LG 42LV4500, 47LV4500, 55LV4500 Schematic

LED LCD TV
SERVICE MANUAL
CAUTION
BEFORE SERVICING THE CHASSIS, READ THE SAFETY PRECAUTIONS IN THIS MANUAL.
CHASSIS : LC01U
MODEL: 42/47/55LV4500
http://biz.lgservice.com
Internal Use Only
LGE Internal Use OnlyCopyright ©2011 LG Electronics. Inc. All rights reserved.
Only for training and service purposes
- 2 -
CONTENTS
CONTENTS .............................................................................................. 2
PRODUCT SAFETY ................................................................................. 3
SPECIFICATION ....................................................................................... 6
ADJUSTMENT INSTRUCTION ................................................................ 9
BLOCK DIAGRAM....................................................................................13
EXPLODED VIEW .................................................................................. 15
SCHEMATIC CIRCUIT DIAGRAM ..............................................................
LGE Internal Use OnlyCopyright ©2011 LG Electronics. Inc. All rights reserved.
Only for training and service purposes
- 3 -
SAFETY PRECAUTIONS
Many electrical and mechanical parts in this chassis have special safety-related characteristics. These parts are identified by in the Schematic Diagram and Exploded View. It is essential that these special safety parts should be replaced with the same components as recommended in this manual to prevent Shock, Fire, or other Hazards. Do not modify the original design without permission of manufacturer.
General Guidance
An isolation Transformer should always be used during the servicing of a receiver whose chassis is not isolated from the AC power line. Use a transformer of adequate power rating as this protects the technician from accidents resulting in personal injury from electrical shocks.
It will also protect the receiver and it's components from being damaged by accidental shorts of the circuitry that may be inadvertently introduced during the service operation.
If any fuse (or Fusible Resistor) in this TV receiver is blown, replace it with the specified.
When replacing a high wattage resistor (Oxide Metal Film Resistor, over 1 W), keep the resistor 10 mm away from PCB.
Keep wires away from high voltage or high temperature parts.
Before returning the receiver to the customer,
always perform an AC leakage current check on the exposed metallic parts of the cabinet, such as antennas, terminals, etc., to be sure the set is safe to operate without damage of electrical shock.
Leakage Current Cold Check(Antenna Cold Check)
With the instrument AC plug removed from AC source, connect an electrical jumper across the two AC plug prongs. Place the AC switch in the on position, connect one lead of ohm-meter to the AC plug prongs tied together and touch other ohm-meter lead in turn to each exposed metallic parts such as antenna terminals, phone jacks, etc. If the exposed metallic part has a return path to the chassis, the measured resistance should be between 1 MΩ and 5.2 MΩ. When the exposed metal has no return path to the chassis the reading must be infinite. An other abnormality exists that must be corrected before the receiver is returned to the customer.
Leakage Current Hot Check (See below Figure)
Plug the AC cord directly into the AC outlet.
Do not use a line Isolation Transformer during this check.
Connect 1.5 K / 10 watt resistor in parallel with a 0.15 uF capacitor between a known good earth ground (Water Pipe, Conduit, etc.) and the exposed metallic parts. Measure the AC voltage across the resistor using AC voltmeter with 1000 ohms/volt or more sensitivity. Reverse plug the AC cord into the AC outlet and repeat AC voltage measurements for each exposed metallic part. Any voltage measured must not exceed 0.75 volt RMS which is corresponds to
0.5 mA. In case any measurement is out of the limits specified, there is possibility of shock hazard and the set must be checked and repaired before it is returned to the customer.
Leakage Current Hot Check circuit
1.5 Kohm/10W
To Instrument's exposed METALLIC PARTS
Good Earth Ground such as WATER PIPE, CONDUIT etc.
AC Volt-meter
When 25A is impressed between Earth and 2nd Ground for 1 second, Resistance must be less than 0.1
*Base on Adjustment standard
IMPORTANT SAFETY NOTICE
0.15 uF
LGE Internal Use OnlyCopyright ©2011 LG Electronics. Inc. All rights reserved.
Only for training and service purposes
- 4 -
CAUTION: Before servicing receivers covered by this service manual and its supplements and addenda, read and follow the
SAFETY PRECAUTIONS on page 3 of this publication. NOTE: If unforeseen circumstances create conflict between the
following servicing precautions and any of the safety precautions on page 3 of this publication, always follow the safety precautions. Remember: Safety First.
General Servicing Precautions
1. Always unplug the receiver AC power cord from the AC power source before; a. Removing or reinstalling any component, circuit board
module or any other receiver assembly.
b. Disconnecting or reconnecting any receiver electrical plug or
other electrical connection.
c. Connecting a test substitute in parallel with an electrolytic
capacitor in the receiver. CAUTION: A wrong part substitution or incorrect polarity installation of electrolytic capacitors may result in an explosion hazard.
2. Test high voltage only by measuring it with an appropriate high voltage meter or other voltage measuring device (DVM, FETVOM, etc) equipped with a suitable high voltage probe. Do not test high voltage by "drawing an arc".
3. Do not spray chemicals on or near this receiver or any of its assemblies.
4. Unless specified otherwise in this service manual, clean electrical contacts only by applying the following mixture to the contacts with a pipe cleaner, cotton-tipped stick or comparable non-abrasive applicator; 10 % (by volume) Acetone and 90 % (by volume) isopropyl alcohol (90 % - 99 % strength) CAUTION: This is a flammable mixture. Unless specified otherwise in this service manual, lubrication of contacts in not required.
5. Do not defeat any plug/socket B+ voltage interlocks with which receivers covered by this service manual might be equipped.
6. Do not apply AC power to this instrument and/or any of its electrical assemblies unless all solid-state device heat sinks are correctly installed.
7. Always connect the test receiver ground lead to the receiver chassis ground before connecting the test receiver positive lead. Always remove the test receiver ground lead last.
8. Use with this receiver only the test fixtures specified in this
service manual.
CAUTION: Do not connect the test fixture ground strap to any heat sink in this receiver.
Electrostatically Sensitive (ES) Devices
Some semiconductor (solid-state) devices can be damaged easily by static electricity. Such components commonly are called Electrostatically Sensitive (ES) Devices. Examples of typical ES devices are integrated circuits and some field-effect transistors and semiconductor "chip" components. The following techniques should be used to help reduce the incidence of component damage caused by static by static electricity.
1. Immediately before handling any semiconductor component or semiconductor-equipped assembly, drain off any electrostatic charge on your body by touching a known earth ground. Alternatively, obtain and wear a commercially available discharging wrist strap device, which should be removed to prevent potential shock reasons prior to applying power to the unit under test.
2. After removing an electrical assembly equipped with ES devices, place the assembly on a conductive surface such as aluminum foil, to prevent electrostatic charge buildup or exposure of the assembly.
3. Use only a grounded-tip soldering iron to solder or unsolder ES devices.
4. Use only an anti-static type solder removal device. Some solder removal devices not classified as "anti-static" can generate electrical charges sufficient to damage ES devices.
5. Do not use freon-propelled chemicals. These can generate electrical charges sufficient to damage ES devices.
6. Do not remove a replacement ES device from its protective package until immediately before you are ready to install it. (Most replacement ES devices are packaged with leads electrically shorted together by conductive foam, aluminum foil or comparable conductive material).
7. Immediately before removing the protective material from the leads of a replacement ES device, touch the protective material to the chassis or circuit assembly into which the device will be installed. CAUTION: Be sure no power is applied to the chassis or circuit, and observe all other safety precautions.
8. Minimize bodily motions when handling unpackaged replacement ES devices. (Otherwise harmless motion such as the brushing together of your clothes fabric or the lifting of your foot from a carpeted floor can generate static electricity sufficient to damage an ES device.)
General Soldering Guidelines
1. Use a grounded-tip, low-wattage soldering iron and appropriate tip size and shape that will maintain tip temperature within the range or 500
°
F to 600 °F.
2. Use an appropriate gauge of RMA resin-core solder composed of 60 parts tin/40 parts lead.
3. Keep the soldering iron tip clean and well tinned.
4. Thoroughly clean the surfaces to be soldered. Use a mall wire­bristle (0.5 inch, or 1.25 cm) brush with a metal handle. Do not use freon-propelled spray-on cleaners.
5. Use the following unsoldering technique a. Allow the soldering iron tip to reach normal temperature.
(500
°F to 600 °F)
b. Heat the component lead until the solder melts. c. Quickly draw the melted solder with an anti-static, suction-
type solder removal device or with solder braid. CAUTION: Work quickly to avoid overheating the circuit board printed foil.
6. Use the following soldering technique. a. Allow the soldering iron tip to reach a normal temperature
(500
°F to 600 °F)
b. First, hold the soldering iron tip and solder the strand against
the component lead until the solder melts.
c. Quickly move the soldering iron tip to the junction of the
component lead and the printed circuit foil, and hold it there only until the solder flows onto and around both the component lead and the foil. CAUTION: Work quickly to avoid overheating the circuit board printed foil.
d. Closely inspect the solder area and remove any excess or
splashed solder with a small wire-bristle brush.
SERVICING PRECAUTIONS
LGE Internal Use OnlyCopyright ©2011 LG Electronics. Inc. All rights reserved.
Only for training and service purposes
- 5 -
IC Remove/Replacement
Some chassis circuit boards have slotted holes (oblong) through which the IC leads are inserted and then bent flat against the circuit foil. When holes are the slotted type, the following technique should be used to remove and replace the IC. When working with boards using the familiar round hole, use the standard technique as outlined in paragraphs 5 and 6 above.
Removal
1. Desolder and straighten each IC lead in one operation by gently prying up on the lead with the soldering iron tip as the solder melts.
2. Draw away the melted solder with an anti-static suction-type solder removal device (or with solder braid) before removing the IC.
Replacement
1. Carefully insert the replacement IC in the circuit board.
2. Carefully bend each IC lead against the circuit foil pad and solder it.
3. Clean the soldered areas with a small wire-bristle brush. (It is not necessary to reapply acrylic coating to the areas).
"Small-Signal" Discrete Transistor Removal/Replacement
1. Remove the defective transistor by clipping its leads as close as possible to the component body.
2. Bend into a "U" shape the end of each of three leads remaining on the circuit board.
3. Bend into a "U" shape the replacement transistor leads.
4. Connect the replacement transistor leads to the corresponding leads extending from the circuit board and crimp the "U" with long nose pliers to insure metal to metal contact then solder each connection.
Power Output, Transistor Device Removal/Replacement
1. Heat and remove all solder from around the transistor leads.
2. Remove the heat sink mounting screw (if so equipped).
3. Carefully remove the transistor from the heat sink of the circuit board.
4. Insert new transistor in the circuit board.
5. Solder each transistor lead, and clip off excess lead.
6. Replace heat sink.
Diode Removal/Replacement
1. Remove defective diode by clipping its leads as close as possible to diode body.
2. Bend the two remaining leads perpendicular y to the circuit board.
3. Observing diode polarity, wrap each lead of the new diode around the corresponding lead on the circuit board.
4. Securely crimp each connection and solder it.
5. Inspect (on the circuit board copper side) the solder joints of the two "original" leads. If they are not shiny, reheat them and if necessary, apply additional solder.
Fuse and Conventional Resistor
Removal/Replacement
1. Clip each fuse or resistor lead at top of the circuit board hollow stake.
2. Securely crimp the leads of replacement component around notch at stake top.
3. Solder the connections. CAUTION: Maintain original spacing between the replaced component and adjacent components and the circuit board to prevent excessive component temperatures.
Circuit Board Foil Repair
Excessive heat applied to the copper foil of any printed circuit board will weaken the adhesive that bonds the foil to the circuit board causing the foil to separate from or "lift-off" the board. The following guidelines and procedures should be followed whenever this condition is encountered.
At IC Connections
To repair a defective copper pattern at IC connections use the following procedure to install a jumper wire on the copper pattern side of the circuit board. (Use this technique only on IC connections).
1. Carefully remove the damaged copper pattern with a sharp knife. (Remove only as much copper as absolutely necessary).
2. carefully scratch away the solder resist and acrylic coating (if used) from the end of the remaining copper pattern.
3. Bend a small "U" in one end of a small gauge jumper wire and carefully crimp it around the IC pin. Solder the IC connection.
4. Route the jumper wire along the path of the out-away copper pattern and let it overlap the previously scraped end of the good copper pattern. Solder the overlapped area and clip off any excess jumper wire.
At Other Connections
Use the following technique to repair the defective copper pattern at connections other than IC Pins. This technique involves the installation of a jumper wire on the component side of the circuit board.
1. Remove the defective copper pattern with a sharp knife. Remove at least 1/4 inch of copper, to ensure that a hazardous condition will not exist if the jumper wire opens.
2. Trace along the copper pattern from both sides of the pattern break and locate the nearest component that is directly connected to the affected copper pattern.
3. Connect insulated 20-gauge jumper wire from the lead of the nearest component on one side of the pattern break to the lead of the nearest component on the other side. Carefully crimp and solder the connections. CAUTION: Be sure the insulated jumper wire is dressed so the it does not touch components or sharp edges.
SPECIFICATION
.
4. Model General Specification
1. Application range
This is applied to the LCD/ LED LCD TV used LC01U chassis.
2. Requirement for Test
Each part is tested as below without special appointment.
1) Temperature : 25 ºC ± 5 ºC (77 ºF ± 9 ºF), CST : 40 ºC ± 5 ºC
2) Relative Humidity : 65 % ± 10 %
3) Power Voltage : Standard input voltage (AC 100-240 V~ 50 / 60 Hz) * Standard Voltage of each products is marked by models.
4)
and performance of each parts are followed
each d rawing an d
by part n umber in
accordance with BOM.
5) The receiver must be operated for about 5 minutes prior to
the adjustment.
3. Test method
1) Performance: LGE TV test method followed
- EMC:CE, IEC
No
Item Specification
Meas urem
ent
Result
1 Display Screen Device 42”/47”/55”Wide color display module CCFL/EEFL LCD 2 Aspect Ratio 16:9
3 LCD Module
42” TFT LCD FHD 47” TFT LCD FHD 55” TFT LCD FHD
LGD : 42/47/55LV4500
4 Storage Environment Temp. : -20 ~ 60 deg, Humidity : 10 ~ 90 %
5 Input Voltage 100-240V~ 50/60Hz
Power on (Blue)
42”LGD(FHD,100Hz)3DA
Typ:80W
42”LGD(FHD,100Hz) Edge
47”LGD(FHD,100Hz)3D
47”LGD(FHD,100Hz)3D
42”LGD(FHD,100Hz)
42”LGD(FHD) Edge
47”LGD(FHD,100Hz) Edge
47”LGD(FHD,100Hz) Edge
55”LGD(FHD,100Hz)3D
55”LGD(FHD,100Hz)3D
55”LGD(FHD,100Hz) Edge
55”LGD(FHD,100Hz) Edge
47”LGD(FHD,100Hz)3D
42”LGD(FHD,100Hz)
42”LGD(FHD) Edge
47”LGD(FHD,100Hz) Edge
55”LGD(FHD,100Hz)3D
55”LGD(FHD,100Hz) Edge
47”LGD(FHD,100Hz)3D
42”LGD(FHD,100Hz)
Edge
Edge
Edge Edge
Edge
Edge
42”LGD(FHD) Edge
47”LGD(FHD,100Hz) Edge
55”LGD(FHD,100Hz)3D
55”LGD(FHD,100Hz) Edge
Typ:91.3W
Typ:90.5W
Typ: 80.2 W
Typ:108.5W
Typ:108.5W
968.4(H) x 564.0 (V) x 10.8(B) / 22.9 mm
968.4(H) × 564(V) X 10.8(B)/18.3 mm(D)
1078.6(H) x 626.0 (V) x 10.8(B) / 22.9 mm (D)
968.4(H) x 564.0 (V) x 10.8(B) / 22.9 mm
1255.6(H) × 726.4(V) X 19.0(B)/10.8 mm(D)
1255.6(H) × 726.4(V) X 19.0(B)/10.8 mm(D)
0.4845 mm x 0.4845 mm
0.4845 mm x 0.4845 mm
0.5415 mm x 0.5415 mm
0.5415 mm x 0.5415 mm
0.630 mm x 0.630 mm
0.630 mm x 0.630 mm
6 Power Consumption
Module Size
Pixel Pitch
Back Light
Remark
- 6 -
Only for training and service purposes
LGE Internal Use OnlyCopyright ©2011 LG Electronics. Inc. All rights reserved.
- 7 -
LGE Internal Use OnlyCopyright ©2011 LG Electronics. Inc. All rights reserved.
Only for training and service purposes
5. Component Video Input (Y, CB/PB, CR/PR)
No.
Specification
Remark
Resolution H-freq(kHz) V-freq(Hz)
1. 720x480 15.73 60.00 SDTV,DVD 480i
2. 720x480 15.63 59.94 SDTV,DVD 480i
3. 720x480 31.47 59.94 480p
4. 720x480 31.50 60.00 480p
5. 720x576 15.625 50.00 SDTV,DVD 625 Line
6. 720x576 31.25 50.00 HDTV 576p
7. 1280x720 45.00 50.00 HDTV 720p
8. 1280x720 44.96 59.94 HDTV 720p
9. 1280x720 45.00 60.00 HDTV 720p
10. 1920x1080 31.25 50.00 HDTV 1080i
11. 1920x1080 33.75 60.00 HDTV 1080i
12. 1920x1080 33.72 59.94 HDTV 1080i
13. 1920x1080 56.250 50 HDTV 1080p
14. 1920x1080 67.5 60 HDTV 1080p
No.
Specification
Proposed Remark
Resolution H-freq(kHz) V-freq(Hz) Pixel Clock(MHz)
1. 720*400 31.468 70.08 28.321 For only DOS mode
2. 640*480 31.469 59.94 25.17 VESA Input 848*480 60 Hz, 852*480 60 Hz
-> 640*480 60 Hz Display
3. 800*600 37.879 60.31 40.00 VESA
4. 1024*768 48.363 60.00 65.00 VESA(XGA)
5. 1280*768 47.78 59.87 79.5 WXGA
6. 1360*768 47.72 59.8 84.75 WXGA FHD Model
7. 1366*768 47.56 59.6 84.75 WXGA WXGA Model
8. 1200*1024 63.901 60.02 100.075 SXGA FHD model
9. 1280*720 45 60 74.25 720p DTV Standard
10. 1920*1080 67.5 60 148.5 WUXGA FHD model
6. RGB (PC)
No
Item Specification
Meas urem
ent
Result Remark
Display Colors 1.06 Billion, 16.7 Milion Coating 3H, AG
- 8 -
LGE Internal Use OnlyCopyright ©2011 LG Electronics. Inc. All rights reserved.
Only for training and service purposes
7. HDMI Input
(1) DTV Mode
No. Resolution H-freq(kHz) V-freq.(Hz) Pixel clock(MHz) Proposed Remark
1. 720*400 31.468 70.08 28.321 HDCP
2. 640*480 31.469 59.94 25.17 VESA HDCP
3. 800*600 37.879 60.31 40.00 VESA HDCP
4. 1024*768 48.363 60.00 65.00 VESA(XGA) HDCP
5. 1280*768 47.78 59.87 79.5 WXGA HDCP
6. 1360*768 47.72 59.8 84.75 WXGA HDCP
7. 1280*720 45 60 74.25 HDCP
8. 1920*1080 67.5 60
148.5 WUXGA HDCP/FHD model
(2) PC Mode
No. Resolution H-freq(kHz) V-freq.(Hz) Pixel clock(MHz) Proposed Remark
1. 720*480 31.469/31.5 59.94/60 27.00/27.03 SDTV 480P
2. 720*576 31.25 50 54 SDTV 576P
3. 1280*720 37.500 50 74.25 HDTV 720P
4. 1280*720 44.96/45 59.94/60 74.17/74.25 HDTV 720P
5. 1920*1080 33.72/33.75 59.94/60 74.17/74.25 HDTV 1080I
6. 1920*1080 28.125 50.00 74.25 HDTV 1080I
7. 1920*1080 26.97/27 23.97/24 74.17/74.25 HDTV 1080P
8. 1920*1080 33.716/33.75 29.976 /30.00 74.25 HDTV 1080P
9. 1920*1080 56.250 50 148.5 HDTV 1080P
10. 1920*1080 67.43/67.5 59.94/60 148.35/148.50 HDTV 1080P
LGE Internal Use OnlyCopyright ©2011 LG Electronics. Inc. All rights reserved.
Only for training and service purposes
- 9 -
ADJUSTMENT INSTRUCTION
1. Application Range
This specification sheet is applied to all of the LCD/ LED LCD TV with LC01U chassis.
2. Designation
1) The adjust ment is according t o the order which i s
designated and which must be followed, according to the plan which can be changed only on agreeing.
2) Power Adjustment: Free Voltage
3) Magnetic Field Condition: Nil.
4) Input signal Unit: Product Specification Standard
5) Reserve after operation: Above 5 Minutes (Heat Run) Temperature : at 25 ºC ± 5 ºC Relative humidity : 65 % ± 10 % Input voltage : 220 V, 60 Hz
6) Adjustment equipments: Color Analyzer(CA-210 or CA-110),
DDC Adjustment Jig equipment, Factory SVC remocon.
7) Push the “IN STOP” key - For memory initialization.
3. Main PCB check process
* APC - After Manual-Insult, executing APC
* Boot file Download
1) Execute ISP program “Mstar ISP Utility” and then click
“Config” tab.
2) Set as below, and then click “Auto Detect” and check “OK”
message.
If “Error” is displayed, check connection between computer, jig, and set.
3) Click “Read” tab, and then load download file(XXXX.bin) by
clicking “Read”
4) Click “Connect” tab. If “Can’t” is displayed, check connection
between computer, jig, and set.
5) Click “Auto” tab and set as below.
6) Click “Run”.
7) After downloading, check “OK” message.
* USB DOWNLOAD
1) Put the USB Stick to the USB socket.
2) Automatically detecting update file in USB Stick.
- If your downloaded program version in USB Stick is Low, it didn’t work. But your downloaded version is High, USB data is automatically detecting.
3) Show the message “Copying files from memory”.
Pattern Generator (MSPG-925L or Equivalent),
Case1 : Software version up
1. After downloading S/W by USB, TV set will reboot automatically
2. Push “In-stop” key
3. Push “Power on” key
4. Function inspection
5. After function inspection, Push “In-stop” key.
Case2 : Function check at the assembly line
1. When TV set is entering on the assembly line, Push “In-stop” key at first.
2. Push “Power on” key for turning it on.
-> If you push “Power on” key, TV set will recover channel information by itself.
3. After function inspection, Push “In-stop” key.
filexxx.bin
(4)
(7) ……….OK
(5)
(6)
(1)
fil exxx.bin
(2)
(3)
Please Check the Speed : To use speed between from 200KHz to 400KHz
4) Updating is starting.
5) Uploading completed, the TV will restart automatically.
6) If your TV is turned on, check your updated version and Tool option.(explain the Tool option, next stage)
* If downloading version is more high than your TV have,
TV can lost al l chann el da ta . In this case,you have to channel recover. if all channel data is cleared, you didn’t have a DTV/ATV test on production line.
* After downloading, have to adjust Tool Option again.
1) Push "IN-START" key in service remote control.
2) Select “Tool Option 1” and push “OK” key.
3) Punch in the number. (Each model has their number)
4) Completed selecting Tool option.
3.1. ADC Process
(1) ADC
- Enter Service Mode by pushing “ADJ” key,
- Enter Internal ADC mode by pushing “ ” key at “6. ADC Calibration”
<Caution> Using ‘power on’ key of the Adjustment remote
control, power on TV.
* ADC Calibration Protocol (RS232)
Adjust Sequence
• aa 00 00 [Enter Adjust Mode]
• xb 00 40 [Component1 Input (480i)]
• ad 00 10 [Adjust 480i Comp1]
• xb 00 60 [RGB Input (1024*768)]
• ad 00 10 [Adjust 1024*768 RGB]
• aa 00 90 End Adjust mode
* Required equipment : Adjustment R/C.
3.2. Function Check
* Check display and sound.
- Check Input and Signal items. (cf. work instructions)
1) TV
2) AV (SCART1/SCART2/CVBS)
3) COMPONENT (480i)
4) RGB (PC : 1024 x 768 @ 60 Hz)
5) HDMI
6) PC Audio In
* Display and Sound check is executed by factory SVC remocon.
- 10 -
LGE Internal Use OnlyCopyright ©2011 LG Electronics. Inc. All rights reserved.
Only for training and service purposes
Module Tool option1 Tool option2 Tool option3 Tool option4 Tool option5
Item CMD1 CMD2 Data0
Adjust ‘Mode In’ A A 0 0 When transfer the ‘Mode In’,
Carry the command.
ADC Adjust A D 1 0 Automatically adjustment
(The use of a internal pattern)
ADC Calibration
ADC Comp 480i
ADC Comp 1080p
ADC RGB
NG
NG
NG
Reset
Start
EZ ADJUT
0. Tool Option1
1. Tool Option2
2. Tool Option3
3. Tool Option4
4. Tool Option5
5. Country Group
6. ADC Calibration
7. WHITE Balance
8. 10Point WB
9. Test Pattern
10. V-Com
11. Sub B/C
12. V-Com
13. P-Gamma
42LV4500
47LV4500
55LV4500
26496
34688
46976
19478
19478
19478
55337
55337
55337 14616)
14616
14616
8480
8480
8480
4. Total Assembly line process
4.1. Adjustment Preparation
· W/B Equipment condition CA210 : CCFL/EEFL -> CH9, Test signal: Inner pattern(80IRE)
LED -> CH14, Test signal: Inner pattern(80IRE)
· Above 5 minutes H/run in the inner pattern. (“power on” key
of adjust remote control)
· Edge LED W/B Table is process of time (Only LGD Module)
CA210: CH14, Test signal : Inner pattern(80IRE)
4.2. DDC EDID Write (RGB 128Byte )
• Connect D-sub Signal Cable to D-sub Jack.
Write EDID Data to EEPROM(24C0 gnisu) by2 DDC2 B
protocol.
• Check whether written EDID data is correct or not.
* For Service main Assembly, EDID have to be downloaded to
Insert Process in advance.
4.3. DDC EDID Write (HDMI 256Byte)
• Connect HDMI Signal Cable to HDMI Jack.
Write EDID Data to EEPROM(24C0 gnisu) by 2 DDC2B
protocol.
• Check whether written EDID data is correct or not.
* For Service main Assembly, EDID have to be downloaded to
Insert Process in advance.
- 11 -
LGE Internal Use OnlyCopyright ©2011 LG Electronics. Inc. All rights reserved.
Only for training and service purposes
Aging Time Cool Medium Warm
GP2R (Min.) X Y X Y X Y
269 273 285 293 313 329
1 0-2 279 288 295 308 319 338
2 3-5 278 286 294 306 318 336
3 6-9 277 285 293 305 317 335
4 10-19 276 283 292 303 316 333
5 20-35 274 280 290 300 314 330
6 36-49 272 277 288 297 312 327
7 50-79 271 275 287 295 311 325
8 80-149 270 274 286 294 310 324
9 Over 150 269 273 285 293 309 323
4.4. EDID DATA
1) All Data : HEXA Value
2) Changeable Data :
*: Serial No : Controlled / Data:01 **: Month : Controlled / Data:00 ***:Year : Controlled ****:Check sum
- Auto Download
• After enter Service Mode by pushing “ADJ” key,
• Enter EDID D/L mode.
• Enter “START” by pushing “OK” key.
* Caution : Never connect HDMI & D-sub Cable when EDID
download
* Edid data and Model option download (RS232)
EZ ADJUT
0. Tool Option1
1. Tool Option2
2. Tool Option3
3. Tool Option4
4. Tool Option5
5. Country Group
6. ADC Calibration
7. White Balance
8. 10 Point WB
9. Test Pattern
10. EDID D/L
11. P-Gamma
12. V-Com
13. P-Gamma
Item CMD1 CMD2 Data0
Download A A 0 0 When transfer the ‘Mode In’,
‘Mode In’ Carry the command.
Download A E 00 10 Automatically Download
(The use of a internal pattern)
EDID D/L
HDMI1 HDMI2 HDMI3 RGB
NG NG NG NG
Reset
Start
EDID D/L
Reset
Start
HDMI1 HDMI2 HDMI3 RGB
OK OK OK OK
D-sub to D-sub DVI-D to HDMI or HDMI to HDMI
For HDMI EDID
For Analog EDID
4.4. EDID DATA
1) All Data : HEXA Value
2) Changeable Data : *: Serial No : Controlled / Data:01 **: Month : Controlled / Data:00 ***:Year : Controlled ****:Check sum
- Auto Download
• After enter Service Mode by pushing “ADJ” key
• Enter EDID D/L mode.
• Enter “START” by pushing “OK” key.
- 12 -
LGE Internal Use OnlyCopyright ©2011 LG Electronics. Inc. All rights reserved.
Only for training and service purposes
4.6 Internal pressure
Confirm whether is normal or not when between power board's ac block and GND is impacted on
1.5kV(dc) or 2.2kV(dc) for one second.
4.7. 3D Function test
(Pattern Generator MSHG-600 or MSPG-6100 HDMI
1.4 Supported Equipment , HDMI mode No. 872 , pattern No. 83)
2) After automatically display 3D OSD, push the OK Key.
3) Check the pattern such as in the following Fig2 without having to wear glasses.
4.5 Outgoing condition Configuration
Push ‘IN STOP’ key, then in-stop processing will start. If processing is complete, TV will turn off automatically. *Must not AC power OFF during processing.
1) Input 3D test pattern. (HDMI mode No. 872, Pattern No. 83)
Loading...
+ 25 hidden pages