Getting Started Manual
WA-GSM-E-RevA
3
Welcome
Thank you for purchasing a LeCroy WaveAce product. This Getting Started Manual includes
important safety and installation information for your WaveAce Series oscilloscope, along with
operating procedures to get you started capturing, viewing, and analyzing your waveforms.
This WaveAce Getting Started Manual provides information in the following manner:
Getting to Know WaveAce - First, we acquaint you with your new instrument.This
section contains information on the Hardware (explaining the physical features of your
new instrument), Basic Controls (demonstrating the relationship between some front
panel and screen layout controls), and Probes (explaining Probe connections).
Viewing Waveforms - Covers turning on traces and setting up your display. It also
provides information on using the Auto Setup feature.
Vertical Settings and Channel Controls - Provides step-by-step procedures for
defining you vertical settings and channel controls, such as limiting bandwidth,
adjusting sensitivity and inverting waveforms.
Triggering - Provides step-by-step procedures for the five trigger types - edge, pulse,
video, slope, and alternative.
Analyzing Waveforms - Lists waveform measurements and parameter
measurements. Also provides procedures for using Math functions.
Save and Recall - Provides step-by-step procedures for saving and recalling scope
setups, waveforms, and reference waveforms. Also provides procedures for saving
data, saving and printing pictures, and recalling factory settings.
Utilities - Covers the Utility functions, such as viewing system status.
Reference - This section includes important safety information and specifications for
the WaveAce Series Oscilloscopes.
Support
When your WaveAce Series Oscilloscope is delivered, verify that all items on the packing list
or invoice copy have been shipped to you. Contact your nearest LeCroy customer service
center or national distributor if anything is missing or damaged. If there is something missing or
damaged, and you do not contact us immediately, we cannot be responsible for replacement.If
you have any problems with your product, please refer to the Technical Support contacts at the
end of this Getting Started Manual. You can also refer to additional support materials at
www.lecroy.com, or the Online Help files in your instrument.
Thank You
We truly hope these materials provide increased comprehension when using LeCroy's fine
products.
Sincerely,
David C. Graef
LeCroy Corporation
Vice President and Chief Technology Officer
WaveAce
4
WA-GSM-E-RevA
This symbol is used where caution is required. Refer to the
accompanying information or documents in order to protect
against personal injury or damage to the instrument.
This symbol is used to denote the measurement ground
connection.
This symbol is used to denote a safety ground connection.
This symbol shows that the switch is a Standby (power)
switch. When it is pressed, the oscilloscope’s state toggles
between operating and Standby mode. This switch is not a
disconnect device. The instrument can only be placed in a
complete Power Off state by unplugging the power cord from
the AC supply.
This symbol is used to denote Alternating Current.
CAUTION
The CAUTION sign indicates a potential hazard. It calls
attention to a procedure, practice or condition which, if not
followed, could possibly cause damage to equipment. If a
CAUTION is indicated, do not proceed until its conditions are
fully understood and met.
WARNING
The WARNING sign indicates a potential hazard. It calls
attention to a procedure, practice or condition which, if not
followed, could possibly cause bodily injury or death. If a
WARNING is indicated, do not proceed until its conditions are
Safety Requirements
This section contains information and warnings that must be observed to
keep the instrument operating in a correct and safe condition. You are
required to follow generally accepted safety procedures in addition to the
safety precautions specified in this section.
Safety Symbols
Where the following symbols appear on the instrument’s front or rear
panels, or in this manual, they alert you to important safety considerations.
Getting Started Manual
WA-GSM-E-RevA
5
fully understood and met.
CAT I
Installation (Overvoltage) Category rating per EN 61010-1
safety standard and is applicable for the oscilloscope front
panel measuring terminals. CAT I rated terminals must only
be connected to source circuits in which measures are taken
to limit transient voltages to an appropriately low level.
Operating Environment
The instrument is intended for indoor use and should be operated in a
clean, dry environment with an ambient temperature within the range of +10
°C to 40 °C.
Note: Direct sunlight, radiators, and other heat sources should be taken
into account when assessing the ambient temperature.
WARNING
The oscilloscope must not be operated in explosive, dusty, or wet
atmospheres.
CAUTION
Do not exceed the maximum specified front panel terminal (CH1, CH2, EXT
TRIG) voltage levels. Refer to Specifications for more details.
Installation (Overvoltage) Category II refers to local distribution level, which
is applicable to equipment connected to the mains supply (AC power
source).
Installation (Overvoltage) Category I refers to signal level, which is
applicable to equipment measuring terminals that are connected to source
circuits in which measures are taken to limit transient voltages to an
appropriately low level.
Pollution Degree 2 refers to an operating environment where normally only
dry non-conductive pollution occurs. Occasionally a temporary conductivity
caused by condensation must be expected.
Protection Class 1 refers to a grounded equipment, in which protection
against electric shock is achieved by Basic Insulation and by means of a
connection to the protective ground conductor in the building wiring.
WaveAce
6
WA-GSM-E-RevA
Voltage
Range:
90 to 264 VAC
Frequency
Range:
45 to 440 Hz
PLEASE NOTE THE FOLLOWING:
The design of the instrument has been verified to conform to EN 61010-1
safety standard per the following limits:
Installation (Overvoltage) Categories II (Mains Supply Connector) & I
(Measuring Terminals)
Pollution Degree 2
Protection Class I
Cooling
The instrument relies on forced air cooling with internal fans and ventilation
openings. Care must be taken to avoid restricting the airflow around the
apertures (fan holes) at the sides and rear of the oscilloscope. Ensure
adequate ventilation by leaving the required 10 cm (4 inch) minimum gap
around the sides and rear of the instrument.
CAUTION
Do not block the ventilation holes located on both sides and rear of the
oscilloscope.
CAUTION
Do not allow any foreign matter to enter the oscilloscope through the
ventilation holes, etc.
AC Power Source
100 to 240 Vrms (+/-10%) AC at 50/60/400 Hz; Installation Category: 300V
CAT II
No manual voltage selection is required because the instrument
automatically adapts to line voltage.
Maximum Power Consumption: 50 VA
Note: The instrument automatically adapts itself to the AC line input within
the following ranges:
Getting Started Manual
WA-GSM-E-RevA
7
Power and Ground Connections
The instrument is provided with a grounded cord set containing a molded
three-terminal polarized plug and a standard IEC320 (Type C13) connector
for making line voltage and safety ground connection. The AC inlet ground
terminal is connected directly to the frame of the instrument. For adequate
protection against electrical shock hazard, the power cord plug must be
inserted into a mating AC outlet containing a safety ground contact.
WARNING -Electrical Shock Hazard
Any interruption of the protective conductor inside or outside of the
oscilloscope, or disconnection of the safety ground terminal creates a
hazardous situation.
Intentional interruption is prohibited.
The oscilloscope should be positioned to allow easy access to the socketoutlet. Disconnect the oscilloscope from the AC supply by unplugging the
instrument’s power cord from the AC outlet after the oscilloscope is placed
in Standby state.
CAUTION
The outer shells of the front panel BNC terminals (CH1, CH2, EXT TRIG)
are connected to the instrument’s chassis and therefore to the safety
ground.
Calibration
The recommended calibration interval is one year. Calibration should be
performed by qualified personnel only.
Cleaning
Clean only the exterior of the instrument, using a damp, soft cloth. Do not
use chemicals or abrasive elements. Under no circumstances allow
moisture to penetrate the instrument.
Avoid electrical shock hazard by unplugging the power cord from the AC
outlet before cleaning.
WaveAce
8
WA-GSM-E-RevA
WARNING - Electrical Shock Hazard
No operator serviceable parts inside.
Do not remove covers.
Refer servicing to qualified personnel.
Abnormal Conditions
Operate the instrument only as intended by the manufacturer.
If you suspect the oscilloscope’s protection has been impaired, disconnect
the power cord and secure the instrument against any unintended
operation.
The oscilloscope’s protection is likely to be impaired if, for example, the
instrument shows visible damage or has been subjected to severe transport
stresses.
Proper use of the instrument depends on careful reading of all instructions
and labels.
WARNING
Any use of the oscilloscope in a manner not specified by the manufacturer
may impair the instrument’s safety protection. The instrument and related
accessories should not be directly connected to human subjects or used for
patient monitoring.
Getting Started Manual
WA-GSM-E-RevA
9
Getting to Know WaveAce
Hardware
Front Panel
The WaveAce Series oscilloscopes provide an easy-to-use front panel.
The control buttons are logically grouped. The following provides an
explanation of the front panel buttons and knobs.
1. Power button
2. USB port
3. Menu On/Off, Menu Option buttons and Print button
Numbered labels on this graphic correspond with descriptions in the table.
1. Pass/Fail Output
2. RS-232 Connector
3. Back USB Connector
Getting Started Manual
WA-GSM-E-RevA
11
Side Panel
The WaveAce side panel is located on the left side (facing the front of the
instrument). The Power input is located on the side panel as follows:
WaveAce
12
WA-GSM-E-RevA
Basic Controls
Powering Up Your WaveAce
1. Power On the oscilloscope by pressing the power button on the top
left (facing) the instrument.
2. The LeCroy Splash screen is shown. Press any key to continue (or,
after a brief period the grid display is shown).
3. The Grid Display is shown.
Getting Started Manual
WA-GSM-E-RevA
13
Front Panel Controls
INTENSITY/ADJUST KNOB
Intensity/Adjust knob - You can use the Adjust knob with many
functions, such as adjusting the holdoff time, moving cursors, setting
the pulse width, setting the video lineage adjusting the upper and
lower frequency limits, adjusting X and Y masks when using the
Pass/Fail function, etc. You can also turn the Adjust knob to adjust
the storage position of setups, waveforms, pictures when
saving/recalling and to select menu options.
WaveAce
14
WA-GSM-E-RevA
MENU CONTROL BUTTONS
MENU ON/OFF - Press to toggle the last-displayed menu On/Off.
Menu Option buttons (1-5) - Press to choose menu options. Press
a menu option button adjacent to your selection.
Print - Press to save the current waveform to an attached USB
memory device or print a picture (screen shot) to a USB-connected
printer. You can set up the save/print options using the Save/Recall
→ Picture settings. For more information, refer to Saving and
Printing Waveform Pictures.
Getting Started Manual
WA-GSM-E-RevA
15
MENU FUNCTION BUTTONS
CURSORS - Press to turn on the cursors and display the Cursor
menu. You can use the Cursor menu to set the Cursor Mode (Auto,
Off, Manual, Track). When Cursors are on (CURSORS button is lit),
turn the Adjust knob to position the cursors.
ACQUIRE - Press to display Acquire menu. You can use the
Acquire menu to set the acquisition Sampling Mode (Sampling,
Peak Detect, Average). For more information on sampling modes,
refer to Acquisition Sampling Modes.
SAVE/RECALL - Press to display the Save/Recall menu. You can
use the Save/Recall menu to save and recall up to 20 scope setups
or waveforms in internal memory (up to 20 waveforms) or on a USB
memory device (limited by memory capacity of USB device). You can
also use it to recall the default factory settings, to save waveform
data as a comma-delimited file (.CSV), and to save or print the
displayed waveform image.
MEASURE - Press to display a menu of measurement parameters.
The Display Type must be set to YT mode. For more information on
measurement parameters, refer to Parameter Measurements.
DISPLAY - Press to open the Display menu. You can use the
Display menu to set grid and waveform display styles, and
persistence.
UTILITY - Press to open the Utility menu. You can use the Utility
menu to configure WaveAce features, such as sound, language,
counter, etc. You can also view system status and update software.
WaveAce
16
WA-GSM-E-RevA
GENERAL CONTROL BUTTONS
HELP - Displays context-sensitive online help. Press Help than
another front panel button and information about that button will be
displayed.
DEFAULT SETUP - Press to reset the oscilloscope's settings to the
default factory configuration. For a list of default settings, see
Recalling Factory Settings.
AUTO - Press to have the oscilloscope automatically identify the type
of waveform and adjust the controls to produce a usable display of
the input signal. When you press the AUTO front panel button, the
Auto Set menu opens. You can use this menu to display multiplecycle signals, a single-cycle signal, the rising edge, the falling edge
or recall the previous setup.
RUN CONTROL BUTTONS
SINGLE - Press to acquire a single waveform. Each time you press
the SINGLE button, the oscilloscope acquires another waveform.
When the oscilloscope detects a trigger it completes the acquisition
and stops.
RUN/STOP - Press when you want the oscilloscope to acquire
waveforms continuously. Press RUN/STOP again to stop the
acquisition,
Getting Started Manual
WA-GSM-E-RevA
17
VERTICAL CONTROLS
Volts/Div knobs (CH1/CH2)- Turn to adjust the volts/division setting
(vertical gain) of the corresponding channel (CH1 or CH2). Press the
knob to toggle between fine (variable) and coarse (fixed)
adjustments.
Channel buttons (CH1/CH2) - Press a channel button (CH1 or CH2)
to turn that channel ON or OFF and open the Channel menu for that
channel. You can use the Channel menu to set up a channel. When
the channel is ON, the channel button is lit.
Vertical Position knobs (CH1/CH2) - Turn to adjust the vertical
position of the corresponding channel (CH1 or CH2). Press to set the
vertical position to zero.
REF - Press to display the Ref Wave menu. You can use this menu
to save and recall two reference waveforms (REFA and REFB) in
internal memory.
MATH - Press to display the Math menu. You can use the Math
menu to use the oscilloscopes Math functions.
WaveAce
18
WA-GSM-E-RevA
HORIZONTAL CONTROLS
Horizontal Position knob - Turn to adjust the horizontal position of
all channels and math waveforms (the position of the trigger relative
to the center of the screen). The resolution of this control varies
depending on the timebase setting. Press to set the horizontal
position to zero.
HORI MENU - Press to display the Horizontal menu. You can use
the Horizontal menu to display the waveform and to zoom a
segment of a waveform.
Time/Div knob - Turn to change the horizontal time scale to magnify
or compress the waveform. When Window Zone is enables, it
changes the width of the Window Zone by changing the window
timebase. WhenTime/Div control is set to 100 ms/div or slower and
the trigger mode is set to Auto, the oscilloscope enters the scan
acquisition mode. In this mode, the waveform display updates from
left to right. There is no trigger or horizontal position control of
waveforms during scan mode.