Leuze GSX14E, GSU14E, IGSU14E, IGSU14E SD Operating Instructions

IO-Link interface description
GSX14E, GSU14E, IGSU14E, IGSU14E SD
Ultrasonic fork sensor
We reserve the right to make technical changes
EN • 2020-07-08 • 50144571
© 2020 Leuze electronic GmbH + Co. KG
Leuze electronic GmbH + Co. KG GSX14E, GSU14E, IGSU14E, IGSU14E SD 2
1 IO-Link interface....................................................................................................4
1.1 IO-Link identification ...............................................................................................................4
1.2 IO-Link process data............................................................................................................... 4
1.3 Device-specific IODD.............................................................................................................. 5
1.4 IO-Link parameters documentation ........................................................................................ 5
2 Functions configurable via IO-Link.....................................................................6
3 Recipe management ...........................................................................................15
Table of contents
Leuze electronic GmbH + Co. KG GSX14E, GSU14E, IGSU14E, IGSU14E SD 3
IO-Link interface
1 IO-Link interface
Sensors in the GSX14E/…, IGSU14E/…, IGSU14E/..SD.. and GSU14E/… variant have a dual channel ar­chitecture. Available on pin4 is the IO-Link interface in accordance with specification 1.1.2 (July 2013) with support of Smart Sensor Profile 1.0 (March 2017) with profile type SSP2.6. You can easily, quickly and economically configure the devices via the IO-Link interface. Furthermore, the sensor transmits the process data via the IO-Link interface and makes diagnostic information available through it.
In parallel with the IO-Link communication, the sensor can output the continuous switching signal for object detection on pin2 (SSC1 by default) by means of the dual channel architecture. The IO-Link communica­tion does not interrupt this signal.
1.1 IO-Link identification
VendorID dec/hex DeviceID dec/hex Device
338/0x152 2500/0x0009C4 GSX14E/LWT.3-M12
GSX14E/LWT.3-M12V
2501/0x0009C5 GSX14E/1WT.3-M12
GSX14E/1WT.3-M12V
2502/0x0009C6 GSX14E/LGT.3-M12
2510/0x0009CE IGSU14E/LWT.3-M12
IGSU14E/LWT.3-M12V
Please refer to the respective product data sheet for the identification data of other IO-Link devices.
1.2 IO-Link process data
Device input data (PDout)
Data bit Assignment Meaning
0 Deactivation 0: transmitter active
1 Not assigned Free
2 Not assigned Free
3 Not assigned Free
2511/0x0009CF IGSU14E/1WT.3-M12
IGSU14E/1WT.3-M12V
2512/0x0009D0 IGSU14E/LWT.3SD-M12
2520/0x0009D8 GSU14E/LGT.3-M12
GSU14E/LGT.3-M12V
2521/0x0009D9 GSU14E/16T.3-M12
GSU14E/16T.3-M12V
1: transmitter not active
4 Not assigned Free
5 Not assigned Free
6 Not assigned Free
7 Not assigned Free
Leuze electronic GmbH + Co. KG GSX14E, GSU14E, IGSU14E, IGSU14E SD 4
IO-Link interface
Device output data (PDin)
Data bit Assignment Meaning Present in de-
vice
0 Switching signal
SSC1
1 Not assigned Free
2 Not assigned Free
3 Sensor operation Sensor operation off when detection is not possi-
4 Measurement value Measurement value that indicates whether device
5 Warning Warning output
6 Teach-in method 0: Teach process not ended (or not yet started)
0: not active 1: active
ble (e.g if deactivated or during the teach event)
0: off 1: on
functionality is present
0: No valid measurement value 1: Measurement value available
0: no warning 1: warning
1: Teach process ended
GSX14E/.. IGSU14E/.. IGSU14E/..SD.. GSU14E/..
GSX14E/.. IGSU14E/.. IGSU14E/..SD.. GSU14E/..
GSX14E/.. IGSU14E/.. IGSU14E/..SD.. GSU14E/..
GSX14E/.. IGSU14E/.. IGSU14E/..SD.. GSU14E/..
GSX14E/.. IGSU14E/.. IGSU14E/..SD.. GSU14E/..
7 ALC function (Auto-
Level-Control: auto­matic optimization of the switching thresh­old)
0: ALC function not active 1: ALC function active
1.3 Device-specific IODD
At www.leuze.com in the download area for IO-Link sensors you will find the IODD zip file with all data re­quired for the installation.
On the IODDfinder platform (https://ioddfinder.io-link.com/#/), a central cross-manufacturer database, you can also find the description files (IODDs) of the IO-Link sensors.
1.4 IO-Link parameters documentation
The complete description of the IO-Link parameters can be found in the *.html files. Double-click on a lan­guage variant:
• German: *IODD*-de.html
• English: *IODD*-en.html
GSX14E/.. IGSU14E/..
Leuze electronic GmbH + Co. KG GSX14E, GSU14E, IGSU14E, IGSU14E SD 5
Loading...
+ 10 hidden pages