Leica Geosystems CPD MTD0506 User Manual

User Manual
Version 1.0
English
Congratulations on your purchase of a Leica DISTO™.
The safety instructions can be found in a separate booklet, which accompanies this user manual. The
safety instructions along with the user manual should be read carefully before initial operation.
Helpful Hint: The first and last page including the pictures should be folded out and left open, whilst reading through the manual. Letters and Numbers in braces {} refer to the illustrations.
Content
Start-up................................................................ 1
Menu functions................................................... 3
Operation.............................................................4
Measuring ............................................................ 4
Functions .............................................................5
Working with BLUETOOTH® .............................. 8
Appendix.............................................................. 9
Leica DISTO™ A6 1.0.0 gb
Start-up
Inserting / replacing Batteries
See figure {C} - Open the positioning bracket. Remove the locking clip and slide the endpiece down. Slide the red locking mechanism to the side and open the battery compartment. Insert new or replace used batteries. Close battery cover, reinsert the endpiece and fix locking clip.
The battery symbol {B, 21} appears permanently blin­king in the display when the battery voltage is too low. The batteries should be replaced as soon as possible.
Pay attention to correct polarity.
•Use alkaline batteries.
Batteries should be removed if the device will not be used for a long time (danger of corrosion).
When changing the batteries the settings and stack content remain unchanged.
Multifunctional Endpiece
See figure {D} The device can be used for different measurement situations:
For measurements from an edge open the posi­tioning bracket until it locks in place. See figure {E}.
For measurements from a corner, open the posi­tioning bracket until it locks in place, with a slight
1
Start-up
D
GB
F
I
E
S
N
FIN
J CN RC
ROK
PL
H
RUS
CZ
D
GB
F
I
E
S
N
FIN
J CN RC
ROK
PL
H
RUS
CZ
push to the right the bracket can be turned further. See figure {D and F}.
A built-in sensor automatically detects the orienta­tion of the positioning bracket and calculates the corresponding distances accordingly.
Integrated telescopic viewfinder
The device is equipped with a telescopic viewfinder on the right hand side. The viewfinder is especially helpful when aiming at distant targets. When looking through the viewfinder, the target is clearly visible thanks to the 2x magnification. At distances beyond 30 m laser spot is centered on the crosshair, below 30 m the laser spot appears on the edge of the cros­shair, which is normal.
Level
The integrated bubble level allows simple horizontal levelling of the instrument.
Keypad
See figure {A}: 1 ON/MEASURING
22nd FUNCTION LEVEL
3 PLUS [+] 4 TIMER 5 EQUAL [=]
6AREA/VOLUME 7STORAGE 8 MEASUREMENT REFERENCE
Start-up
9 CLEAR/OFF 10 MENU
11 ILLUMINATION 12 INDIRECT MEASUREMENT (PYTHAGORAS) 13 MINUS [-]
14 BLUETOOTH
®
Display
See figure {B} 1 Information about faulty measurements 2 Laser active 3 Circumference
4 Maximum value of continuous measurement 5 Minimum value of continuous measurement 6 Measurement reference 7 Recall of Historical Storage 8 Storage of constant 9 Main line 10 Units with exponents ( 11 Ceiling area 12 Wall area 13 Three auxiliary lines (e.g. previous results)
14 BLUETOOTH 15 2nd Function Level on
16 Hardware error 17 Indirect measurement - Pythagoras 18 Indirect measurement - Pythagoras - partial height 19 Area / Volume 20 Offset setting 21 Battery indication
®
on/off
2
2/3
)
Leica DISTO™ A6 1.0.0 gb
Menu functions
Presettings
The menu allows selection of the settings that will remain in memory after the instrument is switched off.
Navigation in the Menu
Press the MENU -key {A, 10} repeatedly to scroll through the possible menu functions (UNIT, OFFSET, TRIPOD, RESET).
When the desired menu option appears, select it with the EQUAL - key {A, 5}, scroll through the possible settings with the PLUS - key {A, 3} or the MINUS - key {A, 13} and store the selected setting with the EQUAL - key {A, 5}. Press CLEAR - key {A, 9} to leave the menu without saving any changes in the settings.
Selecting Units
"UNIT" blinks in the display. Possible units:
Distance Area Volume
0.000 m
0.00 m 0 mm
0.00 ft
0.00
Leica DISTO™ A6 1.0.0 gb
1
/
ft in
32
0.000 m² 0.000 m³
0.00 m² 0.00 m³
0.000 m² 0.000 m³
0.00 ft² 0.00 ft³
0.00 ft² 0.00 ft³
Distance Area Volume
0' 0'' 1/
0.0 in
1
/32 in
0
32
0.00 ft² 0.00 ft³
0.00 ft² 0.00 ft³
0.00 ft² 0.00 ft³
Measure with offset
An offset automatically adds or subtracts a value to/ from ALL measurements. With this feature toler­ances can be taken into consideration e.g. between unfinished and finished dimensions.
Select the menu function OFFSET {B, 20} (OFFSET blinks in the display), confirm with the EQUAL - key {A, 5}. Adjust the OFFSET with the PLUS - key {A, 3} or the MINUS - key {A, 13}. By holding the keys down, the setting values will increase/decrease faster. Once you have entered the proper offset confirm your selection with the EQUAL
- key {A, 5}. As long as an OFFSET {B, 20} is added/ subtracted the symbol is visible on the display.
Measuring with tripod
Using a tripod eliminates shaking when measuring over long distances. On the back of the instrument is an industry standard ¼"-threaded hole for use with a camera tripod mounting screw. For correct measure­ments the reference needs to be adapted. Select the menu function TRIPOD {A, 8} ("triPod" blinks in the display) and confirm with the EQUAL - key {A, 5}.
3
Menu functions
D
GB
F
I
E
S
N
FIN
J CN RC
ROK
PL
H
RUS
CZ
D
GB
F
I
E
S
N
FIN
J CN RC
ROK
PL
H
RUS
CZ
Reset
When you select the menu function RESET ("rESET" will blink in the display) and press the EQUAL-key {A, 5} twice the device will default to factory settings.
CAUTION: Any customized presettings as well as stored values will be deleted.
Operation
Switching On/Off
ON: Press ON - key {A, 1} briefly. Battery indica-
tion is displayed until the next keystroke.
OFF: Press and hold OFF - key {A, 9}. To maximize
battery life the laser beam will switch off after 3 minutes of inactivity, the device will auto­matically switch off after 6 minutes of inacti­vity.
CLEAR key
Pushing the CLEAR - key {A, 9} clears the last entry or measurement. Within a function (area, volume, etc.) single measurements can be deleted step by step and remeasured.
Illumination
Pressing the ILLUMINATION - key {A, 11} turns on/ off the display backlight.
Operation
Measuring reference
If the positioning bracket is folded out, the device recognizes the position, adapts the reference and calculates distances accordingly.
The default reference setting is from the rear of the instrument. By pressing the REFERENCE - key {A, 8}, the setting can be changed, so that the next measu­rement taken will be from the "front" of the in-stru­ment. Afterwards the reference setting automatically defaults back to rear. See picture {G}. You can choose the "front" reference permanently by pressing the REFERENCE - key {A, 8} longer. Press the REFERENCE - key {A, 8} longer another time to change back to the "rear" reference. See also "Measuring with tripod".
Measuring
Single distance measuring
Pressing DIST - key {A, 1} turns the laser on. Aim at the desired target and press DIST - key {A, 1} again. The measured distance is displayed immediately in the chosen unit.
Minimum/maximum measuring
This function allows the user to measure the minimum or maximum distance from a fixed measu­ring point as well as to determine spacing - see figure {H}. It is commonly used to measure diagonal distances
4
Leica DISTO™ A6 1.0.0 gb
Loading...