Legrand 363292-01 User Manual

Page 1
Using the Punch & Go Tool
1. ITEMS NEEDED
Legrand Products:
363292-01 - Cat 5 Strip and Fit Tool
AC3400 - Punch & Go Tool
WP3475-WH - Cat 5 Quick Connect RJ45
Keystone Connector
2. INTRODUCTION
A structured wiring foundation is
the most effective way to distribute
information throughout a home. It
supports high-performance technology
through clutter-free cabling hidden
behind the walls. To ensure more
efficient installation, run a single home
run to a central distribution point and
bundle cables for access to multiple
services.
TOOLS & ADDITIONAL SUPPLIES:
• Wire Cutter
• Continuity Tester
• Cat 5 Cable
• RJ45 Jumper Cable
There are several fundamentals to remember when working with Cat 5:
• On-Q products utilize the T568A wiring standard
• Never splice Cat 5 cable
• Always maintain a 12-inch minimum separation between the Cat 5 and any 120 Volt AC cabling. If you must cross and electrical circuit, do so at a 90 degree angle
• Always maintain a minimum bend radius of 1 inch.
• Never exceed the 25 pound pull limit. Doing so may pull the twists out of the wire, which is what gives Cat 5 its immunity from interference. For the same reason, you shouldn’t stand on the wire or use any retention devices that flatten out the wire.
STEP 1
Use the Strip and Fit tool to cut off approximately two inches of the jacket.
STEP 2
Cut the wire separator strands, separate the pairs and untwist them.
STEP 3
Now fan them out in the T568A pattern. White/Green Green White/Orange Blue White/Blue Orange White/Brown Brown
www.legrand.us/onq
Page 2
Using the Punch & Go Tool
3. HOW TO STEP-BY-STEP CONT.
STEP 4
Place the fanned wires into the appropriate color coded terminals and press until fixed.
STEP 5
Insert the connector using the guide rails on either side of the Punch & Go tool and the connector.
STEP 6
Firmly compress the handle of the Punch & Go tool to terminate and cut excess wire.
STEP 7
Place the cap on the back of the connector and press to make sure it is fully seated.
STEP 8
We recommend that you always test for continuity. After placing your completed connector into the wall, plug a short RJ45 jumper cable into the connector. Plug the other end of the jumper cable into the tester.
301 Fulling Mill Road, Suite G
Middletown, PA 17057
(800) 321-2343
©2012 by Legrand. All Rights Reserved.
STEP 9
Place the other tester at the end of the connector cable (at the enclosure) and look for the green light.