GSU 710/66 Double Sheet Testing Unit
Dimensioned drawing
en 05-2014/06 50108368-01
Reliable detection of multi-layer paper and
plastic sheets and metal foils
Measurement range from 20g/m2 paper to
800g/m
2
cardboard
Plug connection
Operating state indicators via light-emitting
diodes
Push-pull switching outputs
Accessories:
(available separately)
M12 connectors (KD …)
Ready-made cables (K-D …)
A Through hole
B Minimum intrusion depth of sheet edge
C Inlay nut M4 possible
D Red indicator diode
E Yellow indicator diode
Electrical connection
We reserve the right to make changes • DS_GSU71066_en_50108368_01.fm
Leuze electronic GmbH + Co. KG In der Braike 1 D-73277 Owen Tel. +49 (0) 7021 573-0
• www.leuze.com
GSU 710/66 - 05

GSU 710/66
Specifications
Physical data
Mouth width 13mm
Mouth depth 89mm
Minimum intrusion depth 31mm
Converter frequency approx. 330kHz
Timing
Switching frequency 200Hz
Response time 5ms
Delay before start-up ≤ 300ms acc. to IEC 60947-5-2
Electrical data
Operating voltage UB 18 … 30VDC (incl. residual ripple)
Residual ripple ≤ 15% of U
Open-circuit current ≤ 50mA
Switching outputs 2 push-pull switching outputs
Function characteristics single sheet detected, or ≥ 1 sheet
Signal voltage high/low ≥ (U
Output current max. 100mA per output
double sheet detected, or ≥ 2 sheets
Indicators
Yellow LED single sheet detected
Red LED double sheet detected
Mechanical data
Housing plastic
Color red
Weight approx. 100g
Connection type M12 connector, 5-pin, or
cable 400mm with M 12 connector, 5-pin
Environmental data
Ambient temp. (operation/storage) 0°C … +50°C/-40°C … +70 °C
Protective circuit
VDE safety class II, all-insulated
Protection class IP 40
Standards applied IEC 60947-5-2
2)
1, 2, 3
Options
Teach-in input
Teach-in input resistance R
Teach-in active/not active …/…P (PNP): ≥ 10V/≤ 2 V or floating
Teach-in duration max. 100ms
Teach-in delay approx. 300 ms
1) Function: …/…P = active high (+24V); not active low (0V)
The push-pull switching outputs must not be connected in parallel
2) 1=transient protection, 2=polarity reversal protection, 3=short circuit protection for all outputs
: 10kΩ
in
-2V)/≤ 2V
B
B
1)
Mode of operation
The "singlesheet" output signals that an object is within
the detection range. This output may be used to check for
presence.
A detected double sheet is
signaled at the "double
sheet" output.
In the standard mode, 2-layer
paper sheets with weights
between approx. 40g/m²
and approx. 400g/m² are
detected without additional
calibration.
With the "teach-in", the
measurement range limits
can be expanded to between
approx. 20g/m² and approx.
800g/m².
The calibration process is
started by applying a high
signal at the "teach-in" input.
Calibration is performed
either directly on a medium if a sheet is in the detection
range at the calibration time or calibration is performed
automatically if a medium is
inserted into the detection
range after the calibration
time.
The calibration process is
concluded after approx.
100ms.
When switched back on, the
sensor again functions in
standard mode
2
40g/m
…400g/m2.
Order guide
Designation Part No.
M12 connector GSU 710/66.4P-S12 50108702
400mm cable with M12 connector GSU 710/66.4P, 400-S12 50112912
Remarks
Intended use:
The GSU 710 double sheet
testing unit is a monitoring
unit predominately designed
for single sheet checking in
paper processing machines.
Operate in accordance with
intended use!
This product is not a safety sensor
and is not intended as personnel
protection.
The product may only be put into
operation by competent persons.
Only use the product in accor-
dance with the intended use.
GSU 710/66 - 05 2014/06