Legrand MS3650 User Manual

301 Fulling Mill Road, Suite G
(
(
)
Middletown, PA 17057 Phone (800) 321-2343 / Fax (717) 702-2546 www.onqlegrand.com
INSTRUCTION / INSTALLATION SHEET evōQ™ 3000 In-Ceiling and In-Wall Speakers
IS-0242 Rev. D
1. Introduction
On-Q/Legrand offers both in-ceiling and in-wall styles of evōQ™ 3000 speakers. These two styles encompass two
(2) sizes and five (5) part numbers (as shown in Figure 1
to the right). The speakers are optimized for audio distribution (central sound). All models are 2-way speakers that feature Mica-Fiber woofers and PEI (Polyetherimide) Mylar tweeters. These speakers come with dual templates with center markings and paint rings. Optional speaker pre-construction brackets are available for all models.
(*P/N MS3652, 6.5” In-Ceiling Dual Voice Coil Speaker, is for reference only and NOT part of this instruction sheet.)
Disclaimer: Make sure you are in compliance with local building codes before installing these speakers. On-Q evōQ™ 3000 In-Wall and In-Ceiling Speakers are suitable for moisture rich environments such as bathrooms, saunas and outdoor applications.
2. Description
The On-Q/Legrand evōQ™ 3000 speakers are made of a tough semi-flexible plastic frames that feature a built in foam gasket to minimize vibration and maximize seal-ability. They also feature a perforated metal grill with an acoustically transparent scrim cloth to enhance the speakers appearance once installed speakers, except sub woofers, are paint-able. They also come with painting shields to protect the drivers while painting. These speakers are suitable for moisture rich environments. They also feature flip out tabs for easy installation and removal.
In-Ceiling Style
shown w/o grill)
In-Wall Style
shown w/o grill
6.5” – P/N MS3650 (pair) 8” – P/N MS3800 (pair) * 6.5” Dual Voice Coil – P/N MS3652 (each)
6.5” – P/N MS3651 (pair) 8” – P/N MS3801 (pair)
Figure 1
. All evóQ
3. Installation
Installation of the evōQ™ 3000 speakers is best accomplished at multiple times during new construction, at “Rough-in” before the drywall is installed, and at “Trim-out” after the drywall is installed and painted.
A. “Rough-in” steps:
NOTE: It is recommended that a minimum of 16 gauge, 2 conductor wire be used for most applications from the amplifier or volume control to the speaker. Different gauges can, and should, be used based upon the distance of the
intended run or quality of installation (see Figure 2).
Speaker Wire
Gauge Selection Chart
Distance Gauge
<10 Feet 18
10-50 Feet 16
>50 Feet 14
NOTE: All On-Q/Legrand lyriQ™ Audio components accommodate wire gauges from 18 to 14.
Figure 2
1. Run x/2 conductor (x=gauge preference) stranded speaker wire from the distribution/volume control to the speaker location (pre-wiring).
INSTRUCTION / INSTALLATION SHEET evōQ™ 3000 In-Ceiling and In-Wall Speakers
301 Fulling Mill Road, Suite G Middletown, PA 17057 Phone (800) 321-2343 / Fax (717) 702-2546 www.onqlegrand.com
2. If an On-Q Speaker Pre-Construction Bracket is to be used, skip to
Step “5” and refer to IS-0243 for detailed instructions.
3. If pre-wiring without Brackets, leave 4 to 6 feet of wire at the speakers intended location. Use a strip of cardboard stapled to the joints/studs with a hole through it as a wire place holder for the drywall installers if
installation of the speakers is intended (see Figure 3).
4. After drywall and/or painting is complete, push wire through hole, center template over hole, mark with a pencil and cut out with a dry­wall knife.
5. When using the On-Q Pre-Construction Bracket (see Figure 4), leave a coil of speaker wire on top of the
bracket coiled around the speaker mounting hole. There are clips on the corner of the bracket to secure the speaker wire. Leave enough speaker wire to be able to pull the wire through the bracket and comfortably connect the wire to the speaker after the drywall is installed. Strip off 3 inches or so of the speaker cable jacket to expose the positive and negative insulated wires. Strip 3/8-1/2 inch of insulation off of these conductors.
6. It is recommended to place insulation behind the speaker to provide some damping for the woofer driver. This will yield the best possible sound. On-Q recommends using poly-encapsulated insulation such as Johns Manville Comfort Therm®. If a defined, consistent sound is desired from both speakers in a space, blocking can be installed to yield the ideal cubic footage for each driver. Insulation would then be put in this space during speaker installation. Refer to blocking chart for
details.
7. If installing speakers in a space with an attic above it is recommended that the speakers be boxed in with 1/2 inch MDF (medium density fiber board) or plywood with insulation installed. This will provide a defined acoustic space and protect the speaker. The best possible sound will be achieved by doing this. Refer to the blocking
chart for details.
Note: Make sure you are in compliance with local building codes before installing this speaker in an attic space.
using the On-Q Pre-Construction Speaker
IS-0242 Rev. D
Figure 3
Blocking Distance
Figure 4
Loading...