Scanning range
Adjustment range25 … 400mm150 … 1300mm
Ultrasonic frequency310kHz200kHz
Typ. opening angle9°16°
Resolution switching output0.5mm1mm
Direction of beamaxialaxial
Reproducibility± 0.15% of end value
Switching hysteresis5mm 1) 10mm
Temperature drift0.17%/K0.17%/K
Timing
Switching frequency7Hz8 Hz
Response time71ms62ms
Delay before start-up < 300ms< 300 ms
Electrical data
Operating voltage U
Residual ripple± 10% of U
Open-circuit current≤ 50mA
Switching output2x PNP transistor
Function2 x NO contact, reversible
Output currentmax. 150mA
Switching range adjustmentteach-in (pin 2):
Changeover NO/NCteach-in (pin 2):
Indicators
Yellow LED OUT1: object detected
Yellow LED, flashingteach-in / teaching error
Green LED object within the scanning range
Mechanical data
Housing all metal - brass, nickel-plated
Weight 50g
Ultrasonic transducerpiezoceramic
Connection type M 12 connector, 5-pin
Fitting positionany
Environmental data
Ambient temp. (operation/storage) -25°C … +70°C/-30°C … +85°C
Protective circuit
VDE safety classIII
Degree of protection IP 67 and IP 68
Standards appliedEN 60947-5-2
CertificationsUL 508, C22.2 No.14-13
1) At 20°C
2) Target: 20mm x 20mm plate
3) Target: 100mm x 100 mm plate
4) For UL applications: for use in class 2 circuits according to NEC only
5) The ceramic material of the ultrasonic transducer contains lead zirconium titanate (PZT)
6) 1=short-circuit and overload protection, 2=polarity reversal protection, 3=wire break and inductive protection
7) These proximity switches shall be used with UL Listed Cable assemblies rated 30V, 0.5 A min,
in the field installation, or equivalent (categories: CYJV/CYJV7 or PVVA/PVVA7)
8) Ambient temperature 85°C. Use same voltage supply for all circuits.
1)
4)
B
25 … 400mm
15… 30V DC (incl. ± 10% residual ripple)
2)
B
150 … 1300mm
1)
± 0.15% of end value 1)
1)
3)
for OUT1: connect to GND for 2 … 7s
for OUT2: connect to GND for 7 … 12s
for OUT1: connect to U
for OUT2: connect to U
5)
6)
1, 2, 3
for 2 … 7s
B
for 7 … 12s
B
4) 7) 8)
Diagrams
HTU418B-400.W/…-M12
150
100
50
0
-50
-100
-150
0100 200 300 400 500
HTU418B-1300.W/…-M12
300
200
100
0
-100
-200
-300
0 200 400 600 800 1000 1200 1400
300
200
100
0
-100
-200
-300
0 200 400 600 800 1000 1200 1400
300
200
100
0
-100
-200
-300
0 200 400 600 800 1000 1200 1400
y2
y1
y2
y1
y2
y1
y2
y1
Remarks
Operate in accordance with intended use!
This product is not a safety sensor and is not intended as personnel protection.
The product may only be put into operation by competent persons.
Only use the product in accordance with the intended use.
HTU418B-…W/4T4-M12 - 032017/02
HTU418B…WUltrasonic sensors, angled 90° with 2 switching outputs
Part number code
HTU418B-1300 .W/4T4-M12
Operating principle
HTUUltrasonic sensor, scanning principle, with background suppression
Series
418B418B Series, cylindrical M18 construction
Scanning range in mm
40025 … 400
1300150 … 1300
Equipment (optional)
WDesign with angle head of 90°
Pin assignment of connector pin 4 / black cable wire (OUT1)
4PNP output, NO contact preset
PPNP output, NC contact preset
2NPN output, NO contact preset
NNPN output, NC contact preset
Pin assignment of connector pin 2 / white cable wire (Teach-IN)
TTeach input
All settings on the sensor are taught-in via the Teach-IN input. Device status and switching states are indicated as follows by
means of a yellow and green LED:
Switching behavior NO contactSwitching behavior NC contact
Notice!
In measurement operation, the yellow and green LED only indicate the behavior of output OUT1.
The behavior of output OUT2 is not indicated.
Adjusting the switching points via the teach input
The switching points of the sensor outputs OUT1/OUT2 are set to 400mm or 1000mm on delivery.
By means of a simple teach event, the two switching points can be individually taught to an arbitrary distance within the scanning
range. The Leuze PA1/XTSX-M12 teach adapter can be used for this purpose. The adapter can also be used to easily switch the
output function from NO contact to NC contact.
1-point teach of output OUT11-point teach of output OUT2
1. Place object at desired switching distance.1. Place object at desired switching distance.
2. For the adjustment of OUT1, connect input Teach-IN to GND for 2…7s
(Leuze teach adapter: position "Teach-GND").
The current state of output OUT1 is frozen during the teach event.
3. The yellow LED flashes at 3Hzand is then ON.
The current object distance has been taught as the new switching point.
4. Error-free teach: switching behavior according to the diagram shown
above.
Faulty teach (object may be too close or too far away – please note scanning range):
yellow LED flashes at 5Hz until an error-free teach event is performed.
Output OUT1 is inactive as long as there is a teach error.
2. For the adjustment of output OUT2, connect input Teach-IN to GND for
7 … 12s (Leuze teach adapter: position "Teach-GND"). The current state of output OUT2 is frozen during the teach event.
3. The yellow LED flashes at 3Hz.
The current object distance has been taught as the new switching point.
4. Error-free teach: switching behavior according to the diagram shown
above.
Faulty teach (object may be too close or too far away – please note scanning range):
yellow LED flashes at 5Hz until an error-free teach event is performed.
Output OUT2 is inactive as long as there is a teach error.
Adjusting the switching function (NC/NO) via the teach input
The switching function of both sensor outputs is set to normally open (NO) on delivery.
If the switching function is changed, the switching output is changed to the opposite state (toggled).
Changeover of the switching function of output OUT1Changeover of the switching function of output OUT2
1. To change the switching function, connect input Teach-IN to UB for
2…7s (Leuze teach adapter: position "Teach-UB").
The current state of output OUT1 is frozen while the adjustment is made.
2. The green and yellow LEDs flash alternately at 2Hz.
The switching function was changed over.
The switching behavior corresponds to the diagram shown above.
Notice!
Please note that the switching point is taught when GND is connected and the output function is reversed when
is connected. If no sensor action is desired, pin 2 must remain unconnected!
U
B
1. To change the switching function, connect input Teach-IN to UB for
7 … 12s (Leuze teach adapter: position "Teach-UB).
The current state of output OUT2 is frozen while the adjustment is made.
2. The green and yellow LEDs flash alternately at 5Hz.
The switching function was changed over.
The switching behavior corresponds to the diagram shown above.
HTU418B-…W/4T4-M12 - 032017/02
Loading...