Lennox Hearth EBVSTNM-B User Manual

Page 1
US
AVERTISSEMENT : Assurez-vous de bien suivre les instructions données dans cette notice pour réduire au minimum le risque d’incindie ou d’explosion ou pour éviter tout dommage matériel, toute blessure ou la mort.
WARNING: If the information in these instructions is not followed exactly, a fire or explosion may result, causing property damage, personal injury, or death.
WARNING /AVERTISSEMENT/AVISO
HOT GLASS WILL
CAUSE BURNS.
DO NOT TOUCH GLASS
UNTIL COOLED
NEVER ALLOW CHILDREN
TO TOUCH GLASS.
UNE SURFACE VITRÉE CHAUDE
PEUT CAUSER DES BRÛLURES.
LAISSER REFROIDIR LA SURFACE
VITRÉE AVANT D'Y TOUCHER.
NE PERMETTEZ JAMAIS À UN ENFANT
DE TOUCHER LA SURFACE VITRÉE.
EL VIDRIO CALIENTE
CAUSARÁ QUEMADURAS.
USTED DEBE NUNCA
TOCAR EL VIDRIO CALIENTE.
LOS NIÑOS DEBEN NUNCA
TOCAR EL VIDRIO.
- Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.
- WHAT TO DO IF YOU SMELL GAS:
• Do not try to light any appliance.
• Do not touch any electrical switch; do not use any
phone in your building.
• Immediately call your gas supplier from a
neighbor’s phone. Follow the gas supplier’s instructions.
• If you cannot reach your gas supplier, call the fire
department.
- Installation and service must be performed by a qualified installer, service agency or the gas supplier.
- Ne pas entreposer ni utilizer d’essence ni d’autres vapeurs ou liquides inflammables dans le voisinage de cet appareil ou de tout autre appareil.
- QUE FAIRE SI VOUS SENTEZ UNE ODEUR DE GAZ :
• Ne pas tenter d’allumer d’appareil.
• Ne touchez à aucan interrupteur. Ne pas vous servir des
téléphones se trouvant dans le bâtiment où vous trouvez.
• Appelez immédiatement votre fournisseur de gaz depuis
un voisin. Suivez les instructions du fournisseur.
• Si vous ne pouvez rejoindre le fournisseur de gaz,
appelez le service des incindies.
- L’installation et l’entretien doivent être assurés par un installateur ou un service d’entretien qualifié ou par le fournisseur de gaz.
OTL Report No. 116-F-07A-5
P/N 875026M Rev. F 04/2013
This manual is part of a set of two supporting this product. Refer to P/N 850025M for Installation Instructions.
Ce manuel est disponible en francais, simplement en faire la demande. Numéro de la pièce 875026CF.
WHAT'S INSIDE
Table of Contents ........................................... 2
Safety and Your Fireplace.................................... 2
FREE Safety Guard Offer (Protects Against Burns) ................. 2
Important Safety Information ................................. 4
Attaching the Safety-in-Operation Warnings ..................... 5
[EN FRANÇAIS] L’information de sûreté importante ............... 3–4
Apposition des mises en garde relatives à la sécurité d’utilisation .... 5
[EN ESPAÑOL] Información importante de seguridad . . . . . . . . . . . . . . 3–4
Colocación de advertencias de seguridad en operación ............ 5
Portland
CARE AND OPERATION INSTRUCTIONS
EBVST & EBVPF B-Vent Gas Fireplaces
MODELS
MILLIVOLT:
EBVSTNM-B EBVPFNM-B
EBVSTPM-B EBVPFPM-B
Decorative Product: Not for use as a heating appliance.
NOTICE: Fireplace is not to be operated by a thermostat.
ELECTRONIC:
EBVSTNE-B EBVPFNE-B
Wait...
DON’T THROW IT AWAY!
This manual contains
important operating
and safety
information.
INSTALLER: Leave this manual with the appliance. CONSUMER: Retain this manual for future reference.
INSTALLATEUR : Laissez cette notice avec l'appareil. CONSOMMATEUR : Conservez cette notice pour consultation ultérieure.
Page 2
Thank you for your purchase. We appreciate your business! Please carefully read and follow all instructions in this manual.
Pay special attention to all warnings and safety information.
Following these safety, care, and operation instructions will help ensure many years of dependable and enjoyable service from your fireplace.
Safety and
Your Fireplace
Register your product online today!
To help us keep you up-to-date on product information and offers, please take a few moments to register your product online at
www.LennoxHearthProducts.com (> Owner Resources > Product Registration).
FREE
The Lennox® SAFETY GUARD protects against
severe burns and injuries by preventing direct contact
To receive your FREE SAFETY GUARD, call 1-800-655-2008, or visit
www.LennoxHearthProducts.com/buying-guide/safety-guard
SAFETY GUARD
with the front glass surface of your fireplace.
Note: Safety Guards may not be available for some
older models that are no longer in production.
OFFER
Table of Contents
Safety and Your Fireplace................................. 2
Important Safety Information .............................. 4
Attaching the Safety-in-Operation Warnings .................. 5
General Information ...................................... 6
Operation/Care of Your Appliance ............................8
Gas Controls Access ......................................8
Variable Flame Adjustment ..................................9
Maintenance ............................................11
Front Glass Enclosure Panel, Removal and Installation ...........12
Install Vermiculite, Embers and Logs .........................13
Burner Flame Appearance/Sooting ...........................16
Burner Flame Adjustments .................................17
Millivolt Appliance Checkout ...............................17
Electronic Appliance Checkout ..............................18
Wiring Diagrams ........................................18
Warranty ..............................................18
Replacement Parts .......................................18
Product Reference Information .............................18
Accessory Components ...................................19
Maintenance Schedule ....................................25
Lighting Instructions – Millivolt .............................26
Lighting Instructions – Electronic ...........................28
Troubleshooting Guide – Millivolt. . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
Troubleshooting Guide – Electronic ..........................31
Replacement Parts List ...................................32
All parts of your Lennox
Hearth Products fireplace
get EXTREMELY HOT!
To prevent severe burns and injuries, install
a screen or physical barrier to prevent direct contact with the glass.
To order a FREE Lennox® SAFETY GUARD for your fireplace, see details at left.
Follow the safety instructions below
and be sure everyone in your household understands this burn hazard:
•The surfaces on your fireplace get EXTREMELY HOT!
•The glass on the front of the fireplace reaches EXTREMELY HIGH temperatures and can cause severe burns if touched.
•Keep children away from an operating fireplace. Closely supervise children in any room where a fireplace is operating to prevent contact with glass.
•Keep clothing, furniture, gasoline, and other flammable liquids away from the fireplace.
•Even after the gas is turned off, fireplace surfaces remain extremely hot.
Be sure to attach the enclosed Safety-in-
Operation Warnings where you turn on your
fireplace, to help remind everyone of the dangers associated with high temperatures (see page 5).
Read Important Safety Information on
page 4.
2
Page 3
[FRENCH] [SPANISH]
La sécurité et
votre foyer
Toutes les parties de votre foyer
Lennox Hearth Products deviennent
EXTRÊMEMENT CHAUDES !
Afin d'éviter de vous brûler gravement ou de
vous blesser, installez une grille ou une barrière physique pour empêcher tout contact direct avec la vitre.
Pour commander un PANNEAU DE PROTECTION Lennox® GRATUIT pour votre foyer, consultez les détails dans la partie gauche.
Suivez les instructions de sécurité ci-dessous
et veillez à ce que tous les membres de votre famille soient conscients du danger de brûlure encouru :
• Les surfaces de votre foyer deviennent EXTRÊMEMENT CHAUDES !
•La vitre située à l'avant du foyer atteint des températures EXTRÊMEMENT ÉLEVÉES et peut causer de graves blessures en cas de contact.
•Tenez les enfants à l'écart du foyer lorsqu'il fonctionne. Surveillez attentivement les enfants dans les pièces où un foyer est utilisé afin d'éviter qu'ils ne soient en contact avec la vitre.
•Tenez tous les vêtements, les meubles, l'essence et tout autre liquide inflammable à l'écart du foyer.
•Même après fermeture du gaz, les surfaces du foyer restent extrêmement chaudes.
Seguridad y
su chimenea
¡Todas las partes de la chimenea
Lennox Hearth Products se ponen
MUY CALIENTES!
Instale una malla o barrera física para evitar
el contacto directo con el vidrio y prevenir las quemaduras y lesiones graves.
Ver los detalles a la izquierda para ordenar un Lennox® SAFETY GUARD GRATIS para su chimenea.
Siga las instrucciones de seguridad a
continuación y asegúrese de que todos en su hogar sepan acerca de este peligro de quemadura:
•¡Las superficies de la chimenea se ponen MUY CALIENTES!
•El vidrio delante de la chimenea alcanza temperaturas EXTREMADAMENTE ALTAS y puede causar quemaduras graves si se toca.
•Mantenga a los niños alejados de la chimenea en funcionamiento. Supervise en forma cercana a los niños en cualquier cuarto donde haya una chimenea funcionando para impedir el contacto con el vidrio.
•Mantenga la ropa, mobiliario, gasolina y otros líquidos inflamables alejados de la chimenea.
•Aún después de haber apagado el gas, las superficies de la chimenea permanecen extremadamente calientes.
Veillez à coller les Étiquettes de mise en garde
relatives à la sécurité d'utilisation à l'endroit
où vous utilisez le foyer, pour rappeler à tous les utilisateurs les dangers liés aux températures élevées (voir page 5).
Lisez la section Informations importantes
relatives à la sécurité, page 4.
Asegúrese de colocar las Etiquetas de
advertencia de seguridad de operación en
el lugar donde enciende la chimenea, para que todos recuerden los peligros asociados con las altas temperaturas (ver la página 5).
Lea la Información importante de seguridad
en la página 4.
3
Page 4
Important Safety Information
L'information de sûreté importante
1. WARNING: Do not operate appliance with the glass front removed, cracked or broken.
2. Do not use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water.
3. Due to high temperatures, the appliance should be located out of traffic and away from furniture and draperies.
4. Children and adults should be alerted to the hazards of high surface temperature and should stay away to avoid burns or clothing ignition.
5. Clothing or other flammable material should not be placed on or near the appliance.
6. Young children should be carefully supervised when they are in the same room as the appliance. Toddlers, young children, and others may be susceptible to accidental contact burns. A physical barrier is recommended if there are at-risk individuals in the house. To restrict access to a fireplace or stove, install an adjustable safety gate to keep toddlers, young children, and other at-risk individuals out of the room and away from hot surfaces.
7. Any safety screen or guard removed for servicing an appliance must be replaced prior to operating the appliance.
8. Installation and repair should be done by a qualified service person. The appliance should be inspected before use and at least annually by a professional service person. More frequent cleaning may be required due to excessive lint from carpeting, bedding material, et cetera. It is imperative that control compartments, burners, and circulating air passageways of the appliance be kept clean. See maintenance instructions on page 11.
1. AVERTISSEMENT. Ne pas utiliser l’appareil si le panneau frontal en verre n’est pas en place, est craqué ou brisé.
2. Ne pas utiliser cet appareil s’il a été plongé, même partiellement, dans l’eau. Appeler un technicien qualifié pour inspecter l’appareil et remplacer toute partie du système de commande et toute commande qui a été plongée dans l’eau.
3. En raison des températures élevées, l’appareil devrait être installé dans un endroit où il y a peu de circulation et loin du mobilier et des tentures.
4. Les enfants et les adultes devraient être informés des dangers que posent les températures de surface élevées et se tenir à distance afin d’éviter des brûlures ou que leurs vêtements ne s’enflamment.
5. On ne devrait pas placer de vêtements ni d’autres matières inflammables sur l’appareil ni à proximité.
6. Les jeunes enfants devraient être surveillés étroitement lorsqu’ils se trouvent dans la même pièce que l’appareil. Les tout petits, les jeunes enfants ou les adultes peuvent subir des brûlures s’ils viennent en contact avec la surface chaude. Il est recommandé d’installer une barrière physique si des personnes à risques habitent la maison. Pour empêcher l’accès à un foyer ou à un poêle, installez une barrière de sécurité ; cette mesure empêchera les tout petits, les jeunes enfants et toute autre personne à risque d’avoir accès à la pièce et aux surfaces chaudes.
7. Tout écran ou protecteur retiré pour permettre l’entretien de l’appareil doit être remis en place avant de mettre l’appareil en marche.
8. L’installation et la réparation devrait être confiées à un technicien qualifié. L’appareil devrait faire l’objet d’une inspection par un technicien professionnel avant d’être utilisé et au moins une fois l’an par la suite. Des nettoyages plus fréquents peuvent être nécessaires si les tapis, la literie, et cetera produisent une quantité importante de poussière. Il est essentiel que les compartiments abritant les commandes, les brûleurs et les conduits de circulation d’air de l’appareil soient tenus propres. Voyez les instructions d’entretien à la
page 11
.
[SPANISH]
Información importante de seguridad
1. ADVERTENCIA: No opere el artefacto con el frente de vidrio quitado, agrietado o roto.
2. No use este artefacto si alguna de sus partes ha estado bajo agua. Llame de inmediato a un técnico de servicio calificado para que inspeccione el artefacto y reemplace cualquier parte del sistema de control y cualquier control de gas que haya estado bajo agua.
3. Debido a las altas temperaturas, el artefacto debe situarse fuera de las áreas de tráfico y lejos del mobiliario y cortinas.
4. Se debe alertar a los niños y adultos sobre los peligros de las altas temperaturas en la superficie y que se mantengan alejados para evitar quemaduras o ignición de la ropa.
5. No debe colocarse ropa u otros materiales inflamables sobre y cerca del artefacto.
4
6. Se debe supervisar de cerca a los niños cuando estén en el mismo cuarto que el artefacto. Los niños pequeños, los jóvenes y otras personas pueden ser susceptibles a quemaduras por contacto accidental. Se recomienda instalar una barrera física si hay personas en riesgo en la casa. Para restringir el acceso a una chimenea o estufa, instale una puerta de seguridad ajustable para mantener a los niños pequeños, jóvenes y otras personas en riesgo fuera del cuarto y lejos de las superficies calientes.
7. Cualquier malla o resguardo de seguridad quitado para dar servicio a un artefacto, debe reinstalarse antes de operar el artefacto.
8. Una persona de servicio competente debe realizar la instalación y reparación. Una persona de servicio profesional debe inspeccionar el artefacto antes de usar al menos una vez por año. Se puede requerir limpieza más frecuente debido a la pelusa excesiva del alfombrado, del material de cobijas, etc. Es imprescindible mantener limpios los compartimientos de control, los quemadores y los pasajes de circulación del aire del artefacto. Ver las instrucciones de mantenimiento en la página 11.
Page 5
HOMEOWNER’S INSTRUCTIONS - ATTACHING SAFETY IN OPERATION WARNINGS
ATTACHING SAFETY IN OPERATION WARNINGS
Your fireplace has been furnished with safety instruc­tion labels that are to be affixed to the operation and control point of the fireplace. A safety instruction label should be affixed to the wall switch plate where the fireplace is turned on and off (See Figure A) and if used on the remote control handheld transmitter (Figure B). The warnings should already have been put in place when the fireplace initial set-up was completed. If they are not affixed at these spots, locate the multi-lingual adhesive labels provided with these instructions and proceed as follows:
1. Locate the wall switch that controls the fireplace (verify the switch operates the fireplace by turn­ing it on and off). Clean the wall switch plate thoroughly to remove any dust and oils. Affix the label to the surface of the plate of the wall switch that controls the fireplace (Figure A). Choose the language primarily spoken in the home.
2. If a remote control is used to control the fireplace, locate the transmitter and clean it thoroughly to remove any dust and oils. Affix the label to the surface of handheld transmitter (Figure B). Choose the language primarily spoken in the home.
3. If you are unable to locate the labels, please call Lennox Hearth Products or your nearest Lennox Hearth Products dealer to receive additional safety instruction labels free of charge.
Cat. No. H8024 Replacement Label Kit
LENNOX HEARTH PRODUCTS 1-800-655-2008
Note: English is red text on clear label. French and Spanish are white text on black label.
APPOSITION DES MISES EN GARDE RELATIVES À LA SÉCURITÉ D’UTILISATION
Votre foyer a été livré avec des étiquettes de sécurité qui doivent être collées à côté des dispositifs de contrôle du foyer. Une étiquette de sécurité devrait être collée sur la plaque de l’interrupteur contrôlant l’allumage du foyer (voir Figure A) et, le cas échéant, sur le boîtier de la télécommande (Figure B). Les mises en garde auraient dû être collées au moment de l’installation initiale du foyer. Si ce n’est pas le cas, prenez les étiquettes adhésives multilingues fournies avec ces instructions et procédez comme suit:
1. Repérez l’interrupteur qui contrôle le foyer (vérifiez que l’interrupteur contrôle le fonctionnement du foyer en le faisant basculer de Marche à Arrêt, et vice-versa). Nettoyez soigneusement la plaque murale de l’interrupteur pour éliminer la poussière et les traces de graisse ou d’huile. Collez l’étiquette sur la surface de la plaque de l’interrupteur mural qui contrôle le foyer (Figure A). Choisissez la langue qui est principalement parlée dans la résidence du propriétaire.
2. Si une télécommande est utilisée pour contrôler le foyer, nettoyez la soigneusement pour éliminer la poussière et les traces de graisse ou d’huile. Collez l’étiquette sur le boîtier de la télécommande (Figure B). Choisissez la langue qui est principale­ment parlée dans la résidence du propriétaire.
3. Si vous ne trouvez pas les étiquettes, veuillez appeler Lennox Hearth Products ou votre distribu­teur Lennox Hearth Products local pour recevoir gratuitement des étiquettes supplémentaires.
Étiquettes de remplacement, n° cat. H8024
LENNOX HEARTH PRODUCTS 1-800-655-2008
Remarque : Le texte anglais est rouge sur un support transparent. Le texte français et espagnol est blanc sur un support noir.
COLOCACIÓN DE ADVERTENCIAS DE SEGURIDAD EN OPERACIÓN
Su chimenea incluye etiquetas de instrucciones de seguridad que deben colocarse en el punto de operación y control de la chimenea. Se debe colocar una etiqueta de instrucciones de seguridad en la placa del interruptor de pared desde el cual se enciende y se apaga la chimenea (ver la Figura A) y en el transmisor de control remoto (Figura B) si se usa. Las advertencias ya deben haberse colocado cuando se completó la instalación inicial de la chimenea. Si no están colocadas en estos lugares, encuentre las etiquetas adhesivas multilingües proporcionadas con estas instrucciones y prosiga de la siguiente manera:
1. Identifique el interruptor de pared que controla la chimenea (verifique que el interruptor opera la chimenea encendiéndola y apagándola). Limpie bien la placa del interruptor de pared para quitar el polvo y aceite. Pegue la etiqueta en la superficie de la placa del interruptor que controla la chimenea (Figura A). Seleccione el idioma que más se habla en la casa.
2. Si se usa un control remoto para controlar la chimenea, encuentre el transmisor y límpielo bien para quitar el polvo y aceite. Pegue la etiqueta en la superficie del transmisor (Figura B). Seleccione el idioma que más se habla en la casa.
3. Si no puede encontrar las etiquetas, sírvase llamar a Lennox Hearth Products o al distribuidor de Lennox Hearth Products más cercano para recibir etiquetas de instrucciones de seguridad adicionales gratuitas.
Juego de etiquetas de repuesto - Nº de cat. H8024
LENNOX HEARTH PRODUCTS 1-800-655-2008
Nota: La etiqueta en inglés es transparente con texto rojo. Las etiquetas en francés y español son negras con texto blanco.
SAFETY LABEL
DIAGRAMS
Illustrations are for example only. Your accessories may be different.
Les illustrations sont par exemple uniquement. Vos accessoires peuvent être différents.
Las ilustraciones son sólo ejemplos. Tu accesorios pueden ser diferentes.
DIAGRAMMES DES ÉTIQUETTES
DE SÉCURITÉ
Figure A
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
DIAGRAMAS DE ETIQUETAS
DE SEGURIDAD
Figure B
5
Page 6
APPLIANCE INSTALLATION, SERVICE, AND MAINTENANCE NOTICES
WARNING: Improper installation, adjustment, alteration, service or maintenance can cause injury or property damage. Refer to the owner’s information manual provided with this appliance. For assistance or additional information consult a qualified installer, service agency or the gas supplier.
AVERTISSEMENT : Une installation, un réglage, une modification, une réparation ou un entretien mal effectué peut causer des dommages matériels ou des blessures. Voir la notice de l’utilisateur qui accompgne l’appareil. Pour de l’aide ou des renseignements supplémentaires, consultez un installateur, un technicien agréé ou le fournisseur de gaz.
Only trim kit(s) supplied by the manufacturer shall be used in the installation of this appliance.
Seules les trousses de garniture fournies par le fabricant doivent être utilisées pour l’installation de cet appareil.
These appliances must not be connected to a chimney or flue serving a separate solid fuel burning appliance.
Draft relief openings must not be covered or blocked.
Any change to this appliance and/or its operating controls is dangerous. Improper installation or use of this appliance can cause serious injury or death from fire, burns, explosion or carbon monoxide poisoning.
CARBON MONOXIDE POISONING: Early signs of carbon monoxide poisoning are similar to the flu with headaches, dizziness and/or nausea. If you have these signs, obtain fresh air immediately. Turn off the gas supply to the appliance and have it serviced by a qualified professional, as it may not be operating correctly. Some people are more affected by carbon monoxide than others, including pregnant women, people with heart or lung disease or anemia, those under the influence of alcohol, and those at high altitudes.
Turn off gas and electrical power to the fireplace and allow it to cool before cleaning or servicing the appliance.
6
APPLIANCE OPERATION NOTICES
Do not operate appliance with the glass front removed, cracked, or broken.
These fireplaces are vented gas appliances. Do not burn wood or other material in these appliances.
This appliance is only for use with the type of gas indicated on rating plate. This appliance is not convertible for use with other gases, unless a certified kit is used.
These appliances are designed to operate on natural gas or propane gas only. The use of other fuels or combinations of fuels will degrade the performance of this system and may be dangerous.
Cet appareil doit être utilisé uniquement avec les types de gaz indiqués sur la plaque signalétique. Ne pas l’utiliser avec d’autres gaz sauf si un kit de conversion certifié est installé.
Provide adequate clearances around air openings and adequate accessibility clearance for service and proper operation. Never obstruct the front or back openings of the appliance.
Do not use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control that has been under water.
These fireplaces are designed as decor­ative appliances and are not intended for use as area heaters. They must not be equipped with wall thermostats or remote controls with thermostat functions.
CAUTION: Hot while in operation. Do not touch. Severe Burns may result. Keep children, clothing furniture, gasoline and other liquids having flammable vapors away.
ATTENTION : L’appareil est chaud lorsqu’il fonctionne. Ne pas toucher l’appareil. Risque de brûlures graves. Surveiller les enfants. Garder les vêtements, les meubles, l’essence ou autres liquides produisant des vapeur inflammables loin de l’appareil.
This appliance uses room air for combustion. It is imperative that provisions for adequate combustion and ventilation air be made. This appliance is NOT designed to and will not operate in a negative pressure. Contact your dealer if you suspect such a situation exists.
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
WARRANTY INFORMATION
Your gas appliance is covered by a limited lifetime warranty. You will find a copy of the warranty accompanying this manual. Please read the warranty to be familiar with its coverage.
Retain this manual. File it with your other documents for future reference.
Failure to comply with the installation and operating instructions provided will result in an improperly installed and operating appliance, voiding its warranty.
Do not attempt to alter or modify the construction of the appliance or its components. Any modification or alteration may void the warranty, certification, and listings of this unit.
NEGATIVE PRESSURE WARNING
WARNING
B-Vent appliances are not designed to operate in negatively pressured environments (pres­sure within the home is less than pressures outside). Significant negatively pressured environ­ments caused by weather, home design, or other devices may impact the operation of these appliances. Negative pres­sures may result in poor flame appearance, sooting, damage to property and/or severe personal injury. Do not operate these appliances in negatively pres­sured environments.
General Information
The fireplace models covered in this manual are b-vented decorative fireplaces designed for residential application.
The Millivolt appliances have a millivolt gas control valve with piezo ignition system. If any optional accessories which require electrical power are being installed, the electrical power must be provided at the time of appliance in­stallation.
The Electronic appliances are designed to operate on either natural or propane gas. An electronic intermittent pilot system provides safe, efficient operation. External electrical power is required to operate these units.
Page 7
These appliances comply with National Safety Standards and are tested and listed by OMNI-Test Laboratories, Inc. (Report No. 116-F-07A-5) to ANSI Z21.50 (in Canada, CSA-2.22), and CAN/CGA-2.17-M91 in both USA and Canada, as vented gas fireplaces.
The Installation must conform to local codes or, in the absence of local codes, with the National Fuel Gas Code, ANSI Z223.1/NFPA 54-latest edition, or the Natural Gas and Propane Installation Code, CAN/CGA B149.1-latest edi­tion. The appliance, when installed, must be electrically grounded in accordance with local codes or, in the absence of local codes, the latest edition of the National Electrical Code, ANSI/NFPA 70, or the Canadian Electrical Code, CSA C22.1 - latest editions.
BTU Input
Millivolt Models - The millivolt appliances are
manually controlled and feature a spark igniter (piezo) that allows the appliance's pilot gas to be lit without the use of matches or batteries. This system provides continued service in the event of a power outage.
Millivolt models come standard with a manu­ally-modulated gas valve; flame appearance and heat output can be controlled at the gas valve. The BTU Input for these appliances is shown in Table 1.
Electronic Models - Electronic models have a fixed rate gas valve. Input of electronic models is shown in Table 1.
Input (BTU) Gas Valves (all models)
All Models Fuel
Type
Millivolt Natural
Millivolt Propane
Input Rate (BTU / HR)
37,500 high
30,000 low
34,000 high
27,000 low
Electronic Natural 37,500
Electronic Propane 34,000
Table 1
Gas Pressure - All Models
Tables 2 and 3 show the appliances' inlet and manifold gas pressure requirements:
Inlet Gas Supply Pressure
(all models)
Fuel # Minimum Maximum
Natural Gas
Propane
4.5" WC
(1.12 kPa)
11.0" WC
(2.74 kPa)
10.5" WC
(2.62 kPa)
13.0" WC
(3.24 kPa)
Table 2
Manifold Gas Supply Pressure
(all models)
Fuel # Low High
Natural
Gas
Propane
(Lo) 2.2" WC
(0.55 kPa)
(Lo) 6.3" WC
(1.57 kPa)
(Hi) 3.5" WC
(0.87 kPa)
(Hi) 10.0" WC
(2.49 kPa)
Table 3
Test gauge connections are provided on the front of the millivolt and electronic gas control valve (identified IN for the inlet and OUT for the manifold side). The control valves have a 3/8" (10mm) NPT thread inlet and outlet side of the valve (refer to Figures 2 and 3).
Propane tanks are at pressures that will cause damage to valve components. Verify that the tanks have step down regulators to reduce the pressure to safe levels.
The appliance and its appliance main gas valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess of 1/2 psi (3.5 kPa).
The appliance must be isolated from the gas supply piping system by closing its equipment shutoff valve during any pressure testing of the gas supply piping system at test pres­sures equal to or less than 1/2 psi (3.5 kPa).
Orifice Sizes - Sea Level to High Altitude (All Models)
These appliances are tested and approved for installation at elevations of 0-4500 feet (0-1372 meters) above sea level using the standard burner orifice sizes (marked with an "*" in Table 4). For elevations above 4500 feet, contact your gas supplier or qualified service technician.
Deration - At higher elevations, the amount of BTU fuel value delivered must be reduced by either using gas that has been derated by the gas company or by changing the burner orifice to a smaller size as regulated by the local authorities having jurisdiction and by the (USA) National Fuel Gas Code NFPA 54/ANSI Z223.1 - latest edition or, in Canada, the CAN/ CGA-B149.1 codes - latest edition.
Install the appliance according to the regulations of the local authorities having jurisdiction and, in the USA, the National Fuel Gas Code NFPA 54 / ANSI Z223.1 - latest edition or, in Canada, the CAN/CGA-B149.1 - latest edition.
Flame breadth, height and width will diminish 4% for every 1,000 feet of altitude.
Burner Orifice Sizes (all models)
Elevation
Feet (meters)
0-4500
(0-1372)
Table 4
• Part /Cat. Number
Natural
Gas
drill size (inches)
#32 (0.116")
37L82•
* Standard size installed at factory
*
Propane
Gas
drill size (inches)
#50 (0.070")
H4873•
*
In Canada - CAN/CGA-2.17-M91 (R2009)(high altitude): THE CONVERSION SHALL BE CAR­RIED OUT BY A MANUFACTURER’S AUTHO­RIZED REPRESENTATIVE, IN ACCORDANCE WITH THE REQUIREMENTS OF THE MANU­FACTURER, PROVINCIAL OR TERRITORIAL AUTHORITIES HAVING JURISDICTION AND IN ACCORDANCE WITH THE REQUIREMENTS OF THE CAN/CGA-B149.1 OR CAN/CGA-B149.2 INSTALLATION CODES.
Burn-in Period
During the first few fires of this appliance there will be some odor due to the curing of the paint and burning off of lubricants used in the manufacturing process. Depending on your use, the burn-in period may take a few hours or a few days.
KEEP YOUR HOUSE WELL VENTILATED DURING THE CURING PROCESS. THE ODOR AND HAZE EMITTED DURING THE CURING PROCESS CAN BE QUITE NOTICEABLE AND MAY SET OFF A SMOKE DETECTOR.
A white film may develop on the glass front during the first few fires as part of the curing process. The glass should be kept clean during the first two weeks of use to prevent the film from baking on (making it very difficult to remove). See Cleaning Glass on Page 11.
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
7
Page 8
OPERATION AND CARE OF YOUR APPLIANCE
Piezo Igniter
Gas Valve
Modesty Panel
Control
Compartment
Access panel
ON/OFF Switch
Hinge Pin
WARNING
Young children should be carefully supervised when they are in the same room as the appliance. Toddlers, young children and others may be susceptible to accidental contact burns. A physical barrier is recommended if there are at risk individuals in the house. To restrict access to a fireplace or stove, install an adjustable safety gate to keep toddlers, young children and other at risk individuals out of the room and away from hot surfaces.
AVERTISSEMENT
Les jeunes enfants devraient être surveillés étroitement lorsqu’ils se trou­vent dans la même pièce que l’appareil. Les tout petits, les jeunes enfants ou les adultes peuvent subir des brûlures s’ils viennent en contact avec la surface chaude. Il est recommandé d’installer une barrière physique si des personnes à risques habitent la maison. Pour empêcher l’accès à un foyer ou à un poêle, installez une barrière de sécurité; cette mesure empêchera les tout petits, les jeunes enfants et toute autre personne à risque d’avoir accès à la pièce et aux surfaces chaudes.
Refer to Figure 1 for access to the gas control valve. Millivolt appliances will be fitted with the gas control valve shown in Figure 2.
Appliances with electronic systems will be fitted with the electronic valve shown in Figure 3. Familiarize yourself with the gas control valve that your appliance uses.
Millivolt Appliances -
To light millivolt appliances refer to the detailed lighting instructions found on page 26 (English)
and page 27 (French). Millivolt appliance lighting instructions may also be found on the pull out lighting instruction labels attached to the gas control valve.
Millivolt appliances are fitted with an ON/OFF Rocker Switch for appliance ON/OFF control. Refer to Figure 1 for its location. Once the pilot is lighted, the ON/OFF rocker switch will control the appliance ON/OFF operation. To operate: Toggle the switch between its ON and OFF positions.
Gas Controls/Control Compartment Access
The gas controls can be found behind the hinged drop-down panel.
To open the hinged drop-down panel, actuate the spring loaded magnetic catches securing the door. First, gently depress the upper right top corner of the panel until the magnet catch "pops" the door free. Then, gently pulling the panel forward, disengage the left magnet catch and allow the panel to swing down to open.
On millivolt systems, the piezo igniter, Hi/Lo flame adjustment knob, and pilot and main gas ON/OFF control knob are located on the modesty panel. On both millivolt and electronic systems the gas valve is located behind the modesty panel. See Figure 1.
Remove the bottom compartment door by sliding the hinge pin, located at the door’s left side, to the right until it disengages from the left corner post hole. Pull the door diagonally to the left, away from the fireplace.
To ease door closure, depress the catches to place them in their retracted position until they stay there, then close the door.
Operation of millivolt and electronic gas con­trol systems are different. Before lighting and operating your appliance determine if you have a millivolt or electronic appliance.
Control Compartment Access -
Millivolt Control Valve Shown
Figure 1
If your millivolt appliance is equipped with an optional remote wall switch or remote control kit and the pilot is lit, the appliance main burner may be turned on and off with the wall switch or remote control.
Electronic Appliances -
To light electronic appliances refer to the detailed lighting instructions found in both English and French on pages 28 and 29 of these instructions respectively. Electronic
appliance lighting instructions may also be found on the pull out lighting instruction labels attached to the gas control valve. Electronic
appliances are fitted with an ON/OFF Rocker Switch for appliance ON/OFF control. Refer to Figure 1 for its location.
Once the pilot is lighted, the ON/OFF rocker switch will control the appliance ON/OFF opera­tion. To operate: Toggle the switch between its ON and OFF positions.
If your electronic appliance is equipped with an optional remote wall switch or remote control kit the appliance main burner may be turned on and off with the wall switch or remote control.
8
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
Page 9
Variable Flame Height Adjustment
Outside Air Control Lever with Stop Behind
Securing Screw
Outside Air Shutter in the Closed Position
Control Compartment Access Panel
Inlet Pressure Port
Manifold Pressure Port
IN
TPTH TP TH
I
H
L
O
W
P
I
L
O
T
OUT
F
F
O
P
I
L
it
O
T
O
N
SIT Millivolt Gas Valve
Note: The piezo igniter is located on the modesty panel - refer to Figure 1.
Figure 2
Variable Flame Height Adjustment ( Millivolt Appliances only)
All Millivolt appliances are equipped with a variable gas control valve. Flame height for these models may be adjusted through a range between fixed low and high settings, alternately, while the appliance is in operation.
Adjust the flame height as desired after lighting the appliance by rotating the variable adjustment control knob located on the front of the valve (refer to Figure 2). (An extension is provided to this knob so that the adjustment may be made at the modesty panel).
Main Gas
Control Knob
Manifold Pressure Port
Figure 3
ON/OFF Switch
CONTROL
OFF
ON
IGNITER
Honeywell Electronic
Inlet
IN
Pressure Port
PSI
Electronic Gas Control Valve
Gas Valve
Outside Combustion Air Controls
Many appliances are equipped, when installed, with an outside (make-up air) vent system that is designed to provide the appliance with outside make-up air for combustion when in operation. The outside air control lever for the outside air system is standard on all appliances but should not be operated if the complete system is not installed. Refer to Figure 4. When the complete outside air vent system is installed, the installer will remove the securing screw from the combustion air control lever located on the right side of the fireplace opening.
If the securing screw has not been removed and you have reason to believe that you have a complete outside air system, contact your distributor to have your appliance inspected for the presence of the complete system. DO NOT assume that you have this system in place.
Outside Air Control Lever
and Securing Screw Location
(EBVST and EBVPF Units Shown)
Figure 4
9
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
Page 10
Manual-Reset Safety Limit Switch
SAFETY SWITCH LOCATION (EBVST and EBVPF Safety Switch Location Shown)
MANUALLY-RESET SAFETY LIMIT SWITCH
FIREBOX SIDE BAFFLE
FIREBOX SIDE BAFFLE SECURING SCREW
FIREBOX
SIDE WALL
CABINET
SIDE WALL
TOP RADIANT PANEL
AND EYEBROW
BRACKET
SECURING SCREW
SAFETY SWITCH
WARNING
This appliance is equipped with a manual-reset blocked flue safety limit switch. Refer to Figure
Do not operate the shutoff lever unless a complete outside com­bustion air system has been installed with your appliance.
5 for its location. If, during appliance operation, the flame goes out (independently of the burner on/off wall switch), it may be due to the opera­tion of this safety limit switch. First allow the appliance to cool, then reset the safety switch
by pushing the red reset button on it. To open the outside air shutter, open the bottom control access panel, reach into the gap between the firebox bottom and the modesty panel, and pull the outside air control lever all the way out.
A - To access the blocked flue safety switch
when top radiant panel is not covered with
non-combustible material: The outside air shutter should be fully open when the fireplace is in use and completely closed when the fireplace is not being used. Closing it when not in use will prevent outside cold air from entering the dwelling.
1 - Lift up and remove top radiant panel/eye­brow assembly on the control side of unit. 2 - Reach between the cabinet side and the firebox side wall and locate the blocked flue safety switch.
Venting Action and Safety Limit Operation
3 - Push the red reset button on the
switch.
If you suspect that the appliance is not vent­ing properly, or you notice windows fogging or sweating, you may want to conduct the following spillage test:
The appliance should then relight and remain
lit. If this does not occur, turn off the appliance
and call a qualified service technician.
1 - Place unit in its normally-operated condi-
tion, that is, with the glass enclosure panels in place. 2 - Close all doors and windows in the room. Turn on all exhaust fans in the house.
3 - Light the appliance. 4 - Wait 15 minutes. 5 - To check for venting action, start by
holding a smoke producing device within an inch of one edge (side edge, not top or bottom edge) of one glass enclosure panel. The smoke should be drawn toward the edge of the glass enclosure panel. Continue the test by moving the smoke producing device along the entire length of both side-edges of the glass door. Repeat the test for all glass enclosure panels.
6 - If the smoke is not drawn towards the edges of the glass door turn off the appliance and call a qualified service technican.
B - To access the blocked flue safety switch
when top radiant panel is covered with non­combustible material:
NOTE: This procedure should only be performed by a qualified service technician.
1 - Lower bottom hinged panel on the control side of the fireplace. Remove the glass enclo­sure panel as described on page 12. 2 - Remove the side baffle securing screws (5) and then remove the baffle. 3 - Remove the safety switch bracket secur­ing screws (2), and pull the switch/bracket assembly through the side panel slot.
4 - Push the red reset button on the switch. 5 - Reinstall the switch/bracket assembly. 6 - Reinstall the side baffle. 7 - Reinstall front glass door. 8 - Raise the bottom hinged panel.
The appliance should then relight and remain lit. If this does not occur, check unit for a blocked flue condition.
10
Figure 5
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
Page 11
MAINTENANCE (See Maintenance Schedule, Page 25)
Refer to the maintenance schedule for maintenance tasks, procedures, periodicity and by whom they should be performed. Always verify proper opera­tion of the appliance after servicing.
WARNING
Turn off gas and electrical power to the fireplace and allow it to cool before cleaning or servicing the appliance.
CAUTION: Wear gloves and safety glasses for protection while doing required maintenance.
Verify proper operation after servicing. S'assurer que l'appareil fonctionne adé-
quatement une fois l'entretien terminé. Always turn off gas to the pilot (millivolt
appliances) before cleaning. Before re­lighting, refer to the lighting instructions in this manual. Instructions are also found on a pull-out panel located in the control compartment.
Always keep the appliance area clear and free from combustible materials, gasoline and other flammable vapors and liquids.
Inspect Venting System
The appliance and venting system should be thoroughly inspected before initial use and at least annually by a qualified service technician (inspection should include ensuring that venting system is unobstructed and vent components are properly assembled and not damaged).
Homeowner must contact a qualified service technician at once if any abnormal condition is observed.
If the venting system is disassembled for any reason, a qualified service technician should follow vent installation instructions for proper reassembly and proper sealing of the venting system components. However, more frequent periodic inspections and cleanings should be performed by the homeowner.
Cleaning Glass
(see Front Glass Enclosure Panel, Removal and Installation on Page 12).
NOTE: Clean glass after first two weeks of operation (after Burn-In period is over) and then only when necessary and when the fireplace is cool. Wipe surface with a clean, dampened, soft cloth. Follow with a dry, soft towel as desired. Take care not to scratch the glass surface.
IMPORTANT: Do not use abrasive clean-
ers on glass. Never clean the glass when
it is hot.
The viewing glass should be cleaned periodi-
cally to remove any build-up caused from the
following:
• Duringstart-up,itisnormalforcondensa­tion to form on the inside of the glass (this condensation and fog will usually disappear in a few minutes). The moisture can cause lint, dust and other airborne particles to cling to the glass surface.
• Initialcuringofthehightemperaturepaint
and burning off of lubricants used in the manufacturing process may result in a film on the glass.
• Awhitecoatingmayformontheglassasa
result of impurities and minerals in the fuel.
It is recommended that the glass be cleaned two or three times during each year, depending on the circumstances present. The following cleaning solutions are approved for use to clean glass:
•Non-ammoniabasedhouseholdcleaner
•50%-50%mixofwhitevinegarandwater
•Gasreplace/stoveglasscleaner
Inspect Glass Gasket - Visually inspect the gasket on the backside of the glass enclosure panels. The gasket surface must be clean, free of irregularities and seated firmly.
Clean Control Compartment
Keep control compartment clean by vacuuming or brushing at least twice a year. More frequent cleaning may be required due to excessive lint from carpeting, bedding materials, etc. It is important that control compartments, burners and circulating air passageways of the appliance be kept clean.
Clean Logs And Burner
Carefully remove the logs (use care when han­dling the fiber logs, as they become quite fragile after curing). Vacuum out any foreign matter (lint, carbon, etc). on the burner. Ensure the burner ports are “open.” Remove any carbon deposits from the under side of the logs using a vacuum cleaner, or a soft bristled brush (i.e. paint brush).
NOTE: Improper positioning of logs can create carbon build-up and will alter the performance of the appliance.
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
Replacing Logs
If the logs become damaged by accident or improper handling and need replacement, use only the proper replacement logs from manu­facturer (see Pages 14 and 15 for ordering information).
Re-Install Embers and Logs
Carefully follow placement instructions on Pages 13 through 15. All logs should fit onto corresponding pins and/or log stop­pers. This will ensure a proper flame and safe combustion.
Inspect Wiring
Refer to wiring diagrams on Page 18.
CAUTION: Label all wires prior to discon­nection when servicing controls. Wiring errors can cause improper and dangerous operation. Verify proper operation after servicing.
ATTENTION: Au moment de l'entretien des commandes, étiquetez tous les fils avant de les débrancher. Des erreurs de cáblage peuvent entraîner un fonc­tionnement inadéquat et dangereux.
Inspect and clean all wire connections. Ensure that there is no melting or damage. Inspection should include:
• TerminalsattheValve
• OFF/ONSwitch
• (Optional Control Switch)RemoteControl
or Remote Wall Switch Kit
Inspect Burner Flame and Pilot Flame Appearance
Periodically do a visual check of the burner flame and the pilot flame. Ensure that the burner flame appearance resembles the flame shown in Figure 13 and as described in flame Appearance and Sooting on Page 12. Refer to Figures 15 and 16 on Page 13 for more information about the pilot flame appearance. Contact a qualified service technician at once if any abnormal condition is observed.
Small Area Paint Touch-up
Only use a factory supplied paint kit for touch­ups. Paint is available at your local Lennox Hearth Products dealer. Never attempt to paint a hot fireplace.
Do not attempt to repaint the appliance until the finish is completely cured (see Burn-In Period on Page 7). If the sur face later becomes stained or marred, it may be lightly sanded and touched up with spray paint.
11
Page 12
Front Glass Enclosure Panel, Removal
Glass Door Latch
Control Compartment Access Panel and Hinge
Front Glass Enclosure Panel
Firebox Floor
Bottom Vee-flange
Glass Door Frame
Top Flange Glass Door Frame
and Installation
WARNING
• Do not attempt to substitute
the materials used on this door, or replace cracked or broken glass.
•Handlethisglasswithextreme
care! Glass is susceptible to damage – Do not scratch or handle roughly while reinstall­ing the glass door frame.
•Theglassdoor(s)ofthisappli­ance must only be replaced as a complete unit as provided by the manufacturer. Do not attempt to replace broken, cracked or chipped glass separately.
•Donotattempttotouchthefront
enclosure glass with your hands while the fireplace is in use.
WARNING
Do not operate appliance with the glass front removed, cracked or broken.
AVERTISSEMENT
Ne pas utiliser l'appareil si le panneau frontal en verre n'est pas en place, est craqué ou brisé.
WARNING
Any safety screen or guard removed for servicing the appli­ance must be replaced prior to operating the appliance.
AVERTISSEMENT
Tout écran ou protecteur retiré pour permettre l’entretien de l’appareil doit être remis en place avant de mettre l’appareil en marche.
Only doors certified with the appliance shall be used.
Seules des portes certifiées pour cet appareil doivent être utilisées.
WARNING: DO NOT abuse glass door by striking or slamming shut.
These are B-vent appliances. They are designed to operate only when the glass enclosure panels are installed. Generally the glass enclosure panels should not be removed except to gain access to the components within the firebox.
Removing Glass Enclosure Panels
(see Figure 6)
Remove the top louver assembly or radiant panel.
To access the glass door securing latch, first open the lower control compartment door (Figure 6) by pushing in simultaneously the left and right top corners of the door. (The door is hinged at the bottom).
Locate the latch at the top of the control com­partment and disengage them from the door frame bottom vee-flange, pulling down on its handle to open it.
Installing Glass Enclosure Panel
(see Figure 6)
Retrieve the glass door. Visually inspect the gasket on the backside of the frame. Gasket surface must be clean, free of irregularities and seated firmly.
Position the door in front of the firebox opening with the bottom of the door held away from the fireplace (Figure 6). Hook the top flange of the door frame over the top of the firebox frame.
Let the bottom of the door frame swing gently in towards the fireplace ensuring that the gasket seats evenly as the door frame draws shut. Fasten the latch located underneath the firebox floor to the door's vee-flange. Close both the latch securely.
NOTE: When installing the glass door, ensure the spacing on both sides is even and equal.
Figure 6 EBVST SHOWN
12
Remove the bottom compartment door by sliding the hinge pin, located at the door’s left side, to the right until it disengages from the left corner post hole. Pull the door diagonally to the left, away from the fireplace.
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
Page 13
INSTALL VERMICULITE, GLOWING EMBERS AND LOGS
Glowing Embers
NOTE: Turn off all electricity to the appliance before you install vermiculite, embers and logs. DO NOT attempt to install the logs until the appliance installation has been completed, the gas line connected and tested for leaks and the initial burner operation has been checked out.
INSTALLATION STEPS:
READ WARNINGS ON THIS PAGE BEFORE PROCEEDING. FOLLOW THE LOG PLACEMENT INSTRUCTIONS EXACTLY
1. Remove the front glass enclosure panel (see Glass Enclosure Panel
Removal and Installation Instructions, Page 12).
2. Remove the following from firebox; log set, bag of embers and bag of vermiculite. Handle logs carefully to prevent breakage.
3. Ensure the Grate is properly installed in the firebox with the 4 legs of the grate fitting into the 4 dimples on the firebox floor.
4. Placement of Glowing Embers -
Separate the Embers (rockwool) into pieces about the size of a quarter
(see Figure 7). Keep the pieces fluffed up, not matted. Distribute these pieces over the surface of the burner, as shown in Figure 8. Do not use more than is necessary. Ensure that the main burner ports remain uncovered by the ember material.
5. Place Volcanic Stone - Spread volcanic stone evenly over firebox floor.
6. Install Vermiculite - Place some vermiculite on the firebox floor around the grate (the entire bag of vermiculite will NOT be used). See
Figure 8. DO NOT PLACE ANY VERMICULITE ON THE BURNER.
NOTE: This appliance is provided with enough Glowing Embers for
several applications, do not use all that is in a new bag at one time. For best glowing effect, replace the ember material annually. Replacement Glowing Embers are available (order Catalog Number 88L53).
Figure 7
REFERENCE
Firebox Accessories / Parts
Cat. No. Model No. Description
88L53 FGE Bag of Glowing Embers 80L42 FDVS Bag of Decorative Volcanic Stone H6319 ---- Bag of Vermiculite
Figure 8
WARNING
•DONOTattempttoinstallthelogs until the appli­ance installation has been completed, the gas line connected and tested for leaks and the initial burner operation has been checked out.
•Thesizeandpositionofthelog set was engineered to give the appliance a safe, reliable and attrac­tive flame pattern. Any attempt to use a different log set in the fireplace will void the warranty and will result in incomplete combustion, sooting, and poor flame quality.
•Logs get very hot and will remain hot up to one hour after gas supply is turned off. Handle only when logs are cool. Turn off all electricity to the appliance before you install grate, volcanic stone, vermiculite, embers and logs.
• This appliance is not designed to burn wood. Any
attempt to do so could cause irreparable damage to the appliance and prove hazardous to your safety.
• If logs are not installed according to the log
installation instructions, flame impingement and improper combustion could occur and result in soot and/or excessive production of carbon monoxide (CO), a colorless, odorless, toxic gas.
13
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
Page 14
EBVPF AND EBVST LOG PLACEMENT
2
STEP 1
6
4
Log Part Number Description Number
1 Log, Corner 55M18 2 Log, Rear/Left 55M19 3 Log, Front/Left 55M20 4 Log, Rear/Right 55M21 5 Log, Front/Center 55M22 6 Log, Center/Top 55M23
Catalog Number for the entire log set: 55M04
3
5
1
STEP 3
Log (3) Lays Over Logs
3
1 And 2
1
Position Groove At The Bottom Of Log (1) Over The Burner Log Support Bracket
Position The Groove At The Bottom Of Log (1) Over The Grate And Slide It Forward Against The Grate Here
Position Log (2) Over The Grate Bar And Slide It Against The Back
STEP 2
2
Of The Grate Here
Position Groove At The Bottom Of Log (2) Over The Grate Here And Slide It Against The Back Of The Grate
Place Bottom Hole Of Log (3) On Pin In Log (2). Position Grooves At The Bottom Of Log (3) Over The Grate.
1
STEP 4
Position And Slide Log (4) Against The Back Of The Grate
4
Place Log (4) Over The Flat Spot On Log (1) Here
14
Figure 9
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
Page 15
EBVPF AND EBVST LOG PLACEMENT (CONTINUED)
Log Part
2
6
4
Number Description Number
1 Log, Corner 55M18 2 Log, Rear/Left 55M19 3 Log, Front/Left 55M20 4 Log, Rear/Right 55M21 5 Log, Front/Center 55M22 6 Log, Center/Top 55M23
Catalog Number for the entire log set: 55M04
STEP 5
Grate
Assembly
3
5
1
Position Small End Of Log (6) On The Notch Of Log (3) Here
3
Position The Groove In The Back Of Log (3) Against The Grate
Position The Round End Of Log (6)
6
5
Against The Notch Of Log (4) Here. Two Charred Spots Face The Front
Log (5) Sits In Front Of The Grate
4
Rest Log (5) Against The Grate Here
Figure 10
15
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
Page 16
BURNER ADJUSTMENTS
Glowing Embers (Rockwool)
(QUALIFIED TECHNICIANS ONLY)
Flame Appearance and Sooting
Proper flame appearance is a flame which is blue at the base and becomes yellowish-orange
in the body of the flame.
When the appliance is first lit, the entire flame may be blue and will gradually turn yellowish­orange during the first 15 minutes of operation. If the flame remains blue, or if the flame is orange with evidence of sooting (black tip), the air shutter opening may need to be adjusted.
If the air shutter opening is closed too far, sooting may develop. Sooting is indicated by black puffs developing at the tips of very long orange flames. Sooting results in black deposits forming on the logs, appliance inside surfaces and on exterior surfaces adjacent to the vent termination.
Sooting is caused by incomplete combustion in the flames and lack of combustion air enter­ing the air shutter opening. To achieve a warm yellowish-orange flame with an orange body that does not soot, the shutter opening must be adjusted between these two extremes.
Air Shutter Adjustment Guidelines
• Ifthereissmokeorsootpresent,rstcheck
the log set positioning to ensure that the flames are not impinging on any of the logs. If the log set is properly positioned and a sooting condition still exists, then the air shutter opening should be increased.
• Themoreoffsetsin theventsystem,the
larger the air shutter opening will need to be.
• Anapplianceoperatedwiththeairshutter
opened too far, may have flames that appear blue and transparent. These weak, blue and transparent flames are termed anemic.
• Propanemodelsmayexhibitameswhich
candle or appear stringy. If this is present and persists, adjust the air shutter to a more closed position, then operate the appliance for a few more minutes to ensure that the flame normalizes and the flames do not appear sooty.
The following chart is provided to aid you in achieving the correct air shutter adjustment for your installation.
Air Shutter Adjustment Guidelines:
Amount of
Primary Air
If air shutter is closed too far
If air shutter is open too far
Flame
Color
Flame will be orange
Flame will be blue
Air Shutter
Adjustment
Air shutter gap should be increased
Air shutter gap should be decreased
16
Figure 11 - Burner Flame Appearance
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
Page 17
MILLIVOLT
Thermocouple
Hood Igniter Rod
3/8" Min (9 mm)
Thermopile
Pilot Nozzels
ELECTRONIC
Proper Flame
Adjustment
Pilot Nozzle
3/8” to 1/2”
(9 mm to 13 mm)
Ground Electrode
Flame Rod
Hot Surface
Igniter
Burner Flame Adjustments
Air Shutter
Adjusting
Rod
Orifice
Increase Shutter Opening In This
Direction
Decrease Shutter
Opening In This
Direction
Note - Burners are omitted in this view for clarity.
FG
FG
(1
7)
WARNING
Air shutter adjustment should
only be performed by a quali­fied professional service tech­nician.
Ensure glass enclosure panels
are in place and sealed during adjustment.
CAUTION
Soot will be produced if the air shutter is closed too much. Any damage due to sooting, resulting from improperly setting the air shutter, is not covered under the warranty.
• The air shutter door and nearby appliance surfaces are hot. Exercise caution to avoid injury while adjusting flame appearance.
RENRUBNIAM
NITTESRETTUHSYROTCAF
GNITTESRETTUHSYROTCA
NITTESRETTUHSYROTCAF
GNITTESRETTUHSYROTCA
GNITTESRETTUHSYROTCAF
saGlarutaN
sledoM
TSVBE FPVBE
Adjustment Rod Positions (when viewed from above)
sehcni )mm(
61/1)5.1
enaporP
saG
sehcni
)mm(
1(61/
Figure 12
Figure 13
Electronic Appliance Checkout
To light the burner, turn ‘ON’ the unit mounted On/Off switch or the optional control switch. Ensure the igniter lights the pilot. The pilot flame should engulf the flame rod as shown in Figure 14.
1. Refer to Figure 11 for proper flame ap-
pearance. To adjust the flame, rotate the adjustment rod toward the back or toward the front of the fireplace (rod located in the lower control area). Position the air shutter to the factory setting as shown in the table in Figure 12.
2. Light appliance (follow lighting procedure on
lighting label in control compartment or see lighting instructions on Pages 26 through
29).
3. Allow the burner to operate for at least 15
minutes while observing the flame continu­ously to ensure that the proper flame ap­pearance has been achieved. If the following conditions are present, adjust accordingly.
 • Ifameappearsweakorsooty,adjust
the air shutter, incrementally, to a more open position until the proper flame appearance is achieved.
 • If ame remains blue, adjust the air
shutter, incrementally, to a more closed position until the proper flame appear­ance is achieved.
4. Leave the control knob (off/pilot/on) in the
ON position (millivolt appliances) and the burner OFF/ON switch OFF (and remote switches, if applicable).
5. When satisfied that the burner flame appear-
ance is normal, re-install the lower control compartment door.
Millivolt Appliance Checkout
The pilot flame should be steady, not lifting or floating. Flame should be blue in color with traces of orange at the outer edge.
Figure 14
The top 3/8" (10 mm) at the pilot generator (thermopile) and the top 1/8" minimum (tip) of the quick drop out thermocouple should be engulfed in the pilot flame.
The flame should project 1" (25 mm) beyond the hood at all three ports (see Figure 13). Replace logs if removed for pilot inspection.
To light the burner; turn “ON” the control switch and rotate the gas valve control knob counterclockwise to the “ON” position (“ON” will be at the top side of the valve).
17
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
Page 18
WIRING DIAGRAMS
H
I
L
O
W
P
I
L
O
T
O
N
ti
O
F
F
IN
OUT
0.375"
0.375"
0.25" Ø
NOT FOR USE WITH SOLID FUEL
CAUTION:
Hot while in operation. Do not touch. Severe Burns may result. Keep children, clothing, furniture, gasoline and other liquids having flammable vapors away.
CAUTION:
Do not operate the appliance with factory installed refractory panel(s) removed, cracked or broken. Replacement of the factory installed refractory panel(s) should be completed by a licensed or qualified service person.
WARNING:
Improper installation, adjustment, alteration, service or maintenance can cause injury or property damage. Refer to the owner’s information manual provided with this appliance. For assistance or additional information consult a qualified installer, service agency or the gas supplier.
Due to high temperatures, keep children, and furniture away.
Keep burner and control compartment clean. See installation and operating instructions accompanying appliance.
WARNING:
Do not connect 120 V AC to the control valve.
THIS APPLIANCE MUST BE INSTALLED IN ACCORDANCE WITH LOCAL CODES, IF ANY; IF NONE, FOLLOW THE NATIONAL FUEL GAS CODE, ANSI Z223.1, OR NATURAL GAS AND PROPANE INSTALLATION CODE, CSA B149.1.
If not installed, and maintained in accordance with the manufacturer's instructions, this product could expose you to substances in fuel or fuel combustion which are known to the state of California to cause cancer, birth defects, or other reproductive harm.
* For a copy of the homeowner’s care and operation manual, go to www.lennox.com or call 1-800-9-lennox.
B-VENTED APPLIANCES NEED FRESH AIR FOR SAFE OPERATION AND MUST BE INSTALLED SO THERE ARE PROVISIONS FOR ADEQUATE COMBUSTION AND VENTILATION AIR.
DIRECT VENTED APPLIANCES MUST NOT BE OPERATED WITHOUT THE FRONT GLASS PANEL(S) INSTALLED.
DO NOT OPERATE APPLIANCE WITH BROKEN, CRACKED OR MISSING GLASS DOORS OR ENCLOSURE PANEL(S).
ELECTRONIC IGNITION WIRING DIAGRAM
Optional Blower**
Junction Box
Break Off Tab
Junction Box
J-Box Wiring
WITH Optional Blower Switch
J-Box Wiring
WITHOUT Optional Blower Switch
BK W
G
CAV 021
BK W
G
CAV 021
Switch, Unit Mounted On/Off Switch, Wall Thermostat (Direct-Vent Units Only) or Remote Control Switch.
Some models are not approved for use with an optional blower. See Care and Operation manual for approved
Schematic Representation Only
W
GR
BK
BK
R
1. If any of the original wire as supplied must be replaced, use Type AWM
2. 120 VAC, 60 Hz - Less than 3 Amps. CAUTION: label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation. Verify proper
0.375"
0.375"
J-Box Wiring
WITHOUT Optional Blower Switch
Wiring diagrams are provided here for reference purposes only. This information is also provided on schematics attached directly to the appliance on a pullout panel located within the control compartment.
CAUTION: LABEL ALL WIRES PRIOR TO DISCONNECTION WHEN SERVICING CONTROLS. WIRING ERRORS CAN CAUSE IMPROPER AND DANGEROUS APPLIANCE OPERATION.
ATTENTION: AU MOMENT DE L'ENTRETIEN DES COMMANDES, ÉTIQUETEZ TOUS LES FILS AVANT DE LES DÉBRANCHER. DES ERREURS DE CÁBLAGE PEU-VENT ENTRAÎNER UN FONCTIONNEMENT INADÉQUAT ET DANGEREUX.
THERMOPILE
GAS CONTROL VALVE
TERMINALS
HIGH LIMIT SWITCH
CONTROL SWITCH*
If any of the original wire as supplied must be replace, it must be replaced with type AWM 105° C - 18 gage wire.
VERIFY PROPER OPERATION AFTER SERVICING.
Schematic Representation Only
* Control Switches: Wall On/Off Switch or Timer, Unit Mounted On/Off Switch, or Remote Control Switch. If an optional control switch is installed, turn the appliance-
mounted ON/OFF burner control switch to the OFF position.
REPLACEMENT PARTS
A complete parts list is found at the end of this manual. Use only parts supplied from the manufacturer.
With proper care and maintenance, your appli­ance will provide many years of enjoyment. If you should experience any problem, first refer to the troubleshooting guide in this manual. If problem persists, contact your Lennox Hearth Products dealer or distributor.
Normally, all parts should be ordered through your Lennox Hearth Products distributor or dealer.
18
T
TP HTP
TH
Parts will be shipped at prevailing prices at time of order.
When ordering repair parts, always give the following information:
1. The model number of the appliance.
2. The serial number of the appliance.
3. The part number.
4. The description of the part.
5. The quantity required.
6. The installation date of the appliance.
If you encounter any problems or have any questions concerning the installation or ap­plication of this system, please contact your dealer or distributor.
Your Fireplace's Model Number ___________________________________________ Your Fireplace's Serial Number ___________________________________________ The Date On Which Your Fireplace Was Installed ______________________________ The Type of Gas Your Fireplace Uses _______________________________________ Your Dealer's Name ___________________________________________________
OFF/ON Switch
Pilot Burner Assembly
BL
BL
BK
BK = BLACK BL = BLUE R = RED W = WHITE G = GREEN
Control Switch *
DAMPER SWITCH
B-Vent appliances only - one or both of these switches must be factory installed in series as shown. If wires to these switches are replaced, wires must be Type AWM 200°C - 18 gage wire ONLY.
NOTES:
1. If any of the original wire as supplied must be replaced, use Type AWM 105°C - 18 gage wire ONLY.
2. 120 VAC, 60 Hz - Less than 3 Amps. CAUTION: label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and
dangerous operation. Verify proper operation after servicing.
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
(Integral with Gas Valve)
Honeywell Electronic Gas Valve
Igniter Connector
BK
HIGH LIMIT
SWITCH
ELECTRONIC IGNITION WIRING DIAGRAM
BK W
G
Junction Box
CAV 021
Control Switches: Wall On/Off
*
24 V
Secondary
GROUND
120 VAC Primary
Field Wired Factory
Wired
J-Box Wiring
**
accessories.
NOTES:
105°C - 18 gage wire ONLY.
operation after servicing.
Transformer
BL
R
BK
BK
LENNOX HEARTH PRODUCTS 1508 Elm Hill Pike, Suite 108 Nashville, TN 37210 visit us at www.LennoxHearthProducts.com 1-800-655-2008
PRODUCT REFERENCE INFORMATION
We recommend that you record the following important information about your fireplace. Please call Lennox Hearth Products for the phone number of your nearest Lennox Hearth Products dealer who will answer your questions or address your concerns.
Page 19
ACCESSORY COMPONENTS
Product Reference Information
Cat. No. Model Ship.
Weight
H7826 EBVSTNM-B 282 lbs. (36.2 cu.ft).
H7828 EBVSTNE-B 282 lbs. (36.2 cu.ft).
H7827 EBVSTPM-B 282 lbs. (36.2 cu.ft).
H7829 EBVPFNM-B 270 lbs. (36.2 cu.ft).
H7831 EBVPFNE-B 270 lbs. (36.2 cu.ft).
H7830 EBVPFPM-B 270 lbs. (36.2 cu.ft).
OFF/ON Wall Switch Kit
The OFF/ON wall switch kit may be used to control the operation of the fireplace burner. Install the OFF/ON wall switch in a convenient location near the fireplace.
Ship.
Volumn
Door Frame Kits
A decorative door frame kit is available for use with these appliances. The DTK is designed to attach directly to the front face of the appli­ance at its extreme edges. The DTK provides a picture frame finish for the appliance. The door frame kit can be retrofitted onto previ­ously installed appliances.
Catalog No. / Model No. and Number of Sets
Unit
Model
No.
EBVST --- 2 --- 2 EBVPF 1 2 1 2
Polished Brass Finish Brushed Stainless Finish
for 24" wide
glass door
88L43
DTK24PB-2
Door Frame Kits
for 40" wide
glass door
88L45
DTK40PB-2
for 24" wide
glass door
90L69
DTK24BS
for 40" wide
glass door
90L71
DTK40BS
White Wall Switch Kit
Cat. No. Model No. Description
85L87 FWSK OFF/ON Wall Switch Kit
Cost Effective Solution
•SimpleOn/Offoperation
•Workswithmillivoltandlowvoltageelectronic
ignition controls
Kit includes: Remote and Receiver
Manual or up to 3 hr Countdown Timer modes
•LCDdisplay
• Displaysroomtemp.inºForºC
• Flameiconandlowbatteryindicator
• Includesbatteries
• Wallclipincluded
•Receivermaybewallmountedorplacedin
the control compartment
• Includeswhitefaceplate
•Flameicon
•Lowbatteryindicator
•Batteriesincluded
Wall Control
•4-buttontimerwith30/60/120/OFFminutes
•Wallsurfacemounted
•Connectstowallswitchwire
•Perfectforrentalandresortapplications
Wall Switch, Countdown Timer
Cat. No. Model No. Description
H8863 WS-S-TMR Wall Switch
G-Fire Remote, Simple On/Off
Cat. No. Model No. Description
H8840 KIT-RC-G-FIRE Remote Control
Remote, Two Button, Timer,
On/Off Or Timer Mode
Cat. No. Model No. Description
H8860 RC-S-1 Remote Control
19
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
Page 20
ACCESSORY COMPONENTS CONTINUED
()
()
P
T
A
N
I
Touch-Up Paint Kits
Cat. No. Model No. Description
90L73 TPK-B Touch-Up Paint (Black)
Touch-Up Paint Kit
Repair of minor scratches and discoloration of the appliance black painted surfaces may be accomplished with the touch-up paint kit.
Decorative Firebox Accessories
Cat. No. Model No. Description
88L53 FGE Bag of Glowing Embers
80L42 FDVS
H6319 ---- Bag of Vermiculite
Bag of Decorative Volcanic Stone
Bag of Glowing Embers Bag of Volcanic Stone Bag of Vermiculite
Barrier Screen Kits
Cat. No. Model No. Description
98K74 HG24 24" Barrier Screen
96K32 HG40 40" Barrier Screen
Barrier Screen Kits
These barrier screen kits create a barrier to prevent direct contact with the hot glass. The screen panel affixes directly to the glass enclosure panel.
Outside Combustion Air Kits
Cat. No. Model No. Description
81L87 FOAK-4 (with duct)
81L88 FOAK-4LD (without duct)
Outside Air Kits Models FOAK-4 and FOAK-4LD
Outside Air kits are available with duct (FOAK-4) and without duct (FOAK-4LD) for use if outside combustion air is required or desired. If model FOAK-4LD is used it must be used in conjunction with locally purchased, non-combustible Class 1 or Class 0 flexible duct.
Black Finish Louvers Kits
Decorative louvers are available for use with all Multi-Open Series appliances. These louvers are designed to replace the standard radiant panels that are provided with the appliance. These kits include a black finish top 3-piece assembly and a bottom 3-piece assembly. These kits can be retrofitted to previously installed appliances.
Replacement ember materials, volcanic stone or vermiculite are available for use with these appli­ances. Order kits as part of the periodic maintenance of the appliance.
20
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
STESFOREBMUNDNA
hsiniFkcalB
tinU
ledoM
.oN
ediw.ni42rof
rooDssalG
32L88
2-C42RVL TSVBE-2 FPVBE1 2
stiKylbmessArevuoLhsiniFkcalB
)ylbmessAmottoBeceip-3dnapoTeceip-3
ylbmessAmottoBeceip-3dnapoTeceip-3(
)ylbmessAmottoBeceip-3dnapoTeceip-3
ylbmessAmottoBeceip-3dnapoTeceip-3(
)ylbmessAmottoBeceip-3dnapoTeceip-3(
.ONLEDOM/.ONGOLATAC
ediw.ni04rof
rooDssalG
52L88
2-C04RVL
Page 21
ACCESSORY COMPONENTS CONTINUED
Brickaded Panel Liner Kits Model
Number
EBVPF
EBVST
Catalog Number
Model Number
H0778
EBLK-PF
H0779
EBLK-ST
The brickaded liner kits include ceramic panels as shown here. The panels have brick-like features in relief.
H0778
(Top Vent)
EBVPF
H0778
(Rear Vent)
EBVPF
H0779
(Top Vent)
EBVST
H0779
(Rear Vent)
EBVST
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
21
Page 22
ACCESSORY COMPONENTS CONTINUED
“Sunrise” Grille Kits
TALL ARCH PANE DOORS
40” Arch Pane Doors, Black
EBST
40” Arch Pane Doors, Satin Pewter
TAPD40SP
Style View™ Doors
Style View™ doors come in three styles. They are easy to install onto the standard glass door frame. Includes heavy-duty magnetic door latches and functional twin-pane doors. Style View Doors and Grille Kits are not available for the EBVPF model fireplaces.
Arch Design
ARCH DESIGN KITS
Cat. No. Model Description Model Series
H8771 AD40B-2 40” Arch Doors, Black
H8772 AD40SP-2 40” Arch Doors, Satin Pewter
ARCH PANE DESIGN KITS
H8777 APD40C-2 40” Arch Pane Doors, Black
H8778 APD40SP-2 40” Arch Pane Doors, Satin Pewter
Arch Pane Design
EBVST
EBVST
Square Pane Design
SQUARE PANE DESIGN KITS
H8783 SPD40C-2 40” Sq. Pane Doors, Black
H8784 SPD40SP-2 40” Sq. Pane Doors, Satin Pewter
EBVST
22
“Sunrise” Grille Kits
H3573 SUGK40C 40” Sunrise Upper Grille Kit, Black
H3575 SUGK40SP 40” Sunrise Upper Grille Kit, Satin Pewter
H3577 SLGK40C 40” Sunrise Lower Grille Kit, Black
H3579 SLGK40SP 40” Sunrise Lower Grille Kit, Satin Pewter
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
EBVST
Page 23
MAINTENANCE SCHEDULE
Annually (Before the onset of the Burning Season)
MAINTENANCE TASK ACCOMPLISHING PERSON PROCEDURE
Inspecting/Cleaning Burner, Logs and Controls
Check Flame Patterns and Flame Height
Inspecting/Cleaning Pilot and Burner Qualified Service Technician Refer to Figures 13 and 14 on Page 17. Remove any surface
Checking Vent System Qualified Service Technician Inspect the vent system at the top and at the base (within the
Appliance Checkout Qualified Service Technician Perform the appropriate appliance checkout procedure detailed
Replacing Glowing Ember (rockwool) Materials
Qualified Service Technician Inspect valve and ensure it is properly operating. Check piping
Qualified Service Technician Refer to Figure 11 on Page 16 and verify the flame pattern
Homeowner/Qualified Service Technician
for leaks. Vacuum the control compartment, fireplace logs and burner area.
and height displayed by the appliance conforms to the picture. Flames must not impinge on the logs. Ensure flames are steady (not lifting or floating).
build-up on pilot and burner assembly. Wipe the pilot nozzles, igniter/flame rod and hood. Ensure the pilot flame engulfs the flame sensor as shown.
firebox) for signs of blockage or obstruction. Look for any signs of dislocation or deterioration of the vent components. Note: Excessive condensation can cause corrosion of caps, pipe & fittings (excessive condensation can be caused by long lateral runs, too many elbows and/or exterior portions of the system being exposed to cold weather). Also inspect wall straps or plumbers's tape to ensure it is secure and in place.
in this manual.
Remove old ember materials (rockwool) and vacuum the ember placement area. Place new embers as described in this document.
Periodically (After the Burning Season)
MAINTENANCE TASK ACCOMPLISHING PERSON PROCEDURE
Cleaning Firebox Interior Homeowner Carefully remove logs, glowing embers (rockwool), volcanic
Check Flame Patterns and Flame Height
Checking Vent System Homeowner Inspect the vent system at the top and at the base (within the
Cleaning Front Glass Enclosure Panel Homeowner Clean as necessary following the directions provided in this
Homeowner Refer to Figure 11 on Page 16 and verify the flame pattern
stone and vermiculite. Vacuum out interior of the firebox. Clean firebox walls and log grate. Replace logs, glowing embers and vermiculite as detailed in this manual.
and height displayed by the appliance conforms to the picture. Flames must not impinge on the logs.
firebox) for signs of blockage or obstruction. Look for any signs of dislocation of the vent components.
manual. DO NOT TOUCH OR ATTEMPT TO CLEAN GLASS WHILE HOT.
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
23
Page 24
LIGHTING INSTRUCTIONS – MILLIVOLT GAS VALVE
FOR YOUR SAFETY READ BEFORE LIGHTING
WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life.
A. This appliance has a pilot which must be lighted by a piezo
igniter. When lighting the pilot, follow these instructions exactly.
B. BEFORE LIGHTING smell all around the appliance area for
gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor.
WHAT TO DO IF YOU SMELL GAS:
• Donottrytolightanyappliance.
• Donottouchanyelectricswitch;donotuseanyphoneinyour
building.
• Immediatelycall your gas supplier froma neighbor’s phone.
Follow the gas supplier’s instructions.
• Ifyoucannotreachyourgassupplier,callthefiredepartment.
C. Use only your hand to push in or turn the gas control knob.
Never use tools. If the knob will not push in or turn by hand, don’t try to repair it, call a qualified service technician. Force or attempted repair may result in a fire or explosion.
D. Do not use this appliance if any part has been under water.
Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water.
LIGHTING INSTRUCTIONS
1. STOP! Read the safety information above on this label.
2. (If applicable) Set the thermostat to lowest setting. Turn wall on/off switch, unit mounted on/off switch or remote control switch "OFF."
3. Turn OFF all electric power to the appliance.
4. Access the control compartment.
5. Push in gas control knob slightly and turn clockwise to "OFF."
NOTE: Knob cannot be turned from "PILOT" to "OFF" unless knob is
pushed in slightly. Do Not force.
6. Wait five (5) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP! Follow "B" in the safety information above on this label. If you don't smell gas, go to the next step.
7. Find pilot - located in firebox on the same plane as the top of the burner.
8. Turn knob on gas control counterclockwise to "PILOT."
9. Push in control knob all the way and hold in. Immediately light the pilot by triggering the piezo igniter (pushing the button) until pilot lights. Continue to hold the control knob in for about 1-1/2 minutes after the pilot is lit. Release knob and it will pop back up. Pilot should remain lit. If it goes out, repeat steps 5 through 9.
• If knob does notpop up whenreleased, stop andimmediately call
your service technician or gas supplier.
• If the pilot will not staylit after severaltries, turn thegas control
knob to "OFF" and call your service technician or gas supplier.
10. Turn gas control knob counterclockwise to "ON."
11. Close control compartment.
12. (If applicable) Turn on all electrical power to the appliance.
13. (If applicable) Set thermostat to desired setting. Turn wall on/off switch, unit mounted on/off switch or remote control switch "ON."
SIT
Robertshaw
Honeywell
Gas Control Valves
T
O
L
I
N
O
T
O
L
I
P
F
F
OUT
IN
Gas Control Knobs
ON
PILOT
OFF
PILOT
H
I
O
L
P
O
W
L
it
O
H
I
HI
LO
IN OUT
F
T
F
O
O
L
I
P
N
O
Pilot Assemblies
TPTH TP TH
24
TO TURN OFF GAS TO APPLIANCE
1. (If applicable) Set the thermostat to lowest setting. Turn wall on/off switch, unit mounted on/off switch or remote control switch "OFF."
2. Turn OFF all electric power to the appliance, if service is to be
performed.
3. Access the control compartment.
WARNING
DO NOT TOUCH GLASS UNTIL COOLED.
NEVER ALLOW CHILDREN TO TOUCH GLASS.
P/N 62L2901_5
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
4. Push in gas control knob slightly and turn clockwise to "OFF." Do
not force.
5. Close the main line gas shut-off valve.
6. Close control compartment.
HOT GLASS WILL CAUSE BURNS.
Page 25
INSTRUCTIONS D’ALLUMAGE – VANNE GAZ MILLIVOLT
POUR PLUS DE SÉCURITÉ, LIRE AVANT D’ALLUMER
AVERTISSEMENT. Quiconque ne respecte pas à la lettre les instructions dans la présente notice risque de déclencher un incendie ou une explosion entraînant des dommages, des blessures ou la mort.
A.Cet appareil est muni d’une veilleuse qui doit être
• Appelezimmédiatement votre fournisseurdegaz depuis un
allumée avec un allumeur piézo-électrique. Respectez les instructions ci-dessous à la lettre.
B. AVANT L’ALLUMAGE: Avant d’allumer la veilleuse, reniflez
• Sivousnepouvezrejoindrelefournisseur,appelezleservice
C. Ne pousser ou tourner la manette d’admission du gaz qu’à la
tout autour de l’appareil pour déceler une odeur de gaz. Reniflez près du plancher, car certains gaz sont plus lourds que l’air et peuvent s’accumuler au niveau du sol.
QUE FAIRE SI VOUS SENTEZ UNE ODEUR DE GAZ :
• Nepastenterd’allumerd’appareil.
D. N’utilisez pas cet appareil s’il a été plongé dans l’eau, même
• Netouchez à aucuninterrupteur; ne pasvous servir des
téléphones se trouvant dans le bâtiment.
INSTRUCTIONS D’ALLUMAGE
1. ARRÊTEZ ! Lisez les instructions de sécurité sur la portion supérieure de
cette étiquette.
2. (Si applicable) Réglez le thermostat à la température la plus basse.
Tournez l’interrupteur murale, l’interrupteur sur l’unité ou le contrôle à distance à "OFF. "
3. Coupez l’alimentation électrique de l’appareil.
4. Accédez au compartiment de contrôle.
5. Enfoncez légèrement le bouton de réglage du gaz et tournez-le dans le sens
des aiguilles d’une montre jusqu’à la position d’arrêt “OFF”.
Remarque: Il est impossible de tourner le bouton de “PILOT” à “OFF” à
moins qu’il ne soit légèrement enfoncé. Ne le forcez pas.
6. Attendre cinq (5) minutes pour laisser échapper tout le gaz. Reniflez tout
autour de l’appareil, y compris près du plancher, pour déceler une odeur de gaz. Si vous sentez une odeur de gaz, ARRÊTEZ ! Passez à l’étape B des instructions de sécurité sur la portion supérieure de cette étiquette. S’il n’y a pas d’odeur de gaz, passez à l’étape suivante.
7. Trouver le pilote –
Situé dans l’âtre sur la même surface que le dessus du
brûleur.
8. Tournez le bouton de contrôle sur la valve à gaz dans le sens antihoraire
vers "Pilote".
9. Enfoncez le bouton de réglage jusqu’au fond et gardez-le enfoncé. Allumez
immédiatement la veilleuse en déclenchant l’allume-gaz à étincelle (en poussant le bouton) jusqu’à ce que la veilleuse s’enflamme. Continuez de tenir le bouton de réglage enfoncé pendant environ 90 secondes après l’allumage de la veilleuse. Relâchez le bouton et il sortira subitement. La veilleuse devrait rester allumée. Si
elle s’éteint, répétez les étapes 5 à 8
inclusivement.
10. Tournez le bouton de réglage du gaz en sens inverse des aiguilles d’une
11. Fermer le compartiment de contrôle.
12. (Si applicable) Mettez l’appareil sous tension.
13. (Si applicable) Réglez le thermostat à la température désirée.
voisin. Suivez les instructions du fournisseur.
des incendies.
main. Ne jamais employer d’outil à cette fin. Si la manette reste coincée, ne tentez pas de la réparer; appelez un technicien qualifié. Quiconque tente de forcer la manette ou de la réparer peut provoquer une explosion ou un incendie.
partiellement. Faites inspecter l’appareil par un technicien qualifié et remplacez toute partie du système de contrôle et toute commande qui ont été plongés dans l’eau.
• Si la manette ne sesoulève pas d’elle-mêmelorsqu’on la relâche,
arrêter et appeler immédiatement un technicien qualifié ou le fournisseur de gaz.
• Silaveilleuse ne reste pas allumée après plusieurstentatives,
réglez la manette d’admission du gaz à la position OFF et appelez un technicien qualifié ou le fournisseur de gaz.
montre jusqu’à sa position de marche “ON”.
l’interrupteur murale, l’interrupteur sur l’unité ou le contrôle à distance à "ON."
SIT
Robertshaw
Honeywell
Vanne Gaz Millivolt
T
O
L
I
IN
Bouton de réglage du gaz
ON
PILOT
OFF
PILOT
H
I
O
L
T
O
L
I
P
N
O
O
W
L
it
P
O
F
F
H
I
OUT
HI
LO
IN OUT
F
T
F
O
O
L
I
P
N
O
Millivolt Pilot
TPTH TP TH
Tournez
COMMENT COUPER L’ADMISSION DE GAZ DE L’APPAREIL
1. (Si applicable) Réglez le thermostat à la température la plus basse. Tournez l’interrupteur murale, l’interrupteur sur l’unité ou le contrôle à distance à "OFF. "
2. Coupez l’alimentation électrique de l’appareil s’il faut procéder à l’entretien.
3. Accédez au compartiment de contrôle.
AVERTISSEMENT
UNE SURFACE VITRÉE CHAUDE PEUT CAUSER DES BRÛLURES.
LAISSER REFROIDIR LA SURFACE VITRÉE AVANT D'Y TOUCHER.
NE PERMETTEZ JAMAIS À UN ENFANT DE TOUCHER LA SURFACE VITRÉE.
P/N 62L3001_4
REMARQUE : LES SCHÉMAS ET LES ILLUSTRATIONS NE SONT PAS À L’ÉCHELLE.
4. Enfoncez légèrement le bouton de réglage du gaz et tournez-le dans le sens des aiguilles d’une montre jusqu’à la position d’arrêt “OFF”. Ne forcez pas le bouton.
5. Fermer la valve de gaz principale.
6. Fermer le compartiment de contrôle.
25
Page 26
LIGHTING INSTRUCTIONS — ELECTRONIC
FOR YOUR SAFETY READ BEFORE OPERATING
WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life.
A. This appliance is equipped with an ignition device which
automatically lights the pilot. Do not try to light the pilot by hand.
B. BEFORE OPERATING smell all around the appliance area for
gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor.
WHAT TO DO IF YOU SMELL GAS:
• Donottrytolightanyappliance.
• Donottouchanyelectricswitch;donotuseanyphoneinyour
building.
• Immediatelycall your gas supplier froma neighbor’s phone.
Follow the gas supplier’s instructions.
• Ifyoucannotreachyourgassupplier,callthefiredepartment.
C. Use only your hand to actuate the gas valve ON/OFF switch.
Never use tools. If the switch will not move by hand, don’t try to repair it, call a qualified service technician. Force or attempted repair may result in a fire or explosion.
D. Do not use this appliance if any part has been under water.
Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water.
OPERATING INSTRUCTIONS
1. STOP! Read the safety information above on this label.
2. (If applicable) Set the thermostat to lowest setting. Turn wall on/off switch, unit mounted on/off switch or remote control switch "OFF."
3. Turn OFF all electric power to the appliance.
4. This appliance is equipped with an ignition device which automatically lights the pilot. Do not try to light the pilot by hand.
5. Access the control compartment.
6. Turn the ON/OFF switch, on the gas control valve, to "OFF." Do not force.
7. Wait five (5) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP! Follow "B" in the safety information above on this label. If you don't smell gas, go to the next step.
8. Turn the ON/OFF switch, on the gas control valve, to "ON." Do not force.
9. Turn on all electrical power to the appliance.
10. (If applicable) Set thermostat to desired setting. Turn wall
11. Close control compartment.
12. If the appliance will not operate, follow the instructions "To
on/off switch, unit mounted on/off switch or remote control switch "ON."
Turn Off Gas To Appliance" and call your service technician or gas supplier.
ON / OFF Switch
N O
F F O
L O R T N O C
G I N T I E R
Gas Control Valve
N I
I S P
Electronic Pilot Assembly
26
TO TURN OFF GAS TO APPLIANCE
1. (If applicable) Set the thermostat to lowest setting. Turn wall on/off switch, unit mounted on/off switch or remote control switch "OFF."
2. Turn "OFF" all electric power to the appliance, if service is to be performed.
WARNING
HOT GLASS WILL CAUSE BURNS.
DO NOT TOUCH GLASS UNTIL COOLED.
NEVER ALLOW CHILDREN TO TOUCH GLASS.
P/N 62L2701_5
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
3. Access the control compartment.
4. Turn the ON/OFF switch, on the gas control valve, to "OFF." Do not force.
5. Close the main line gas shut-off valve.
6. Close control compartment.
Page 27
INSTRUCTIONS D’ALLUMAGE — ELECTRONIC
POUR PLUS DE SÉCURITÉ LIRE AVANT DE METTRE EN MARCHE
AVERTISSEMENT. Quiconque ne respecte pas à la lettre les instructions dans la présente notice risque de déclencher un incendie ou une explosion entraînant des dommages, des blessures ou la mort.
A. Cet appareil est muni d’un dispositif d’allumage qui allume
automatiquement la veilleuse. Ne tentez pas d’allumer la veilleuse manuellement.
B. AVANT DE FAIRE FONCTIONNER, reniflez tout autour de
l’appareil pour déceler une odeur de gaz. Reniflez près du plancher, car certains gaz sont plus lourds que l’air et peuvent s’accumuler au niveau du sol.
QUE FAIRE SI VOUS SENTEZ UNE ODEUR DE GAZ :
•Nepastenterd’allumerd’appareil.
•Ne touchezà aucun interrupteur; nepas vous servirdes
téléphones se trouvant dans le bâtiment.
• Appelezimmédiatement votre fournisseurdegaz depuis un
voisin. Suivez les instructions du fournisseur.
• Sivousnepouvezrejoindrelefournisseur,appelezleservice
des incendies.
C. N'utilisez que votre main pour manipuler l'interrupteur
"ON/OFF" de la valve á gaz. N'utilisez jamais d'outils. Si l'interrupteur ne bouge pas manuel lement, n'essayez pas de le réparer. Communiquez immédiatement avec un technicien de service qualifié. Toute tentative pour forcer l'interrupteur ou le réparer, risquerait de provoquer un incendie ou une explosion.
D. N’utilisez pas cet appareil s’il a été plongé dans l’eau, même
partiellement. Faites inspecter l’appareil par un technicien qualifié et remplacez toute partie du système de contrôle et toute commande qui ont été plongés dans l’eau.
INSTRUCTIONS DE MISE EN MARCHE
1. ARRÊTEZ ! Lisez les instructions de sécurité sur la portion supérieure de cette étiquette.
2. (Si applicable) Réglez le thermostat à la température la plus basse. Tournez l’interrupteur murale, l’interrupteur sur l’unité ou le contrôle à distance à "OFF."
3. Coupez l’alimentation électrique de l’appareil.
4. Cet appareil est muni d’un dispositif d’allumage qui allume automatiquement la veilleuse. Ne tentez pas d’allumer la veilleuse manuellement.
5. Accédez au compartiment de contrôle.
6. Tournez l’interrupteur sur la valve de contrôle à "OFF." Ne pas forcer.
7.
Attendre cinq (5) minutes pour laisser échapper tout le gaz. Reniflez tout autour de l’appareil, y compris près du plancher, pour déceler une odeur de gaz. Si vous sentez une odeur de gaz, ARRÊTEZ ! Passez à l’étape B des instructions de sécurité sur la portion supérieure de cette étiquette. S’il n’y a pas d’odeur de gaz, passez à l’étape suivante.
8. Tournez l’interrupteur sur la valve de contrôle à "ON." Ne pas forcer.
9. Mettez l’appareil sous tension.
10.(Si applicable) Réglez le thermostat à la température désirée. Tournez l’interrupteur murale, l’interrupteur sur l’unité ou le contrôle à distance à "ON."
11. Fermer le compartiment de contrôle.
12. Si l’appareil ne se met pas en marche, suivez les instructions intitulées « Comment couper l’admission de gaz de l’appareil » et appelez un technicien qualifié ou le fournisseur de gaz.
Commutateur ON/OFF
N O
F F O
L O R T N O C
G I N T I E R
Valve Honeywell
N I
I S P
Veilleuse de
l’appareil électronique
COMMENT COUPER L’ADMISSION DE GAZ DE L’APPAREIL
1. (Si applicable) Réglez le thermostat à la température la plus basse. Tournez l’interrupteur murale, l’interrupteur sur l’unité ou le contrôle à distance à "OFF."
2. Coupez l’alimentation électrique de l’appareil s’il faut procéder à l’entretien.
AVERTISSEMENT
UNE SURFACE VITRÉE CHAUDE PEUT CAUSER DES BRÛLURES.
LAISSER REFROIDIR LA SURFACE VITRÉE AVANT D'Y TOUCHER.
NE PERMETTEZ JAMAIS À UN ENFANT DE TOUCHER LA SURFACE VITRÉE.
P/N 62L2801_4
REMARQUE : LES SCHÉMAS ET LES ILLUSTRATIONS NE SONT PAS À L’ÉCHELLE.
3. Accédez au compartiment de contrôle.
4. Tournez l’interrupteur sur la valve de contrôle à ‘’OFF.’’ Ne pas forcer.
5. Fermer la valve de gaz principale.
6. Fermer le compartiment de contrôle.
27
Page 28
TROUBLESHOOTING
NOTE: Before troubleshooting the gas control system, Ensure external gas shut off valve, located at gas supply inlet, (and wall switch, iff applicable), is in the “ON” position.
Important: Valve system troubleshooting should only be accomplished by a qualified service technician.
TROUBLESHOOTING GUIDE - MILLIVOLT GAS CONTROL SYSTEM
SYMPTOM POSSIBLE CAUSES CORRECTIVE ACTION
1. Spark igniter will not light pilot after
repeated triggering of igniter button.
WARNING: if the pilot will not light
after 1 minute of attempting, wait for at least 5 minutes for gas to clear before attempting again.
2. Pilot will not stay lit after
carefully following the lighting instructions.
3. Pilot burning, no gas to burner, Valve
knob “ON,” and the (standard) burner OFF/ON switch is “ON." Read impor­tant note below.
IMPORTANT NOTE: If an optional
*remote switch is used for burner operation, if the standard burner
OFF/ON switch is still installed on
appliance it must be in the "OFF" position.
*Optional remote switch kits - wall
switch or timer, or remote control.
4. Frequent pilot/burner outage prob-
lem.
A. Defective igniter (no spark at electrode).
B. Defective or misaligned electrode at pilot
(spark at electrode).
C. Gas supply pressure errant. Check inlet gas pressure. It should be within the limits
D. Pilot orifice plugged. Clean or replace pilot orifice. A. Defective pilot generator
(thermocouple).
A. Wall switch or wires defective. Check wall switch and wires for proper connections.
B. Thermopile may not be generating suf-
ficient millivolts.
C. Plugged burner orifice. Check burner orifice for blockage and remove. D. OFF/ON Switch & *Remote Switch are in
the "ON" position resulting in excessive resistance.
A. Pilot flame may be too low or blowing (high)
causing the pilot/valve safety to drop out.
Check for spark at electrode and pilot; if no spark and electrode wire is properly connected, replace igniter.
Using a match, light pilot. If pilot lights, turn off pilot and trigger the igniter button again. If pilot lights, an improper gas mixture caused the bad lighting and a longer purge period is recommended. If pilot will not light – check gap at electrode and pilot – should be 1/8" to have a strong spark. If gap measures 1/8", replace pilot (see Figures 13 or 14 on Page 12).
as marked on the rating plate.
Check pilot flame, it must impinge on thermocouple (see Figures 13 or 14 on Page 12). Clean and/or adjust pilot for maximum flame impingement on thermocouple. Ensure that the connection between the valve and thermocouple are tight and secure.
Jumper wire across terminals at wall switch, if burner comes on, replace defective wall switch. If okay, jumper wires across wall switch wires at valve, if burner comes on, wires are faulty or connections are bad.
Check thermopile with millivolt meter. Take reading at thermopile terminals of gas valve. Should read 325 millivolts minimum with optional wall switch “OFF.” Replace faulty thermopile if reading is below specified minimum.
When turning on the burner using a *remote switch, ensure that the standard OFF/ON switch is in the "OFF" position. If both switches are in the ON position, it may result in excessive resistance (& millivolt drain­age) and the burner may not come on.
Clean and/or adjust pilot flame for maximum flame impingement on thermocouple (see Figures 13 or
14 on Page 12).
TROUBLESHOOTING GUIDE - ELECTRONIC IGNITION SYSTEM
SYMPTOM POSSIBLE CAUSES CORRECTIVE ACTION
1. Burner will not light. A. Faulty Valve System. See Page 29. B. “OFF/ON” or wall switch defective. Disconnect the two black wires from the wire nuts.
2. Burners come “ON,” then turns “OFF.” A. Burner orifice plugged. Check main burner orifice(s) for blockage. Clean
B. Obstructed vent system. Check vent system for obstructions.
28
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
Test switch(s) for continuity with a multimeter. If continuity is not indicated, switch(s) is defective and must be replaced.
Note: Before replacing “OFF/ON” switch, Ensure to check wiring for loose connections or broken wires and repair as needed.
or replace.
Page 29
TROUBLESHOOTING THE ELECTRONIC IGNITION SYSTEM (CONTINUED)
1
2
2
121
START CHECK
•  Check forproper volt-
•TurnOffGasSupply.
•EnsureValveSwitchIsInONPosition.
•DisconnectControlHarness.
Insert A
End View of Control Harness Connector
age at control harness (see insert A). Voltage should be 24V between pressure switch and 24V common and 24V hot.
YES
•Plugcontrolharnessintovalve.
Wait for internal check delay.
NO
•Linevoltagepower
•Lowvoltagetransformer
•Limitcontroller
•Wiring
24 Volt Hot
Common
24 Volt
Switched
Check For Damaged or Missing Terminals in Connector
Insert B
Igniter Terminals
24 Volt
 • With pilotburner cable con-
•Igniterwarmsupandglowsred.
NO
nected, measure voltage at valve HSI element output. 24V nominal. (See insert B)
YES
YES •Replaceigniter/amerod
assembly.
YES
•Checkthatpilotgasisowing.Wait
•Turnongassupply.
NO
to ensure pilot gas tubing is purged.
•Pilotburnerlights.
YES
•Measurevoltagebetween24Vhotand
24V common leads to valve control. Must measure at least 19.5 VAC with igniter powered (see insert A). To
YES
identify proper lead, this check must be done with the valve control con­nected and igniter powered.
YES
•ReplacePilotAssembly.
•Check that pilotamemakesgood
contact with pilot burner flame rod.
• Main valve opens and main
burner lights.
•Checkforgoodelectricalconnection
NO
through the pilot tubing.
•Ifbothoftheabovearegood,replace
igniter/flame rod assembly.
YES YES
•SystemIsokay. •Cycleon/offswitchoffandbackon.
NO
•Replacevalve.
NO
•Replacevalve.
•Checktransformerand
NO
line volt supply.
Igniter will cycle off and back
on once during the 90 second ignition trial. All voltage measurements must be taken
When measuring voltage
at connections, use care to ensure terminals are not damaged.
•Mainburnerlights.
NO
•Replacevalve.
while the igniter is powered.
29
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
Page 30
REPLACEMENT PARTS LIST
No. Description
1a Upper Radiant, Black - 24" H6335 none 1 1b Upper Radiant, Black - 40" H6334 2 2 2a Hood, Black - 24" 98K95 none 1 2b Hood, Black - 40" 97K52 2 2 3a Upper Bustle, Black - 24" H6353 none 1 3b Upper Bustle, Black - 40" H6351 2 2 4a Glass Enclosure Assembly - 24" H6591 none 1
4b Glass Enclosure Assembly - 40" H6365 2 2 5a Lower Bustle, Black - 24" H6341 none 1 5b Lower Bustle, Black - 40" H6339 2 2 6a Lower Radiant Assembly, Black
- 24"
6b Lower Radiant Assembly, Black
- 40" 7 Nameplate (Brand) 12L15 2 2 8 Log Set 55M04 1 1
9a Bag of Vermiculite H6319 1 1 9b Bag of Embers - (Rockwool) 88L53 1 1
9c Bag of Decorative Volcanic Stone 80L42 1 1 10 Magnet, Radiant Panel H3876 2 4 11 Burner Assembly H6267 1 1 12 Gasket, Venturi Tube Mounting 43k85 1 1 13 Latch, Glass Enclosure Panel 69L21 2 2 14 Magnet, Latch, Spring-Loaded 69L31 4 4 15 Switch, Rocker 27K30 1 1 16 Limit Switch 62L16 1 1 17 Flex Gas Line Connector 93L32 1 1
Natural and Propane
Part No. Qty.
EBVST
H6343 none 1
H6342 2 2
EBVPF
Qty.
Gas Controls — SIT Millivolt
No. Description Natural Propane
Part No. Qty. Part No. Qty. 30 Gas Valve - SIT H6209 1 88J53 1 31 Piezo Igniter 10K86 1 10K86 1 32 Pilot Assembly 69L17 1 69L18 1 33 Pilot Generator 60J79 1 60J79 1 34 Thermocouple 74L57 1 74L57 1 35 Pilot Tube 74L56 1 74L56 1 36 Electrode and Cable H6212 1 H6212 1 37 Modesty Panel / Sticker
Assembly
H6305 1 H6305 1
Gas Controls — Honeywell Electronic
No. Description Natural Propane
Part No. Qty. Part No. Qty. 40 Gas Valve - Honeywell 62L18 1 62L19 1 41 Pilot Assembly 62L14 1 62L15 1 42 Transformer 42J32 1 42J32 1 43 Igniter Assembly (kit) 87L54 1 87L54 1 44 Modesty Panel/Sticker
Assembly
45 Pilot Tube LB-97487A 1 LB-97487A 1
H6304 1 H6304 1
Gas Orifices, Main — SIT And Honeywell Systems
No. Description Natural Propane
Part No. Qty. Part No. Qty. 50 Gas Orifice - EBVST / EBVPF 37L82 1 H4873 1
Contact a Lennox Hearth Products dealer to obtain any of these parts. Never use substitute materials. Use of non-approved parts can result in poor performance and safety hazards.
WARNING
Failure to position the parts in accordance with these diagrams or failure to use only parts specifically approved with this appliance may result in property damage or personal injury.
Risque de dommages ou de blessures si les pièces ne sont pas installées conformément à ces schémas et ou si des pièces autres que celles spécifiquement approuvées avec cet appareil sont utilisées.
AVERTISSEMENT
30
Page 31
REPLACEMENT PARTS
2b
4b
5b
6b
1b
3b
42
7
10
11
15
31
37
43
41
45
32
33
12
50
14
44
13
35
36
9b
8
34
1a
2a
3a
4a
5a
6a
10
Cabinet Corner Post Location
17
9a
16
Inside Location
40
30
NOTE: EBVPF Shown - see the tables on Page 30 for replacement parts applicable to EBVST fireplaces.
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
31
Page 32
Lennox Hearth Products reserves the right to make changes at any time, without notice, in design, materials, specifications, prices and also to discontinue colors, styles and products. Consult your local distributor for fireplace code information.
LENNOX®, the LENNOX design, DAVE LENNOX, the image of DAVE LENNOX and other related LENNOX marks are registered or common law trademarks of Lennox Industries Inc. and are used with permission.
Printed in U.S.A. © 2004 Lennox Hearth Products LLC
P/N 875026M REV. F 04/2013
1508ElmHillPike,Suite108•Nashville,TN37210