1 About this documentation 5. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1.1 Document history 6. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1.2 Conventions used 6. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1.3 Terminology used 6. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1.4 Notes used 7. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2 Safety instructions 8. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2.1 General safety instructions for drive components 8. . . . . . . . . . . . . . . . . . . . . . . . . . .
2.2 Application as directed 12. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2.3 Foreseeable misuse 13. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2.4 Residual hazards 14. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3 Product description 15. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3.1 Important notes 15. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3.2 Identification 16. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3.2.1 Nameplate 16. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3.2.2 Gearbox code 18. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4 Mechanical installation 19. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4.1 Important notes 19. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4.2 Transport 19. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4.3 Preparation 21. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4.3.1 General information about the assembly of drive systems 22. . . . . . . . . . .
4.3.2 Gearboxes with breathers 23. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4.3.3 Gearbox with compensation container
(preferably for mounting pos. "C") 24. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4.3.4 Mounting the gearboxes 25. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4.3.5 Maximum permissible load at the motor adapter 26. . . . . . . . . . . . . . . . . .
4.3.6 Mounting of motors to gearboxes with an adapter and a
flexible coupling 28. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4.3.7 Coupling hubs 30. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4.3.8 Mounting of motors to gearboxes with a short adapter with a
plug−in hollow shaft with a keyway (drive−end version B or H) 33. . . . . . . .
4.3.9 Attachment of gearboxes with hollow shafts and keyway 34. . . . . . . . . . .
4.3.10 Mounting the shrink disc with a rotating cover 38. . . . . . . . . . . . . . . . . . . .
4.3.11 Mounting the fixed cover 41. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4.3.12 Mounting the hoseproof hollow shaft cover 42. . . . . . . . . . . . . . . . . . . . . .
4.3.13 Torque plate assembly 43. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
5 Electrical installation 44. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
5.1 Motor connection 44. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
5.2 Motor options 44. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Lenze ¯ MA 12.0014 ¯ 5.1
3
Contentsi
6 Commissioning and operation 45. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
6.1 Important notes 45. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
6.2 Before switching on 45. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
6.3 Initial commissioning 45. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
6.4 During operation 46. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
7 Maintenance 47. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
7.1 Important notes 47. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
7.2 Maintenance intervals 47. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
7.3 Maintenance operations 49. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
7.3.1 Position of the lubricant monitoring elements 50. . . . . . . . . . . . . . . . . . . .
7.3.2 Table of lubricants 58. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
7.3.3 Checking the oil level 59. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
7.3.4 Changing the oil 62. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
7.3.5 Lubricate roller bearings 63. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
7.3.6 Drain condensation 64. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
7.4 Repair 65. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
8 Troubleshooting and fault elimination 66. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4
Lenze ¯ MA 12.0014 ¯ 5.1
About this documentation 1

1 About this documentation

Contents
¯ This documentation serves for safety−relevant operations on and with the
gearboxes. It contains safety instructions which must be observed.
¯ All personnel working on and with the gearboxes must have the documentation
available during the work and observe the information and notes relevant for them.
¯ The documentation must always be complete and in a perfectly readable state.
¯ The information in this documentation can be supplemented by further
documents, if necessary, e.g. information regarding the motors mounted, additional components on the gearbox or motor, or with regard to gearboxes and motors in ATEX design.
Target group
This documentation is directed at qualified skilled personnel according to IEC 60364.
Qualified skilled personnel are persons who have the required qualifications to carry out all activities involved in installing, mounting, commissioning, and operating the product.
I Tip!
Information and tools concerning the Lenze products can be found in the download area at
www.lenze.com
Lenze ¯ MA 12.0014 ¯ 5.1
5
1
About this documentation
Document history

1.1 Document history

Material number Version Description
13457390 1.0 02/2014 TD29 First edition for the pilot series
.Xqô 5.1 09/2018 TD29 "Maintenance" chapter: g500−B240 − lubricated for
.Xqô 5.1 09/2018 TD29 Complete revision including the cast iron gearboxes
13535365 4.0 05/2017 TD09 Drawing exchanged in the chapter "Disassembly of
13553160
.Xqô 5.1 09/2018 TD29 Error corrections
5.0 06/2018 TD15 Array of products extended
life Table new: load carrying capacity of the eye bolt
gearbox with hollow shaft" Auxiliary tool table supplemented Important note corrected in the Maintenance chapter Ambient temperatures changed in the lubricant table

1.2 Conventions used

This documentation uses the following conventions to distinguish different types of information:
Type of information Writing Example/notes
Numeric notation Decimal Standard notation Example: 1234 Decimal separator Point The decimal point is always used.
Icons Page reference
Documentation reference
Wildcard
^
,
L
For example: 1234.56
Reference to another page with additional information
For instance: Reference to another documentation with
additional information Example: Wildcard for options, selection data
^ 16 = see page 16
, EDKxxx = see EDKxxx documentation

1.3 Terminology used

Term In the following text used for
Gearboxes Gearboxes of the g500 product family
Drive system Drive systems with g500 gearboxes and other Lenze drive
components
6
Lenze ¯ MA 12.0014 ¯ 5.1
About this documentation

1.4 Notes used

The following pictographs and signal words are used in this documentation to indicate dangers and important information:
Safety instructions
Layout of the safety instructions:
} Danger!
(characterises the type and severity of danger)
Note
(describes the danger and gives information about how to prevent dangerous situations)
Pictograph and signal word Meaning
Danger of personal injury through dangerous electrical voltage
{ Danger!
} Danger!
( Stop!
Reference to an imminent danger that may result in death or serious personal injury if the corresponding measures are not taken.
Danger of personal injury through a general source of danger
Reference to an imminent danger that may result in death or serious personal injury if the corresponding measures are not taken.
Danger of property damage
Reference to a possible danger that may result in property damage if the corresponding measures are not taken.
1
Notes used
Application notes
Pictograph and signal word Meaning
) Note! I Tip! ,
Important note to ensure trouble−free operation
Useful tip for easy handling
Reference to another document
Lenze ¯ MA 12.0014 ¯ 5.1
7
2

2 Safety instructions

2.1 General safety instructions for drive components

(in compliance with Low−Voltage Directive 2014/35/EU)
At the time of dispatch, the drive components are in line with the latest state of the art and can be regarded as operationally safe.
Scope
The following general safety instructions apply to all Lenze drive and automation components.
The product−specific safety and application notes given in this documentation must be observed!
General hazards
Safety instructions
General safety instructions for drive components
} Danger!
Disregarding the following basic safety measures may lead to severe personal injury and damage to material assets!
¯ Lenze drive and automation components ...
... must only be used for the intended purpose. ... must never be operated if damaged. ... must never be subjected to technical modifications. ... must never be operated unless completely assembled. ... must never be operated without the covers/guards. ... can − depending on their degree of protection − have live, movable or rotating parts
during or after operation. Surfaces can be hot.
... must not be actuated if the drive system shows vibration accelerations > 2g (20m/s
... must not be actuated in the resonance range of a system or the Lenze drive system.
¯ All specifications of the corresponding enclosed documentation must be
observed. This is vital for safe and trouble−free operation and for achieving the specified
product features.
¯ Only qualified skilled personnel are permitted to work with or on Lenze drive and
automation components. According to IEC 60364 or CENELEC HD 384, these are persons ... ... who are familiar with the installation, assembly, commissioning and operation of
the product, ... possess the appropriate qualifications for their work, ... and are acquainted with and can apply all the accident prevent regulations,
directives and laws applicable at the place of use.
2
).
8
Lenze ¯ MA 12.0014 ¯ 5.1
Safety instructions
General safety instructions for drive components
Temperatures
The permissible temperature range is determined by the following:
¯ The lubricant specifications in connection with the expected oil temperatures in
operation (see chapter 7.2 and nameplate).
¯ The thermal class of the motor considering the motor temperature expected
during operation (see nameplate and/or operating instructions of the motor).
¯ Protect geared motors against direct solar radiation. Avoid heat concentration
beneath covers.
The operating temperature is determined by the power loss, the ambient temperature and the cooling system!
( Stop!
With mineral oil, the upper temperature limit for continuous operation is 80°C, with synthetic oil and shaft sealing rings made of FP (Viton) it is 100°C. If these temperatures are exceeded, measures are necessary to reduce the temperature, ( 66).
2
} Danger!
Depending on the operating conditions, surfaces may be hot, provide protection against accidental contact.
Ambient media
¯ Gearboxes are protected against dust and spray water.
¯ Motors according to their enclosure (see nameplate and/or operating instructions
for the motor).
¯ Ambient media − especially chemically aggressive − can destroy shaft seals and
coatings (plastic). Abrasive media endanger shaft seals.
¯ The installation site of the drive must be free of shocks and vibration.
¯ Protect geared motors against direct solar radiation. Avoid heat concentration
beneath covers.
¯ Dirt of dust deposits impede the heat dissipation (cooling).
Transport
Before transport
¯ check that all component parts are safely mounted;
¯ check that all component parts with a loose fastening are secured or removed;
¯ tighten all transport aids (eye bolts or support plates).
Use an appropriate means of transport and lifting equipment! ( 19)
Lenze ¯ MA 12.0014 ¯ 5.1
9
2
Storage
If you do not install the gearbox immediately, provide for proper storage conditions.
¯ Generally
¯ Up to one year:
Safety instructions
General safety instructions for drive components
Store gearboxes indoors in a dry, clean (low−dust) and sunlight−protected
environment.
The storage location must be free from vibrations and shocks (V
in order to prevent roller bearing standstill damage.
Temperature changes with condensate formation are to be avoided.Do not activate ventilation unit, in order to prevent air exchange with the
ambient air.
Store gearboxes with a ventilation unit with the vent plug on top.Shafts and uncoated surfaces are delivered in a protected against rust status.
Aftertreatment is required where the corrosion protection has been damaged.
Remove the plug for motors with condensation drain holes (option)( 21).
< 0.2 mm/s)
eff
¯ More than one year, up to two years:
Apply a long−term corrosion preventive (e.g. Anticorit BW 366 from the Fuchs
company) to the shafts and uncoated surfaces before storing the motor away.
Install gearbox in mounting position A.Fill gearbox up to the top vent hole / oil hole with the oil grade specified (see
nameplate). Then mount the locking screw and ventilation unit (do not activate) again.
Corrosion protection
Lenze offers paints with different resistance characteristics for drive systems. Since the resistance may be reduced when the paint coat is damaged, defects in paint work (e.g. through transport or assembly) must be removed professionally to reach the required corrosion resistance.
) Note!
Increased surface and corrosion protection can be achieved by using adapted coating systems.
Mechanical installation
¯ Provide for careful handling and avoid mechanical overload. During handling
neither bend components, nor change the insulation distances.
10
Lenze ¯ MA 12.0014 ¯ 5.1
Safety instructions
General safety instructions for drive components
Electrical installation
¯ Carry out the electrical installation according to the relevant regulations (e. g.
cable cross−sections, fusing, connection to the PE conductor). Additional notes are included in the documentation.
¯ The Instructions contain notes concerning wiring according to EMC regulations
(shielding, earthing, filters and cable routing). The compliance with limit values required by the EMC legislation is the responsibility of the manufacturer of the machine or system.
Warning: The inverters are automation components which can be used in industrial environment according to EN 61000−6−4. These products may cause radio interference in residential areas. If this happens, the operator may need to take appropriate action.
¯ Only plug in or remove pluggable terminals in the deenergised state!
Commissioning
¯ If required, you have to equip the system with additional monitoring and
protective devices in accordance with the respective valid safety regulations (e. g. law on technical equipment, regulations for the prevention of accidents).
2
¯ Before commissioning remove transport locking devices and keep them for later
transports.
Geared motors for deep−freeze applications
¯ Geared motors for deep−freeze applications are specially optimised to operation
at very low temperatures. Observe that for operation outside the temperature range specified (e.g. during commissioning) increased wear or even failures may occur.
¯ We recommend loading the gearbox with a maximum of 50 % of the rated output
torque if it is outside the specified temperature range during commissioning.
Disposal
Sort individual parts according to their properties. Dispose of them as specified by the current national regulations.
Lenze ¯ MA 12.0014 ¯ 5.1
11
2

2.2 Application as directed

All products which this documentation applies to are no household appliances but are exclusively intended as components for re−utilisation for commercial use or professional use in terms of IEC/EN 61000−3−2. They meet the requirements of the Low−Voltage Directive 2014/35/EU and the requirements of the harmonised standards of the IEC/EN 60034 series.
Only use the products under the operating conditions and power limits specified in this documentation.
Do not use the brakes installed as fail−safe brakes. It cannot be ruled out that the braking torque is reduced by disruptive factors which cannot be influenced.
¯ Drives
Any other use shall be deemed inappropriate!
Safety instructions
Application as directed
... must only be operated under the operating conditions and power limits
specified in this documentation.
... comply with the protection requirements of the EU Low−Voltage Directive.
12
Lenze ¯ MA 12.0014 ¯ 5.1

2.3 Foreseeable misuse

Impermissible applications:
¯ In a potentially explosive atmosphere
Exception: special ATEX design
¯ In aggressive environments (acids, gases, vapours, dusts, or oils).
¯ Under water or in liquids
¯ Under radiation
Safety instructions
Foreseeable misuse
2
Lenze ¯ MA 12.0014 ¯ 5.1
13
2

2.4 Residual hazards

Protection of persons
¯ Risk of burns!
Safety instructions
Residual hazards
Hot surfaces up to 140 °C during operation! Provide protection against contact.
¯ Highfrequency voltages can be capacitively transferred to the motor housing
through the inverter supply.
Earth motor housing carefully.
¯ Risk of injury due to rotating shaft!
Before working on the drive system, ensure that the motor is at a standstill.
¯ Danger of unintentional starting or electrical shocks!
Connections must only be made when the equipment is deenergised and the
motor is at standstill.
Installed brakes are no fail−safe brakes.
¯ Dangerous voltages at the power terminals, even if the plug is removed: residual
voltage >60 V!
Motor protection
¯ Installed thermal detectors are no full protection for the machine.
If required, limit the maximum current, parameterise the controller such that it
will be switched off after some seconds of operation with I > I there is the danger of blocking.
, especially if
N
Installed overload protection does not prevent an overload under any
conditions.
¯ Installed brakes are no fail−safe brakes.
The torque can be reduced due to disruptive factors that cannot be influenced,
e.g. by ingressing oil due to a defect shaft sealing ring on the A side.
¯ Fuses are no motor protection.
Use current−dependent motor protection switches at average operating
frequency.
Use installed thermal detectors at high operating frequency.
¯ In the case of permanent−magnet motors, too high torques cause
demagnetisation.
The maximum torques according to catalogue must not be exceeded.
¯ If deviations from normal operation occur, e.g. increased temperature, noise,
vibration, determine the cause and, if necessary, contact the manufacturer. If in doubt, switch off the motor.
¯ Design with plug:
Never disconnect plug when energised! Otherwise, the plug can be destroyed.Switch off power supply and inhibit controller prior to disconnecting the plug.
Fire protection
¯ Fire hazard
Prevent contact with flammable substances.
14
Lenze ¯ MA 12.0014 ¯ 5.1

3 Product description

3.1 Important notes

¯ The most important technical data is given on the nameplate.
¯ The product catalogues contain further technical data.
Product description
Important notes
3
Lenze ¯ MA 12.0014 ¯ 5.1
15
3
Product description
Identification Nameplate

3.2 Identification

3.2.1 Nameplate

Geared motor with a directly mounted motor (layout A)
L
2 3 4
5.1
5.3 6
8.1 9
10.2 11
8.2
7.1
1
21
18 17
5.2
5.4
7.2
8.3
10.3
15
Hz
kW
V
A
r/min
h % cos j
C86
20.1
16.1
16.2
16.4
16.4
16.5
16.5
16.3
16.7
16.6 22
Geared motor with a directly mounted motor (layout B, with QR code)
L
2
14.1 3 4
5.1
5.3
6
8.1
8.2
20.1 11
10.2
9
1
5.4
7.1
8.3
10.3
21
5.2 30
7.2
33.1
43
14.3 18
17
33.2
15
r/min
h %
cos j
C86
13
Hz
16.1
16.2
kW
16.4
16.4
16.5
16.5
16.3
16.7
16.6 22
23
V
A
26
15
19 23 13
14.1
14.2
14.3 27
14.2
Gearbox with motor adapter
L
3
5.1 11
1
6
10.2
18
5.4
5.3
7.2
10.3
30
20.1
17
27
4
5.2
7.1
Three−phase AC motor for motor adapter
L
2 4 21
8.1 9
10.2 11
8.2
14.2
10.3
1
14.1
23
15
26
22
13
8.3
14.3 27
20.1 18
Hz
kW
r/min
V
A
cos j
h %
16.1
16.2
16.3
*
-
*
-
16.4
16.4
16.5
16.5
16.6
16.7
16
Lenze ¯ MA 12.0014 ¯ 5.1
Pos. Contents
1 Manufacturer / production location 2 Type of motor / standard 3 Gearbox type 4 Motor type 5 Technical data 5 5.1 Ratio 5 5.2 Rated torque 5 5.3 Rated speed 5 5.4 Rated frequency 5 5.5 Rated voltage 5 5.6 Rated current 5 5.7 Maximum current 5 5.8 Rated power [kW] 5 5.9 Rated power [HP] 5 5.10 Continuous standstill torque 6 Position of system modules / mounting position 7 Lubricant details 7 7.1 Lubricant amount 7 7.2 Lubricant type 8 Brake data 8 8.1 Type 8 8.2 AC/DC brake voltage 8 8.3 Braking torque, electrical power input 9 Feedback / pulse encoder or resolver data 10 Production data 10 10.2 Material number 10 10.3 Serial number 11 Bar code 13 Information with regard to the operating mode 14 Additional motor specifications 14 14.1 Temperature class 14 14.2 Enclosure 14 14.3 Motor protection 15 Applicable conformities, approvals and certificates 16 Rated data for various frequencies 16 16.1 Hz = frequency 16 16.2 kW = motor power 16 16.3 rpm = motor speed 16 16.4 V = motor voltage 16 16.5 A = motor current 16 16.6 cos j = motor power factor 16 16.7 h = motor efficiency: at a rated power of 100% 17 Application factor / load capacity 18 Year of manufacture / week of manufacture 19 UL file number 20 Customer data 20 20.1 Additional customer data 21 UL category (e.g. inverter duty motor) 22 C86 = motor code for inverter parameterisation (code 0086) 23 Efficiency class 26 CC number Department of Energy (optional) 27 Permissible ambient temperature (e.g. Ta £ 40°C) 30 Weight 33 Encoder data
33.1 Encoder type
33.2 Encoder voltage
43 Internal key: QR code
Product description
Identification
Nameplate
3
Lenze ¯ MA 12.0014 ¯ 5.1
17
3
Product description
Gearbox code

3.2.2 Gearbox code

Example G 50 A B 045 M H B R 2 N 2E Meaning Variant Gearbox code
Product family G 50 Generation A
B
Gearbox type Bevel gearbox B Output torque 45 Nm 045
110 Nm 111 240 Nm 124
450 Nm 145 600 Nm 160 820 Nm 182 1500 Nm 215
2700 Nm 227 4300 Nm 243 8000 Nm 280 13000 Nm 313
20000 Nm 320
Type of construction Geared motor M
Gearbox N
Shaft type Solid shaft with featherkey V
Hollow shaft with keyway H Hollow shaft with shrink disk S
Housing type Foot mounting + centering A
Flange mounting Without flange R
Number of stages 2−stage 2
Drive size Without adapter (integrated motor) C
Foot mounting B Centering C
Flange with through holes K
3−stage 3
NEMA adapter with a jaw coupling with a keyway
NEMA adapter with a plug−in hollow shaft with a keyway
IEC adapter with a plug−in hollow shaft with a keyway
IEC adapter with a jaw coupling N
IEC adapter with a jaw coupling with a keyway
A
00 ...
B
82
H
1A ... 2K
T
18
Lenze ¯ MA 12.0014 ¯ 5.1

4 Mechanical installation

1.
2.

4.1 Important notes

¯ Use load carrying equipment for transport! ¯ Before the transport
check that all components are safely mounted,fasten all transport aids (eye bolts or support plates).
} Danger!
Danger due to toppling or falling loads!
¯ The payload of the hoists and load handling devices must at least
correspond to the weight of the load. ¯ Secure the load handling device so that it won’t slip from its position. ¯ The load must be secured in such a way that it cannot topple or fall
down. ¯ Do not stay under a pending load!
Mechanical installation
Important notes
4

4.2 Transport

} Danger!
The motors attached to the gearbox are partially equipped with eyebolts. They are exclusively determined for mounting/dismounting the motor to the gearbox and must not be used for the complete geared motor!
The position of the transport holes can be gathered from the illustrations shown in the following. As a standard, the G50BB145 ... G50BB243 size gearbox is provided with transport holes for eye bolts complying with DIN 580 in the gearbox cover. The eye bolt is not included in the scope of supply!
For the smaller drives with solid shafts, the output shaft thread can be used or the drive is transported using a securing rope. The rope should be wrapped around the round area between the motor−gearbox interface.
The gearboxes of sizes G50BB280 ... G50BB320 can be lifted at the ear that is cast on to the housing.
G50A0B45 ... G50BB124 G50BB145 ... G50BB243 G50BB280 ... G50BB320
Fig. 1 Positioning of the eye bolt for transporting the complete drive system
Lenze ¯ MA 12.0014 ¯ 5.1
19
4
Mechanical installation
Transport
) Note!
As standard, threads are delivered with plug screws. The plug can be easily removed, e.g. by using a screwdriver blade. For the thread size and load carrying capacity of the eye bolt, please see Tab. 1.
Eye bolt position
£45°
£45°
Tab. 1 Load carrying capacity of each eye bolt in kg
M6 M8 M10 M12 M16 M20 M24
80 140 230 340 700 1200 1800
−−−−− 100 170 240 500 860 1290
−−−−− 70 115 170 350 600 900
} Danger!
Completely screw in transport aids (such as eye bolts or bearing plates), they must be flat and applied over their entire surface!
If possible, the transport aids (such as eye bolts or bearing plates) must be stressed vertically in the direction of the screw axis! Angular tension or tension to the sides reduces the payload! Observe the information provided in DIN 580!
Use additional appropriate lifting aids, if required, to achieve a direction of loading which is as vertical as possible (highest payload). Secure lifting aids against shifting!
Thread
( Stop!
Observe load carrying capacity! Standing beneath floating loads is prohibited!
20
Lenze ¯ MA 12.0014 ¯ 5.1
Mechanical installation

4.3 Preparation

¯ Protect shaft sealing rings against contact with solvents!
¯ Thoroughly remove anticorrosion agents from the output shaft and from flange
faces.
¯ Repair paintwork damage.
¯ In some cases, due to lack of space, stud bolts with nuts must be used instead of
head screws. In these cases, contact Lenze, if necessary.
Tighten all screw connections with the torques given and lock them with standard screw locking adhesive!
Thread
M3 M4 M5 M6 M8 M10 M12 M16 M20 M24 M27 M30 M36
Strength Tightening torque [Nm]
4.8 0.7 1.4 2.8 4.8 12 23
8.8 1.3 3.0 5.9 10.1 24.6 48 84 206 415 714 1050 1428 2482
10.9 1.9 4.6 8.6 14.9 36.1 71 123 302 592 1017 1496 2033 3535
Tab. 2 Tightening torques for friction factor m = 0.12; tolerance of the tightening torque ±10 %
Please note: increase the tightening torque by 10% for screwed connections with flat gaskets.
4
Preparation
Correcting the lubricant amount
If the oil quantity in the gearbox has been increased for longtime storage (( 10)), the oil must be drained completely and then must be refilled for the mounting position provided. The following steps must be complied with:
1. Place receptacle under oil drain plug.
2. Remove breathing / oil filler plug.
3. Completely drain lubricant.
4. Screw in oil drain plug.
5. Fill in amount of oil for the mounting position provided (according to nameplate).
6. Screw in ventilation / oil filler plug.
Condensation drain hole
) Note!
Lenze delivers motors with condensation drain holes with sealed condensation drain holes. The holes are sealed with a plastic plug or a locking screw. This does not affect the type of protection and the motor is protected against the ingress of foreign substances during transport and operation. Further information, ( 64).
Lenze ¯ MA 12.0014 ¯ 5.1
21