Leuze GSU 710/66 Data Sheet

IP 40
IEC 68...
IEC 801...
GSU 710/66 Double Sheet Testing Unit
Dimensioned drawing
en 05-2014/06 50108368-01
Reliable detection of multi-layer paper and
plastic sheets and metal foils
Measurement range from 20g/m2 paper to
800g/m
2
cardboard
Plug connectionOperating state indicators via light-emitting
diodes
Push-pull switching outputs
Accessories:
(available separately)
M12 connectors (KD …)Ready-made cables (K-D …)
A Through hole B Minimum intrusion depth of sheet edge C Inlay nut M4 possible D Red indicator diode E Yellow indicator diode
Electrical connection
We reserve the right to make changes • DS_GSU71066_en_50108368_01.fm
Leuze electronic GmbH + Co. KG In der Braike 1 D-73277 Owen Tel. +49 (0) 7021 573-0
• www.leuze.com
GSU 710/66 - 05
GSU 710/66
Specifications
Physical data
Mouth width 13mm Mouth depth 89mm Minimum intrusion depth 31mm Converter frequency approx. 330kHz
Timing
Switching frequency 200Hz Response time 5ms Delay before start-up 300ms acc. to IEC 60947-5-2
Electrical data
Operating voltage UB 18 … 30VDC (incl. residual ripple) Residual ripple 15% of U Open-circuit current ≤ 50mA Switching outputs 2 push-pull switching outputs Function characteristics single sheet detected, or 1 sheet
Signal voltage high/low ≥ (U Output current max. 100mA per output
double sheet detected, or 2 sheets
Indicators
Yellow LED single sheet detected Red LED double sheet detected
Mechanical data
Housing plastic Color red Weight approx. 100g Connection type M12 connector, 5-pin, or
cable 400mm with M 12 connector, 5-pin
Environmental data
Ambient temp. (operation/storage) 0°C … +50°C/-40°C … +70 °C Protective circuit VDE safety class II, all-insulated Protection class IP 40 Standards applied IEC 60947-5-2
2)
1, 2, 3
Options
Teach-in input
Teach-in input resistance R Teach-in active/not active …/…P (PNP): ≥ 10V/≤ 2 V or floating Teach-in duration max. 100ms Teach-in delay approx. 300 ms
1) Function: …/…P = active high (+24V); not active low (0V) The push-pull switching outputs must not be connected in parallel
2) 1=transient protection, 2=polarity reversal protection, 3=short circuit protection for all outputs
: 10kΩ
in
-2V)/≤ 2V
B
B
1)
Mode of operation
The "singlesheet" output sig­nals that an object is within the detection range. This out­put may be used to check for presence.
A detected double sheet is signaled at the "double sheet" output.
In the standard mode, 2-layer paper sheets with weights between approx. 40g/m² and approx. 400g/m² are detected without additional calibration.
With the "teach-in", the measurement range limits can be expanded to between approx. 20g/m² and approx. 800g/m².
The calibration process is started by applying a high signal at the "teach-in" input.
Calibration is performed either directly on a medium ­if a sheet is in the detection range at the calibration time ­or calibration is performed automatically if a medium is inserted into the detection range after the calibration time.
The calibration process is concluded after approx. 100ms.
When switched back on, the sensor again functions in standard mode
2
40g/m
…400g/m2.
Order guide
Designation Part No.
M12 connector GSU 710/66.4P-S12 50108702
400mm cable with M12 connector GSU 710/66.4P, 400-S12 50112912
Remarks
Intended use:
The GSU 710 double sheet testing unit is a monitoring unit predominately designed for single sheet checking in paper processing machines.
Operate in accordance with intended use!
This product is not a safety sensor
and is not intended as personnel protection.
The product may only be put into
operation by competent persons.
Only use the product in accor-
dance with the intended use.
GSU 710/66 - 05 2014/06