Leica A60F User Manual

Leica A60 F Manual
Table of Contents
The Leica A60 F 12
Congratulations! 13 An Overview of the Leica A60 F 14
Assembling the Leica A60 F 15
Table Clamp 16 Flexible Arm Stand and Optics Carrier 17 Assembling the Illuminator 18
Using the Leica A60 F 19
Adjusting the Working Height 20 The Correct Interpupillary Distance 21 Focusing 22 Magnification Display 23 Dioptric Correction and Parfocality 24 Adjusting the Torque of the Focus Drive 25 Leica A60 LED Ring Illuminator 26 Replacing the Protective Glass 27
Dimensions 28
Dimensions 29
Optical Data 31
Optical Data 32
Leica A60 F Manual 2
Safety Instructions
Leica A60 F Manual 3
Symbols used in this operating manual
Warning! Safety hazard!
tant information that is mandatory to
read and observe.
Failure to comply can cause the following:
Ϙ Hazards to personnel
Ϙ Instrument malfunctions and damage
Warning of hazardous electrical voltage
This symbol indicates especially impor-
tant information that is mandatory to
read and observe.
Failure to comply can cause the following:
Ϙ Hazards to personnel
Ϙ Instrument malfunctions and damage
Danger due to hot surface
This symbol warns against touching
accessible hot surfaces, e.g. those of
light bulbs.
Important information
This symbol indicates additional infor-
mation or explanations that are intended
to provide clarity.
Leica A60 F Manual 4
Important Notes
Description
The Leica A60 F stereomicroscope meets today's state of the art of technology. Neverthe­less, hazards may still arise during operation. The potential risks are described below.
Before installing, operating or using the
instrument, it is mandatory to read this user manual. In particular, please observe all safety instructions.
User Manual
This user manual includes important instruc­tions related to operating safety, maintenance and accessories.
Your Leica A60 F stereomicroscope
includes an interactive CD-ROM with all relevant user manuals. Keep it in a safe place, and readily accessible to the user. You can also download user manu­als and updates from our website at www.leica-microsystems.com
Legal requirements
Adhere to general and local regulations rela­ting to accident prevention and environmental protection.
EC Declaration of Conformity
Electrically operated accessories are construc­ted based on the state of the art of technology and are provided with an EC Declaration of Conformity.
Leica A60 F Manual 5
Instructions on use
Intended use
The Leica A60 F stereomicroscope is an opti­cal instrument for improving the visibility of objects through magnification and illumina­tion.
The stereomicroscope may be used only in closed rooms and must be placed on a solid substrate.
The Leica A60 F stereomicroscope can be used in clean rooms.
Always position the stereomicroscope
Place of use
Use the stereomicroscope in closed, dust-free rooms at +10°C to +40 °C. Protect it from oil, chemicals and extreme humidity. Install electri­cal devices at least 10 cm from the wall and away from flammable substances.
In warm and warm-damp climatic zones,
the individual components require special care in order to prevent the build-up of fungus.
Non-intended use
Using the stereomicroscope in any way
other than that described in the user manual may result in personal injury or damage to property. Doing so can impair the functions of the protective measures provided.
Never install any other plug (NEMA
5-15P) or unscrew any mechanical components unless expressly instructed to do so in the instructions.
The instruments and accessories descri-
bed in this user manual have been tested
for safety and potential hazards.
Leica A60 F Manual 6
Instructions on use (continued)
The responsible Leica affiliate must be
consulted whenever the instrument is altered, modified or used in conjunction with non-Leica components that are outside of the scope of this manual!
ment or noncompliant use shall void all rights to any warranty claims.
Transport
If at all possible, use the original packaging for shipping or transporting individual modules.
In order to prevent damage from vibrations, the customer should disassemble all moving parts according to the user manual and pack them separately.
Disposal
Disposal must comply with locally applicable laws and regulations.
Integration in third-party products
When installing Leica products into third-party products, the manufacturer of the complete system or its dealer is responsible for following all applicable safety instructions, laws and guidelines.
Leica A60 F Manual 7
Health risks and dangers of use
Health risks
Workplaces with stereomicroscopes faci-
litate and improve the viewing task, but they also impose high demands on the eyes and holding muscles of the user. Depending on the duration of uninterrupted work at such a workplace, impaired vision and problems with the musculoskeletal system may occur. For this reason, appropriate measures for reduction of the workload must be taken:
Ϙ Optimum workplace layout
Ϙ Frequent changes of activity
Ϙ Thorough training of the personnel, giving
consideration to ergonomic and organiza­tional aspects
The ergonomic optical design and construction of the Leica stereomicroscopes are intended to reduce the exertion of the user to a minimum.
Danger of infection
Direct contact with eyepieces is a
potential transmission method for
bacterial and viral infections of the eye.
The risk can be kept to a minimum by
using personal eyepieces for each indivi-
dual or detachable eyecups.
Dangers during use
Ϙ The stereomicroscope must be connected
to a grounded outlet.
Ϙ The stereomicroscope may be used when it
is in proper working condition only.
Leica A60 F Manual 8
Information for the person responsible for the instrument
Information for the person responsible for the instrument
Ϙ Ensure that the stereomicroscope is used
only by persons qualified to do so.
Ϙ Ensure that this manual is always available
at the place where the stereomicroscope is in use.
Ϙ Carry out regular inspections to make
certain that the authorized users are adhering to safety requirements.
Ϙ When instructing new users, do so
thoroughly and explain the meanings of the warning signs and messages.
Ϙ Assign individual responsibilities for star-
ting, operating and servicing the instru­ment and monitor the observance of these responsibilities.
Ϙ Only use the stereomicroscope in proper
condition.
Ϙ Inform your Leica representative or Leica
Microsystems (Schweiz) AG, Industry Divi­sion, 9435 Heerbrugg, Switzerland, imme­diately of any product defect that could potentially cause injury or harm.
Ϙ If you use accessories from other manu-
facturers with the stereomicroscope, make sure that these manufacturers confirm that the combination is safe to use. Follow the instructions in the user manual for those accessories.
Ϙ Modifications to or service on the stereo-
microscope may be carried out only by technicians who are explicitly authorized by Leica to do so.
Ϙ Only original Leica replacement parts may
be used in servicing the product.
Ϙ After service work or technical modifica-
tions, the device must be readjusted in accordance with our technical specifica­tions.
Ϙ If the unit is modified or serviced by
unauthorized persons, is improperly maintained (as long as maintenance was not carried out by us), or is handled impro­perly, Leica will not accept any liability.
Ϙ The electric installation in the building
must conform to the national standard, e.g. current-operated ground leakage protec­tion (fault-current protection) is suggested.
Leica A60 F Manual 9
Care instructions
General Instructions
Ϙ Protect the stereomicroscope from mois-
ture, fumes and acids and from alkaline, caustic and corrosive materials. Do not store chemicals in the vicinity.
Ϙ Protect the stereomicroscope from oil and
grease. Never grease or oil mechanical parts or sliding surfaces.
Ϙ Follow the instructions of the disinfectant
manufacturer.
Ϙ We recommend concluding a service
contract with Leica Service.
Cleaning coated parts and plastic parts
Ϙ Dust and dirt particles should be removed
with a soft brush or lint-free cotton cloth.
Ϙ Remove coarse debris with a moistened
disposable cloth.
Ϙ Acetone, xylene or nitro-containing thin-
ners must NOT be used.
Ϙ Never use chemicals to clean colored
surfaces or accessories with rubberized parts. This could damage the surfaces, and specimens could be contaminated by abra­ded particles.
Cleaning glass surfaces
Ϙ Remove dust using a fine, dry and grease-
free brush made from hair, by blowing with a squeeze blower, or by using a vacuum.
Ϙ Remove dirt using a clean cloth that has
been moistened with distilled water.
Ϙ Remove tough dirt using alcohol, chloro-
form or petroleum ether.
Leica A60 F Manual 10
Loading...