87045 LIMOGES Cedex
Description Characteristics
Connection
method
Weight (g) Cat. No.
Automatic switch
without neutral
2 wires
without override
230 V - 50 Hz
300 W max
110 V - 50 Hz
150 W max
230 V - 50 Hz
400 W max
230 V - 50 Hz
1000 W max
695 00
grey/white
Automatic switch
without neutral
2 wires
with override
695 01
grey/white
Automatic switch
with neutral
3 wires
without override
695 02
grey/white
Screw
screw
screw
80 g
83 g
81 g
COMPOSABLE
696 81 696 92
696 51 696 89
GREY WHITE
Cat. No.
2 versions : grey and white
695 xx
696 xx
697 xx
698 xx
Composable
Complete surface mounting
Complete flush mounting
Telephone: + 33 5 55 06 87 87 - Fax: + 33 0 5 55 06 88 88
Plexo
Automatic switches
695 00 695 01
1. TECHNICAL CHARACTERISTICS
Weatherproof wiring system designed for residential and professional
technical locations (garages, cellars, car parks, workshops and industrial kitchens, etc) as well as for outdoor applications (patios, gardens,
camp sites, etc).
Automatic switches with or without neutral with infrared detection.
2. RANGE
Cat. No(s): 695 00/01/02
CONTENTS Page
1. Technical characteristics ...........1
2. Range..........................1
3. Installation ....................1-3
4. Overall dimensions................3
5. Operation .....................3-4
6. General characteristics...........4-5
7. Maintenance.....................5
3. INSTALLATION
3.1 fSurface mounting
- by screwing back box onto support using two Ø 3 mm - Ø 4 mm
max. screws.
- to replace former Plexo 55 series
3.2 Flush mounting
- unclip plate
- With screws
on flush mounting box
- With claws
on flush mounting box
Claws can be fitted:
Cat. No. 849 00
or Cat. No. 849 01
(long claws)
Technical data sheet: F00339EN/02 Updated: 09/05/2011 Created: 30/04/2007
CONTENTS
1/5

Plexo
Automatic switches
Cat. No(s): 695 00/01/02
Technical data sheet: F00339EN/02 Updated: 09/05/2011 Created: 30/04/2007
2/5
CONTENTS
N
L
L
300 W
max.
695 00 695 01
695 00/01
695 01
695 00/01
695 00 : n = 5 max - 300 W max
695 01 : n = 9 max - 400 W max
L L L
300 /400 W
max.
N
L
L
N
L
N
L
L
400 W
max.
IR
IR
Max. : 400 W
(695 41 - 696 31)
Connection in parallel is only possible
with incandescent sources
Number of ter minals
Type of terminals
Te rminal capacity
Tool
2
Cage connectors
2 x 1.5 mm
2
or 1 x 2.5 mm
2
Flat 3.5 mm or Philips no. 1
or Pozidrive no. 1
or combined size 0
695 02
N
L
N
L
N
L
1000 W
max.
1000 W
max.
IR
Number of ter minals
Type of terminals
Te rminal capacity
Tool
3
Cage connectors
2 x 1.5 mm2
or 1 x 2.5 mm2
Flat 3.5 mm or Philips no. 1
or Pozidrive no. 1
or combined size 0
IR
(695 41 - 696 31)
3. INSTALLATION (continued)
- On solid faceplate using four Ø 4 mm screws.
Drill support material (diameter 60 - 70 mm) using hole saw or hole
punch.0
3.3 Conductor connection
3.3.1- 2 wire mechanisms 695 00/01
3.3 Conductor connection (continued)
3.3.2 - 3 wire mechanisms 695 02
3.4 Conduit connection
Type of conduit:
- IRL: formerly IRO, insulating rigid smooth tube
- ICA: insulating flexible bendable corrugated tube
- ICTA: insulating flexible transversally bendable
elastic corrugated conduit
- ICTL: insulating flexible transversally bendable -
elastic smooth conduit
Ø 16
- 25 mm
}
Cables (examples):
- rigid conductors: U - 1000R2V 3G2.5
- flexible conductors: H07 RN - F 3G2.5
Type of entry gland: flexible with membrane, 2 removable types.
- entry gland with 1 entry supplied with 1-gang box (top and bottom)
- entry gland with 1 entry supplied with 2-gang and 3-gang boxes (top)
- entry gland with 2 entries supplied with 2-gang and 3-gang boxes
(bottom).

Cat. No(s): 695 00/01/02
Technical data sheet: F00339EN/02 Updated: 09/05/2011 Created: 30/04/2007
3/5
Plexo
Automatic switches
CONTENTS
86
86
21
31( 695 01)
36 (695 00/02)
80
84
20
65 (695 01)
70 (695 00/02)
64
51 (69501)
57 (695 00/02)
64
Ø 4 - Ø 15 mm Ø 16/20/25 mm
15 m
2.5 m
1.2 m
45°
130°
15 m
6 s6 mn
6 s6 mn
1000 lux. 3 lux.
3. INSTALLATION (continued)
3.4 Conduit connection (continued)
Also available as accessories:
- 695 96 grey entry gland 1 entry
- 695 99 grey entry gland 2 entries
- 696 46 white entry gland 1 entry
- 696 49 white entry gland 2 entries
3.5 Assembly
4. DIMENSIONS
Composable
Surface mounting
Flush mounting
5. OPERATION
5.1 Detection 695 00
IP55 sealing of the front part (cover) on the box is ensured by rotating
four 1/4 turn fixings.

Plexo
Automatic switches
Cat. No(s): 695 00/01/02
Technical data sheet: F00339EN/02 Updated: 09/05/2011 Created: 30/04/2007
4/5
CONTENTS
4 m
4 m
1.2 m
10 m
1.5 m
4 m
10 m
10 m
5. OPERATION (continued)
5.2 Detection 695 01/02
Sulphuric acid.................................. +
Tannic acid *................................... -
Tartaric acid * .................................. +
Ethanol ....................................... +
Isopropyl alcohol ............................... +
Methyl alcohol (methanol) ........................ -
Phenylethylalcohol (100%)........................ -
Ammonia ..................................... +
Baths for electroplating:
130°
- Bright silver bath .............................. +
- Bright cadmium bath ........................... +
- Chromium plating bath (50°C) .................... +
- Copper bath (with potassium cyanide) ............. +
- Copper bath (acid) ............................. +
- Pickling bath with chemical copper plating .......... +
- Brass bath ................................... +
- Bright nickel bath .............................. +
Barium
- Barium chloride * .............................. +
- Barium hydroxide *............................. +
- Barium nitrate * ............................... -
Benzene ...................................... -
Beer ......................................... +
Calcium hypochlorite * ........................... +
Cobalt chloride * ................................ -
Cupric chloride * ................................ -
Ferrous chloride * ............................... -
Manganese chloride ............................. -
Mercuric chloride * .............................. -
Methylene chloride .............................. -
Chlorine water (wet gaseous chlorine)............... -
Sea water ..................................... +
Fertiliser ...................................... +
Epichlorohydrin................................. -
Heavy gasoline................................. -
White spirit .................................... -
Turpentine .................................... -
Essential oils .................................. +
Linseed oil .................................... +
6. GENERAL CHARACTERISTICS
6.1 Mechanical characteristics
Protection rating:
- IP 55 IK 07 (695 00/02)
- IP 55 (695 01)
6.2 Material characteristics
Box : PP (filled Polypropylene)
Plate : ABS (Acrylonitrile-Butadiene-Styrene)
Cover : PE (Polyethylene)
Mechanism : PC (Polycarbonate))
6.3 Resistance to chemicals
Acetone ...................................... -
Acetic acid (10%) ............................... +
Acetic acid (m 30%) ............................. +
Aminosulphonic acid ............................ -
Boric acid * .................................... +
Hydrobromic acid (47%).......................... -
Hydrochloric acid * .............................. -
Chromic acid .................................. +
Citric acid * .................................... +
Hydrofluoric acid * .............................. -
Formic acid.................................... -
Formic acid.................................... +
Linoleic acid ................................... -
Maleic acid .................................... +
Nitric acid (30%) ................................ -
Nitric acid (50 %) ............................... -
Behaviour
Lubricating oil .................................. +
Machine oi .................................... +
Mineral oil ..................................... +
Paraffin oil .................................... +
Fish oil ....................................... +
Castor oil ..................................... +
Silicon oil ..................................... +
Humus ....................................... +
Aqueous hydrogen sulphide....................... +
Hypochlorite of soda (10%) ....................... +
Fruit juice ..................................... +
Milk .......................................... +
Chlorinated lye ................................. +
Margarine ..................................... +
Fuel oil ....................................... +
Mercury....................................... +
Methyl methacrylate ............................. -
Silver nitrate * .................................. +
Cobalt nitrate * ................................. +
Manganese nitrate * ............................. +
Mercuric nitrate * ............................... +
Nickel nitrate * ................................. +
Lead nitrate * .................................. +
Pétrole, éther de pétrole.......................... -
Petroleum, petroleum ether ....................... +
Silicate (Potassium, Sodium) ...................... +
Sodium
- Sodium acetate * .............................. +
- Sodium bromate * ............................. +
- Sodium chloride * (salt) ......................... +
Perchloric acid (10%) ............................ +
Benzenesulphonic acid .......................... -
Phosphoric acid * ............................... -

Cat. No(s): 695 00/01/02
Technical data sheet: F00339EN/02 Updated: 09/05/2011 Created: 30/04/2007
5/5
Plexo
Automatic switches
CONTENTS
230 V
400 W 400 W 400 VA 400 VA
40 W
Max.
Min. 40 W 40 VA 40 VA
110 V
200 W 200 W 200 VA 200 VA
40 W
Max.
Min. 40 W 40 VA 40 VA
230 V
110 V
1000 W 1000 W 500 VA 500 VA 500 VA 500 VA 100 VA
500 W 500 W250 VA 250 VA 250 VA 250 VA 50 VA
1 max.
<
2 A
1 max.
<
1 A
Power levels 695 02
Power levels 695 01
Power levels 695 00
230 V
300 W 300 W
60 W
Max.
Min. 60 W
110 V
150 W150 W
60 W
Max.
Min. 60 W
1 2 3 4
1 2
1 2
9 10
5 6 7 8
6. GENERAL CHARACTERISTICS (continued)
6.3 Resistance to chemicals
Caustic soda 40 % ............................. +
Monomer styrene ................................ -
Sugar ......................................... +
Trichloroethylene ................................ -
Urine.......................................... +
Wine .......................................... +
*all concentrations in aqueous solution
Key: + resistant - unstable
This information is given as a guide only and can not be construed as an undertaking on the
part of the manufacturer.
Please contact us for specific uses.
6.4 Resistance to ultraviolet radiation
No notable alteration following the 7 day test with 550 W/m2 power
lighting (Colorimetric measurement using lab method).
6.5 Resistance to salt spray: 7 days (168 hrs)
6.6 Electrical characteristics
- Self-extinguishing in accordance with IEC 60695-2-11:
components (or parts) required to secure live parts: 850° C
components (or parts) not required to secure live parts: 650° C
Voltage: 110 - 230 V~
Frequency: 50 Hz
1 - Incandescent lamp
2 - Halogen lamp
3 - Very low voltage halogen lamp with fer-
romagnetic or electronic transformer
4 - Fluorescent tube
5 - Fluocompact lamp
6 - Fluocompact lamp with separate trans-
former
7 - Fan motor
8 - Switch
9 - Very low voltage halogen lamp with
ferromagnetic transformer
10 - Very low voltage halogen lamp with
electronic transformer
7. MAINTENANCE
Clean surface with dry cloth or cloth soaked in soapy water.
Do not use acetone, tar remover or trichlorethylene
Caution: A prior test is required before using specific cleaning
products.
6.7 Climatic characteristics
Storage temperature: - 25° C to + 60° C
Operating temperature: - 5° C to + 35° C