Using the Punch & Go Tool
1. ITEMS NEEDED
Legrand Products:
363292-01 - Cat 5 Strip and Fit Tool
AC3400 - Punch & Go Tool
WP3475-WH - Cat 5 Quick Connect RJ45
Keystone Connector
2. INTRODUCTION
A structured wiring foundation is
the most effective way to distribute
information throughout a home. It
supports high-performance technology
through clutter-free cabling hidden
behind the walls. To ensure more
efficient installation, run a single home
run to a central distribution point and
bundle cables for access to multiple
services.
3. HOW TO STEP-BY-STEP
TOOLS & ADDITIONAL SUPPLIES:
• Wire Cutter
• Continuity Tester
• Cat 5 Cable
• RJ45 Jumper Cable
There are several fundamentals to
remember when working with Cat 5:
• On-Q products utilize the T568A wiring
standard
• Never splice Cat 5 cable
• Always maintain a 12-inch minimum
separation between the Cat 5 and any
120 Volt AC cabling. If you must cross
and electrical circuit, do so at a 90
degree angle
• Always maintain a minimum bend
radius of 1 inch.
• Never exceed the 25 pound pull limit.
Doing so may pull the twists out of
the wire, which is what gives Cat 5 its
immunity from interference. For the
same reason, you shouldn’t stand on
the wire or use any retention devices
that flatten out the wire.
STEP 1
Use the Strip and Fit tool to cut off
approximately two inches of the
jacket.
STEP 2
Cut the wire separator strands, separate
the pairs and untwist them.
STEP 3
Now fan them out in the T568A pattern.
White/Green
Green
White/Orange
Blue
White/Blue
Orange
White/Brown
Brown
www.legrand.us/onq

Using the Punch & Go Tool
3. HOW TO STEP-BY-STEP CONT.
STEP 4
Place the fanned wires into the
appropriate color coded terminals and
press until fixed.
STEP 5
Insert the connector using the guide rails
on either side of the Punch & Go tool and
the connector.
STEP 6
Firmly compress the handle of the
Punch & Go tool to terminate and cut
excess wire.
STEP 7
Place the cap on the back of the
connector and press to make sure it is
fully seated.
STEP 8
We recommend that you always test for
continuity. After placing your completed
connector into the wall, plug a short
RJ45 jumper cable into the connector.
Plug the other end of the jumper cable
into the tester.