5) For UL applications: use is permitted exclusively in Class 2 circuits according to NEC
6) The ceramic material of the ultrasonic transducer contains lead zirconium titanate (PZT)
7) 1=short-circuit and overload protection, 2=polarity reversal protection, 3=wire break and inductive protection
8) These proximity switches shall be used with UL Listed Cable assemblies rated 30V, 0.5 A min,
in the field installation, or equivalent (categories: CYJV/CYJV7 or PVVA/PVVA7)
1)
5)
B
7)
40 … 300mm 2)
1) 3)
4)
10 … 30V DC (incl. ± 5% residual ripple)
B
1 PNP transistor switching output
…/2…
1 NPN transistor switching output
2-point teach: teach-in (pin 2) 7 … 12s to U
Teach-in (pin 2) > 12s to UB
All settings on the sensor are taught-in via the Teach-IN input. Device status and switching states are indicated as follows by
means of a LED:
Switching behavior
1-point teach (1 switching point)
Switching behavior NO contactSwitching behavior NC contact
2-point window-teach (2 switching points)
Switching behavior NO contactSwitching behavior NC contact
Note!
The switching behavior is not defined in the dead zone.
Switching behavior with 2-point window-teach as a function of the switching function
Switching function
configured as
NO (normally open)
NC (normally closed)
HTU318-300…-M12 - 012017/02
HTU318-1200…-M12 - 01
First taught object
distance
Second taught object
distance
FarClose
CloseFar
FarClose
CloseFar
Output switching behavior
HTU318Ultrasonic sensors with 1 switching output
Adjusting the switching point via the teach input
The switching point of the sensor is set to 300mm or 1200 mm on delivery.
By means of a simple teach event, the switching points can be individually taught to an arbitrary distance within the scanning
range with 1-point teach (static) or 2-point window-teach (static). The Leuze PA1/XTSX-M12 Teach Adapter can be used for this
purpose. The adapter can also be used to easily switch the output function from NO contact to NC contact.
1. Place object at desired switching distance.1. First, place object at desired switching distance for switching point 1.
2. To adjust output OUT1, connect the Teach-IN input to U
(Leuze Teach Adapter: position "Teach-UB").
The current state of output OUT1 is frozen while the adjustment is made.
3. The yellow LED flashes at 3Hz and is then ON.
The current object distance has been taught as the new switching point.
4. Error-free teach: LED states and switching behavior according to the diagram shown above.
Faulty teach (object may be too close or too far away – please note scanning range):
green and yellow LEDs flash at 8Hz until an error-free teach event is
performed.
The output OUT1 is inactive as long as there is a teaching error.
for 2…7s
B
2. To adjust output OUT1, connect the Teach-IN input to UB for 7…12s
(Leuze Teach Adapter: position "Teach-UB") until the yellow and green
LEDs flash alternately at 3Hz.
3. Release the button. The sensor remains in teach mode and the LEDs
continue to flash.
4. Then, place the object at the desired switching distance for switching
point 2.
Note:The minimum distance between the switching points is a s fo llo ws:
5. To complete the teach event, briefly connect the Teach-IN input to UB
again (Leuze Teach Adapter: position "Teach-UB").
The switching window was taught in.
6. Error-free teach: LED states and switching behavior according to the
diagram shown above.
Faulty teach (object may be too close or too far away – please note scanning range):
green and yellow LEDs flash at 8Hz until an error-free teach event is
performed.
scanning range of 400 mm:40mm
scanning range of 1200mm:120mm
Adjusting the switching function (NC/NO) via the teach input
The switching function of the sensor is preset as follows on delivery:
OUT 1: NO contact
The output function can be switched from NO contact (NO - normally open) to NC contact (NC - normally closed) and vice versa.
Leuze Teach Adapter PA1/XTSX-M12 can be used for this purpose. If the switching function is changed, the switching output is
changed to the opposite state (toggled).
Changeover of the switching function
1. To change the switching function, connect the Teach-IN input to UB for more than 12s (Leuze Teach Adapter: position "Teach-UB").
The current state of output OUT1 is frozen while the adjustment is made.
2. The green and yellow LEDs flash alternately at 2Hz.
The switching function was changed over.
The switching behavior corresponds to the diagram shown above.
Resetting to factory settings
The sensor can be reset to the factory setting (one switching point at 300 mm or 1200 mm).
Leuze Teach Adapter PA1/XTSX-M12 can be used for this purpose.
Resetting to factory settings
1. When switching on the supply voltage (during Power-On), connect the Teach-IN input to UB for > 5s (Leuze Teach Adapter position "Teach-UB").
The green and yellow LEDs flash alternately and very quickly for a brief time.
2. Disconnect the Teach-IN input from U
1 switching point at 300 mm or 1200 mm (1-point teach, static).
. The sensor was reset to the factory setting:
B
HTU318-300…-M12 - 012017/02
HTU318-1200…-M12 - 01