Leroy-Somer R 450 M, R 450 T Installation And Maintenance Manual

2012.03 / d
Batterie (B Volt)
+
-
t
(400V - 10A)
Diode
F+
F-
VO IR N OT IC E SE E NO TI CE
F- X2 Z1
F+ Z2 X1
USC
R 450 M & T
This manual is to be given to
the end user
4342 en -
A.V.R.
Installation and maintenance
CALL US TODAY 1-888-POWER-58
REQUEST A QUOTE
parts@genpowerusa.com
SHOP ONLINE
www.dieselgeneratorusa.com
2
2010.03 / d
LEROY-SOMER
Installation and maintenance
R 450 M & T
A.V.R.
4342 en -
SAFETY MEASURES
Before using your machine for the rst time, it is important to read the whole of this installation and maintenance manual.
All necessary operations and interventions on this machine must be performed by a qualied technician.
Our technical support service will be pleased to provide any additional information you may require.
The various interventions described in this manual are accompanied by recommendations or symbols to alert the user to potential risks of accidents. It is vital that you understand and take notice of the various warning symbols used.
Warning symbol for an operation capable of damaging or destroying the machine or surrounding equipment.
Warning symbol for general danger to personnel.
Warning symbol for electrical danger to personnel.
Note: All rights are reserved to modify the characteristics of the products at any time in order to incorporate the latest technological developments. The information contained in this document may therefore be changed without notice.
WARNING
This manual concerns the alternator AVR which you have just purchased.
We wish to draw your attention to the contents of this maintenance manual. By following certain important points during installation, use and servicing of your AVR, you can look forward to many years of trouble-free operation.
CALL US TODAY 1-888-POWER-58
REQUEST A QUOTE
parts@genpowerusa.com
SHOP ONLINE
www.dieselgeneratorusa.com
2012.03 / d
3
LEROY-SOMER
Installation and maintenance
R 450 M & T
A.V.R.
4342 en -
CONTENTS
1 - GENERAL INFORMATION
...............................................................................................4
1.1 - Description
................................................................................................................... 4
1.2 - Identication
................................................................................................................. 4
1.3 - Tools
.............................................................................................................................4
2 - POWER SUPPLY
...............................................................................................................5
2.1 - AREP excitation system
............................................................................................... 5
2.2 - PMG excitation system
.................................................................................................6
2.3 - SHUNT or separate excitation system
..........................................................................7
3 - TECHNICAL CHARACTERISTICS
....................................................................................8
3.1 - Electrical characteristics
...............................................................................................8
3.2 - Congurations
.............................................................................................................. 8
3.3 - U/F and LAM functions
............................................................................................... 12
3.4 - Typical effects of the LAM with a diesel engine with or without a LAM (U/F only)
........12
3.5 - AVR options
...............................................................................................................13
4 - INSTALLATION - COMMISSIONING
...............................................................................14
4.1 - Electrical checks on the AVR
......................................................................................14
4.2 - Setting up
................................................................................................................... 14
4.3 - Electrical faults
........................................................................................................... 17
5 - SPARE PARTS
.................................................................................................................18
5.1 - Designation
................................................................................................................ 18
5.2 - Technical support service
........................................................................................... 18
All servicing or repair operations performed on the AVR should be undertaken by personnel trained in the commissioning, servicing and maintenance of electrical and mechanical components.
Copyright 2005 : MOTEURS LEROY-SOMER This document is the property of :
MOTEURS LEROY-SOMER It may not be reproduced in any form without prior authorization. All brands and models have been registered and patents applied for.
CALL US TODAY 1-888-POWER-58
REQUEST A QUOTE
parts@genpowerusa.com
SHOP ONLINE
www.dieselgeneratorusa.com
4
2010.03 / d
LEROY-SOMER
Installation and maintenance
R 450 M & T
A.V.R.
4342 en -
1 - GENERAL INFORMATION
1.1 - Description
The R450 AVR is supplied in a casing designed to be mounted on a panel with dampers.
- Operating temperature: 20°C to +70°C.
- Storage temperature: 55°C to +85°C.
- Shocks on the base: 9 g depending on the 3 axes.
- Vibrations: less than 10 Hz, 2 mm half-peak amplitude 10 Hz to 100 Hz: 100 mm/s, above 100 Hz: 8 g.
WARNING
The AVR is IP00, it must be incorporated in an environment which ensures it a IP20 protection.
1.2 - Identication
There are 2 different versions available:
- R 450M: single-phase sensing,
- R 450T: three-phase sensing,
These 2 AVRs are exactly identical in terms of characteristics and dimensions with “Mate N Lok™” connectors.
1.3 - Tools
The “Mate N Lok™” connectors tools references are the following:
- crimping pliers: Ref TYCO 654.149.1
- Extractor: Ref TYCO 539.972.1
WARNING
Connectors must be unlocked before unpluging.
R 450 M
VOIR NOT ICE
SEE NOTI CE
nc V W
DETECT. 1 PH 1 PH. SENSING
VOLT. STAB. I EXC
STAT.
FUSIBLES / FUSES
F- X2 Z1 F+ Z2 X1
1k
S1 S2
50 Hz 60 Hz
EXT FREQ SETTING
7
LAM
OFF
LAM
ON
ONLY FOR
SPECIAL
CONFIG.
KNEE
LAM OFF
65Hz
LAM
OFF
LAM
MODE 2
LAM
MODE 1
LAM
OFF
LAM
MODE 2
LAM
MODE 1
50Hz
EXT.FREQ.
SET.
60Hz
0
5
6
9
8
1
2
3
4
SERIES
LSA
49.1/ 50.2
7000/ 8000
SERIES
LSA
49.1/ 50.2
7000/ 8000
SERIES
LSA
46.2/ 47.2
5000/ 6000
SERIES
LSA
46.2/ 47.2
5000/ 6000
VOLTAGE 320V ~ 530V
VOLTAGE 80V ~ 320V
2
3
0
1
RAPIDE
FAST
RAPIDE
FAST
NORMAL
NORMAL
NORMAL
NORMAL
SHUNT / AREP
PMG
2
3
0
1
0
9
8
7
6
5
4
3
2
1
0
3
2
1
0
3
2
1
R 450 T
VOIR NOT ICE
SEE NOTI CE
U V W
DETECT. 3 PH 3 PH. SENSING
VOLT. STAB. I EXC
STAT.
FUSIBLES / FUSES
F- X2 Z1 F+ Z2 X1
1k
S1 S2
50 Hz 60 Hz
EXT FREQ SETTING
7
LAM
OFF
LAM
ON
ONLY FOR
SPECIAL
CONFIG.
KNEE
LAM OFF
65Hz
LAM
OFF
LAM
MODE 2
LAM
MODE 1
LAM
OFF
LAM
MODE 2
LAM
MODE 1
50Hz
EXT.FREQ.
SET.
60Hz
0
5
6
9
8
1
2
3
4
SERIES
LSA
49.1/ 50.2
7000/ 8000
SERIES
LSA
49.1/ 50.2
7000/ 8000
SERIES
LSA
46.2/ 47.2
5000/ 6000
SERIES
LSA
46.2/ 47.2
5000/ 6000
VOLTAGE 320V ~ 530V
VOLTAGE 80V ~ 320V
2
3
0
1
RAPIDE
FAST
RAPIDE
FAST
NORMAL
NORMAL
NORMAL
NORMAL
2
3
0
1
0
9
8
7
6
5
4
3
2
1
0
3
2
1
0
3
2
1
R 450 M
R 450 T
SHUNT / AREP
PMG
200 mm
140 mm
LEDS
LEDS
P1
Voltage
P2
Stability
P3
Excitation
Overrun indications
Fuses 10A
USC USC
Installation & maintenance manual :
www.leroy-somer.com
Installation & maintenance manual :
www.leroy-somer.com
P4
Quad droop
Rotating switch
- Lam and U/F
- Voltage
- Excitation
115 mm
4 holes Ø 6.5 mm
175 mm
CALL US TODAY 1-888-POWER-58
REQUEST A QUOTE
parts@genpowerusa.com
SHOP ONLINE
www.dieselgeneratorusa.com
2012.03 / d
5
LEROY-SOMER
Installation and maintenance
R 450 M & T
A.V.R.
4342 en -
2 - POWER SUPPLY
Both the AREP & PMG excitation systems are controlled by the AVR.
2.1 - AREP excitation system
With AREP excitation, the electronic AVR is powered by two auxiliary windings which are independent of the voltage sensing circuit.
The rst winding has a voltage proportional
to the alternator main voltage (Shunt characteristic), the second one has a voltage proportional to the stator current (compound characteristic : Booster effect). The power supply voltage is rectied and ltered before being used by the AVR monitoring transistor. The rotating switch should be in the AREP position (see 3.2.3).
R 450 T
VOIR NO TICE
SEE NOT ICE
U V W
DETECT. 3 PH
3 PH. SENSING
VOLT. STAB. I EXC
STAT.
FUSIBLES / FUSES
F- X2 Z1 F+ Z2 X1
1k
S1 S2
50 Hz 60 Hz
EXT FREQ SETTING
7
LAM
OFF
LAM
ON
ONLY FOR
SPECIAL
CONFIG.
KNEE
LAM OFF
65Hz
LAM
OFF
LAM
MODE 2
LAM
MODE 1
LAM
OFF
LAM
MODE 2
LAM
MODE 1
50Hz
EXT.FREQ.
SET.
60Hz
0
5
6
9
8
1
2
3
4
SERIES
LSA
49.1/ 50.2
7000/ 8000
SERIES
LSA
49.1/ 50.2
7000
/8000
SERIES
LSA
46.2/ 47.2
5000/ 6000
SERIES
LSA
46.2/ 47.2
5000
/6000
VOLTAGE 320V ~ 530V
VOLTAGE 80V ~ 320V
2
3
0
1
RAPIDE
FAST
RAPIDE
FAST
NORMAL
NORMAL
NORMAL
NORMAL
2
3
0
1
0
9
8
7
6
5
4
3
2
1
0
3
2
1
0
3
2
1
SHUNT / AREP
PMG
LEDS
USC
Installation & maintenance manual :
www.leroy-somer.com
T1
T2 T3
T4
T5
T6
Varistor
5+
6-
T7
T8 T9
T10
T11
T12
X2
Z1
Z2
X1
P1
P2
P3
P4
AREP SYSTEM
Field
Armature
Aux. windings
10 Yellow
11 Red
9 Green
12 Black
10 Yellow 11 Red
9 Green
12 Black
STATOR : 6 wires ( T1 à T6) STATOR : 12 wires ( T1 à T12)
Voltage
Stability
Excitation
Quad droop
MAIN FIELD
CALL US TODAY 1-888-POWER-58
REQUEST A QUOTE
parts@genpowerusa.com
SHOP ONLINE
www.dieselgeneratorusa.com
6
2010.03 / d
LEROY-SOMER
Installation and maintenance
R 450 M & T
A.V.R.
4342 en -
2.2 - PMG excitation system
With PMG excitation, a permanent magnet generator (PMG) added to the alternator supplies the AVR with voltage which is independent of the main alternator winding. These two excitation principles provide the machine with a short-circuit current overload capacity of 3 IN for 10 s.
The AVR monitors the alternator output voltage by adjusting the excitation current. The rotating switch should be in the PMG position (see 3.2.3).
R 450 T
VOI R NO TICE
SEE NOT ICE
U V W
DETECT. 3 PH
3 PH. SENSING
VOLT. STAB. I EXC
STAT.
FUSIBLES / FUSES
F- X2 Z1 F+ Z2 X1
1k
S1 S2
50 Hz 60 Hz
EXT FREQ SETTING
7
LAM
OFF
LAM
ON
ONLY FOR
SPECIAL
CONFIG.
KNEE
LAM OFF
65Hz
LAM
OFF
LAM
MODE 2
LAM
MODE 1
LAM
OFF
LAM
MODE 2
LAM
MODE 1
50Hz
EXT.FREQ.
SET.
60Hz
0
5
6
9
8
1
2
3
4
SERIES
LSA
49.1/ 50.2
7000/ 8000
SERIES
LSA
49.1/ 50.2
7000
/8000
SERIES
LSA
46.2/ 47.2
5000/ 6000
SERIES
LSA
46.2/ 47.2
5000
/6000
VOLTAGE 320V ~ 530V
VOLTAGE 80V ~ 320V
2
3
0
1
RAPIDE
FAST
RAPIDE
FAST
NORMAL
NORMAL
NORMAL
NORMAL
2
3
0
1
0
9
8
7
6
5
4
3
2
1
0
3
2
1
0
3
2
1
SHUNT / AREP
PMG
LEDS
USC
Installation & maintenance manual :
www.leroy-somer.com
PMG SYSTEM
PMG
T1
T2 T3
T4
T5
T6
Varistor
5+
6-
14
14
15
15
16
16
T7
T8 T9
T10
T11
T12
P1
P2
P3
P4
Field
Armature
STATOR : 6 wires ( T1 à T6) STATOR : 12 wires ( T1 à T12)
Voltage
Stability
Excitation
Quad droop
MAIN FIELD
CALL US TODAY 1-888-POWER-58
REQUEST A QUOTE
parts@genpowerusa.com
SHOP ONLINE
www.dieselgeneratorusa.com
Loading...
+ 14 hidden pages