INSTRUCTION / INSTALLATION SHEET Audio Interrupt Module
301 Fulling Mill Road, Suite G Middletown, PA 17057 Phone (800) 321-2343 / Fax (717) 702-2546 www.onqlegrand.com
The On-Q /Legrand Audio Interrupt Module, PN IC1001 (see Figure
1), is designed to compliment the inQuire™ Intercom System. It works
in conjunction with both the lyriQ™ Audio System and the inQuire™ Intercom System by automatically muting any music that is playing through the lyriQ™ Audio System. It allows you to hear any page, or the door chime if installed, over the inQuire™ Intercom System. If the lyriQ™ Keypad Volume Control is installed along with a lyriQ™ Local Source Input, the Audio Interrupt Module will also mute the local audio source. The lyriQ™ audio will resume at the previous volume setting approximately 15 seconds after a page and 45 seconds after a door chime.
IS-0316 Rev. C
Figure 1
2. DESCRIPTION
The Audio Interrupt Module is used to integrate our inQuire™ Intercom and our lyriQ™ Audio Systems. The Audio Interrupt Module gets connected to the inQuire™ Intercom Module, lyriQ™ System Source Input, and the lyriQ™ Audio Distribution Module using RJ45 connectors. The Audio Interru pt Module will mute the active audio from the Audio System in order to facilitate clear understanding of the Intercom Systems' communications and door chimes.
3. INSTALLATION
NOTE: Install and verify the functionality of both the inQuire™ Intercom System and the lyriQ™ Audio Distribution Module. All wiring must be terminated to TIA 568A standards.
IMPORTANT: Turn off power to the inQuire™ Intercom System and the ly riQ™ Audio Distribution Module.
A. Using a standard Category 5 patch cable, such as PN 363201-xx, plug in one end to the port on the
Audio Interrupt Module labeled INTERRUPT IN, and plug the other end into the port on the inQuire™ Intercom Module that is labeled AUDIO INTERRUPT OUT (see Figure 2).
B. Plug the Category 5 cable from the lyriQ™ Audio Main Source Input into the port on the Audio
Interrupt Module labeled SOURCE IN (see Figure 2).
C. Usi ng a standard Category 5 patch cable, plug in one end to the port on the Audio Interrupt Module
labeled OUT TO AUDIO MODULE, and plug the other end into the port on lyriQ™ Audio Distribution Module labeled SOURCE IN (see Figure 2).
D. Turn on the power to both the inQuire™ Intercom System and the lyriQ™ Audio Distribution Module
and verify correct operation.
.
©Copyright 2006 by On-Q/Legrand All Rights Reserved. Page 1 of 2
INSTRUCTION / INSTALLATION SHEET Audio Interrupt Module
301 Fulling Mill Road, Suite G Middletown, PA 17057 Phone (800) 321-2343 / Fax (717) 702-2546 www.onqlegrand.com
4. VERIFY CORRECT OPERATION
A. With audio playing on the lyriQ™ Audio System, press the TALK button on the inQuire™ Intercom
System Room Unit.
B. Your page should cause the lyriQ™ Audio System to mute, and the red LED status light on the Audio
Interrupt module will be lit.
C. The lyriQ™ A udio System will then return back to its previous volume level after approximately 15
seconds.
IS-0316 Rev. C
Figure 2
Audio Interrupt
Main Source Local Source Main Source Local Source Interrupt Time Talk is pressed mute ---------------- mute mute 15 seconds Door Chime mute ---------------- mute mute 45 Seconds
©Copyright 2006 by On-Q/Legrand All Rights Reserved. Page 2 of 2
Knob Volume Control Keypad Volume Control Both