Operating voltage U
Residual ripple± 7% of U
Open-circuit current≤ 50mA
Switching output / Function…/4P… 2 independent PNP transistor switching outputs
Output currentMax. 100 mA
Switching range adjustment1-point teach: teach-in button 2 … 7s,
Changeover
NO/NC
Indicators
Yellow LED OUT1: object detected
Blue LED OUT2: object detected
Flashing yellow or blue LEDTeach-in
Flashing green and yellow/blue LEDsTeaching error
Green LED Object within the scanning range
5) For UL applications: use is permitted exclusively in Class 2 circuits according to NEC
6) The ceramic material of the ultrasonic transducer contains lead zirconium titanate (PZT)
7) 1=short-circuit and overload protection, 2=polarity reversal protection, 3=wire break and inductive protection
8) These proximity switches shall be used with UL Listed Cable assemblies rated 30V, 0.5 A min,
in the field installation, or equivalent (categories: CYJV/CYJV7 or PVVA/PVVA7)
HTU318…W90° angled ultrasonic sensors with 2 switching outputs
Adjusting the switching points via the teach button
The switching points of the sensor for both outputs are set to 400 mm or 1600mm (static 1-point teach) on delivery.
By means of a simple operating procedure, the switching points for each output can be individually taught to an arbitrary distance within
the scanning range with 1-point teach (static) or 2-point window-teach (static).
Moreover, the output function can be switched from NO contact (NO - normally open) to NC contact (NC - normally closed). An LED is
permanently assigned to each output for the setting.
Selecting the output that is to be taught: OUT1 or OUT2
1.Press the teach button for ≥2s to activate teach mode. The yellow LED (OUT 1) flashes at 1Hz. While in this state, output OUT 1 can be taught.
2.To teach output OUT 2, briefly press the teach button again. The blue LED (OUT 2) now flashes at 1Hz. While in this state, output OUT 2 can be taught.
3.Briefly press the teach button again to toggle between outputs OUT 1 and OUT 2 in this state. The flashing LED indicates which
output is ready for teaching:
yellow LED flashing = OUT 1 ready for teaching,
blue LED flashing = OUT 2 ready for teaching.
Teaching output OUT 1 or OUT 2
First activate the previously described teach mode for output OUT 1 or OUT 2.
1. Place object at desired switching distance.1. First, place object at desired switching distance for switching point 1.
2. To adjust the selected output, press the teach button for 2…7s until
the yellow LED (OUT 1) or blue LED (OUT 2) flashes at 3Hz.
The current state of the selected output is frozen during the adjustment
process.
3. Release the button.
The current object distance has been taught as the new switching point.
4. Error-free teach: LED states and switching behavior according to the
diagram shown above.
Faulty teach (object may be too close or too far away – please note scanning range):
green and yellow (blue) LEDs flash at 8Hz until an error-free teach
event is performed.
The selected output is inactive as long as there is a teaching error.
1) See table "Switching behavior with 2-point window-teach as a function of the switching function"
2. To adjust the selected output, press the teach button for 7 … 12s until
the yellow (blue) and green LEDs flash alternately at 3Hz.
3. Release the button. The sensor remains in teach mode and the LEDs
continue to flash.
4. Then, place the object at the desired switching distance for switching
point 2.
Note:The minimum distance between the switching points is a s fo llo ws:
5. Briefly press the teach button again to complete the teach event.
The switching window for the selected output was taught in.
6. Error-free teach: LED states and switching behavior according to the
diagram shown above.
Faulty teach (object may be too close or too far away – please note scanning range):
green and yellow (blue) LEDs flash at 8Hz until an error-free teach
event is performed.
scanning range of 400 mm:40mm
scanning range of 1600mm:160mm
Adjusting the switching function (NC/NO) via the teach button
The switching function of the sensor is preset as follows on delivery:
OUT 1: NO contact
OUT 2: NC contact
The output function for each output can be individually switched from NO contact (NO - normally open) to NC contact (NC - normally
closed) and vice versa. If the switching function is changed, the switching output is changed to the opposite state (toggled).
First activate the previously described teach mode for output OUT 1 or OUT 2.
Changeover of the switching function
1. To change the switching function of the selected output, press the teach button for longer than 12s.
The current state of the selected output is frozen during the adjustment process.
2. The green and yellow (blue) LEDs flash alternately at 3Hz.
If the yellow (blue) LED is ON afterwards, the selected output operates as an NO contact.
If the yellow (blue) LED is OFF afterwards, the selected output operates as an NC contact.
Please make certain that the wiring is performed according to the connection diagram.
Sync/MUX pin 5 on all sensors in the network must be connected to one another. Generation
of the synchronization signal for all sensors in the network occurs automatically.
HTU318…W90° angled ultrasonic sensors with 2 switching outputs
Synchronization of multiple HTU318 ultrasonic sensors
If adjacent ultrasonic sensors receive the signals of other sensors, so-called crosstalk occurs, which leads to faulty measurement results.
Through temporal synchronization of the adjacent sensors, this can be avoided. Via the Sync/MUX input, the HTU318 ultrasonic sensors
can be synchronized in 2 different ways:
Synchronous operation
In this operating mode the mutual interference of adjacent sensors can be avoided. For this purpose, up to 6 sensors of the same type
are wired together in a network according to the following diagram.
The devices work in synchronous operation with a simultaneous transmission pulse. The response time of the individual sensors in
the network corresponds approximately to that of a single sensor. However, an additional delay time of approx. 20 ms occurs in
comparison to the specified response time in standard operation.
Please make certain that the wiring is performed according to the connection diagram.
Sync/MUX pin 5 on all sensors in the network must be connected to one another.
To activate multiplex operation, the Sync/MUX cable must be connected to GND for 5 s when applying the operating voltage.
Generation of the multiplex signal for all sensors in the network occurs automatically.
Activating multiplex operation:
to GND for 5s during power-on.
HTU318…W
Multiplex operation
In this operating mode the mutual interference of adjacent sensors can be reliably avoided. For this purpose, up to 4 sensors of the same
type are wired together in a network according to the following diagram.
The devices operate in multiplex operation with a cyclically time-delayed transmission pulse and are switched to a passive state outside of the active phase, whereby the states of the outputs are frozen until the next active phase. The response time of the individual
sensor in the network is therefore extended with respect to the response time of a single sensor as follows:
Response time in the network = (Response time of sensor * n) + 25ms (n = number of sensors in the network)
Multiplex operation wiring schematic
Resetting to factory settings
The sensor can be reset to the factory setting (1 switching point each at 400 mm or 1600 mm).
Resetting to factory settings
1. When switching on the supply voltage (during power-on), press the teach button for >5s.
2. Release the button. The green, yellow and blue LEDs flash alternately and very quickly for a brief time.
The sensor was reset to the factory setting:
switching output OUT 1: NO contact, 1 switching point at 400 mm or 1600 mm (static 1-point teach),
switching output OUT 2: NC contact, 1 switching point at 400 mm or 1600 mm (static 1-point teach).