GSU 06 Ultrasonic Label Fork
Dimensioned drawing
en 07-2011/01 50040961
2.5mm
Forked sensor for reliable detection of:
- foil labels on foil carrier
- foil labels on paper carrier
- paper labels on paper carrier
- metallic foil labels
- thin metal foils
Special variant for tape-tear monitoring
Simple adjustment via teach-in by pressing
a button or remote calibration
1
Static PNP and NPN transistor outputs for
optimum adaptation to the controller
Robust metal housing with beveled inlet
edges
M8/M12 connector or cable version
1) Not applicable for GSU 06/24D.1-2-S8
A Sensor marker
B Teach-in button
C Teach-in indicator diode
D Indicator diode switching output
1)
1)
Electrical connection
Accessories:
(available separately)
M8/M12 connectors (KD …)
Ready-made cables M8/M12 (K-D …)
We reserve the right to make changes • DS_GSU06_24_en.fm
Leuze electronic GmbH + Co. KG In der Braike 1 D-73277 Owen Tel. +49 (0) 7021 573-0
• www.leuze.com
GSU 06… - 07
GSU 06
Specifications
Physical data
Mouth width 2.5mm
Mouth depth 48mm
Label length
Label gap
Conveyor speed 2m/s (120m/min)
Repeatability
Delay before start-up 100ms
1)
1)
1) 2)
2mm
2mm
±0.3mm
Electrical data
Operating voltage UB 10 … 30VDC (incl. residual ripple)
Residual ripple 15% of U
Open-circuit current 40mA
Switching outputs PNP and NPN transistor output
Function characteristics light or dark switching
Signal voltage high/low (U
Output current 2x 100 mA
-2V)/ 2V
B
B
Indicators
Green LED ready
Green LED, flashing teach-in activated
Yellow LED switching point in the label gap
Mechanical data
Housing aluminum, anodized
Color red/black
Weight 150g (connector/cable 60g)
Connection type M8 connector, 4-pin, or
2000mm cable, 5-pin, or
cable 200mm with M12 connector, 5-pin
Environmental data
Ambient temp. (operation/storage) +5°C … +50°C/-40°C … +70°C
Protective circuit
VDE safety class III
Protection class IP 62
Standards applied IEC 60947-5-2
3)
1, 2
Options (cable version)
Teach-in input
Active/not active 8V/ 2V
Activation/disable delay 0.2 ms
Input resistance 10k
1) Not applicable for GSU 06/24D.1-2-S8
2) Material dependent
3) 1=polarity reversal protection, 2=short-circuit protection for all outputs
Order guide
Designation Part No.
Light switching
(signal in the label gap)
With M8 connector,
teach-in by pressing a button
With 2m cable,
teach-in by pressing a button or via remote calibration
Dark switching
(signal on the label)
With M8 connector,
teach-in by pressing a button
With M8 connector,
teach-in by pressing a button or via remote calibration
1)
With 2m cable,
teach-in by pressing a button or via remote calibration
With 0.2m cable with M12 connector,
teach-in by pressing a button or remote calibration
With M8 connector,
specifically for tape-tear monitoring, without adjustment
1) When using right-angle plugs: cable outlet should point upward!
GSU 06/24-2-S8 50039638
GSU 06/24-2 50040191
GSU 06/24D-2-S8 50040190
GSU 06/4D.3-S8 50102921
GSU 06/24D-2 50040192
GSU 06/24D-2, 200-S12 50108819
GSU 06/24D.1-2-S8 50105735
Calibration
1)
Manual teach-in
Insert label tape.
The button on the device is
pressed to teach - green LED
flashes.
Label tape advances so that
5 … 10 label gaps pass
through the measuring zone.
The button is then pressed
again. The green LED illuminates continuously. The
teaching process is
concluded.
Remote teach-in
Insert label tape.
Apply voltage at "Teach in"
control input. Teach-in is
activated.
Advance 5 … 10 label gaps
through the sensor.
Remove voltage.
Teach-in is finished
A Sensor center, marker
B Label run
Remarks
Approved purpose:
This product may only be
used by qualified personnel
and must only be used for the
approved purpose. This
sensor is not a safety sensor
and is not to be used for the
protection of persons.
The center of the label tape
should be positioned above
the sensor’s marker (A).
To achieve high repeatability,
the label tape must be slightly
under tension (B).
The label material used deter-
mines the achievable
precision and the reliability of
gap detection!
With special variant GSU 06/
24D.1-2-S8 for tape-tear
monitoring, no adjustment is
necessary.
GSU 06… - 07 2011/01