LEGRAND TX3 6000 A User Manual

1/49
Telephone: +33 5 55 06 87 87 – FAX: +33 5 55 06 88 88
Circuit breaker TX3 6000 A up to 63 A (1 module per pole)
Cat. N° (s) : 4 033 49 to 4 035 68, 4 037 12 to 4 037 78
CONTENTS PAGE
1. Description - Use .................................. 1
2. Range .................................................. 1
3. Overall dimensions ............................... 1
4. Preparation - Connection ...................... 1
5. General Characteristics ........................ 3
6. Compliance and approvals .................. 35
7. Curves ................................................. 36
8. Auxiliaries and accessories ................. 49
1. DESCRIPTION - USE:
. Thermal-magnetic circuit breaker (MCB) for control, disconnection and protection of electrical circuits against overcurrents
Symbol:
Technology:
. Current limiting circuit-breaker . 1 module per pole. Each pole is 17,7 mm wide
2. RANGE
Polarity:
. 1P / 1P+N right side / 2P / 3P / 4P
Rated currents, In:
. B curve: 1 / 2 / 3 / 4 / 6 / 8 / 10 / 13 /16 / 20 / 25 / 32 / 40 / 50 / 63A . C and D curves: 0.5 / 1 / 2 / 3 / 4 / 6 / 8 / 10 / 13 /16 / 20 / 25 / 32 / 40 / 50 / 63A
Magnetic tripping curves:
. B Curve (between 3 and 5 In) . C Curve (between 5 and 10 In) . D Curve (between 10 In and 17 In)
Thermal threshold according to IEC/EN 60898-1:
. Non operating current (Inf): 1.13 In. . Operating current (If): 1.45 In.
Rated Voltage and Frequency:
. 240 V ~ / 415 V~ - 50 / 60 Hz with standard tolerances. . 80 V per pole DC current.
Maximum operating voltage:
. 440 V ~ with possible derating of the breaking capacity
Breaking capacity:
. 6000 A in accordance with standard IEC/EN 60898-1
3. OVERALL DIMENSIONS:
X 1P
17.7 mm
1P+N / 2P
35.4 mm
3P
53.1 mm
4P
70.8 mm
4. PREPARATION - CONNECTION
Mounting
. On symmetric IEC/EN 60715 or DIN 35 rail.
Operating positions: .Vertical Horizontal Upside down On the side
Technical data sheet: F01547EN/01
Updated: 15/10/2014
Created: 30/05/2014
2/49
Circuit breaker TX3 6000 A up to 63 A (1 module per pole)
Cat. N° (s) : 4 033 49 to 4 035 68, 4 037 12 to 4 037 78
4. PREPARATION - CONNECTION
(continued)
Connection:
. Inputs and outputs via screw terminals . Cage terminals, with release and captive screws . The location of the terminals allows supplying by pin busbar both sides and fork busbar lower side.
Module maintenance :
. MCBs are equipped with a din rail clamp which facilitates the removal of the circuit-breaker from the din rail in case of maintenance or replacement without the need to disconnect the entire supply line. A circuit breaker may be replaced in the middle of a supplied fork busbar row without disconnecting the other products.
This method is available for the 1 pole, 2-poles, 3-poles, 4-poles
devices.
4. PREPARATION - CONNECTION
(continued)
Power supply:
. Either from the top or the bottom
Terminal depth:
. 14 mm
Stripping length recommended:
. 11 mm
Screw head:
. Mixed, slotted and Pozidriv 2.
Tightening torque:
. Recommended: 2.5 Nm. . Mini: 2 Nm. Maxi: 3 Nm.
Required tools:
. For the terminals: Pozidriv n°2 or flat screwdriver 5.5 mm (6 mm
maximum). . For fixing: flat screwdriver 5.5 mm (6 mm maximum).
Connectable section:
Copper cables
Without ferrule
With ferrule
Rigid cable
1 x 1.5 mm² to 35 mm²
2 x 1.5 mm² to 16 mm²
-
Flexible cable
1 x 1.5 mm² to 25 mm²
2 x 1.5 mm² to 10 mm²
1 x 1.5 mm² to 25 mm²
Manual actuation of the MCB: . Ergonomic 2-position handle
. "I-ON": Device closed . "O-OFF": Device open
Contact status display:
. By marking of the handle
- "O-OFF" in white on a green background = contacts open
- "I-ON" in white on a red background = contacts closed
Sealing:
. Possible in ʺOpenʺ position (OFF) or ʺCloseʺ position (ON).
Locking:
. By 5 mm padlock (cat. N° 4 063 13) or 6 mm padlock (cat. N° 0 227
97) with padlock support (cat. N° 4 063 03).
Labelling:
. Identification of the circuit by insertion of a label in the label holder.
Technical data sheet: F01547EN/01
Updated: 15/10/2014
Created: 30/05/2014
Unscrew the
terminals
completely
Put the clamp in
the unlocking
position with a
screwdriver
Pull the device
upward
Pull the device
downward in order
to release it
completely from
the prongs of the
busbar. Then pull
the device forward.
3/49
Circuit breaker TX3 6000 A up to 63 A (1 module per pole)
Cat. N° (s) : 4 033 49 to 4 035 68, 4 037 12 to 4 037 78
5. GENERAL CHARACTERISTICS:
Neutral earthing system:
. IT, ITT, TN
Marking on the front side: . By permanent ink pad printing:
- Trade name: TX
3
- Breaking curve
- Rated current (in A)
- Icn in A rated breaking capacity in accordance with
IEC/EN 60898-1 (in a box)
- Limiting class “3” ( in a square) [no for D curve]
- Legrand reference code, and Logo .
- Brand: Legrand.
Short-circuit breaking capacity:
. Alternate current 50/60Hz, single-phase or three-phase network, in accordance with standard: IEC/EN 60898-1
Un 1P
1P+N / 2P
3P / 4P
110 V~
Icn
10000 A
16000 A
-
230 V~
6000 A
10000 A
10000 A
400 V~ - 6000 A
6000 A
440 V~ - 4500 A
4500 A
110 V~
Ics
75% of Icn
75% of Icn
75% of Icn
230 V~
400 V~
440 V~
Short-circuit breaking capacity of only one pole:
. Three-phase network 220 / 380 V~ to 240 / 415 V~
- in TN neutral system, Icn1 = 10 kA (under 220 to 240 V~)
- in IT neutral system, Iit = 3 kA (under 380 to 415 V~)
. Three-phase network 110 / 220 V~ to 120 / 240 V~
- in TN neutral system, Icn1 = 25 kA (under 110 to 127 V~)
- in IT neutral system, Iit = 6 kA (under 220 to 240 V~)
Minimum operating voltage:
. 12 V a.c. / d.c. per pole.
Pulse rated voltage:
. Uimp = 4 kV
Insulation rated voltage:
. Ui = 500 V
5. GENERAL CHARACTERISTICS
(continued)
Pollution degree :
. 2 in accordance with standard IEC/EN 60898-1.
Electric strength:
. 2500 V
Operation at 400 Hz:
. The magnetic thresholds increase by 45%.
Load to close and to open a pole trough the handle:
. 0.1 Nm per pole to close. . 0.075 Nm per pole to open.
Mechanical endurance:
. 20000 operations without load. . 10000 operations with load (under In*cos = 0.9). . 2000 operations under In, DC current.
Enclosure material:
. Polyester. . Characteristics of this material: self extinguishing, heat and fire resistant according to EN 60898-1, glow-wire test at 960°C for external parts made of insulating material necessary to retain in position current­carrying parts and parts of protective circuit (650°C for all other external parts made of insulating material).
Average weight per pole:
. 0.150 kg.
Volume when packed:
Volume (dm³)
Single pole (packed per 10)
1.628
Double pole & 1P+N
(packed per 5)
1.628
Triple pole / Four pole
0.720
Ambient temperatures:
. Operation: from – 25 ℃ to + 70 ℃ . Storage: from – 40 ℃ to + 70 ℃
Degree or class of protection:
. Protection index of terminals against solid and liquid bodies: IP 20 (wired terminals), (in accordance with standards IEC 529, EN 60529 and NF C 20-010). . Protection index of the box against solid and liquid bodies: IP 40 (in accordance with standards IEC 529, EN 60529 and NF C 20-010). . Protection index against mechanical shocks: IK 02 (in accordance with standards EN 50102 and NF C 20-015).
Technical data sheet: F01547EN/01
Updated: 15/10/2014
Created: 30/05/2014
4/49
Circuit breaker TX3 6000 A up to 63 A (1 module per pole)
Cat. N° (s) : 4 033 49 to 4 035 68, 4 037 12 to 4 037 78
5. GENERAL CHARACTERISTICS
(continued)
Sinusoidal vibration resistance in accordance with IEC 60068.2.6:
. Axis: x, y, z.
. Frequency range: 5÷100 Hz ; duration 90 minutes . Displacement (5÷13,2 Hz) : 1mm . Acceleration (13,2÷100 Hz) : 0,7 (g=9,81 m/s2)
Power dissipated per pole (W) :
. Circuit breaker B curve
In
1 A
2 A
3 A
4 A
6 A
8 A
10 A
1P÷4P
2 2 2
2
1.1
1.4
1.8
In
13 A
16 A
20 A
25 A
32 A
40 A
50 A
1P÷4P
1.9 2 2.2
2.7
3.2 4 4.5
In
63A
1P÷4P
5.5
. Circuit breaker C & D curves
In
0.5 A
1 A
2 A
3 A
4 A
6 A
8 A
1P÷4P
1.7 2 2
2 2 1.1
1.4
In
10 A
13 A
16 A
20 A
25 A
32 A
40 A
1P÷4P
1.8
1.9
2
2.2
2.7
3.2
4
In
50 A
63A
1P÷4P
4.5
5.5
. Impedance per pole (Ω) = P dissipated
In2
Technical data sheet: F01547EN/01
Updated: 15/10/2014
Created: 30/05/2014
5/49
Circuit breaker TX3 6000 A up to 63 A (1 module per pole)
Cat. N° (s) : 4 033 49 to 4 035 68, 4 037 12 to 4 037 78
5. GENERAL CHARACTERISTICS
(continued):
Derating of circuit-breakers according to ambient temperature :
. The nominal characteristics of a circuit breaker are modified according to the ambient temperature inside the cabinet or the enclosure where the circuit breaker is located. . Reference temperature: 30 °C in accordance with IEC/EN 60898-1
Ambient Temperature / In
In (A)
- 25°C
- 10°C
0°C
10°C
20°C
30°C
40°C
50°C
60°C
70°C
0,5
0.62
0.6
0.57
0.55
0.52
0.5
0.47
0.42
0.40
0.38
1
1.5
1.4
1.3
1.2
1.1 1 0.9
0.8
0.7
0.6 2 2.8
2.6
2.5
2.3
2.2 2 2
1.9
1.8
1.7 3 3.8
3.6
3.5
3.3
3.2
3.0
2.9
2.8
2.7
2.6 4 4.5
4.2
4.0
3.9
3.7
3.5
3.4
3.3
3.2
3.1 6 7.5
7.0
6.6
6.4
6.2
6.0
5.8
5.6
5.4
5.3
8
9.6
9.2
8.9
8.6
8.3 8 7.8
7.5
7.3
7
10
12.5
11.5
11.1
10.7
10.3
10.0
9.7
9.3
9.0
8.7
13
16.3
15
14.3
13.9
13.4
13
12.6
12.1
11.7
11.3
16
20.0
18.7
18.0
17.3
16.6
16.0
15.4
14.7
14.1
13.5
20
25.0
23.2
22.4
21.6
20.8
20.0
19.2
18.4
17.6
16.8
25
31.5
29.5
28.3
27.2
26.0
25.0
24.0
22.7
21.7
20.7
32
41.0
37.8
36.5
34.9
33.3
32.0
30.7
29.1
27.8
26.5
40
51.0
48.0
46.0
44.0
42.0
40.0
38.0
36.0
34.0
32.0
50
64.0
60.0
57.5
55.0
52.5
50.0
47.5
45.0
42.5
40.0
63
80.6
75.6
72.5
69.9
66.1
63.0
59.8
56.1
52.9
49.7
Derating of MCB for use with fluorescent lights:
Ferromagnetic and electronic ballasts have a high inrush current for a short time. These currents can cause the tripping of circuit breakers. At the time of the installation, it should take into account the maximum number of ballasts per circuit breaker that the manufacturers of lamps and ballasts indicate in their catalogues.
Influence of the altitude:
≤2000 m
3000 m
4000 m
5000 m
Dielectric holding
3000 V
2500 V
2000 V
1500 V
Max operational Voltage
400 V
400 V
400 V
400 V
Derating at 30°C
none
none
none
none
Derating of MCBs function of the number of devices side by side:
When several MCBs are juxtaposed and operate simultaneously, the thermal evacuation of the poles is limited. This results in an increase in operating temperature of the circuit breakers which can cause unwanted tripping. It is recommended to apply the following coefficients to the rated currents.
Number of circuit breakers
side by side
Coefficient
2 - 3
0.9
4 – 5
0.8
6 - 9
0.7
10
0.6
These values are given by the recommendation of IEC 61439-1, NF C 63421 and EN 61439-1 standards. To avoid using these coefficients, it is necessary to allow a good ventilation and to separate the devices with 0.5 module spacing elements (cat. N° 4 063 07).
Technical data sheet: F01547EN/01
Updated: 15/10/2014
Created: 30/05/2014
6/49
Circuit breaker TX3 6000 A up to 63 A (1 module per pole)
Cat. N° (s) : 4 033 49 to 4 035 68, 4 037 12 to 4 037 78
5. GENERAL CHARACTERISTICS
(continued):
Coordination between circuit-breakers and fuses, three-phase network (+ neutal) 400 / 415 V~ according to IEC/EN 60947-2:
For TT or TN neutral system in 230/400 V network, to know the breaking capacity of the combination of a double pole breaker (connected between phase and neutral under 230 V) downstream of a triple-pole circuit-breaker, take the values shown in Tables 230/400 V.
Fuse upstream
gG Type
m.c.b. downstream
≤20A
25A
32A
40A
50A
63A
80A
100A
125A
160A
TX3 6000A
B, C & D Curves
<6A
100kA
100kA
100kA
100kA
100kA
100kA
100kA
100kA
100kA
40kA
6A
100kA
100kA
100kA
100kA
100kA
100kA
100kA
100kA
100kA
40kA
10A
100kA
100kA
100kA
100kA
100kA
100kA
100kA
100kA
100kA
40kA
13A - 100kA
100kA
100kA
100kA
100kA
100kA
100kA
100kA
40kA
16A - 100kA
100kA
100kA
100kA
100kA
100kA
100kA
100kA
40kA
20A - -
100kA
100kA
100kA
100kA
100kA
100kA
100kA
40kA
25A - - - 100kA
100kA
100kA
100kA
100kA
100kA
40kA
32A - - - -
100kA
100kA
100kA
100kA
100kA
40kA
40A - - - - - 100kA
100kA
100kA
100kA
40kA
50A - - - - - -
100kA
100kA
100kA
40kA
63A - - - - - -
100kA
100kA
100kA
40kA
Fuse upstream
aM Type
m.c.b. downstream
≤20A
25A
32A
40A
50A
63A
80A
100A
125A
160A
TX3 6000A
B, C & D Curves
< 6A
100kA
100kA
100kA
100kA
100kA
100kA
100kA
100kA
100kA
40kA
6A
100kA
100kA
100kA
100kA
100kA
100kA
100kA
100kA
100kA
40kA
10A
100kA
100kA
100kA
100kA
100kA
100kA
100kA
100kA
100kA
40kA
13A - 100kA
100kA
100kA
100kA
100kA
100kA
100kA
100kA
40kA
16A - -
100kA
100kA
100kA
100kA
100kA
100kA
100kA
40kA
20A - - - 100kA
100kA
100kA
100kA
100kA
100kA
40kA
25A - - - -
100kA
100kA
100kA
100kA
100kA
40kA
32A - - - - - 100kA
100kA
100kA
100kA
40kA
40A - - - - - -
100kA
100kA
100kA
40kA
50A - - - - - -
100kA
100kA
100kA
40kA
63A - - - - - -
100kA
100kA
100kA
40kA
According to the curves and ratings of circuit breakers, attention to the threshold and size of upstream fuse which must necessarily be higher.
Technical data sheet: F01547EN/01
Updated: 15/10/2014
Created: 30/05/2014
7/49
Circuit breaker TX3 6000 A up to 63 A (1 module per pole)
Cat. N° (s) : 4 033 49 to 4 035 68, 4 037 12 to 4 037 78
5. GENERAL CHARACTERISTICS
(continued):
Coordination between modular circuit-breakers, three-phase network (+ neutal) 400 / 415 V~ according to IEC/EN 60947-2:
For TT or TN neutral system in 230/400 V network, to know the breaking capacity of the combination of a double pole breaker (connected between phase and neutral under 230 V) downstream of a triple-pole circuit-breaker, take the values shown in Tables 230/400 V.
m.c.b. upstream
DX3 6000A/10kA
B and C Curves
D Curve
m.c.b. downstream
≤25A
32A
40A
50A
63A
≤25A
32A
40A
50A
63A
TX3 6000A
B, C & D Curves
<6A
10kA
10kA
10kA
10kA
10kA
10kA
10kA
10kA
10kA
10kA
6A
10kA
10kA
10kA
10kA
10kA
10kA
10kA
10kA
10kA
10kA
10A
10kA
10kA
10kA
10kA
10kA
10kA
10kA
10kA
10kA
10kA
13A
10kA
10kA
10kA
10kA
10kA
10kA
10kA
10kA
10kA
10kA
16A
10kA
10kA
10kA
10kA
10kA
10kA
10kA
10kA
10kA
10kA
20A
10kA
10kA
10kA
10kA
10kA
10kA
10kA
10kA
10kA
10kA
25A - 10kA
10kA
10kA
10kA - 10kA
10kA
10kA
10kA
32A - -
10kA
10kA
10kA - -
10kA
10kA
10kA
40A - - - 10kA
10kA - - - 10kA
10kA
50A - - - -
10kA - - - -
10kA
63A - - - - - - - - - -
m.c.b. upstream
TX3 10000A
B Curve
C Curve
m.c.b. downstream
≤25A
32A
40A
50A
63A
≤25A
32A
40A
50A
63A
TX3 6000A
B, C & D Curves
<6A
10kA
10kA
10kA
10kA
10kA
10kA
10kA
10kA
10kA
10kA
6A
10kA
10kA
10kA
10kA
10kA
10kA
10kA
10kA
10kA
10kA
10A
10kA
10kA
10kA
10kA
10kA
10kA
10kA
10kA
10kA
10kA
13A
10kA
10kA
10kA
10kA
10kA
10kA
10kA
10kA
10kA
10kA
16A
10kA
10kA
10kA
10kA
10kA
10kA
10kA
10kA
10kA
10kA
20A
10kA
10kA
10kA
10kA
10kA
10kA
10kA
10kA
10kA
10kA
25A - 10kA
10kA
10kA
10kA - 10kA
10kA
10kA
10kA
32A - -
10kA
10kA
10kA - -
10kA
10kA
10kA
40A - - - 10kA
10kA - - - 10kA
10kA
50A - - - -
10kA - - - -
10kA
63A - - - - - - - - - -
According to the curves and ratings of circuit breakers, attention to the magnetic threshold and to the size of upstream circuit breakers which must necessarily be higher.
Technical data sheet: F01547EN/01
Updated: 15/10/2014
Created: 30/05/2014
8/49
Circuit breaker TX3 6000 A up to 63 A (1 module per pole)
Cat. N° (s) : 4 033 49 to 4 035 68, 4 037 12 to 4 037 78
5. GENERAL CHARACTERISTICS
(continued):
Coordination between modular circuit-breakers, three-phase network (+ neutal) 400 / 415 V~ according to IEC/EN 60947-2:
For TT or TN neutral system in 230/400 V network, to know the breaking capacity of the combination of a double pole breaker (connected between phase and neutral under 230 V) downstream of a triple-pole circuit-breaker, take the values shown in Tables 230/400 V.
m.c.b. upstream
DX3 10000/16kA
B and C Curves
B, C and D Curve
m.c.b. downstream
≤25A
32A
40A
50A
63A
80A
100A
125A
TX3 6000A
B, C & D Curves
<6A
16kA
16kA
16kA
16kA
16kA
16kA
16kA
16kA
6A
16kA
16kA
16kA
16kA
16kA
16kA
16kA
16kA
10A
16kA
16kA
16kA
16kA
16kA
16kA
16kA
16kA
13A
16kA
16kA
16kA
16kA
16kA
16kA
16kA
16kA
16A
16kA
16kA
16kA
16kA
16kA
16kA
16kA
16kA
20A
16kA
16kA
16kA
16kA
16kA
16kA
16kA
16kA
25A - 16kA
16kA
16kA
16kA
16kA
16kA
16kA
32A - -
16kA
16kA
16kA
16kA
16kA
16kA
40A - - - 16kA
16kA
16kA
16kA
16kA
50A - - - -
16kA
16kA
16kA
16kA
63A - - - - - 16kA
16kA
16kA
m.c.b. upstream
DX3 25kA
B, C and D Curves
m.c.b. downstream
≤25A
32A
40A
50A
63A
80A
100A
125A
TX3 6000A
B, C & D Curves
<6A
16kA
16kA
16kA
16kA
16kA
16kA
16kA
16kA
6A
16kA
16kA
16kA
16kA
16kA
16kA
16kA
16kA
10A
16kA
16kA
16kA
16kA
16kA
16kA
16kA
16kA
13A
16kA
16kA
16kA
16kA
16kA
16kA
16kA
16kA
16A
16kA
16kA
16kA
16kA
16kA
16kA
16kA
16kA
20A
16kA
16kA
16kA
16kA
16kA
16kA
16kA
16kA
25A - 16kA
16kA
16kA
16kA
16kA
16kA
16kA
32A - -
16kA
16kA
16kA
16kA
16kA
16kA
40A - - - 16kA
16kA
16kA
16kA
16kA
50A - - - -
16kA
16kA
16kA
16kA
63A - - - - - 16kA
16kA
16kA
According to the curves and ratings of circuit breakers, attention to the magnetic threshold and to the size of upstream circuit breakers which must necessarily be higher.
Technical data sheet: F01547EN/01
Updated: 15/10/2014
Created: 30/05/2014
9/49
Circuit breaker TX3 6000 A up to 63 A (1 module per pole)
Cat. N° (s) : 4 033 49 to 4 035 68, 4 037 12 to 4 037 78
5. GENERAL CHARACTERISTICS
(continued):
Coordination between modular circuit-breakers, three-phase network (+ neutal) 400 / 415 V~ according to IEC/EN 60947-2:
For TT or TN neutral system in 230/400 V network, to know the breaking capacity of the combination of a double pole breaker (connected between phase and neutral under 230 V) downstream of a triple-pole circuit-breaker, take the values shown in Tables 230/400 V.
m.c.b. upstream
DX3 36kA
DX3 50kA
C Curve
B, C and D Curves
m.c.b. downstream
≤25A
32A
40A
50A
63A
80A
≤25A
32A
40A
50A
63A
TX3 6000A
B, C & D Curves
<6A
25kA
25kA
25kA
25kA
25kA
25kA
36kA
36kA
36kA
36kA
36kA
6A
25kA
25kA
25kA
25kA
25kA
25kA
36kA
36kA
36kA
36kA
36kA
10A
25kA
25kA
25kA
25kA
25kA
25kA
36kA
36kA
36kA
36kA
36kA
13A
25kA
25kA
25kA
25kA
25kA
25kA
36kA
36kA
36kA
36kA
36kA
16A
25kA
25kA
25kA
25kA
25kA
25kA
36kA
36kA
36kA
36kA
36kA
20A
25kA
25kA
25kA
25kA
25kA
25kA
36kA
36kA
36kA
36kA
36kA
25A - 25kA
25kA
25kA
25kA
25kA - 36kA
36kA
36kA
36kA
32A - -
25kA
25kA
25kA
25kA - -
36kA
36kA
36kA
40A - - - 25kA
25kA
25kA - - - 36kA
36kA
50A - - - -
25kA
25kA - - - -
36kA
63A - - - - - 25kA - - - -
-
According to the curves and ratings of circuit breakers, attention to the magnetic threshold and to the size of upstream circuit breakers which must necessarily be higher.
Technical data sheet: F01547EN/01
Updated: 15/10/2014
Created: 30/05/2014
10/49
Circuit breaker TX3 6000 A up to 63 A (1 module per pole)
Cat. N° (s) : 4 033 49 to 4 035 68, 4 037 12 to 4 037 78
5. GENERAL CHARACTERISTICS
(continued):
Coordination between modular circuit-breakers and MCCBs, three-phase network (+ neutal) 400 / 415 V~ according to IEC/EN 60947-2:
For TT or TN neutral system in 230/400 V network, to know the breaking capacity of the combination of a double pole breaker (connected between phase and neutral under 230 V) downstream of a triple-pole circuit-breaker, take the values shown in Tables 230/400 V.
m.c.c.b. upstream
DPX 125
16kA
m.c.b. downstream
16A
25A
40A
63A
100A
125A
TX3 6000A
B, C & D Curves
<6A
16kA
16kA
16kA
16kA
16kA
16kA
6A
16kA
16kA
16kA
16kA
16kA
16kA
10A
16kA
16kA
16kA
16kA
16kA
16kA
13A
16kA
16kA
16kA
16kA
16kA
16kA
16A - 16kA
16kA
16kA
16kA
16kA
20A - 16kA
16kA
16kA
16kA
16kA
25A - -
16kA
16kA
16kA
16kA
32A - -
16kA
16kA
16kA
16kA
40A - - - 16kA
16kA
16kA
50A - - - 16kA
16kA
16kA
63A - - - -
16kA
16kA
m.c.c.b. upstream
DPX 125
25 – 36kA
m.c.b. downstream
16A
25A
40A
63A
100A
125A
TX3 6000A
B, C & D Curves
<6A
25kA
25kA
25kA
25kA
25kA
25kA
6A
25kA
25kA
25kA
25kA
25kA
25kA
10A
25kA
25kA
25kA
25kA
25kA
25kA
13A
25kA
25kA
25kA
25kA
25kA
25kA
16A - 25kA
25kA
25kA
25kA
25kA
20A - 25kA
25kA
25kA
25kA
25kA
25A
-
-
25kA
25kA
25kA
25kA
32A
-
-
25kA
25kA
25kA
25kA
40A
- - -
25kA
25kA
25kA
50A
- - -
25kA
25kA
25kA
63A
- - -
-
25kA
25kA
According to the curves and ratings of circuit breakers, attention to the magnetic threshold and to the size of upstream circuit breakers which must necessarily be higher.
Technical data sheet: F01547EN/01
Updated: 15/10/2014
Created: 30/05/2014
11/49
Circuit breaker TX3 6000 A up to 63 A (1 module per pole)
Cat. N° (s) : 4 033 49 to 4 035 68, 4 037 12 to 4 037 78
5. GENERAL CHARACTERISTICS
(continued):
Coordination between modular circuit-breakers and MCCBs, three-phase network (+ neutal) 400 / 415 V~ according to IEC/EN 60947-2:
For TT or TN neutral system in 230/400 V network, to know the breaking capacity of the combination of a double pole breaker (connected between phase and neutral under 230 V) downstream of a triple-pole circuit-breaker, take the values shown in Tables 230/400 V.
m.c.c.b. upstream
DPX3 160 / DPX3 160 + RCD
16kA
m.c.b. downstream
16A
25A
40A
63A
80A
100A
125A
160A
TX3 6000A
B, C & D Curves
<6A
16kA
16kA
16kA
16kA
16kA
16kA
16kA
16kA
6A
16kA
16kA
16kA
16kA
16kA
16kA
16kA
16kA
10A
16kA
16kA
16kA
16kA
16kA
16kA
16kA
16kA
13A
16kA
16kA
16kA
16kA
16kA
16kA
16kA
16kA
16A - 16kA
16kA
16kA
16kA
16kA
16kA
16kA
20A - 16kA
16kA
16kA
16kA
16kA
16kA
16kA
25A - -
16kA
16kA
16kA
16kA
16kA
16kA
32A - -
16kA
16kA
16kA
16kA
16kA
16kA
40A - - - 16kA
16kA
16kA
16kA
16kA
50A - - - 16kA
16kA
16kA
16kA
16kA
63A - - - -
16kA
16kA
16kA
16kA
m.c.c.b. upstream
DPX3 160 / DPX3 160 + RCD
25 – 36 – 50kA
m.c.b. downstream
16A
25A
40A
63A
80A
100A
125A
160A
TX3 6000A
B, C & D Curves
<6A
25kA
25kA
25kA
25kA
25kA
25kA
25kA
25kA
6A
25kA
25kA
25kA
25kA
25kA
25kA
25kA
25kA
10A
25kA
25kA
25kA
25kA
25kA
25kA
25kA
25kA
13A
25kA
25kA
25kA
25kA
25kA
25kA
25kA
25kA
16A - 25kA
25kA
25kA
25kA
25kA
25kA
25kA
20A - 25kA
25kA
25kA
25kA
25kA
25kA
25kA
25A
-
-
25kA
25kA
25kA
25kA
25kA
25kA
32A
-
-
25kA
25kA
25kA
25kA
25kA
25kA
40A
- - -
25kA
25kA
25kA
25kA
25kA
50A
- - -
25kA
25kA
25kA
25kA
25kA
63A
- - -
-
25kA
25kA
25kA
25kA
According to the curves and ratings of circuit breakers, attention to the magnetic threshold and to the size of upstream circuit breakers which must necessarily be higher.
Technical data sheet: F01547EN/01
Updated: 15/10/2014
Created: 30/05/2014
12/49
Circuit breaker TX3 6000 A up to 63 A (1 module per pole)
Cat. N° (s) : 4 033 49 to 4 035 68, 4 037 12 to 4 037 78
5. GENERAL CHARACTERISTICS
(continued):
Coordination between modular circuit-breakers and MCCBs, three-phase network (+ neutal) 400 / 415 V~ according to IEC/EN 60947-2:
For TT or TN neutral system in 230/400 V network, to know the breaking capacity of the combination of a double pole breaker (connected between phase and neutral under 230 V) downstream of a triple-pole circuit-breaker, take the values shown in Tables 230/400 V.
m.c.c.b. upstream
DPX 250ER
DPX3 250 / DPX3 250 +RCD
(Thermal-magnetic & electronic)
25 - 36 - 50kA
25 - 36 – 50 - 70kA
m.c.b. downstream
100A
160A
250A
100A
160A
200A
250A
TX3 6000A
B, C & D Curves
<6A
25kA
25kA
25kA
25kA
25kA
25kA
25kA
6A
25kA
25kA
25kA
25kA
25kA
25kA
25kA
10A
25kA
25kA
25kA
25kA
25kA
25kA
25kA
13A
25kA
25kA
25kA
25kA
25kA
25kA
25kA
16A
25kA
25kA
25kA
25kA
25k
25kA
25kA
20A
25kA
25kA
25kA
25kA
25kA
25kA
25kA
25A
25kA
25kA
25kA
25kA
25kA
25kA
25kA
32A
25kA
25kA
25kA
25kA
25kA
25kA
25kA
40A
25kA
25kA
25kA
25kA
25kA
25kA
25kA
50A
25kA
25kA
25kA
25kA
25kA
25kA
25kA
63A
20kA
20kA
20kA
25kA
25kA
25kA
25kA
m.c.c.b. upstream
DPX / H / L 250
(Thermal-magnetic & electronic)
DPX / H / L 630
(Thermal-magnetic & electronic)
36 – 70 – 100kA
36 – 70 – 100kA
m.c.b. downstream
25A
40A
63A
100A
160A
250A
250A
320A
400A
500A
630A
TX3 6000A
B, C & D Curves
<6A
25kA
25kA
25kA
25kA
25kA
25kA
25kA
25kA
25kA
25kA
25kA
6A
25kA
25kA
25kA
25kA
25kA
25kA
25kA
25kA
25kA
25kA
25kA
10A
25kA
25kA
25kA
25kA
25kA
25kA
25kA
25kA
25kA
25kA
25kA
13A
25kA
25kA
25kA
25kA
25kA
25kA
25kA
25kA
25kA
25kA
25kA
16A
25kA
25kA
25kA
25kA
25k
25kA
25kA
25kA
25kA
25kA
25kA
20A
25kA
25kA
25kA
25kA
25kA
25kA
25kA
25kA
25kA
25kA
25kA
25A - 25kA
25kA
25kA
25kA
25kA
25kA
25kA
25kA
25kA
25kA
32A - 25kA
25kA
25kA
25kA
25kA
25kA
25kA
25kA
25kA
25kA
40A - -
25kA
25kA
25kA
25kA
20kA
20kA
20kA
20kA
20kA
50A - -
25kA
25kA
25kA
25kA
16kA
16kA
16kA
16kA
16kA
63A - - - 25kA
25kA
25kA
16kA
16kA
16kA
16kA
16kA
According to the curves and ratings of circuit breakers, attention to the magnetic (or electronic) threshold and to the size of upstream circuit breakers which must necessarily be higher.
Technical data sheet: F01547EN/01
Updated: 15/10/2014
Created: 30/05/2014
13/49
Circuit breaker TX3 6000 A up to 63 A (1 module per pole)
Cat. N° (s) : 4 033 49 to 4 035 68, 4 037 12 to 4 037 78
5. GENERAL CHARACTERISTICS
(continued):
Coordination between modular circuit-breakers and MCCBs, three-phase network (+ neutal) 400 / 415 V~ according to IEC/EN 60947-2:
For TT or TN neutral system in 230/400 V network, to know the breaking capacity of the combination of a double pole breaker (connected between phase and neutral under 230 V) downstream of a triple-pole circuit-breaker, take the values shown in Tables 230/400 V.
m.c.c.b.. upstream
DPX / H / L 1250
(Thermal -magnetic)
DPX / H 1600
(electronic)
50 – 70 – 100kA
36 – 70kA
m.c.b. downstream
500 to 1250A
630 to 1600A
TX3 6000A
B, C & D Curves
<6A
25kA
25kA
6A
25kA
25kA
10A
25kA
25kA
13A
25kA
25kA
16A
25kA
25kA
20A
25kA
25kA
25A
20kA
20kA
32A
15kA
15kA
40A
15kA
15kA
50A
12.5kA
12.5kA
63A
12.5kA
12.5kA
According to the curves and ratings of circuit breakers, attention to the magnetic (or electronic) threshold and to the size of upstream circuit breakers which must necessarily be higher.
Technical data sheet: F01547EN/01
Updated: 15/10/2014
Created: 30/05/2014
14/49
Circuit breaker TX3 6000 A up to 63 A (1 module per pole)
Cat. N° (s) : 4 033 49 to 4 035 68, 4 037 12 to 4 037 78
5. GENERAL CHARACTERISTICS
(continued):
Coordination between modular circuit-breakers and fuses, three-phase network (+ neutal) 230 / 240 V~ according to IEC/EN 60947-2:
Fuse upstream
gG Type
m.c.b. downstream
≤20A
25A
32A
40A
50A
63A
80A
100A
125A
160A
TX3 6000A
B, C & D Curves
<6A
100kA
100kA
100kA
100kA
100kA
100kA
100kA
100kA
100kA
40kA
6A
100kA
100kA
100kA
100kA
100kA
100kA
100kA
100kA
100kA
40kA
10A
100kA
100kA
100kA
100kA
100kA
100kA
100kA
100kA
100kA
40kA
13A
100kA
100kA
100kA
100kA
100kA
100kA
100kA
100kA
100kA
40kA
16A - 100kA
100kA
100kA
100kA
100kA
100kA
100kA
100kA
40kA
20A - -
100kA
100kA
100kA
100kA
100kA
100kA
100kA
40kA
25A - - - 100kA
100kA
100kA
100kA
100kA
100kA
40kA
32A - - - -
100kA
100kA
100kA
100kA
100kA
40kA
40A - - - - - 100kA
100kA
100kA
100kA
40kA
50A - - - - - -
100kA
100kA
100kA
40kA
63A - - - - - -
100kA
100kA
100kA
40kA
Fuse upstream
aM Type
m.c.b. downstream
≤20A
25A
32A
40A
50A
63A
80A
100A
125A
160A
<6A
100kA
100kA
100kA
100kA
100kA
100kA
100kA
100kA
100kA
40kA
TX3 6000A
B, C & D Curves
6A
100kA
100kA
100kA
100kA
100kA
100kA
100kA
100kA
100kA
40kA
10A
100kA
100kA
100kA
100kA
100kA
100kA
100kA
100kA
100kA
40kA
13A
100kA
100kA
100kA
100kA
100kA
100kA
100kA
100kA
100kA
40kA
16A - 100kA
100kA
100kA
100kA
100kA
100kA
100kA
100kA
40kA
20A - -
100kA
100kA
100kA
100kA
100kA
100kA
100kA
40kA
25A - - - 100kA
100kA
100kA
100kA
100kA
100kA
40kA
32A - - - -
100kA
100kA
100kA
100kA
100kA
40kA
40A - - - - - 100kA
100kA
100kA
100kA
40kA
50A - - - - - -
100kA
100kA
100kA
40kA
63A - - - - - -
100kA
100kA
100kA
40kA
According to the curves and ratings of circuit breakers, attention to the threshold and to the size of upstream fuses which must necessarily be higher.
Technical data sheet: F01547EN/01
Updated: 15/10/2014
Created: 30/05/2014
15/49
Circuit breaker TX3 6000 A up to 63 A (1 module per pole)
Cat. N° (s) : 4 033 49 to 4 035 68, 4 037 12 to 4 037 78
5. GENERAL CHARACTERISTICS
(continued):
Coordination between modular circuit-breakers, three-phase network (+ neutal) 230 / 240 V~ according to IEC/EN 60947-2:
m.c.b. upstream
DX3 6000A/10kA
B and C Curves
D Curve
m.c.b. downstream
≤25A
32A
40A
50A
63A
≤25A
32A
40A
50A
63A
TX3 6000A
B, C & D Curves
<6A
15kA
15kA
15kA
15kA
15kA
15kA
15kA
15kA
15kA
15kA
6A
15kA
15kA
15kA
15kA
15kA
15kA
15kA
15kA
15kA
15kA
10A
15kA
15kA
15kA
15kA
15kA
15kA
15kA
15kA
15kA
15kA
13A
15kA
15kA
15kA
15kA
15kA
15kA
15kA
15kA
15kA
15kA
16A
15kA
15kA
15kA
15kA
15kA
15kA
15kA
15kA
15kA
15kA
20A
15kA
15kA
15kA
15kA
15kA
15kA
15kA
15kA
15kA
15kA
25A - 15kA
15kA
15kA
15kA - 15kA
15kA
15kA
15kA
32A - -
15kA
15kA
15kA - -
15kA
15kA
15kA
40A - - - 15kA
15kA - - - 15kA
15kA
50A - - - -
15kA - - - -
15kA
63A - - - - - - - - - -
m.c.b. upstream
TX3 10000A
B Curve
C Curve
m.c.b. downstream
≤25A
32A
40A
50A
63A
≤25A
32A
40A
50A
63A
TX3 6000A
B, C & D Curves
<6A
15kA
15kA
15kA
15kA
15kA
15kA
15kA
15kA
15kA
15kA
6A
15kA
15kA
15kA
15kA
15kA
15kA
15kA
15kA
15kA
15kA
10A
15kA
15kA
15kA
15kA
15kA
15kA
15kA
15kA
15kA
15kA
13A
15kA
15kA
15kA
15kA
15kA
15kA
15kA
15kA
15kA
15kA
16A
15kA
15kA
15kA
15kA
15kA
15kA
15kA
15kA
15kA
15kA
20A
15kA
15kA
15kA
15kA
15kA
15kA
15kA
15kA
15kA
15kA
25A - 15kA
15kA
15kA
15kA - 15kA
15kA
15kA
15kA
32A - -
15kA
15kA
15kA - -
15kA
15kA
15kA
40A - - - 15kA
15kA - - - 15kA
15kA
50A - - - -
15kA - - - -
15kA
63A - - - - - - - - - -
According to the curves and ratings of circuit breakers, attention to the magnetic threshold and to the size of upstream circuit breakers which must necessarily be higher.
Technical data sheet: F01547EN/01