LG 4300, 6040-DB Instructions Manual

© copyright 2006 12-239v3 LA GARD INC - A Member of The Kaba Group
4300 Dual-Handed Swingbolt or 6040-DB Deadbolt Lock Instructions
MANAGER PROGRAMMING
CHANGING YOUR CODE (Without eKEY or eKEYII)
ALWAYS PERFORM THIS OPERATION WITH THE DOOR OPEN
If your unit is programmed for Dual Code, each code must be changed independently.
1 Enter existing code and hold down the last digit until unit
double signals twice and the LED stays on.
2 Press the “0” key. 3 Enter your NEW six (6) digit code two times. m If a mistake is made wait thirty (30) seconds and repeat steps 1
- 3.
4 Test unit operation several times before closing the door.
• Valid Code Entry - Double signal after valid six (6) digit code is entered.
• Invalid Code Entry - Triple signal and old code is still valid.
MANAGER CODE MUST BE CHANGED PRIOR TO PERFORMING ANY ACTION OTHER THAN OPENING THE LOCK
OPENING THE LOCK (Without eKEY or eKEYII)
1 Enter valid six (6) digit code. 2 The unit will indicate a valid code entry with a double signal. 3 Within four (4) seconds open lock by either rotating the keypad
to open position (Clock-wise) or turning the handle to the open position.
4 Pull door open.
• Invalid Code Entry - Unit will signal three (3) times.
Suggested Keypad
ACTIVATING USER
(Manager Only, without e
KEY or eKEY
)
ALWAYS PERFORM THIS OPERATION WITH THE DOOR OPEN
1 Enter Manager code and hold down last digit of code until unit
double signals twice and the LED stays on.
2 PRESS 1. Unit signals twice. 3 Press User number, 2 to 9. Unit signals twice. 4 Enter NEW six (6) digit User code two times. 5 If a mistake is made wait thirty (30) seconds and repeat steps
1 - 4.
• Valid Code Entry - Double signal after valid six (6) digit code is entered.
• Invalid Code Entry - Triple signal and old code is still valid.
DISABLE USER
(Manager Only, without e
KEY or eKEY
)
ALWAYS PERFORM THIS OPERATION WITH THE DOOR OPEN
1 Enter Manager code and hold down last digit of code until unit
double signals twice and the LED stays on.
2 PRESS 2. Unit signals twice. 3 Press User number, 2 to 9. Unit signals once. 4 User is temporarily disabled. 5 If a mistake is made wait thirty (30) seconds and repeat steps
1 - 3.
• Valid Code Entry - Double signal after valid six (6) digit code is entered.
• Invalid Code Entry - Triple signal and old code is still valid.
STANDARD FEATURES MANAGER CODE
(Factory set to 1-2-3-4-5-6 or 7-8-9
depending on code length)
• Activate/Delete Users
• Enable/Disable Users
• Set Time Delay Values
• Open Lock
USER CODE
• Open Lock
• Change Code
TIME DELAY
• Delay period 1 - 99 minutes
• Open period 1 - 19 minutes
DUAL CODE
• Two codes required to open
SIGNAL TO DISABLE LOCK OPENING
(Optional Alarm Box
Required)
• Input signal disables opening of lock by valid code
WRONG TRY PENALTY
• Four (4) consecutive invalid codes initiates five minute delay period.
LOW BATTERY WARNING
• Repeated audio and visual signal (LED flashing and repeated beeping) during opening indicates battery low.
AUDIO AND VISUAL SIGNAL
• Double signal (LED flashes and unit beeps) indicates entry is valid or accepted.
• Triple signal indicates invalid or not accepted.
AUDIT TRAIL
• For audit features see LPAUDIT Software Package
3750-K
Round Entry
PC PROGRAMMABLE FEATURES MULTIPLE USERS
Up to nine (1 Manager and 8 Users) User # Installed 2 3 4 5 6 7 8 9
ACTIVE
CODE LENGTH
TIME DELAY OVERRIDE
• Ability to add second combination to override delay period
SILENT SIGNAL ALARM
(Optional Alarm Box Required)
• Duress signal if last number of code(s) is entered using one number higher or one number lower.
SIGNAL TO DISABLE LOCK
(Optional Alarm Box Required)
• Input signal disables all lock functions by valid code
e
KEY or
e
KEY
II
• Use of key and code required
Lock Choices
4300
Dual-Handed Swingbolt
6040-DB Deadbolt
All locks are shipped from the factory in Pre Set-up mode, with no features installed.
Lock will open when 1 is pressed.
Please follow LPAUDIT PC software instructions to initially configure locks to default settings.
4300 is a new part
number replacing the
6260
3125 Round
Entry
© copyright 2006 12-239v3 LA GARD INC - A Member of The Kaba Group
DELETE USER
(Manager Only, without
e
KEY or
e
KEY
II
)
ALWAYS PERFORM THIS OPERATION WITH THE DOOR OPEN
1 Enter Manager code and hold down last digit of code until unit double signals twice and the LED stays on. 2 PRESS 3. Unit signals twice. 3 Press User number, 2 to 9. Unit signals once. 4 User is deleted. 5 If a mistake is made wait thirty (30) seconds and repeat steps 1 - 3.
• Valid Code Entry - Double signal after valid six (6) digit code is entered.
• Invalid Code Entry - Triple signal and old code is still valid.
DUAL CODE OPERATION
(
If feature is active, without
e
KEY or
e
KEY
II
)
1 Must add second user to open lock. (See ADD USER)
Second User cannot be disabled or removed.
2 If Time Delay is active, one valid code will start Delay period.
Both codes required to open lock in Open period.
SET/CHANGE TIME DELAY VALUES
(Manager Only, without
e
KEY or
e
KEY
II
)
ALWAYS PERFORM THIS OPERATION WITH THE DOOR OPEN
1 Enter Manager code and hold down last digit of code until unit double signals twice and the LED stays on. 2 PRESS 9. Unit signals twice. 3 Enter Delay period value, from 00 to 99 minutes. For example five (5) minutes would be entered by pressing the 0 key and
then the 5 key.
4 Enter Open period value, from 00 to 19 minutes. For example two (2) minutes would be entered by pressing the 0 key and then
the 2 key. Unit will signal twice.
Note: Selecting 0000 minutes deactivates the Time Delay Feature.
5 Confirm all four values. Unit signals twice and feature is active.
NOTE: If Time Delay is active it may only be deactivated or delay value decreased in Open Period.
TIME DELAY OVERRIDE
(If feature is active, without
e
KEY or
e
KEY
II
)
Must add User 9. (See ADD USER)
- User 9 cannot be disabled or removed.
Entry of Override code during Delay period will open the lock.
SILENT SIGNAL ALARM
(If feature is active AND optional Alarm Box is connected to an alarm system.) Without
e
KEY or
e
KEY
II
.
Enter last digit of code one number higher or one number lower. Example: Code: 1-2-3-4-5-6
Duress: 1-2-3-4-5-5 or 1-2-3-4-5-7
The lock will open without any indication that the duress signal has been sent.
CHECK USER STATUS
(Manager Only, without
e
KEY or
e
KEY
II
)
ALWAYS PERFORM THIS OPERATION WITH THE DOOR OPEN
1 Enter Manager code and hold down last digit of code until unit double signals twice and the LED stays on. 2 PRESS AND HOLD DOWN 1. Unit signals twice. 3 Press User number, 2 to 9. 4 Unit will signal once is the user is active, twice is the user is disabled, three times if the User is available. The unit will signal
with one extended signal is the User is unavailable.
5 To exit PRESS 0 or 1.
RECEIVE AUDIT
(Manager Only, without
e
KEY or
e
KEY
II
)
This function requires Serial Interface (P/N 43087) and LGVIEW Software
1 Plug Interface into PC and open LGVIEW software on PC. 2 Connect Interface to front of keypad and click safe icon button on the PC software to begin acquisition. 3 Enter Manager code and hold down last digit of code until unit double signals twice and the LED stays on. 4 PRESS 7. Unit signals once and Audit will be sent. 5 Disconnect Interface Cable from PC and keypad.
REINSTATE USER
(Manager Only, without
e
KEY or
e
KEY
II
)
ALWAYS PERFORM THIS OPERATION WITH THE DOOR OPEN
1 Enter Manager code and hold down last digit of code until unit double signals twice and the LED stays on. 2 PRESS 1. Unit signals twice. 3 Press User number, 2 to 9. Unit signals once. 4 User is reinstated. 5 If a mistake is made wait thirty (30) seconds and repeat steps 1 - 3.
• Valid Code Entry - Double signal after valid six (6) digit code is entered.
• Invalid Code Entry - Triple signal and old code is still valid.
Loading...
+ 2 hidden pages