42" Wood Burning Fireplaces
P/N 850,047M REV. B 12/2008
MODELS
RDI-42HCI-42
RDI-42-HHCI-42-H
This installation manual will enable you to obtain a safe, efficient and
dependable installation of your fireplace system. Please read and understand these instructions before beginning your installation.
Do not alter or modify the fireplace or its components under any
circumstances. Any modification or alteration of the fireplace system,
including but not limited to the fireplace, chimney components and
accessories, may void the warranty, listings and approvals of this system
and could result in an unsafe and potentially dangerous installation.
IMPORTANT! TO ASSURE PROPER ALIGNMENT OF GLASS DOORS:
INSTALL THIS FIREPLACE IN A SQUARE AND PLUMB CONDITION,
USING SHIMS AS NECESSARY AT SIDES AND/OR BOTTOM.
INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future reference.
This manual is part of a set of two supporting
this product. Refer to manual 875,039M for
Care And Operation Instructions.
IMPORTANT: PLEASE READ AND
UNDERSTAND THESE RULES TO
FOLLOW FOR SAFETY.
1. Before starting your fireplace installation,
read these installation instructions carefully to
be sure you understand them completely and in
entirety. Failure to follow them could cause a
fireplace malfunction resulting in serious injury
and/or property damage.
2. Always check your local building codes. The
installation must comply with all local, regional,
state and national codes and regulations.
3. These fireplaces must be installed with
Security Chimney's FTF8 (8" inside diameter)
Chimney System only. These systems are intended for use in any application where a
traditional masonry type fireplace would apply. The chimney system must always vent to
the outside of the building.
4. To ensure a safe fireplace system and to
prevent the build-up of soot and creosote,
inspect and clean the fireplace and chimney
prior to use and periodically during the heating
season.
5. Use solid fuel only. DO NOT use artificial
wax based logs, chemical chimney cleaners or
flame colorants in your fireplace.
6. DO NOT use charcoal or coal under any
circumstances.
7. NEVER use gasoline, gasoline-type lantern
fuel, kerosene, charcoal lighter fluid, or similar
liquids to start or “freshen up” a fire in this
fireplace. Keep any flammable liquids a safe
distance from the fireplace.
8. NEVER leave children unattended when
there is a fire burning in the fireplace.
9. Always keep flue damper open when heat is
present in the fireplace.
10. Before servicing, allow the fireplace to
cool. Always shut off any electricity or gas to
the fireplace while working on it. This will
prevent any possible electrical shock or burns.
11. This fireplace is not intended to heat an
entire home or be used as a primary heat
source. It is designed to ensure homeowner
comfort by providing supplemental heat to the
room.
12. Always ensure an that adequate supply of
replacement combustion air from the outside
of the house is accessible to the fire to support
normal combustion. Fireplaces consume large
volumes of air during the normal combustion
process. In the event the home is tightly sealed
with modern energy efficient features, the optional combustion air kit may not provide all
the air required to support combustion.
The manufacturer is not responsible for any
smoking or related problems that may result
from the lack of adequate combustion air. It is
the responsibility of the builder/contractor to
ensure that adequate combustion air has been
provided for the fireplace.
13. DO NOT use a fireplace insert or any other
products not specified herein by the manufacturer for use with this fireplace. All gas log sets
must be operated with the damper clamped
open, including unlisted “vent free” log sets.
Listed “vent-free” log sets may be operated
with the damper closed.
14. "Smoke free” operation is not warranteed
nor are we responsible for inadequate system
draft caused by mechanical systems, general
construction conditions, inadequate chimney
heights, adverse wind conditions and/or unusual environmental factors or conditions beyond our control.
15. Never, under any circumstances, install a
fireplace, chimney component or any accessories, that has visible or suspected physical
damage as a result of handling or transportation. These items should be inspected by your
distributor or qualified factory representative
to ensure safe condition. When in doubt, consult your distributor.
16. For additional safety considerations and
complete operating instructions, refer to the
Care and Operation Manual provided with the
fireplace.
TOOLS AND BUILDING SUPPLIES
NORMALLY REQUIRED
Tools should Include:
Phillips screwdriver
Hammer
Saw and/or sabersaw
Level
Measuring tape
Plumb line
Electric drill and bits
Pliers
Square
to install. However, in the interest of safety, it is
recommended that the installer be a qualified or
certified “tradesman” familiar with commonly
accepted fireplace installation and safety techniques as well as prevailing local codes.
Note: Illustrations shown reflect “typical”
installations with nominal dimensions and
are for design and framing reference only.
Actual installations may vary due to individual design preferences. However, always
maintain minimum clearances to combustible materials and do not violate any specific installation requirements.
WARNING: FAILURE TO USE MANUFACTURE PROVIDED PARTS, VARIATIONS IN
TECHNIQUES AND CONSTRUCTION MATERIALS OR PRACTICES OTHER THAN
THOSE DESCRIBED IN THIS MANUAL
MAY CREATE A FIRE HAZARD AND VOID
THE LIMITED WARRANTY.
The most important areas of concern dealing
with the installation of factory-built fireplaces are
clearances to combustible materials, proper assembly of component parts, height of the chimney system, the proper use of accessories supplied by the manufacturer and the techniques
employed in using finishing materials applied to
the wall surrounding the fireplace, hearth extensions and wall shields. Each of these topics will
be covered in thorough detail throughout this
manual. Please give each your special attention
as you progress with your installation.
INTRODUCTION
General Information
These fireplaces are conventional radiant heat
fireplaces with standard bar grates, optional
outside combustion air kits and optional decorative glass doors.
The "C" models are designed as heat circulating
fireplaces and may be fitted with accessory fans.
TYPICAL INSTALLATION
These fireplaces have been tested and
listed by Omni-Test Laboratories (Report
No. 116-F-52-2) to U.L. standard 127.
These units are intended for installation
in residential homes and other buildings
of conventional construction including
commercial, not in mobile homes.
These fireplaces have been tested for installation in Canada to ULC-S610. For installa-
tions in Canada, the chimney clearance to
combustibles must be 2 inches and the
Cold Climate Kit must be installed.
These fireplace systems are designed for
installation in accordance with the National
Fire Protection Standard for chimneys, fireplaces and solid fuel burning appliances;
NFPA 211 and in accordance with codes
such as the BOCA Basic/National Codes, the
Standard Mechanical Code and the Uniform
Building Codes.
When complete these fireplace systems consists of four basic “sub-systems”:
1. The Fireplace
2. The Chimney and Termination
3. The Optional Glass Doors
4. The Optional Combustion Air Kits
5. Optional Cold Climate Kit (Mandatory in
Canada).
CLEARANCES AND HEIGHT
REQUIREMENTS
The fireplace may be placed on or near normal
construction materials*. The combustion air kit,
firestop spacer and roof flashing (not chase
flashings) may be placed directly on or against
normal construction materials.* The chimney
requires a minimum 2" air space clearance to
combustibles. The fireplace outer wrapper
requires a minimum 1" air space clearance to
combustibles. A combustible mantle may be
installed 12" above the opening of the fireplace as
per NFPA 211, Section 7-2.3.3. In Canada, the
minimum is 18" above the fireplace opening.
The minimum installed height of the completed
fireplace system is 15' 0". The maximum height
is 60' 0".
Radiant Model Shown
Figure 1
Chimney and
Termination
Outside
Combustion
Air Kit
(Optional)
Circulating Model Shown
Blower Kit
(Optional)
Chimney and
Termination
Outside
Combustion
Air Kit
(Optional)
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.
The fireplace and chimney system must be
enclosed when installed in or passing through
a living area where combustibles or people may
come in contact with it. This is important to
prevent possible personal injury or fire hazard.
For questions, please call your distributor or
the manufacturer. Special restrictions apply to
the front and facing of the fireplace and nearby
walls (See pages 16, 17 and 18 ).
CHIMNEY SYSTEM
These fireplaces are designed and code listed
for use with Security Chimneys FTF8 chimney
System only. Always use Security Chimneys
FTF8 chimney components with these fireplaces. Do not modify or alter these components as this may cause a potential serious
hazard and void the Warranty.
*Construction Materials:
• framing materials• paneling
• particle board• flooring
• dry wall• etc.
• plywood
3
Insulate Joists
Same As Ceiling
Draft Stops
Chimney Height
The total height of your completed fireplace
system from the surface the fireplace rests on
to the chimney top must not exceed 60' and
must also meet minimum height requirements.
Refer to the minimum system height chart.
Minimum System Height
LOCATION OF FIREPLACE
Carefully select the proper location for heat
circulation, aesthetics, chimney obstructions
and clearance to side wall(s). With proper preplanning, a slight adjustment of a few inches
can save considerable time and expense later
during construction and assembly.
Firestop
CTDT
Termination
Note: NonCombustible
Chase
Flashing
Must Be
Used To
Cover
Chase
Opening
Optional
Insulation
In Outside
Walls Of
Chase
8'
Level
Solid
Continuous
Surface
Outside
Insulation
(Thermal Barrier)
Base
Figure 2
WARNING: IF INSULATION IS USED, THE
FIREPLACE MUST NOT BE PLACED DIRECTLY AGAINST IT. INSULATION OR
VAPOR BARRIERS, IF USED, MUST FIRST
BE COVERED WITH GYPSUM BOARD,
PLYWOOD, PARTICLE BOARD OR OTHER
MATERIAL TO ASSURE INSULATION AND
VAPOR BARRIERS REMAIN IN PLACE.
WARNING: DO NOT PACK OR FILL REQUIRED AIR SPACES WITH INSULATION
OR OTHER MATERIAL. NO MATERIAL IS
ALLOWED IN THESE AREAS.
Note: Do not insulate the chase cavity with
blown or fill type insulation materials.
Note: Local codes may not require firestopping
at the ceiling levels for outside chase installations. However, it is recommended for safety
and the reduction of heat loss.
Security's FTF8 Pipe
Vertical Installation15' 0"
One Offset15' 0"
Two Offsets25' 0"
Chase Enclosure
A chase is a vertical box-like structure constructed to surround the fireplace and chimney.
Refer to
Figure 2
for a typical chase configuration. As with all chimney installations, avoid
overhead obstructions such as trees, power
lines, etc. A chase should be constructed and
insulated just like any outside wall. In a cold
climate, we recommend the base of the chase
should also be insulated between the solid
continuous floor beneath the fireplace and the
chase bottom. Chase insulation in a cold climate installation is not required for safety.
ASSEMBLY OUTLINE
Before You Start
Check your inventory list to be sure you have all
the necessary parts supplied in good usable
condition. Check also for any concealed damage.
Check the operation of the damper. The damper
is controlled through the use of a control lever
located within the firebox opening at the top
center just behind the firebox lintel (
The control lever snaps into place at the extreme range of motion, up and back in the
closed position. When pulled forward and
down, the damper is open.
Damper
Closed
Lintel
Damper
Open
Combustion
Air Actuator
Figure 3
Figure 3
Hearth
Hearth
Optional
Outside Chase
Figure 4
Carefully consider the position of the fireplace
opening with respect to the location of adjacent or nearby stairwells, bath or kitchen exhaust fans and/or return air registers for forced
air furnaces/air conditioners that could cause
a smoking fireplace condition if the house is
tightly insulated.
When locating the fireplace, consideration must
be given to combustibles and final finishing.
See
Figure 5
and confine the final location of
combustible finish materials to the "Safe Zone".
DO NOT permanently place furniture or other
items such as decorative pillows within 60" of
the fireplace front face.
).
12”
45°
Black Portion Of Frame
Not To Be Covered With
Combustible Materials
1”
Door
Opening
12”
Safe
Zone
Figure 5
Wall
Covering
4
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.
ASSEMBLY STEPS
Note: The following steps represent the normal
sequence of installation. Each installation is
unique, however, and might require a different
sequence.
1. Position firebox prior to framing or into
prepared framing.
1. Estimate the total weight of the fireplace
system including chimney and surround materials such as brick, stone, etc., to be installed. Shipping weights for the fireplace
may be found on page 18.
2. Measure the square footage of the floor
space to be occupied by the system, surrounds
and hearth extensions.
Top
Spacers
Maintain
1" (25 mm)
Air Space
At Back
And Sides
2. Install the chimney system.
3. Connect house wiring to the fireplace for
later attachment of optional blower.
4. Install optional outside combustion air kit.
5. Plumb gas line if a decorative gas appliance
will be used. (Gas connections should only be
performed by an experienced, licensed/certified tradesman.)
6. Complete the installation, finish wall material, surround and hearth extension to your
individual taste.
7. Assemble and attach optional glass door
assembly.
Study the three dimensional illustration (
ure 1
) to get a general idea of each element of
Fig-
your fireplace system.
PRE-INSTALLATION NOTES
The fireplace may be installed directly on a
combustible floor or raised on a platform of an
appropriate height. Do not place fireplace on
carpeting, vinyl or other soft floor coverings. It
may, however, be placed on flat wood, plywood, particle board or other hard surfaces.
Be sure fireplace rests on a solid continuous
floor or platform with appropriate framing for
support and so that no cold air can enter the
room from under the fireplace.
The fireplace may be positioned and then the
framing built around it, or the framing may be
constructed and the fireplace positioned into
the opening.
Usually, no special floor support is needed for
the fireplace, however, to be certain:
3. Note the floor construction, i.e. 2 x 6’s, 2 x 8’s
or 2 x 10’s, single or double joists, type and
thickness of floor boards.
4. Use this information and consult your local
building code to determine if you need additional support.
CAUTION: DO NOT BLOCK THE HEAT-CIRCULATING AIR INLET AND OUTLET PORTS ON
CIRCULATING MODELS. DOING SO MAY RESULT IN A POTENTIAL FIRE HAZARD.
If you plan to raise the fireplace and hearth
extension, build the platform assembly then
position fireplace and hearth extension on top.
Secure the platform to the floor to prevent
possible shifting.
CLEARANCES
Minimum clearance to combustibles for the
appliance is as follows: sides and back - 1" (25
mm), floor - 0" (0 mm), adjacent wall - 12" (305
mm), ceiling - 37-1/2" (953 mm).
INSTALLING THE FIREPLACE
Step 1. Slide the fireplace into prepared fram-
ing or position fireplace in its final position and
frame later.
The fireplace may not be recessed into a combustible floor. Maintain the floor to hearth clearance established by the fireplace lower front
face.
Step 2. Insert the provided metal safety strips,
beneath the fireplace as illustrated (
7 and 8
). The safety strips should overlap 1/2"
for continual coverage of the floor.
Note: Safety strips are not required when fireplace rests on a noncombustible surface.
Figures 6,
Hearth
1" (25 mm) Space
Metal Safety StripFloor
Note: Hearth extensions must not interfere with
circulating grillwork
Extension
Figure 6
Top
Spacers
Maintain
1" (25 mm)
Air Space
At Back
And Sides
Hearth
1" (25 mm) Space
Metal Safety StripFloor
Note: Hearth extensions must not interfere with
circulating grillwork
Platform
Extension
Figure 7
Note: Install the hearth extension only as illus-
trated.
The safety strips should extend from front of
the fireplace at least 1-1/2" and should extend to
be at least flush with the sides. In the event a
wooden support is used to elevate the fireplace
above the floor, a “Z” type safety strip should be
fabricated and used to protect the front surface
of the wood support as well as the floor beneath
the hearth extension (
Figures 8 and 9
). The
safety strips should be tacked down to prevent
possible movement.
Note: The “Z” type safety strip is not supplied.
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.
5
FIREPLACE SPECIFICATIONS
8-3/8"
(213 mm)
12-1/2"
(318 mm)
16-5/16"
(414 mm)
1-1/2"
Metal Safety Strips
Figure 8
Blocking
Metal Safety Strips
Figure 9
Step 3. Refer to fireplace drawings and specifi-
cations on pages 6 and 7 for framing dimensions
and details. Frame appliance enclosure as illustrated in
Figures 11 through 14
on page 8.
IMPORTANT: UNDER NO CIRCUMSTANCES
CAN THE FIREPLACE TOP SPACERS (
10
) BE REMOVED OR MODIFIED, NOR MAY
FIGURE
YOU NOTCH THE HEADER TO FIT AROUND OR
BE INSTALLED LOWER THAN THE SPACERS.
THE HEADER MAY BE IN DIRECT CONTACT
WITH THE TOP SPACERS BUT MAY NOT BE
SUPPORTED BY THEM.
Note: The framed depth, 23-7/8" (606 mm)
from a framed wall, must always be measured
from a finished surface. If a wall covering such
as drywall is to be attached to the rear wall, then
the 23-7/8" (606 mm) must be measured from
the drywall surface. It is important that this
dimension be exact.
If the appliance is to be elevated above floor
level, a solid continuous platform must be
constructed.
Gas Line
Access
40-1/2"
(1029 mm)
23-1/2"
(597 mm)
Left Side
8-1/2"
(216 mm)
22-5/16"
(566 mm)
12-1/2"
(318 mm)
46-3/4"
(1187 mm)
(1051 mm)
40-1/2"
(1029 mm)
41"
(1041 mm)
Front
(13 mm)
Combustion
Gas Line
41-3/8"
31-9/16"
(802 mm)
(73 mm)
1/2"
Air Inlet
Access
17-5/16"
(439 mm)
2-7/8"
7-3/4"
(197 mm)
Fireplace Top Spacers
(251 mm)
13-5/8"
(346 mm)
Junction
Box
22-7/8"
(581 mm)
Right Side
Fireplace
Top Spacer
(1178 mm)
9-7/8"
10"
(254 mm)
23-1/2"
(597 mm)
46-3/8"
46-3/8"
(1178 mm)
The header may rest on the top metal spacers,
but must not be notched to fit around them.
Consult all local codes.
6
1-3/4"
(44 mm)
Figure 10
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.
50-1/4"
(1276 mm)
Top View
46-3/4"
(1187 mm)