Specified torque wrenches 1.8kg.m, 4.2kg.m, 5.5kg.m, 6.6kg.m (different depending on model No.)
Spanner .................Half union
A glass of water
Screw driver
Hexagonal wrench(4mm)
Gas-leak detector
Vacuum pump
Gauge manifold
Owner's manual
Thermometer
Holder Remote Control
2 Multi Air Conditioner
Installation Parts Provided
Installation Parts Provided
Standard Type
Installation plate
Type "B" screws
Type "A" screw (6 EA) |
Type "A" screw (8 EA) |
Type "A" screw and plastic anchors |
|
|
|
|
|
|
Holder Remote Control
<![endif]>ENGLISH
more than |
|
|
60cm |
|
5. Copper pipe (Liquid side) |
more than |
6. Copper pipe (Gas side) |
|
|
||
more than |
30cm |
|
30cm |
|
|
more than |
70cm |
7. Connecting cable
more than 60cm
|
more than |
|
|
60cm |
Air Intake |
|
|
|
|
|
(side, rear) |
|
|
more than |
|
|
30cm |
more than |
|
|
30cm |
|
Control cover |
|
|
Connecting wire |
|
|
Connection pipe |
|
|
Drain hose |
more than |
|
more than |
|
60cm |
|
70cm |
|
|
|
|
|
|
Air Outlet |
Installation Manual 3
Safety Precautions
Safety Precautions
To prevent injury to the user or other people and property damage, the following instructions must be followed.
■Incorrect operation due to ignoring instruction will cause harm or damage. The seriousness is classified by the following indications.
WARNING |
This symbol indicates the possibility of death or serious injury. |
CAUTION |
This symbol indicates the possibility of injury or damage. |
■ Meanings of symbols used in this manual are as shown below.
Be sure not to do.
Be sure to follow the instruction.
WARNING
Do not disassemble or repair the product.
Do not handle the flamable gas or explosive materials near the product.
Do not install the product on a defected installation stand.
For installation, always contact the dealer or service center.
Always earth the product.
•It will cause fire or electric shock.
Do not install where flamable gas could leak.
•Otherwise, it may cause esplosion or fire.
Be cautious when unpacking and installing the product.
•Sharp edges could cause injury.
For electric work, contact the dealer or service center.
•Otherwise, it may cause fire, electric shock, explosion or injury."
•Otherwise, It will cause fire or electric shock.
Always intstall a circuit breaker and main breaker.
•No installation may cause fire and electric shock.
|
Safety Precautions |
|
|
Do not touch(operate) product with wet |
If strange sound, smell or smoke come from |
hands. |
product, turn the breaker off. |
• Otherwise, it may cause fire or electric shock. |
• Otherwise, it may cause electric shock or fire. |
|
part. |
|
may cause fire or electric shock. |
|
the suction inlet of the product |
|
. |
|
may cause electric shock or |
|
put anyting on the product. |
|
may cause personal injury and |
|
. |
Fix the outdoor unit on the floor.
•Otherwise, it can be blown away by the strong wind. It will cause injury or accident.
CAUTION
Install the drain hose to ensure that drain can be securely done.
• Otherwise, it may cause water leakage.
Do not install the product where the noise or hot wind from the outdoor unit could give any casualty to the neighborhood
• Otherwise, it may cause dispute with the neighborhoods.
<![endif]>ENGLISH
Installation Manual 5
Installation of Indoor, Outdoor Unit
Installation of Indoor, Outdoor Unit
Read completely, then follow step by step.
Select
the
best
location
Indoor unit
1.Do not have any heat or steam near the unit.
2.Select a place where there are no obstacles in front of the unit.
3.Make sure that condensation drainage can be conveniently routed away.
4.Do not install near a doorway.
5.Ensure the spaces indicated by arrows from the wall, ceiling, fence or other obstacles.
6.Use a stud finder to locate studs to prevent unnecessary damage to the wall.
CAUTION: Install the indoor unit on the wall where the height from the floors more than 2.3 meters. (ART COOL Type Only 1.5m)
Outdoor unit
1.If an awning is built over the unit to prevent direct sunlight or rain exposure, make sure that heat radiation from the condenser is not restricted.
2.Ensure that the spaces indicated by arrows around front, back and side of the unit.
3.Do not place animals and plants in the path of the warm air.
4.Take the air conditioner weight into account and select a place where noise and vibration are minimum.
5.Select a place so that the warm air and noise from the air conditioner do not disturb neighbors.
Rooftop Installations:
If the outdoor unit is installed on a roof structure, be sure to level the unit. Ensure the roof structure and anchoring method are adequate for the unit location. Consult local codes regarding rooftop mounting.
More than |
|
10cm |
20cm |
|
|
|
More than |
More |
10cm |
|
|
More than |
|
10cm |
20cm |
|
|
|
More than |
|
10cm |
More |
|
More |
More than 20cm |
than 50cm |
|
|
More |
More than 1. |
than 50cm |
|
|
more than 60cm |
more than |
more than |
30cm |
30cm |
|
more than |
more than |
60cm |
70cm |
|
|
more than 60cm |
|
more than |
|
30cm |
more than |
|
30cm |
|
more than |
|
70cm |
|
|
more than |
|
60cm |
6 Multi Air Conditioner
Installation of Indoor, Outdoor Unit
Fixing
Installation
Plate
The wall you select should be strong and solid enough to prevent vibration
1.Mount the installation plate on the wall with type "A" screws. If mounting the unit on a concrete wall, use anchor bolts.
•Mount the installation plate horizontally by aligning the centerline using a level.
Chassis
Hook
<Type 1> |
Type “A” |
2.Measure the wall and mark the centerline. It is also important to use caution concerning the location of the installation plate-routing of the wiring to power outlets is through the walls typically. Drilling the hole through the wall for piping connections must be done safely.
Installation Plate
Chassis
Hook
<Type 2> |
Type “A” |
|
|
|
|
|
|
||
D |
|
Installation plate |
B |
|
|
|
|
||
Ø70mm |
C |
<Type 1> |
A |
Ø70mm |
|
Left rear piping |
Right rear piping |
|
|
|
Installation plate |
|
|
Ø70mm |
133mm |
<Type 2> |
100mm |
Ø70mm |
|
|
|
||
|
Left rear piping |
Right rear piping |
|
Indoor Type |
Capacity |
|
Distance (mm) |
|
Type |
||
(kBtu/h) |
A |
B |
C |
D |
|||
|
|
||||||
|
|
|
|
|
|
|
|
Wall mounted |
7,9,12 |
55 |
105 |
65 |
105 |
1 |
|
|
|
|
|
|
|
||
18,24 |
100 |
122 |
240 |
122 |
2 |
||
|
|||||||
|
|
|
|
|
|
|
|
ART COOL Mirror |
7,9,12 |
70 |
110 |
90 |
110 |
1 |
|
|
|
|
|
|
|
||
18,24 |
100 |
122 |
240 |
122 |
2 |
||
|
|||||||
|
|
|
|
|
|
|
<![endif]>ENGLISH
Installation Manual 7
Installation of Indoor, Outdoor Unit
Piping
length
and
elevation
Multi Piping Type |
|
|
|
(Unit: m) |
|
|
|
|
|
|
|
Capacity(kBtu/h) |
|
Total Length |
Max Length(A/B) |
Max Elevation |
In - In Elevation |
|
(h1) |
(h2) |
|||
|
|
|
|
||
|
|
|
|
|
|
21 |
|
50 |
25 |
15 |
7.5 |
24/27 |
|
70 |
25 |
15 |
7.5 |
30 |
|
75 |
25 |
15 |
7.5 |
40 |
|
85 |
25 |
15 |
7.5 |
Distributor Type |
|
|
|
|
|
(Unit: m) |
|
Phase |
Capacity |
Total Length |
Max Main Pipe |
Total Branch |
Max Branch |
Max Elevation |
In - In Elevation |
(kBtu/h) |
Length (A/B) |
Pipe Length |
Pipe Length |
(h1) |
(h2) |
||
|
|
|
|
|
|
|
|
|
40 |
100 |
50 |
50 |
15 |
30 |
15 |
|
|
|
|
|
|
|
|
1Ø |
48 |
135 |
55 |
80 |
15 |
30 |
15 |
|
|
|
|
|
|
|
|
|
56 |
145 |
55 |
90 |
15 |
30 |
15 |
|
|
|
|
|
|
|
|
|
42 |
125 |
55 |
70 |
15 |
30 |
15 |
|
|
|
|
|
|
|
|
3Ø |
48 |
135 |
55 |
80 |
15 |
30 |
15 |
|
|
|
|
|
|
|
|
|
54 |
145 |
55 |
90 |
15 |
30 |
15 |
|
|
|
|
|
|
|
|
A |
A Distributor |
Branch Pipe |
|
||
|
h2 |
|
|
Distributor |
|
|
|
h2 |
h1 |
h1 |
|
|
|
|
|
|
Main Pipe |
B |
B |
|
Multi Piping Type Distributor Type
CAUTION: Capacity is based on standard length and maximum allowance length is on the basis of reliability. If outdoor unit is at higher elevation than the indoor units, after 24m of vertical height, 1 oil trap is required.
8 Multi Air Conditioner
Installation of Indoor, Outdoor Unit
Refrigerant
charge
The calculation of the additional charge should be taken in account for the length of extra pipe.
Multiple Piping Models
Model |
Standard |
Max piping for |
Max total Piping |
Additional |
|
length(m) |
one room(m) |
Length(m) |
Charge(g/m) |
||
|
|||||
|
|
|
|
|
|
A3UW216FA3 |
7.5 |
25 |
50 |
20 |
|
A4UW246FA3 |
7.5 |
25 |
70 |
20 |
|
A4UW276FA3 |
7.5 |
25 |
70 |
20 |
|
A5UW306FA3 |
7.5 |
25 |
75 |
20 |
|
A5UW406FA3 |
7.5 |
25 |
85 |
20 |
Distributor type Models
|
|
Main Piping length |
Branch piping length |
||
Phase |
Model |
Standard |
Additional |
Standard |
Additional |
|
|
length(m) |
refrigerant(g/m) |
length(m) |
refrigerant(g/m) |
|
|
|
|
|
|
|
A7UW406FA3 |
5 |
50 |
35 |
20 |
1Ø |
A8UW486FA3 |
5 |
50 |
40 |
20 |
|
A9UW566FA3 |
5 |
50 |
45 |
20 |
|
A7UW428FA3 |
5 |
50 |
35 |
20 |
3Ø |
A8UW488FA3 |
5 |
50 |
40 |
20 |
|
A9UW548FA3 |
5 |
50 |
45 |
20 |
■ Multiple Piping Models
Additional charge (g) = ((A Room Installation Length – Standard Length ) x 20g/m
+ (B Room Installation Length – Standard Length ) x 20g/m +.. )
-CF(Correction Factor) x 150
CF = Max. number of connectable indoor unit – Total number of connected indoor unit
■ Distributor type Models
Additional charge (g) = (( Total Main piping Length - Main Standard Length ) x 50g/m
+(A Room Branch Length – Standard Length ) x 20g/m
+(B Room Branch Length – Standard Length ) x 20g/m
+(C Room Branch Length – Standard Length ) x 20g/m +.. ) - CF(Correction Factor) x 100
CF = Max. number of connectable indoor unit – Total number of connected indoor unit
Additional Charge Calculation Example-1
Ex) A7UW406FA3
A A
C
|
|
|
|
a |
|
|
b |
|
|
c |
||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
7k |
|
|
9k |
|
|
9k |
|
||
|
|
|
|
|
|
|
|
|
|
|
|
|
B |
|
|
|
|
|
|
|
|
||||
|
|
|
|
|
|
d |
|
|
e |
|||
|
|
|
|
|
|
|
|
|||||
|
|
|
|
|
|
|
|
|||||
|
|
|
|
|
|
|
|
|
|
|
||
|
|
|
|
|
|
9k |
|
|
|
18k |
•Total main pipe(A+B+C) = 30m
•Each branch pipe a = 10m
b = 8m c = 5m d = 3m e = 10m
Additional Charge
=((30-5) x 50 + (10-5) x 20 + (8-5) x 20
+(5-5) x 20 + (3-5) x 20 + (10-5) x 20) - (7-5) x 100 = 1270g
<![endif]>ENGLISH
Installation Manual 9
Installation of Indoor, Outdoor Unit
Preparing
work
for
Installation
(ART
COOL
Type
Only)
Open panel front
1.First, push the front panel backward and lift it up to remove the two screws.
2.The moment of lifting the both lower parts of panel front, you can hear sound this panel came out, In this time panel front is separated
3.After pull down this panel a bit, and separate connecting wire with product.
Panel Front |
Connector |
Panel Front |
Connector |
Remove cover pipe and cover side
1.Remove two screws(for fixing cover pipe)
2.Pull up the cover side of desired connecting direction, then cover side is separated.
3.In case of connecting direction is left or right, path through the hole of cover side.
CAUTION: After removing the pipe hole, cut the burr for safety.
NOTICE When connecting pipe path through rear wall, don’t remove the hole.
Drain hose junction
1.Remove the rubber stopple of desired direction of drainage.
2.As the following picture, Insert drain hose in the handle of drain pan, and join drain hose and connecting hose.
Pipe hole
Adhesive |
Only one |
|
|
desiring direction |
|
Connecting |
|
|
part |
|
|
Drain |
rubber cap |
|
hose |
||
|
10 Multi Air Conditioner
Installation of Indoor, Outdoor Unit
Sticking the installation
guide map
and
fixing
Indoor unit (ART
COOL
Type
Only)
Put an Installation Guide Map on the desired surface. |
Adjust level even by level guage and fix to installation |
|||
|
for reference on the wall. |
INSTALLATION |
|
|
INSTALLATION GUIDE MAP |
Horizontality |
|
|
|
|
|
GUIDE |
|
|
|
|
|
MAP |
|
|
|
|
|
Make a hole with diameter of 6mm and depth of 30-35mm when piercing a screw point.
INSTAIIATION
GUIDE M
AP
Drive the fore plastic anchors into drilled points.
INSTALLATION |
GUIDE |
|
|
MAP |
|
|
|
Plastic anchors
Hang the hole of product at the upper screws. (In this time, Remove the map)
(Falling attention)
INSTALLATION G
UIDE MAP
Hanger hole (Rear side of
product)
Check the fixed product with light power.
Drill the piercing part for connecting pipe as diameter 50mm. (In case of piercing rear surface)
Refer to No. 5 on this page when making a hole in the wall.
First, Drive the two points of the upper parts by screws (Leave 10mm for hanging product)
10mm |
INSTALLATION |
|
|
|
GU |
Drive the lower parts after facing the hole of product with plastic anchors, and fix completely the upper screws.
Plastic anchors
In case of nothing wrong in the matter, connect the pipe and the wire. (Installation manual reference)
<![endif]>ENGLISH
Drill
a
hole
in
the
wall
•Drill the piping hole with a ø70mm hole core drill. Drill the piping hole at either the right or the left with the hole slightly slanted to the outdoor side.
Standard / ART COOL Deluxe type |
ART COOL type |
|
||
|
WALL |
|
WALL |
|
Indoor |
Outdoor |
Indoor |
Outdoor |
|
|
<![if ! IE]> <![endif]>5-7mm (3/16"~5/16") |
|
<![if ! IE]> <![endif]>5-7mm |
<![if ! IE]> <![endif]>(0.2"~0.3") |
Installation Manual 11
Flaring Work and Connection of Piping
Flaring Work and Connection of Piping
Flaring
work
Main cause for gas leakage is due to defect in flaring work. Carry out correct flaring work in the following procedure.
Cut the pipes and the cable.
1.Use the piping kit accessory or the pipes purchased locally.
2.Measure the distance between the indoor and the outdoor unit.
3.Cut the pipes a little longer than measured distance.
4.Cut the cable 1.5m longer than the pipe length.
Burrs removal
1.Completely remove all burrs from the cut cross section of pipe/tube.
2.Put the end of the copper tube/pipe in a downward direction as you remove burrs in order to avoid dropping burrs into the tubing.
Copper |
|
Slanted |
Uneven Rough |
pipe |
90° |
||
|
|
Pipe |
|
|
|
Reamer |
Point down
Putting nut on
•Remove flare nuts attached to indoor and outdoor unit, then put them on pipe/tube having completed burr removal.
(not possible to put them on after flaring work)
Flaring work
Flare nut
Copper tube
• Carry out flaring work using flaring tool as shown |
|
|
|
Handle |
||
below. |
|
|
|
<![if ! IE]> <![endif]>"A" |
|
|
• Firmly hold copper pipe in a die in the dimension |
Bar |
Bar |
|
|||
|
Yoke |
|||||
shown in the table above. |
|
|
|
|
||
|
|
|
|
|
||
Outside diameter |
A |
|
|
|
Cone |
|
|
|
|
|
|||
mm |
inch |
mm |
|
Copper pipe |
|
|
Ø6.35 |
1/4 |
1.1~1.3 |
|
|
||
|
|
|
|
|||
Ø9.52 |
3/8 |
1.5~1.7 |
|
|
Clamp handle |
Red arrow mark |
Ø12.7 |
1/2 |
1.6~1.8 |
|
|
|
|
|
|
|
|
|||
Ø15.88 |
5/8 |
1.6~1.8 |
|
|
|
|
Ø19.05 |
3/4 |
1.9~2.1 |
|
|
|
|
12 Multi Air Conditioner