LevelOne IES-0823 User Manual

Page 1
User Manual
IES-0823
6 GE + 2 SFP Unmanaged Switc h -20 to 60C , DIN-rail
Page 2

Preface

A member of the growing family of rugged switches, this switch addresses a need for a smaller switch. This switch provides an affordable solution for rugged and outdoor environment, transportation road-side cabinet, industrial floor shop, multitenant dwellings or Fiber To The Home (FTTH) applications. Capable of operating at temperature
extremes of -20°C to +60°C, this is the switch of choice for harsh environments constrained by space.
Plug-and-Play Solution: The switch is a plug-and-play Gigabit Ethernet Switch in compact size. It doesn't have any complicated software to set up.
This manual desc r ibes how to install and use the Industrial Gigabit Ethernet Switch. This switch integrates full wire speed switching technology. This switch brings the answer to complicated Industrial networking environments.
To get the most out of this manual, you should have an understanding of Ethernet networking concepts.
In this manual, you will find:
Features on the switch
Illustrative LED functions
Installation instructions
Specifications
IES-0823 User Manual Page 2
Page 3
Table of Contents
PREFACE ........................................................................................................................................................... 2
PRODUCT OVERVIEW ....................................................................................................................................... 4
INDUSTRIAL GIGABIT ETHERNET SWITCH ...................................................................................................................... 4
PACKAGE CONTENTS ................................................................................................................................................ 4
PRODUCT HIGHLIGHTS ............................................................................................................................................. 5
FRONT PANEL DISPLAY ............................................................................................................................................. 6
PHYSICAL PORTS ..................................................................................................................................................... 6
INSTALLATION .................................................................................................................................................. 7
SELECTING A SITE FOR THE SWITCH ............................................................................................................................. 7
DIN RAIL MOUNTING .............................................................................................................................................. 8
WIRING DIAGRAM .................................................................................................................................................. 9
CONNECTING TO POWER ........................................................................................................................................ 10
CONNECTING TO YOUR NETWORK ............................................................................................................................ 12
SPECIFICATIONS ............................................................................................................................................. 13
APPENDIX A – CONNECTOR PINOUTS ............................................................................................................ 14
IES-0823 User Manual Page 3
Page 4

Product Overview

Industrial Gi gab it Ethernet Switch

Package Contents

When you unpack the product package, you shall find the items listed below. Please inspect the contents, and report any apparent damage or missing items immediately to your authorized reseller.
IES-0823 6 GE + 2 SFP Unmanaged Switch -20 to 60C, DIN-rail
Quick Installation Guide
CD User Manual
IES-0823 User Manual Page 4
Page 5

Product Highlights

Basic Features

Meets EN61000-6-2 & EN61000-6-3 EMC Generic Standard Immunity for industrial environment.
Supports IEEE802.3/802.3u/802.3ab/802.3z/802.3x.
1000Mbps-Full-duplex, 10/100Mbps-Full/Half-duplex.
Auto-Negotiation, Auto MDI/MDIX.
1000Base-SX/LX: Multi mode, Single mode SC type. 1000Base-BX: WDM Single mode
SC type.
IEEE802.1p Queue Supports 4 priority queues.
8192 MAC addresses.
1.125M bits buffer memory.
Full wire-speed forwarding rate.
Supports jumbo frame up to 9K Bytes.
Alarms for power failure by relay output.
Power Supplies: Redundant 9-32VDC Terminal Block power inputs and 12VDC DC JACK
with 100-240VAC external power supply.
Field Wiring T erminal: Use Copper Conductors Only, 60/75, 12-24 AWG torque value 7 lb-in.
Operating voltage and Max. current consumption: 0.6A @ 12VDC, 0.3A @ 24VDC.
Power consumption: 7.2W Max.
-20 to 60 operating temperature.
Industrial aluminum case.
Supports DIN-Rail or Panel Mounting installation.
IES-0823 User Manual Page 5
Page 6

Front Panel Display

Power Status (PW1, PW2, PW3)

These LEDs come on when the switch is properly connected to power and turned on.

Port Status LEDs

The LEDs display status for each respe ctive port.

LED State Indication 10/100Base-TX
LNK/ACT
(Green)
1000Base-T/SX/LX/BX
LNK/ACT
(Orange)
Steady A valid network connection established.
Flashing
Steady A valid network connection established. Flashing
Transmitting or receiving da ta. ACT stands for ACTIVITY.
Transmitting or receiving da ta. ACT stands for ACTIVITY.

Physical Ports

This switch provides:
Eight 10/100/1000Base-TX ports Seven 10/100/1000Base-TX por ts + one combo port Six 10/100/1000Base-TX ports + two combo ports
<Note> Combo port: Either 1000Base-SX/LX port or 10/100/1000Base-TX port. Connectivity
RJ-45 connectors SC connector on 1000Base-SX/LX/BX fiber port
IES-0823 User Manual Page 6
Page 7

Installation

This chapter gives step-by-step instructions about how to install the switch:

Selecting a Site for the Switch

As with any electric device, you should place the switch where it will not be subjected to extreme temperatures, humidity, or electromagnetic interference. Specifically, the site you select should meet the following requirements:
The ambient temperature should be between -20 to 60 degrees Celsius.
The relative humidity should be less than 95 percent, non-condensing.
Surrounding electrical devices should not exceed the electromagnetic field (RFC)
standards.
Make sure that the switch receives adequate ventilation. Do not block the ventilation holes on the switch
The power outlet should be within 1.8 meters of the switch.
IES-0823 User Manual Page 7
Page 8

DIN Rail Mounting

Fix the DIN rail attachment plate to the back panel of the switch. Installation: Place the switch on the DIN rail from above using the slot. Push the front of
the switch toward the mounting surface until it audibly snaps into place. Removal: Pull out the lower edge and then remove the switch from the DIN rail.
IES-0823 User Manual Page 8
Page 9

Wiring Diagram

IES-0823 User Manual Page 9
Page 10

Connecting to Power

Redundant DC Terminal Block Power Inputs

There are two pairs of power inputs can be used to power up this device. You only need to have one power input connected to run the switch.
Step 1: Connect the DC power cord to the plug-able terminal block on the switch, and then plug it into a standard DC outlet.
Step 2: Disconnect the power cord if you want to shut down the switch.

12VDC DC Jack

Step 1: Connect the supplied AC to DC power adapter to the receptacle on the topside of the switch.
Step 2: Connect the power cord to the AC to DC power adapter and attach the plug into a standard AC outlet with the appropriate AC voltage.
IES-0823 User Manual Page 10
Page 11

Alarms for Power Failure

Step 1: There are two pins on the terminal block are used for power failure detection. It provides the normally closed output when the power source is active. Use this as a dry contact application to send a signal for power failure detection.
Power Input Assignment Power3 12VDC ,3A DC Jack
Power2
Power1
Relay Output Rating 30 VDC, 1A Relay Alarm Assignment
FAULT
Special note: The relay output is normal open position when there is no power to the switch. Please do not connect any power source to this terminal to prevent the shortage to your power supply.
1.5A@24VDC(9-32VDC)
Power Ground
1.5A@24VDC(9-32VDC)
Power Ground Earth Ground
*Warning signal disable for following: The relay contact closes if Power1 and Power2 are both failed but Power3 on. The relay contact closes if Power3 is failed but Power1 and Power2 are both on.
Terminal Block
IES-0823 User Manual Page 11
Page 12

Connecting to Your Network

Cable Type & Length

It is necessary to follow the cable specifications below when connecting the switch to your network. Use appropriate cables that meet your speed and cabling requirements.
Cable Specifications
Speed Connector Port Speed
Half/Full Duplex
10Base-T RJ-45 10/20 Mbps 2-pair UTP/STP Cat. 3, 4, 5 100 m 100Base-TX RJ-45 100/200 Mbps 2-pair UTP/STP Cat. 5 100 m 1000Base-T RJ-45 2000 Mbps 4-pair UTP/STP Cat. 5, 5e 100 m 1000Base-SX SC 2000 Mbps MMF (50 or 62.5μm) 550 m 1000Base-LX SC 2000 Mbps SMF (9 or 10μm) 10, 20, or 50 km 1000Base-BX SC 2000 Mbps SMF (9 or 10μm) 20 km

Cabling

Cable Max.
Distance
Step 1: First, ensure the power of the switch and end devices are turned off. <Note> Always ensure that the power is off before any installation. Step 2: Prepare cable with corresponding connectors for each type of port in use. <Note> To connect two regular RJ-45 ports between switches or hubs, you need a
straight or cross-over cable. Step 3: Consult the previous section for cabling requirements based on connectors and
speed. Step 4: Connect one end of the cable to the switch and the other end to a desired
device. Step 5: Once the connections between two end devices are made successfully, turn on
the power and the switch is operational.
IES-0823 User Manual Page 12
Page 13

Specifications

Forwarding Rate

Performance

148,80pps for 10Mbps

Cable

Operating V oltage &
EMI
EMS

Industrial Gigabit Ethernet Switch

Applicable Standards IEEE802.3 10Base-T

Switching Method

10Base-T: 100Base-TX: 1000Base-T: 1000Base-SX/LX/BX:
10Base-T: 100Base-TX: 1000Base-T:
1000Base-SX/LX/BX:
LED Indicators
Dimensions
Net Weight
Power T erm inal Blo ck: 9-32VDC
Max. Current Consumption Power Consumption Operating Temperature Storage T empera ture Humidity Safety
Environmental Test Compliance
IES-0823 User Manual Page 13
10/100/1000Base-TX auto-negotiating ports with RJ-45 connectors 1000Base-SX/LX/BX fiber ports
IEEE802.3u 100Bas e-TX IEEE802.3ab 1000Base-T IEEE802.3z 1000Base-SX/LX
Store-and-Forward
10 / 20Mbps Half / Full-duplex 100 / 200Mbps Half / Full-duplex 2000Mbps Full-duplex 2000Mbps Full-duplex
148,810pps for 100Mbps 1,488,100pps for 1000Mbps
2-pair UTP/STP Cat. 3, 4, 5 2-pair UTP/STP Cat. 5 4-pair UTP/STP Cat. 5, 5e Up to 100m (328ft) MMF (50 or 62.5μm), SMF (9 or10μm)
Per unit –
Power status (Power1, Power2, Power3)
Per port –
10/100Base-TX - Link/ACT (Green) 10/100/1000Base-TX or 1000Base-SX/LX/BX - Link/ACT (Orange)
58mm (W) × 110mm (D) × 135mm (H) (2.29” (W) × 4.33” (D) × 5.31” (H))
0.8Kg (1.76lbs.)
DC Jack: 12VDC, External AC/DC required
0.6A @ 12VDC, 0.3A @ 24VDC
7.2W Max.
-20℃ to 60℃ (-4℉ to 140℉)
-40℃ to 85℃ (-40℉ to 185℉) 5%-95% non-condensing UL508 FCC Part 15, Class A
EN61000-6-3: EN55022, EN61000-3-2, EN61000-3-3
EN61000-6-2: EN61000-4-2 (ESD Standard) EN61000-4-3 (Radiated RFI Standards) EN61000-4-4 (Burst Standards) EN61000-4-5 (Surge Stan dards) EN61000-4-6 (Induced RFI Standards) EN61000-4-8 (Magnetic Field Standards)
IEC60068-2-6 Fc (Vibration Resistance) IEC60068-2-27 Ea (Shock) IEC60068-2-32 Ed (Free Fall)
Page 14

Appendix A – Connector Pinouts

Pin arrangement of RJ-45 connectors:
RJ-45 Connector and Cable Pi ns
The following table lists the pinout of 10/100/1000Base-TX ports.
Pin
1 TP0 2 TP0 3 TP1 4 TP2 5 TP2 6 TP1 7 TP3 8 TP3
Ports
IES-0823 User Manual Page 14
Loading...