Terminating Cat 5 Cable
1. ITEMS NEEDED
LEGRAND PRODUCTS:
364555-01 - EZ-RJ45 Modular Plug Hand Tool
363292-01 - Cat 5 Strip and Fit Tool
364554-01 - EZ-RJ45 Modular Cat5 Plug
2. INTRODUCTION
A structured wiring foundation is
the most effective way to distribute
information throughout a home. It
supports high-performance technology
through clutter-free cabling hidden
behind the walls. To ensure more
efficient installation, run a single home
run to a central distribution point and
bundle cables for access to multiple
services.
3. HOW TO STEP-BY-STEP
TOOLS & ADDITIONAL SUPPLIES:
• Wire Cutter
• Continuity Tester
• Cat 5 Cable
There are several fundamentals to
remember when working with Cat 5:
• On-Q products utilize the T568A wiring
standard
• Never splice Cat 5 cable
• Always maintain a 12-inch minimum
separation between the Cat 5 and any
120 Volt AC cabling. If you must cross
and electrical circuit, do so at a 90
degree angle
• Always maintain a minimum bend
radius of 1 inch.
• Never exceed the 25 pound pull limit.
Doing so may pull the twists out of
the wire, which is what gives Cat 5 its
immunity from interference. For the
same reason, you shouldn’t stand on
the wire or use any retention devices
that flatten out the wire.
STEP 1
Use the Strip and Fit tool to cut off
approximately two inches of the
jacket.
STEP 2
Cut the wire separator strands, separate
the pairs and untwist them.
STEP 3
Now fan them out in the T568A pattern.
White/Green
Green
White/Orange
Blue
White/Blue
Orange
White/Brown
Brown
www.legrand.us/onq
Terminating Cat 5 Cable
3. HOW TO STEP-BY-STEP CONT.
STEP 4
Lightly pinch the wires together to
prepare for seating.
STEP 7
Insert the connector into the crimp tool
and squeeze to set each of the pins.
STEP 5
Confirm that the colors match the T568A
pattern and trim so that all of the wires
line up to fit in the RJ45 connector.
STEP 8
Ensure that all eight gold pins are fully
compressed.
STEP 6
Slide the cable into the connector
ensuring that:
Only one wire goes into each seat
The pins reach the end of the connector
The gold pin ends are neatly aligned
The jacket is inside of the connector
STEP 9
We recommend that you always test the
cable for continuity – simply plug each
end into the tester and look for the green
light on each tested pair.