Lennox G12 Series, G12X Series, G12R Series User Information

USER'S INFORMATION
G12, G12R and G12X Series Units
i i ,i
GABUNIT8 RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE
502,253M 8/90 SuperP,edee 3188
Do not store or use gasoline or other
Eflammable vapors and liquids in the Ivicinity of this or any other appliance.
i
WARNING
Improper InStallation, adjustment, alter. arian, service, or ma|nte_'tance can
cause Injury or property damage. Refer
to this manual. For assistance or addi-
tional Information, consult a qualified Installer, service agency, or the gas supplier.
,,=
Litho U,S,A,
.... FOR YO01_'SAFETY
WHAT TO DO IFYOU SMELL GAS:
Do not try to light any appliance.
Open windows.
Do not touch any electrical swite,b; De
not use the phone In your building.
Immediately call your gas suppl|er from
a neighbor's phone. Follow the gas suppller's Instructions.
If you cannot reach your gas supplier,
call the fire department.
PARTSIDENTIFICATION
UPFLOW SERIES
BLOWER
DOWNFLOW SERIES
DIRECT
BLOWER
FAN AND
CONTROL
MAIN
VALVE
PILOT
BURNER
BOX
FILTER
HEAT
DIRECTDflIVE
FIGURE 1
WARNING-Should oyerhastlng occur or the ps supply fell to shut off, shut off the manual gas valve
before shutting off electrical supply.
WARNING-Do not use this furnace if any pad has been under water. Immediately call qualified ser-
vice technician to inspect the furnace and replace
any pert of the €ontrol s_tem and any gas'control that has been under water,
CAUTION-Before elf empties to perform any Nrvlce or maintenance, turn electrical power off to unit el
unit disconnect switch.
i-IMPORTANT DIRECTIONS
1- Keep furnace area clear and free of combustible
materials, gasoline and other flammable vapors and liquids,
If installed in art insulated area, furnace must be kept free of Insulating material. Insulating material
may be combustible. Inspect unit venting system to make sure it is in
piece, physically sound end without holes, corro-
sion or blockage,
CONNECTION
BLOWERAND
F'R.1T_
Inspect return sir duct to ensure duct is sealed to the furnace end terminates outside the space
containing appliance. Inspect physical support of unit to guerentee that
it is sound without sagging, cracks, or gaps
around base and it maintains seat between base
arx:l sopq:x_.
E- Do not obstruct aWflow to unit. Unit must receive
an unobstructed flow of combustion and ventilate _ng air.
3- Do not store chlorine Or fluorine products near unit
or introduce these products into the combustion air. These products Pan cause furnace coffosion.
II-LIGHTING iNFORMATiON AND OPERATION
FOR YOUR SAFETY READ BEFORE LIGHTING WARNING-If you do not follow these Instructions ax-
_tly, a fire or explosion may result causing proper- ty damage, personal Injury or loss of life.
BEFOREUGHTING smellall arounOthe appliancearea forgas, Be soreto smeltnextto thefloor because some
gas isheavier thanair and will settleon the floor.
Page 1 1¢19g0 Lermox Ir_llustrlel Inc,
Use.only your.hand to push in or turn the gas control
knob. Never use tools. If Ihe knob wit1not push in or turn by hand, do not fly to repair I1,call a qualified service tecrmicfan. Force or affempted repair may resuTtIn afke or explosion,
This unit is equipped with an automatic "gasvalve using
a standing (constant) pilot flame or and intermittent pilot (=E" and "X" series units). Standing pilot units
require manual lighting of pilot flame. Intermittent pilot
models have a pilot ignitor, Do NOT try to manually light the pilot on an "E" or "X" series unit.
A-PlacMg Furnace In Operation Stand_g Pltot Lighting Information
Refer to lightin_ instructions sticker on blower access panel and figure 2 for gas valve identlflP._ticn.
1-S'I'OPI Read the pilot safety information in pre-
vious section,
2- Sol thermostat to lowest setting. See figure 3. 3- Turn off all electrical power to appliance. 4- Remove burner access panel.
5- Push in g6s vane knob s_ghtly and turn ck_ckw{se
_lb 1o OFf =. See figure 5,
NOTE-Knob cannot be turned from PILOT to OFF unless knob fs de._'essed. Do not force.
6- Walt five (5) minutes to clear out any gas. If you
smell gas, STOP! Immediately call your gas s_llar from T0eighbor's phone. Follow tllegas suppl_or's Instructions. If you do not smell gas go to next step.
7- Remove the pilot access panel located below and
behind the gas valve.
8-Locate pilot--follow metal tube from gas valve.
_ee figure 6. The I_tot is be_ee_ the two b_rnsr tubes behind the pilot access panel.
9- Turn knob o_ gas valve countercJoc_vAse_l_ to
PILOT,
10- Push in knob on gas valve all the way.and ho_d in,
Immediately light pilot.with a match. Continue to hold the gas valve knob in for about one minute
after the pilot is lit, ff it goes out, repeat steps 5 through 10.
if knob does not pop up when reJeased, stop and immediately call your service technician or the gas supplier,
If pilot will not stay lit after several tries, turn the gas valve knob to OFF and call your service tech-
nioian or gas supplier.
WHITE RODGERS 36C GAS VALVE
ROBERTSHAW 7000 GAS VALVE
P.._ VALVE
OAS"#a,LVE
POSITION
HONEYWELL VRS00 GAS VALVE
HONEYWE II VBO0 GAS VALVE
GASVALVE
!otis SHOWN
tit OFF
POSITION
FIGURE 2
f I- Replace pilot access panel. 12-Turn gas valve knob counterclockwise to 41_
ON.
13- Replace bumeTacsess panel 14-Turn _ eHeleotdcaI pow_" tounit,
15- S_ B'mn'nostatto desk'edsetting.
Pope 2
Loading...
+ 5 hidden pages