Indicates dangers that may result in property damage if the measures for danger avoidance are not followed.
Table 1.2:Other symbols
Symbol for tips
Text passages with this symbol provide you with further information.
About this document
Table 1.3:Terms and abbreviations
BCLBar code reader
CRCCD based bar code reader
DTMSoftware device manager
EMCElectromagnetic compatibility
ENEuropean standard
FDTSoftware frame for management of device managers (DTM)
FEFunctional earth
GUI Graphical User Interface
HID Device class for input devices with which users directly interact
Symbols for action steps
Text passages with this symbol instruct you to perform actions.
(Code Reader)
(Device Type Manager)
(Field Device Tool)
(Human Interface Device)
IO or I/OInput/Output
LEDLight Emitting Diode
PLCProgrammable Logic Control
Leuze electronicCR 555
Page 5
2Safety
This sensor was developed, manufactured and tested in line with the applicable safety standards. It corresponds to the state of the art.
2.1Intended use
The CR 55 bar code reader is designed as a stationary scanner with integrated decoder for all common
bar codes used for automatic object detection.
Areas of application
The CR 55 bar code reader is intended especially for the following areas of application:
• automatic analyzers
• space-critical bar code reading tasks
• automation technology
NOTICE
Comply with conditions and regulations!
Observe the locally applicable legal regulations and the rules of the employer's liability insurance asso-
ciation.
Safety
2.2Foreseeable misuse
Any use other than that defined under “Intended use” or which goes beyond that use is considered
improper use.
In particular, use of the device is not permitted in the following cases:
• Rooms with explosive atmospheres
• Circuits relevant to safety
• Operation for medical purposes
NOTICE
Do not modify or otherwise interfere with the device.
Do not carry out modifications or otherwise interfere with the device.
The device must not be tampered with and must not be changed in any way.
The device must not be opened. There are no user-serviceable parts inside.
Repairs must only be performed by Leuze electronic GmbH + Co. KG.
2.3Competent persons
Connection, mounting, commissioning and adjustment of the device must only be carried out by competent
persons.
Prerequisites for competent persons:
• They have a suitable technical education.
• They are familiar with the rules and regulations for occupational safety and safety at work.
• They are familiar with the technical description of the device.
• They have been instructed by the responsible person on the mounting and operation of the device.
Certified electricians
Electrical work must be carried out by a certified electrician.
Due to their technical training, knowledge and experience as well as their familiarity with relevant stan-
dards and regulations, certified electricians are able to perform work on electrical systems and independently detect possible dangers.
In Germany, certified electricians must fulfill the requirements of accident-prevention regulations BGV A3
(e.g. electrician foreman). In other countries, there are respective regulations that must be observed.
Leuze electronicCR 556
Page 6
2.4Disclaimer
Leuze electronic GmbH + Co. KG is not liable in the following cases:
• The device is not being used properly.
• Reasonably foreseeable misuse is not taken into account.
• Mounting and electrical connection are not properly performed.
• Changes (e.g., constructional) are made to the device.
Safety
Leuze electronicCR 557
Page 7
3Device description
1
2
3.1Device overview
3.1.1The CR 55 bar code reader
Device description
The bar code reader is a CCD based
codes, e.g. 2/5 Interleaved, Code 39, Code 128, EAN etc.
The many possible configurations of the device allow it to be adapted to a multitude of reading tasks. Due
to the small dimensions of the unit and its large reading field, the bar code reader can also be used in highly
constrained spaces.
Information on technical data and characteristics: see chapter 11.
3.1.2Stand alone operation
The bar code reader is operated as a “stand-alone” single device.
open ends for the electrical connection of the supply voltage, the interface, the switching input and the
switching output.
3.2Performance characteristics
• High-performance CCD scanner with front beam exit
• Compact design for simple integration, even in constrained spaces
• Robust metal housing with cable connection
• RS 232 interface, one switching input, one switching output
3.3Device construction
line scanner with integrated decoder for all commonly used bar
It is equipped with a six-wire cable with
1Reading window with front beam exit
2LED indicators
Figure 3.1:Device construction of the CR 55
3.4Connection technology
• Cable connection
• Alternative: customer-specific solutions
Leuze electronicCR 558
Page 8
3.5Display elements
Located on top of the bar code reader are two LEDs that indicates the readiness for operation and the read
status of the bar code reader.
3.5.1LED indicators
Two LEDs on the top of the device indicate the device and read status:
Table 3.1:LED indicators
LEDStateDescription
Device description
PWRON (continuous
light)
GOOD READON (continuous
light)
Voltage supply OK
Reading successful
Leuze electronicCR 559
Page 9
4Mounting
α
β
γ
You can fasten the bar code reader at the M2.5 mounting threads.
4.1Selecting a mounting location
The size of the bar code module influences the maximum reading distance and the width of the
reading field. Therefore, when selecting a mounting location and/or the bar code label, take into
account the different reading characteristics of the scanner with various bar code modules.
NOTICE
Observe when choosing the mounting location!
Maintaining the required environmental conditions (temperature, humidity).
Possible soiling of the reading window due to liquids, abrasion by boxes, or packaging material resi-
dues.
Lowest possible chance of damage to the scanner by mechanical collision or jammed parts.
Possible extraneous light influence (no direct sunlight).
In order to select the right mounting location, several factors must be considered:
• size, orientation, and position tolerance of the bar codes on the objects to be scanned.
• The reading field of the bar code reader in relation to the bar code module width.
• The bar code reader is designed for reading codes in ladder orientation.
• the resulting minimum and maximum reading distance from the respective reading field; see
figure 11.1.
• alignment of the bar code reader for avoiding reflections.
• distance between bar code reader and host system with respect to the interface.
Mounting
The best read results are obtained when
• the reading distance lies in the middle area of the reading field.
• there is no direct sunlight and extraneous light is avoided.
• the bar code labels are of good print quality and have good contrast ratios.
• you do not use high-gloss labels.
• the bar code is moved past the reading window with a rotational angle of 10° to 15°.
• the red light beam is narrowed down for its respective reading task in order to avoid reflections on
shiny components.
With front-side beam exit, the beam exits the bar code reader nearly perpendicular to the reading
window. The bar code label must be rotated by > 10° to avoid a total reflection of the red light
beam in the case of glossy labels.
αAzimuth angle
Figure 4.1:Definition of the reading angles
βAngle of inclination
γAngle of rotation
Recommended angle of rotation: γ > 10°
Leuze electronicCR 5510
Page 10
5Electrical connection
CAUTION
Safety notices
The bar code reader is completely sealed and must not be opened.
Do not try to open the device under any circumstances, as this voids both degree of protection IP 54
and the warranty.
Before connecting the device, be sure that the supply voltage agrees with the value printed on the
name plate.
Connection of the device and maintenance work while under voltage must only be carried out by a
qualified electrician.
The power supply unit for the generation of the supply voltage for the bar code reader and the corre-
sponding connection units must have a secure electrical insulation according to IEC 60742 (PELV).
For UL applications: only for use in “class 2” circuits according to NEC.
If faults cannot be corrected, the device should be removed from operation and protected against pos-
sible commissioning.
5.1Voltage supply
The bar code reader is designed for connection to a 5 V supply voltage.
Electrical connection
• +5 V DC (red)
• GND (violet)
Available as an accessory is an adapter circuit board with spring terminals and 9-pin SUB-D socket; see
chapter 12.2 "Accessories".
• With the adapter circuit board, the conductors of the connection cable can be contacted via the
spring terminals and connected to the PC via the 9-pin SUB-D socket with an RS 232 interconnection cable.
• With the adapter circuit board, the voltage supply from 10 … 30 V DC can be fed in via spring terminals or, alternatively, 5 V DC can be fed in via a micro USB connector.
5.2Pin assignment of the connection cable
WireAssignmentDescription
Red+5V DCOperating voltage 5V DCIN
VioletGNDOperating voltage 0V DC / reference groundIN
BlackSW OUTSwitching outputOUT
OrangeSW INSwitching inputIN
WhiteRS 232 RxDRxD signal line of the RS 232 interfaceIN
GreenRS 232 TxDTxD signal line of the RS 232 interfaceOUT
5.3Switching input/Switching output
The bar code reader is provided with a switching input and a switching output.
• The switching input is used to trigger reading.
• The switching output signals successful code reading.
5.3.1Switching input
By means of the SW IN switching input connection, you can trigger a read process in the standard setting
(low = active) with the connection SW IN (orange) and GND (violet). We recommend wiring a 2.2 kΩ “pullup” resistor as defined cable termination; see figure 5.1.
Leuze electronicCR 5511
Page 11
4.9 … 5.4 V DC
+ 5 V DC
OUT
GND
GND
+ 5 … 30 V DC
max. 20 mA !
R
L
4.9 … 5.4 V DC
1
2
3
GND
1Red
2Orange
3Violet
Figure 5.1:Wiring example of the trigger input
5.3.2Switching output
The NPN switching output connection between SW
detected against GND.
+ 5 V DC
1
2.2 k
SW_IN
2
GND
3
Connection version NPN: standard setting (low = active)
OUT (black) and GND (violet) switches if a code is
Electrical connection
5.4PC or terminal connection
Leuze electronicCR 5512
1Red
2Black
3Violet
Figure 5.2:Switching output
NOTICE
Maximum loading of the switching output
Do not load the switching output of the bar code reader with more than 20 mA at +5 … 30 V DC!
Via the serial interface, you can configure the bar code reader by means of a PC or terminal. For this, you
need an RS 232 connection that establishes the RxD, TxD and GND connections between PC and bar
code reader.
The RS 232 connection can be established in the following ways:
• Direct connection of the bar code reader connection wires to the PC or terminal via its own connector.
• Connection via an MA-CR adapter circuit board
To simplify the connection of the connection wires to the PC interface, an adapter circuit board (MACR) is available for implementing individual wire contacting to SUB-D, 9-pin; see chapter 12.2.
Page 12
1RS 232 connection
1
2
1011
3
4
8
9
567
7
2CR 50 connection
3CR 100 or CR 55 connection
4Molex Micro-Fit, 6-pin
5USB connection
6Connection to machine control, PLC, external voltage supply 5 VDC
7External voltage supply 10 … 30 VDC
8SWIN DIP switch (level for trigger button; 5 V if the scanner high switching input is active, GND if the
low input is active)
9USB/PWR DIP switch (USB position if voltage is supplied via USB; PWR position if voltage is sup-
plied via )
10Trigger button
11Status LEDs
Figure 5.3:Connection options for MA-CR adapter circuit board
Electrical connection
NOTICE
Using the adapter circuit board
The MA-CR adapter circuit board is intended only for laboratory and test purposes and is not to be
used for industrial applications!
5.5Cable lengths and shielding
The maximum cable length is 3 m.
Should a cable extension be necessary, make certain that the cables of the RS 232 interface are shielded.
Leuze electronicCR 5513
Page 13
Configuration and diagnostic software - Sensor Studio
6Configuration and diagnostic software -
The
Sensor Studio
tion and diagnosis of the device via the RS 232 interface.
A device that is not connected to the PC can be configured offline.
Configurations can be saved and reopened as projects for transferring back to the device at a later time.
Only use the
Leuze electronic.
The
lish, French, Italian and Spanish.
The FDT frame application of the
be supported in the device DTM (Device Type Manager).
Sensor Studio
The
• You make the individual configuration settings for the bar code reader in the Device Type Manager
(DTM).
• The individual DTM configurations of a project can be called up via the frame application of the Field
Device Tool (FDT).
• Communication DTM for bar code readers:
• Device DTM for bar code readers CR 55
Procedure for the installation of the software and hardware:
Install the
Install the communication and device DTM.
Communication and device DTM are included in the
Create CR 55-DTM in the project tree of the
Connect bar code reader to PC; see chapter 5.4
Activate service interface on bar code reader; see chapter 7.3.2
configuration software provides a graphical user interface for the operation, configura-
Sensor Studio
Sensor Studio
configuration software is offered in the following languages: German, Eng-
configuration software for products manufactured by
Sensor Studio
configuration software is designed according to the FDT/DTM concept:
Sensor Studio
configuration software on the PC.
Sensor Studio
supports all languages; all languages may not
LeCommInterface
LeAnalysisCollectionSetup
Sensor Studio
FDT frame.
installation package.
6.1System requirements
To u se the
Table 6.1:
Sensor Studio
System requirements for Sensor Studio
Operating systemWindows XP or higher (32 bit, 64 bit)
Computer
Graphics cardAt least 1024 x 768 pixels
Required hard disk
capacity for
Sensor Studio
communication DTM
configuration software, you need a PC or laptop with the following specifications:
installation
Windows Vista
Windows 7
Windows 8
• Processor type: 1 GHz or higher
• Serial COM interface
• CD drive
• Main memory (RAM): at least 64 MB
• Keyboard and mouse or touchpad
35 MB
and
Leuze electronicCR 5514
Page 14
Configuration and diagnostic software - Sensor Studio
Administrator privileges on the PC are necessary for installing
6.2Installing
6.2.1Downloading configuration software
Ca
Enter the type designation or part number of the device as the search term.
The configuration software can be found on the product page for the device under the
Sensor Studio configuration software
The installation files of the
Internet at www.leuze.com.
For subsequent updates, you can find the most recent version of the
software on the Internet at www.leuze.com.
ll up the Leuze home page: www.leuze.com
On delivery, the device is configured for HID operation (Human Interface Device). The device
can thereby be operated directly via the Windows application.
If you would like to make other settings via the USB interface, you must download the USB driver
from the Leuze home page (file name
Sensor Studio
SW_CR5x_Virtual_COM_Port_Drivers...
Sensor Studio
configuration software must be downloaded from the
Sensor Studio
.
Downloads
).
installation
tab.
6.2.2Installing the
NOTICE
First install the software!
Do not yet connect the device to the PC.
First install the software.
If FDT frame software is already installed on your PC, you do not need the
lation.
You can install the communication DTM and the device DTM in the existing FDT frame. Commu-
nication DTM and device DTM are included in the
age.
art the PC.
St
Download the configuration software from the Internet to the PC; see chapter 6.2.1.
Unpack the installation package.
Start the
Follow the instructions on the screen.
The Installation Wizard installs the software and places a shortcut on the desktop ( ).
Sensor Studio
FDT frame
SensorStudioSetup.exe
file.
Sensor Studio
LeAnalysisCollectionSetup
instal-
installation pack-
6.2.3Install the communication DTM and device
Prerequisites:
• An FDT frame is installed on the PC.
Start the
screen.
The installation wizard installs communication DTM and device DTM for CR 55.
Leuze electronicCR 5515
LeAnalysisCollection.exe
DTM
file from the installation package and follow the instructions on the
Page 15
6.2.4Connecting bar code reader to PC
The bar code reader is connected to the PC via the RS 232 interface. F
connection that establishes the RxD, TxD and GND connections between PC and bar code reader; see
chapter 5.4.
• You need an RS 232 connection that establishes the RxD, TxD and GND connections between PC
and bar code reader; see chapter 5.4.
• The 5 V DC voltage supply is to be fed in externally; see chapter 5.1.
The MA-CR adapter circuit board with spring terminals for connecting the bar code reader, as
well as 9-pin SUB-D socket for connecting an RS 232 interconnection cable, is available as an
accessory. An RS 232 interconnection cable to the PC is also available as an accessory; see
chapter 12 "Ordering information and accessories".
The adapter circuit board requires 10 V … 30 V DC as external voltage supply, which can be fed
in via spring terminals. Alternatively, 5 V DC can be fed in via a micro USB connector.
Configuration and diagnostic software - Sensor Studio
or this, you need an RS 232
6.3Starting the
configuration software
Prerequisites:
• The bar code reader has been mounted (see chapter 4) and connected (see chapter 5) correctly.
• The bar code reader is connected to the PC via the RS 232 interface (see chapter 6.2.4).
• The service interface is activated on the bar code reader; see chapter 7.3.2
•The
Sensor Studio
Sensor Studio configuration software").
Start the
The mode selection of the Project Wizard is displayed.
Select the Device selection without communication connection (offline) configuration mode and click on
[Next].
The Project Wizard displays the device selection list of the configurable devices.
Sensor Studio
configuration software is installed on the PC (see chapter 6.2 "Installing
Sensor Studio
configuration software by double-clicking the
Sensor Studio
icon ( ).
Leuze electronicCR 5516
Page 16
Configuration and diagnostic software - Sensor Studio
Figure 6.1:Device selection for bar code reader CR 55
Select CR 55 in the device selection and click on [Next].
The device manager (DTM) of the connected CR 55 starts with the offline view for the
configuration project.
Establish the online connection to the connected CR 55.
In the
In the
Sensor Studio
Sensor Studio
FDT frame, click on the [Establish connection with device] button ( ).
FDT frame, click on the [Upload parameters to device] button ( ).
The current configuration data is displayed in the device manager (DTM).
Sensor Studio
Leuze electronicCR 5517
Page 17
Configuration and diagnostic software - Sensor Studio
Figure 6.2:Configuration project:
The menus of the
uration of the connected bar code reader.
The user interface of the
The online help system provides information on the menu items and adjustment parameters. Select the
Help menu item in the menu [?] ( ).
Transfer the modified configuration parameters to the device.
If a connection exists, click on the [Download parameters to device] button ( ) on the task bar.
6.4Exiting
After completing the configuration settings, close the
Exit the program via File > Exit.
Save the configuration settings as a configuration project on the PC.
You can open the configuration project again at later time via File > Open or with the
Wizard ( ).
Sensor Studio
Sensor Studio
6.5Configuration parameters
In this chapter, you will find information and explanations on the configuration parameters of the device
manager (DTM) for the CR 55 bar code reader.
This chapter does not include a complete description of the
ware.
Sensor Studio
device manager (DTM) can be used to change or read out the config-
Sensor Studio
device manager (DTM) for CR 55
device manager (DTM) is largely self-explanatory.
Sensor Studio
configuration software
Sensor Studio
Sensor Studio
configuration soft-
Project
Complete information on the FDT frame menu and on the functions in the device manager (DTM)
can be found in the online help system.
The device manager (DTM) for CR 55 bar code readers of the
the following configuration functions:
General
•
•
Decode
•
Host Interface;
•
Diagnosis
•
Change firmware (Maintenance)
Leuze electronicCR 5518
; see chapter 6.5.2
see chapter 6.5.3
; see chapter 6.5.4
Sensor Studio
configuration software offers
Page 18
The online help system displays information on the menu items and configuration parameters for
each function. Select the Help menu item in the menu [?]
6.5.1General tab
Configuration and diagnostic software - Sensor Studio
Figure 6.3:General tab
Scan ModeHere you can select how a read process is to be activated.
LED Sleep TimeoutSetting for the length of time after which the read LED in presentation mode is
switched off.
Same Code DelayLength of time during which identical codes are output only once during multiple
reading.
Inverse CodeReading of inverse codes.
General SettingsSettings for the integrated buzzer.
Leuze electronicCR 5519
Page 19
6.5.2Decode tab
Configuration and diagnostic software - Sensor Studio
Figure 6.4:Decode tab
Code table
(DECODER OVERVIEW)
Properties
(Symbologies)
Here, the codes which are to be decoded are set. We recommend enabling only
the code types which are to actually be read with the corresponding element numbers. Codes which are not enabled are not decoded!
Use the […] button to the right of the given code to select the code-specific settings.
Alternatively, the property settings can be selected directly via the navigation tree
under the [Decode] button.
The properties can be individually set for each code type.
Figure 6.5:Standard settings for the Properties window (Symbology Properties) – Decode tab
Leuze electronicCR 5520
Page 20
6.5.3Host interface tab
Configuration and diagnostic software - Sensor Studio
Figure 6.6:Host interface tab
elect the desired baud rate, the stop bits, the data bits, the parity and various transmission modes here.
S
The desired acknowledgment settings are also to be set in this selection window.
6.5.4Maintenance / software update
Figure 6.7:Firmware reload
With this tool, new firmware files can first be selected for the CR 50 or CR 55 bar code reader, then they
can be loaded into the tool and subsequently executed.
Leuze electronicCR 5521
Page 21
7Starting up the device - Configuration
7.1Measures to be performed prior to the initial commissioning
NOTICE
Please observe the notices for device arrangement, see chapter 4.1.
If possible, always trigger the scanner with the aid of commands or an external signal transmitter (pho-
toelectric sensor).
Before commissioning, familiarize yourself with the operation and configuration of the device(s).
Before connecting the supply voltage, recheck all connections and ensure that they have been prop-
erly made.
7.2Starting the device
7.2.1Interface
Proper function of the interf
with the
Sensor Studio
ace can be most easily tested in service operation using the serial interface
configuration software and a notebook computer.
Starting up the device - Configuration
7.2.2“Online commands”
Using the “Online” commands, important device functions can be che
7.2.3Problems
If a problem occurs that cannot be
the devices and on the host, contact your responsible Leuze electronic subsidiary or Leuze electronic
customer service, see chapter 10.
rectified even after checking all electrical connections and settings on
7.3Setting the communication parameters
You have now commissioned the bar code reader. Usually, you will have to configure it before you can
use it. Using the configuration options offered in the
bar code reader can be individually configured according to your application. For information on the
various configuration options, see chapter 6 or refer to the online help.
To operate the bar code reader, it is normally sufficient to set code type and code length in accordance
with the bar codes that are to be read.
The setting of code type and code length is usually accomplished by using the
software, see chapter 6.
The various parameter sets are explained in brief to understand what is happening during parameter
setting, see chapter 7.3.1.
The parameters are then set using the buttons under CONFIGURATION. To transfer the settings to the
bar code reader, its RS 232 settings must be set to the “Service” operating mode, see chapter 7.3.2.
Sensor Studio
cked, e.g. reading activation.
or by means of the device DTM, the
Sensor Studio
configuration
7.3.1Parameter sets
factory default parameter set
parameter set contains the default settings made ex works for all parameters of the bar code reader.
This
It is permanently stored in the FLASH ROM of the bar code reader.
The parameter set with the default settings is loaded into the memory of the bar code reader:
• the first time the device is commissioned after delivery
• following the command “Factory Default” in the configuration program (online command ’PC20’)
• if the checksums of the current parameter set are invalid
Current parameter set
In this parameter set, the current settings for all device parameters are stored. When the bar code reader
is in operation, the parameter set is stored in the EEPROM of the bar code reader.
Leuze electronicCR 5522
Page 22
The current set can be stored:
• by copying a valid parameter set from the host computer in the bar code reader
• by an off-line setup using the
the bar code reader
The current parameter set is loaded into the memory of the bar code reader:
• by a parameter command, see chapter "Parametersatz kopieren"
7.3.2“Service” operating mode
You can connect a PC or a terminal to the bar code reader via the serial interface and configure the bar
code reader through this connection; see chapter 5.4 "PC or terminal connection".
Setting the required parameters is most easily carried out in the “Service” operating mode.
The operating mode “Service” provides the following defined operating parameters on the RS 232 interface, no matter how the bar code reader is configured for standard operation:
• transmission rate: 9600 baud
• no parity
• 8 data bits
• 1 stop bit
Sensor Studio
Starting up the device - Configuration
configuration software and then subsequently copying to
Activating the service interface
The service interface can be activated by holding a defined bar code label (“Service”, see figure 7.1) in
front of the reading window during power-up (initialization phase).
Figure 7.1:Bar code label “Service”
While the red light is switched on for approx. 1 s after power-up, the “Service” label is to be held up in front
of the bar code reader at a suitable read distance. When the device is in “Service” mode, the status LED
flashes.
Leuze electronicCR 5523
Page 23
8Online commands
8.1Overview of commands and parameters
Online commands can be used to send commands directly to the device for control and configuration. For
this, the bar code reader has to be connected to a computer (host) via the serial interface, see
chapter 7.3.2.
Information about the transmission protocol: see chapter 0.1.4.
Using the “online” commands you can:
• query the device version.
• activate and deactivate code reading.
• perform a software reset.
Syntax
“Online” commands consist of one or two ASCII characters followed by command parameters.
No separation characters may be entered between the command and the command parameter(s). Both
small and capitalized letters can be used.
Example:
Command ’H’:Software reset
Online commands
Parameter ’+’:Activation
Transmitted is:’H+’
Notation
Commands, parameters and returned data are enclosed between single quotation marks ’ ’ in the text of
this manual.
Most online commands are acknowledged by the device and any requested data returned. For commands
that are not acknowledged, command execution can be observed or monitored directly on the device.
8.2General online commands
Software version number
Command’V’
DescriptionRequests device version information
Parameternone
Acknowledgment Example: ’CR55 Series V 00.91 02.07.2014
The device type appears in the first line followed by the device's version number and
date. The data which is actually displayed may vary from the values given here.
You can use this command to check whether the communication between PC and scanner is
functional. If you do not receive an acknowledgment, please check the interface connections or
the protocol.
Software reset
Command’H’
DescriptionCarries out a software reset. The device is restarted and reinitialized, leaving it in the
same state as when the supply voltage is switched on.
ParameterNo
Acknowledgment ’S’ (start signal)
Leuze electronicCR 5524
Page 24
8.3Online commands for system control
Activating sensor input
Command’+’
DescriptionThe command activates decoding.
Parameternone
Acknowledgment none
Deactivating sensor input
Command’-’
DescriptionThe command deactivates decoding.
Parameternone
Acknowledgment none
Online commands
Leuze electronicCR 5525
Page 25
9Care, maintenance and disposal
Usually, the bar code reader does not require any maintenance by the operator.
9.1Cleaning
Clean the glass window of the bar code reader with a soft cloth before mounting.
NOTICE
Do not use aggressive cleaning agents!
Do not use aggressive cleaning agents such as thinner or acetone to clean the device.
9.2Servicing
Repairs to the device must only be carried out by the manufacturer.
For repairs, contact your responsible Leuze electronic subsidiary or Leuze electronic customer service
(see chapter 10).
9.3Disposing
For disposal observe the applicable national regulations regarding electronic components.
Care, maintenance and disposal
Leuze electronicCR 5526
Page 26
10Service and support
24-hour on-call service at:
+49 (0) 7021 573-0
Service hotline:
+49 (0) 7021 573-123
Monday to Friday 8.00 a.m. to 5.00 p.m. (UTC+1)
E-mail:
service.identify@leuze.de
Return address for repairs:
Service center
Leuze electronic GmbH + Co. KG
In der Braike 1
D-73277 Owen / Germany
10.1What to do should servicing be required?
Service and support
NOTICE
Please use this chapter as a master copy should servicing be required!
Enter the contact information and fax the form together with your service order to the fax number given
below.
Customer data (please complete)
Device type:
Serial number:
Firmware:
Display messages:
LED states:
Error description:
Company:
Contact person/department:
Phone (direct):
Fax:
Street/No:
ZIP code/City:
Country:
Leuze Service fax number:
+49 (0) 7021 573-199
Leuze electronicCR 5528
Page 27
11Technical data
11.1General specifications
Table 11.1: Optics
Light sourceLED 617 nm (visible red light)
Wavelength617 nm
Beam exitfront
Scanning ratetypically 330 scans/s
Module width5 … 20 mil
Reading distancesee chapter 11.2 "Reading fields"
Reading field openingsee chapter 11.2 "Reading fields"
Interface typeRS 232 or USB 2.0 (virtual COM, HID)
Baud rate300 … 115200 baud
Supply voltage4.5 … 5.5 V DC, Safety Class III - PELV (Protec-
tive Extra Low Voltage)
Notice:
For UL applications: only for use in “Class 2” circuits according to NEC
Current consumptionmax. 120 mA
Ports1 switching input 5 V DC
1 switching output 5 … 30 V, 20 mA
LEDs1 device status
1 read status
Table 11.3: Mechanics
Degree of protectionIP 54
Connection typeRS 232: fixed cable 2 m long, 6 x 0.081 mm
2
(AWG 28)
USB: fixed cable, 1.8 m long
Weight45 g (without cable)
Dimensions (H x W x D) 18.3 x 31x 45.5 mm
Housingmetal, die-cast aluminum
Leuze electronicCR 5529
Page 28
Table 11.4:Environmental data
-70
-60
-40
-30
-20
-10
0
10
20
30
40
60
70
0 306090120150180210240
-50
50
1234
5
Ambient temp. (operation/storage)0 °C … +50 °C/-20 °C … +60 °C
Air humiditymax. 90 % rel. humidity, non-condensing
Electromagnetic compatibilityEN 55022
ConformityCE, FCC
CertificationsUL 60950-1
11.2Reading fields
Please note that the actual reading fields are also influenced by factors such as labeling material,
printing quality, scanning angle, printing contrast etc., and may thus deviate from the reading
fields specified here. The origin of the read distance always refers to the front edge of the housing
of the beam exit.
Technical data
IEC 62471
CSA C22.2 No. 60950-1-07
Figure 11.1: CR 55 read field
15 mil (0.127 mm), Code 128
26.5 mil (0.165 mm), Code 128
38 mil (0.203 mm), Code 128
410 mil (0.254 mm), Code 128
520 mil (0.508 mm), Code 128
Leuze electronicCR 5530
Page 29
11.3Dimensioned drawings
Technical data
all dimensions in mm
Figure 11.2: Dimensioned drawing of CR 55 with front beam exit
Leuze electronicCR 5531
Page 30
12Ordering information and accessories
12.1Type overview
Table 12.1:Part numbers
Part no.Part designationDescription
50126080CR55M2/R2CCD line scanner, RS 232 interface, fixed cable,
50127723CR55M2/UB-1800-S6CCD line scanner, USB interface, fixed cable,
12.2Accessories
Table 12.2:Accessories
Part no.Part designationDescription
50128204MA-CRAdapter circuit board with spring terminals and 9-
Ordering information and accessories
2 m
1.8 m
pin SUB-D socket
50113396KB DSub-9P-3000RS 232 interconnection cable, cable length 3 m
USB driver for configuring the CR 55 scanner
Download at www.leuze.com
Sensor Studio
Download at www.leuze.com
see chapter 6.2.1 "Downloading configuration software"
configuration software
Sensor Studio
DTM concept. Contains: communication DTM and
device DTM
designed according to the FDT/
Leuze electronicCR 5532
Page 31
13EC Declaration of Conformity
The bar code readers of the CR 55 series have been developed and manufactured in accordance with the
applicable European standards and directives.
EC Declaration of Conformity
Leuze electronicCR 5533
Page 32
14Appendix
14.1Bar code samples
Module 0.3
Figure 14.1: Code type 01: Interleaved 2 of 5
Module 0.3
Figure 14.2: Code type 02: Code 39
Appendix
Module 0.3
Figure 14.3: Code type 11: Codabar
Module 0.3
Figure 14.4: Code 128
Module 0.3
Figure 14.5: Code type 08: EAN 128
SC 2
Figure 14.6: Code type 06: UPC-A
SC 3
Figure 14.7: Code type 07: EAN 8
Leuze electronicCR 5534
Page 33
SC 0 S
Figure 14.8: Code type 10: EAN 13 Add-on
Appendix
Leuze electronicCR 5535