Many electrical and mechanical parts in this chassis have special safety-related characteristics. These parts are identified by in the
Schematic Diagram and Exploded View.
It is essential that these special safety parts should be replaced with the same components as recommended in this manual to prevent
Shock, Fire, or other Hazards.
Do not modify the original design without permission of manufacturer.
General Guidance
An isolation Transformer should always be used during the
servicing of a receiver whose chassis is not isolated from the AC
power line. Use a transformer of adequate power rating as this
protects the technician from accidents resulting in personal injury
from electrical shocks.
It will also protect the receiver and it's components from being
damaged by accidental shorts of the circuitry that may be
inadvertently introduced during the service operation.
If any fuse (or Fusible Resistor) in this TV receiver is blown,
replace it with the specified.
When replacing a high wattage resistor (Oxide Metal Film Resistor,
over 1 W), keep the resistor 10 mm away from PCB.
Keep wires away from high voltage or high temperature parts.
Before returning the receiver to the customer,
always perform an AC leakage current check on the exposed
metallic parts of the cabinet, such as antennas, terminals, etc., to
be sure the set is safe to operate without damage of electrical
shock.
Leakage Current Cold Check(Antenna Cold Check)
With the instrument AC plug removed from AC source, connect an
electrical jumper across the two AC plug prongs. Place the AC
switch in the on position, connect one lead of ohm-meter to the AC
plug prongs tied together and touch other ohm-meter lead in turn to
each exposed metallic parts such as antenna terminals, phone
jacks, etc.
If the exposed metallic part has a return path to the chassis, the
measured resistance should be between 1 MΩ and 5.2 MΩ.
When the exposed metal has no return path to the chassis the
reading must be infinite.
An other abnormality exists that must be corrected before the
receiver is returned to the customer.
Leakage Current Hot Check (See below Figure)
Plug the AC cord directly into the AC outlet.
Do not use a line Isolation Transformer during this check.
Connect 1.5 K / 10 watt resistor in parallel with a 0.15 uF capacitor
between a known good earth ground (Water Pipe, Conduit, etc.)
and the exposed metallic parts.
Measure the AC voltage across the resistor using AC voltmeter
with 1000 ohms/volt or more sensitivity.
Reverse plug the AC cord into the AC outlet and repeat AC voltage
measurements for each exposed metallic part. Any voltage
measured must not exceed 0.75 volt RMS which is corresponds to
0.5 mA.
In case any measurement is out of the limits specified, there is
possibility of shock hazard and the set must be checked and
repaired before it is returned to the customer.
Leakage Current Hot Check circuit
1.5 Kohm/10W
To Instrument's
exposed
METALLIC PARTS
Good Earth Ground
such as WATER PIPE,
CONDUIT etc.
AC Volt-meter
When 25A is impressed between Earth and 2nd Ground
for 1 second, Resistance must be less than 0.1
This specification sheet is applied to all of the LED LCD TV
with LD12D chassis.
2. Designation
(1) Because this is not a hot chassis, it is not necessary to use
an isolation transformer. However, the use of isolation
transformer will help protect test instrument.
(2) Adjustment must be done in the correct order.
(3) The adjustment must be performed in the circumstance of
25 ºC ± 5 ºC of temperature and 65 % ± 10 % of relative
humidity if there is no specific designation.
(4) The input voltage of the receiver must keep AC 100-240
V~, 50 / 60Hz.
(5) The receiver must be operated for about 5 minutes prior to
the adjustment when module is in the circumstance of over
15.
In case of keeping module is in the circumstance of 0 °C, it
should be placed in the circumstance of above 15 °C for 2
hours
In case of keeping module is in the circumstance of below 20 °C, it should be placed in the circumstance of above 15
°C for 3 hours.
[Caution]
When still image is displayed for a period of 20 minutes or
longer (especially where W/B scale is strong. Digital pattern
13ch and/or Cross hatch pattern 09ch), there can some
afterimage in the black level area.
3. Automatic Adjustment
3.1. ADC Adjustment
(1) Overview
ADC adjustment is needed to find the optimum black level
and gain in Analog-to-Digital device and to compensate
RGB deviation.
* If Adjust ADC is “OTP”, It doesn’t need ADC adjustment.
(GP3-BCM)
(2) Equipment & Condition
1) Jig (RS-232C protocol)
2) MSPG-925 Series Pattern Generator(MSPG-925FA,
pattern - 65)
A Each other connection to LAN Port of IP Hub and Jig
(2) LAN inspection solution
A LAN Port connection with PCB
A Network setting at MENU Mode of TV
A setting automatic IP
A Setting state confirmation
-> If automatic setting is finished, you confirm IP and
MAC Address.
3.4. Widevine Key Inspection
Widevine key Inspection
- Confirm key input Data at the “IN START” MENU Mode.
3.5. LAN PORT INSPECTION(PING TEST)
Connect SET -> LAN port == PC -> LAN Port
(1) Equipment setting
1) Play the LAN Port Test PROGRAM.
2) Input IP set up for an inspection to Test Program.
*IP Number : 12.12.2.2
(2) LAN PORT inspection (PING TEST)
1) Play the LAN Port Test Program.
2) Connect each other LAN Port Jack.
3) Play Test (F9) button and confirm OK Message.
4) Remove LAN cable.
3.6. Model name & Serial number Download
(1) Model name & Serial number D/L
A Press “Power on” key of service remote control.
(Baud rate : 115200 bps)
A Connect RS232 Signal Cable to RS-232 Jack.
A Write Serial number by use RS-232.
A Must check the serial number at Instart menu.
(2) Method & notice
A. Serial number D/L is using of scan equipment.
B. Setting of scan equipment operated by Manufacturing
Technology Group.
C. Serial number D/L must be conformed when it is
produced in production line, because serial number D/L
is mandatory by D-book 4.0.
* Manual Download (Model Name and Serial Number)
If the TV set is downloaded by OTA or service man,
sometimes model name or serial number is initialized.(Not
always)
There is impossible to download by bar code scan, so It
need Manual download.
a. Press the ‘instart’ key of ADJ remote control.
b. Go to the menu ‘5.Model Number D/L’ like below photo.
c. Input the Factory model name(ex 42LW950-ZA) or Serial
number like photo.
d. Check the model name Instart menu. -> Factory name
displayed. (ex 42LW750S-ZA)
e. Check the Diagnostics. (DTV country only) -> Buyer
Check whether the key was downloaded or not at ‘In Start’
menu. (Refer to below).
=> Check the Download to CI+ key value in LGset.
3.7.1. Check the method of CI+ Key value
(1) Check the method on Instart menu.
(2) Check the method of RS232C Command.
1) Into the main assembly mode (RS232 : aa 00 00)
2) Check the key download for transmitted command.
(RS232 : ci 00 10)
3) Result value
- Normally status for download : OKx
- Abnormally status for download : NGx
3.7.2. Check the method of CI+ Key value (RS232)
1) Into the main assembly mode (RS232 : aa 00 00)
2) Check the method of CI+ key by command (RS232 : ci
00 20)
3) Result value
i 01 OK 1d1852d21c1ed5dcx
3.8. WIFI MAC ADDRESS CHECK
(1) Using RS232
(2) Check the menu on in-start
4. Manual Adjustment
4.1. ADC Adjustment
ADC adjustment is needed because of OTP(Auto ADC adjustment)
4.2. EDID(The Extended Display Identification
Data)/DDC(Display Data Channel) download
(1) Overview
It is a VESA regulation. A PC or a MNT will display an
optimal resolution through information sharing without any
necessity of user input. It is a realization of “Plug and Play”.
(2) Equipment
- Since embedded EDID data is used, EDID download JIG,
HDMI cable and D-sub cable are not need.
- Adjust remote control
(3) Download method
1) Press ADJ key on the Adjustment remote control, then
select “12.EDID D/L”, By pressing Enter key, enter EDID
D/L menu.
2) Select [Start] button by pressing Enter key, HDMI1/
HDMI2/ HDMI3/ HDMI4/ RGB are Writing and display
OK or NG.
(4) EDID DATA
A HDMI
A RGB
CMD 1CMD 2Data 0
AA00
CMD 1CMD 2Data 0
CI10
CMD 1CMD 2Data 0
AA00
CMD 1CMD 2Data 0
CI20
CI+ key Value
H-freq(kHz)V-freq.(Hz)
Transmission[A][I][ ][Set ID][ ][20][Cr][O][K][X] or [NG]
- In the data of EDID, bellows may be different by S/W or
Input mode.
ⓐ Product ID
ⓑ Serial No. : Controlled on product line
ⓒ Month, Year: Controlled on production line:
ex) Monthly : ‘01’ -> ‘01’
Year : ‘2010’ -> ‘14’
ⓓ Model Name(Hex): LGTV
ⓔ Checksum: Changeable by total EDID data.
ⓕ Vendor Specific(HDMI)
4.3. White Balance Adjustment
4.3.1 Overview
(1) W/B adj. Objective & How-it-works
(2) Objective: To reduce each Panel’s W/B deviation
(3) How-it-works : When R/G/B gain in the OSD is at 192, it
means the panel is at its Full Dynamic Range. In order to
prevent saturation of Full Dynamic range and data, one of
R/G/B is fixed at 192, and the other two is lowered to find
the desired value.
(4) Adj. condition : normal temperature
1) Surrounding Temperature : 25 ºC ± 5 ºC
2) Warm-up time: About 5 Min
3) Surrounding Humidity : 20 % ~ 80 %
4.3.2 Equipment
1) Color Analyzer: CA-210 (LED Module : CH 14)
2) Adj. Computer(During auto adj., RS-232C protocol is needed)
3) Adjust Remote control
4) Video Signal Generator MSPG-925F 720p/216-Gray
(Model:204, Pattern:80IRE)
-> Only when internal pattern is not available
A Color Analyzer Matrix should be calibrated using CS-1000
2) Zero calibrate probe then place it on the center of the
Display.
3) Connect Cable. (RS-232C)
4) Select mode in adj. Program and begin adjustment.
5) When adjustment is complete (OK Sign), check adj.
status pre mode.(Warm, Medium, Cool)
6) Remove probe and RS-232C cable to complete adjustment.
A W/B Adj. must begin as start command “wb 00 00” , and
finish as end command “wb 00 ff”, and Adj. offset if need.
(2) Manual adjustment method
1) Set TV in Adjustment mode using POWER ON.
2) Zero Calibrate the probe of Color Analyzer, then place it on
the center of LCD module within 10 cm of the surface.
3) Press ADJ key -> EZ adjust using Adjustment remote
control -> 7. White-Balance then press the cursor to the
right(G) key.
(When key(G) is pressed 216 Gray internal pattern will
be displayed.)
4) One of R Gain / G Gain / B Gain should be fixed at 192,
and the rest will be lowered to meet the desired value.
5) Adj. is performed in COOL, MEDIUM, WARM 3 modes
of color temperature.
A If internal pattern is not available, use RF input. In EZ
Adj. menu 7.White Balance, you can select one of 2
Test-pattern: ON, OFF. Default is inner(ON). By
selecting OFF, you can adjust using RF signal in 216
Gray pattern.
A Adj. condition and cautionary items
1) Lighting condition in surrounding area
Surrounding lighting should be lower 10 lux. Try to
isolate adj. area into dark surrounding.
2) Probe location : Color Analyzer(CA-210) probe should
be within 10 cm and perpendicular of the module
surface (80° ~ 100°)
3) Aging time
- After Aging Start, Keep the Power ON status during 5
Minutes.
- In case of LCD, Back-light on should be checked
using no signal or Full-white pattern.
4.3.6. Reference(White Balance Adj. coordinate and
temperature)
A Luminance : 204 Gray
A Standard color coordinate and temperature using CS-1000
(over 26 inch)
A Standard color coordinate and temperature using CA-210
(CH 14)
4.3.7. ALELF & Edge LED White balance table
A Edge LED module change color coordinate because of
aging time.
A Apply under the color coordinate table, for compensated
aging time.
[ALELF]
4.4. Wireless function check
Step 1) Connect set and Dongle of Wireless to Cable of HDMI
& TTA 20Pin
Step 2) At OSD of SET, check the message like Fig.3
Step 3) Detach Cable of Wireless Dongle
Step 1) Turn on TV.
Step 2) Press EYE key of Adjustment remote control.
Step 3) Cover the Eye Q II sensor on the front of the using
your hand and wait for 6 seconds.
Step 4) Confirm that R/G/B value is lower than 10 of the “Raw
Data (Sensor data, Back light)”. If after 6 seconds,
R/G/B value is not lower than 10, replace Eye Q II
sensor.
Step 5) Remove your hand from the Eye Q II sensor and wait
for 6 seconds.
Step 6) Confirm that “ok” pop up. If change is not seen,
replace Eye Q II sensor.
4.6. Local Dimming Function Check
(1) Turn on TV.
(2) At the Local Dimming mode, module Edge Backlight
moving Top to Bottom Back light of IOP module moving.
(3) Confirm the Local Dimming mode.
(4) Press “exit” key
4.7. Magic Motion Remote control test
- Equipment : RF Remote control for test, IR-KEY-Code
Remote control for test
- You must confirm the battery power of RF-Remote control
before test.(recommend that change the battery per every lot)
- Sequence (test)
1) if you select the ‘start key(Mute)’ on the controller, you can
pairing with the TV SET.
2) You can check the cursor on the TV Screen, when select
the ‘OK’ key on the controller.
3) You must remove the pairing with the TV Set by select
‘Vol+(STOP)’ key on the controller.
4.8. RF emitter inspection
(1) Start 3D pattern inspection
(2) If RF emitter signal is correctly received to RF receiver, the
lamp of RF tester turn on.
4.9. Option selection per country
(1) Overview
- Option selection is only done for models in Non-EU.
- Applied model: LD12D/N Chassis applied EU model.
(2) Method
1) Press ADJ key on the Adjustment remote control, then
select Country Group Menu.
2) Depending on destination, select Country Group Code
04 or Country Group EU then on the lower Country
option, select US, CA, MX. Selection is done using +, or
GF KEY.
4.10. Tool Option selection
- Method : Press Adj. key on the Adjustment remote control,
then select Tool option.
4.11. Ship-out mode check(In-stop)
After final inspection, press IN-STOP key of the Adjustment
remote control and check that the unit goes to Stand-by mode.
2. CVBS, Component: 1 KHz sine wave signal 0.4 Vrms
3. RGB PC: 1 KHz sine wave signal 0.7 Vrms
7. USB S/W download(option, service only)
1) Put the USB Stick to the USB socket.
2) Automatically detecting update file in USB Stick.
- If your downloaded program version in USB Stick is Low,
it didn’t work. But your downloaded version is High, USB
data is automatically detecting.
3) Show the message “Copying files from memory”.
4) Updating is starting.
5) Updating Completed, The TV will restart automatically.
6) If your TV is turned on, check your updated version and
Tool option. (explain the Tool option, next stage)
* If downloading version is more high than your TV have, TV
can lost all channel data. In this case, you have to channel
recover. if all channel data is cleared, you didn’t have a
DTV/ATV test on production line.
* After downloading, have to adjust TOOL OPTION again.
1) Push “IN-START” key in service remote control.
2) Select “Tool Option 1” and push “OK” key.
3) Punch in the number.(Each model has their number.)
No.ItemMin. Typ. Max. Unit
1. Audio practical max1012WEQ Off
Output, L/RAVL Off
(Distortion=10 %8.99.8 Vrms Clear Voice Off
max Output)
2. Speaker (8 Ω1012WEQ On
Impedance)AVL On
Clear Voice On
- 15 -
LGE Internal Use OnlyCopyright LG Electronics. Inc. All rights reserved.
Only for training and service purposes
310
560
120
121
541
810
540
530
800
LV1
LV2
521
510
500
A10
A5
A2
A23
A22
400
300
200
910
700
710
900
EXPLODED VIEW
Many electrical and mechanical parts in this chassis have special safety-related characteristics. These
parts are identified by in the Schematic Diagram and EXPLODED VIEW.
It is essential that these special safety parts should be replaced with the same components as
recommended in this manual to prevent X-RADIATION, Shock, Fire, or other Hazards.
Do not modify the original design without permission of manufacturer.
CI_ADDR[8]:
0: RESETOUTb (in On/Off only) stay asserted until software releases them.
1: Fix amount of delay for de-assertion on RESETOUTb (in On/IOff only)
at end of RESETb pulse (O)
NAND_DATA[3]:
0: MIPS will boot from external flash (O)
1: MIPS will boot from ROM
THE SYMBOL MARK OF THIS SCHEMETIC DIAGRAM INCORPORATES
SPECIAL FEATURES IMPORTANT FOR PROTECTION FROM X-RADIATION.
FILRE AND ELECTRICAL SHOCK HAZARDS, WHEN SERVICING IF IS
ESSENTIAL THAT ONLY MANUFATURES SPECFIED PARTS BE USED FOR
THE CRITICAL COMPONENTS IN THE SYMBOL MARK OF THE SCHEMETIC.
THE SYMBOL MARK OF THIS SCHEMETIC DIAGRAM INCORPORATES
SPECIAL FEATURES IMPORTANT FOR PROTECTION FROM X-RADIATION.
FILRE AND ELECTRICAL SHOCK HAZARDS, WHEN SERVICING IF IS
ESSENTIAL THAT ONLY MANUFATURES SPECFIED PARTS BE USED FOR
THE CRITICAL COMPONENTS IN THE SYMBOL MARK OF THE SCHEMETIC.
Run Along COMP_Y_IN,COMP_Pr_IN,COMP_Pb_IN/SC R,G,B Trace
INCM_R
INCM_G
INCM_B
INCM_VID_COMP1
INCM_VID_AV2
INCM_TUNER
INCM_VID_AV1
INCM_VID_SC/COMP2
BCM35230_with_CAP_220pF
IC101-*1
LGE35230
B6
BCM_CAP
VI_R
A6
VI_INCM_R
C7
VI_G
A7
VI_INCM_G
B7
VI_B
C8
VI_INCM_B
C13
HSYNC_IN
A13
VSYNC_IN
C9
VI_Y1
A9
VI_PR1
B9
VI_PB1
B8
VI_INCM_COMP1
C11
VI_SC_R1
A10
VI_SC_G1
B10
VI_SC_B1
C10
VI_INCM_SC1
D10
VI_FB_1/GPIO
F13
VI_FS1
A12
VI_SC_R2
C12
VI_SC_G2
B12
VI_SC_B2
B11
VI_INCM_SC2
E12
VI_FB_2/GPIO
E14
VI_FS2
E15
VI_L1
F17
VI_C1_1
E16
VI_INCM_LC1_1
F14
VI_C1_2
E11
VI_INCM_LC1_2
C18
VI_CVBS1
B18
VI_INCM_CVBS1
A18
VI_CVBS2
C19
VI_INCM_CVBS2
A19
VI_CVBS3
B19
VI_INCM_CVBS3
C20
VI_CVBS4
B20
VI_INCM_CVBS4
E19
VI_SIF1_1
D19
VI_INCM_SIF1_1
E10
VI_SIF1_2
F11
VI_INCM_SIF1_2
SCL3_3.3V
SDA3_3.3V
+3.3V_Normal
R302
R301
1.2K
1.2K
C301
C302
33pF
33pF
50V
50V
PHONE JACK
INCM_AUD_SC/COMP2
M_REMOTE_TX
PC_L_IN
PC_R_IN
AV1_L_IN
AV1_R_IN
INCM_AUD_AV1
AV2_L_IN
AV2_R_IN
INCM_AUD_AV2
SC/COMP2_L_IN
SC/COMP2_R_IN
C3051uF10V
C3061uF10V
C3071uF10V
C3081uF10V
C3091uF10V
C3101uF10V
C3111uF10V
C3121uF10V
C3131uF10V
C3141uF10V
C3151uF10V
C3161uF10V
NON_BCM_CAP
SPDIF_INC_P
SPDIF_INC_N
SPDIF_IND_P
SPDIF_IND_N
I2SSCK_IN/GPIO
I2SWS_IN
I2SSD_IN/GPIO
AADC_LINE_L1
AADC_LINE_R1
AADC_INCM1
AADC_LINE_L2
AADC_LINE_R2
AADC_INCM2
AADC_LINE_L3
AADC_LINE_R3
AADC_INCM3
AADC_LINE_L4
AADC_LINE_R4
AADC_INCM4
AADC_LINE_L5
AADC_LINE_R5
AADC_INCM5
AADC_LINE_L6
AADC_LINE_R6
AADC_INCM6
AADC_LINE_L7
AADC_LINE_R7
AADC_INCM7
IC101
I2SSCK_OUTA/GPIO
I2SWS_OUTA/GPIO
I2SSD_OUTA0/GPIO
I2SSOSCK_OUTA/GPIO
I2SSD_OUTA1/GPIO
I2SSD_OUTA2/GPIO
I2SSCK_OUTC/GPIO
I2SWS_OUTC/GPIO
I2SSD_OUTC/GPIO
I2SSOSCK_OUTC/GPIO
I2SSCK_OUTD/GPIO
I2SWS_OUTD/GPIO
I2SSD_OUTD/GPIO
I2SSOSCK_OUTD/GPIO
SPDIF_OUTA/GPIO
LGE35230(BCM35230KFSBG)
B15
C15
C14
B14
G4
F4
G5
C25
B24
A24
E22
E23
D23
C24
C23
B23
E21
D21
D22
B22
C22
A22
F21
D20
E20
A21
C21
B21
AUDMUTE_0/GPIO
AUDMUTE_1
ADAC_AL_N
ADAC_AL_P
ADAC_AR_N
ADAC_AR_P
ADAC_CL_N
ADAC_CL_P
ADAC_CR_N
ADAC_CR_P
ADAC_DL_N
ADAC_DL_P
ADAC_DR_N
ADAC_DR_P
AF8
AF9
AG9
AC9
AD8
AD9
E2
F2
E3
F3
G2
G3
G1
H1
B13
AG8
E13
C28
C27
D28
D27
C26
A27
B27
B28
B25
A25
A26
B26
R326100
R327100
R328100
R329100
TU_RESET_SUB
HP_DET
AV1_CVBS_DET
TU_RESET
SC_RE1
SC_RE2INCM_AUD_PC
/RST_HUB
S2_RESET
SPDIF_OUT
HP_LOUT_N
HP_LOUT_P
HP_ROUT_N
HP_ROUT_P
SCART1_Lout_N
SCART1_Lout_P
SCART1_Rout_N
SCART1_Rout_P
C337
22pF
OPT
C338
22pF
OPT
C339
22pF
OPT
C340
33pF
OPT
AUD_SCK
AUD_LRCK
AUD_LRCH
AUD_MASTER_CLK
Near
Near
Near
Near
Near
JK1102
JK1103
JK2501
JK1104
JK801
TU2101/2
TU2201/2/3
R3210
R3220
R3230
R3240
AUDIO INCM
Route Between AV1_L_IN & AV1_R_IN Trace
Route Between SC/COMP2_L_IN & SC/COMP2_R_IN Trace
Route Between AV2_L_IN & AV2_R_IN Trace
Route Between PC_L_IN & PC_R_IN Trace
Route Along With TUNER_SIF_IF_N
INCM_AUD_AV1
INCM_AUD_SC/COMP2
INCM_AUD_AV2
INCM_AUD_PC
INCM_SIF
THE SYMBOL MARK OF THIS SCHEMETIC DIAGRAM INCORPORATES
SPECIAL FEATURES IMPORTANT FOR PROTECTION FROM X-RADIATION.
FILRE AND ELECTRICAL SHOCK HAZARDS, WHEN SERVICING IF IS
ESSENTIAL THAT ONLY MANUFATURES SPECFIED PARTS BE USED FOR
THE CRITICAL COMPONENTS IN THE SYMBOL MARK OF THE SCHEMETIC.
THE SYMBOL MARK OF THIS SCHEMETIC DIAGRAM INCORPORATES
SPECIAL FEATURES IMPORTANT FOR PROTECTION FROM X-RADIATION.
FILRE AND ELECTRICAL SHOCK HAZARDS, WHEN SERVICING IF IS
ESSENTIAL THAT ONLY MANUFATURES SPECFIED PARTS BE USED FOR
THE CRITICAL COMPONENTS IN THE SYMBOL MARK OF THE SCHEMETIC.
THE SYMBOL MARK OF THIS SCHEMETIC DIAGRAM INCORPORATES
SPECIAL FEATURES IMPORTANT FOR PROTECTION FROM X-RADIATION.
FILRE AND ELECTRICAL SHOCK HAZARDS, WHEN SERVICING IF IS
ESSENTIAL THAT ONLY MANUFATURES SPECFIED PARTS BE USED FOR
THE CRITICAL COMPONENTS IN THE SYMBOL MARK OF THE SCHEMETIC.
THE SYMBOL MARK OF THIS SCHEMETIC DIAGRAM INCORPORATES
SPECIAL FEATURES IMPORTANT FOR PROTECTION FROM X-RADIATION.
FILRE AND ELECTRICAL SHOCK HAZARDS, WHEN SERVICING IF IS
ESSENTIAL THAT ONLY MANUFATURES SPECFIED PARTS BE USED FOR
THE CRITICAL COMPONENTS IN THE SYMBOL MARK OF THE SCHEMETIC.
THE SYMBOL MARK OF THIS SCHEMETIC DIAGRAM INCORPORATES
SPECIAL FEATURES IMPORTANT FOR PROTECTION FROM X-RADIATION.
FILRE AND ELECTRICAL SHOCK HAZARDS, WHEN SERVICING IF IS
ESSENTIAL THAT ONLY MANUFATURES SPECFIED PARTS BE USED FOR
THE CRITICAL COMPONENTS IN THE SYMBOL MARK OF THE SCHEMETIC.
THE SYMBOL MARK OF THIS SCHEMETIC DIAGRAM INCORPORATES
SPECIAL FEATURES IMPORTANT FOR PROTECTION FROM X-RADIATION.
FILRE AND ELECTRICAL SHOCK HAZARDS, WHEN SERVICING IF IS
ESSENTIAL THAT ONLY MANUFATURES SPECFIED PARTS BE USED FOR
THE CRITICAL COMPONENTS IN THE SYMBOL MARK OF THE SCHEMETIC.
THE SYMBOL MARK OF THIS SCHEMETIC DIAGRAM INCORPORATES
SPECIAL FEATURES IMPORTANT FOR PROTECTION FROM X-RADIATION.
FILRE AND ELECTRICAL SHOCK HAZARDS, WHEN SERVICING IF IS
ESSENTIAL THAT ONLY MANUFATURES SPECFIED PARTS BE USED FOR
THE CRITICAL COMPONENTS IN THE SYMBOL MARK OF THE SCHEMETIC.
THE SYMBOL MARK OF THIS SCHEMETIC DIAGRAM INCORPORATES
SPECIAL FEATURES IMPORTANT FOR PROTECTION FROM X-RADIATION.
FILRE AND ELECTRICAL SHOCK HAZARDS, WHEN SERVICING IF IS
ESSENTIAL THAT ONLY MANUFATURES SPECFIED PARTS BE USED FOR
THE CRITICAL COMPONENTS IN THE SYMBOL MARK OF THE SCHEMETIC.
THE SYMBOL MARK OF THIS SCHEMETIC DIAGRAM INCORPORATES
SPECIAL FEATURES IMPORTANT FOR PROTECTION FROM X-RADIATION.
FILRE AND ELECTRICAL SHOCK HAZARDS, WHEN SERVICING IF IS
ESSENTIAL THAT ONLY MANUFATURES SPECFIED PARTS BE USED FOR
THE CRITICAL COMPONENTS IN THE SYMBOL MARK OF THE SCHEMETIC.
+3.3V_USB
/RST_HUB
USB
3AU04S-305-ZC-(LG)
JK1202
1234
5
L1204
MLB-201209-0120P-N2
120-ohm
C1230
C1219
100uF
10uF
16V
10V
OPT
D1208
RCLAMP0502BA
BCM35230
USB + WIFI
IC1203
AP2191DSG
NC
8
OUT_2
7
OUT_1
6
FLG
5
EAN61849601
D1204
CDS3C05HDMI1
5.6V
+3.3V_Normal
GND
1
IN_1
2
IN_2
3
EN
4
D1206
CDS3C05HDMI1
5.6V
R1220
4.7K
OPT
USB_CTL2
R12280
R12290
R12260
R12270
NON_WIFI
NON_WIFI
NON_WIFI
NON_WIFI
R1222
2.7K
SIDE_USB_CTL2
SIDE_USB_OCD2
USB_DM2
USB_DP2
WIFI_DM
WIFI_DP
12
+5V_USB
C1223
0.1uF
/USB_OCD2
Loading...
+ 60 hidden pages
You need points to download manuals.
1 point = 1 manual.