connections for printers,
memory sticks and PC
remote control
A good oscilloscope should
simplify how you work and
shorten the time it takes to
nd and debug problems.
The WaveAce™ combines
long memory, a color display,
extensive measurement
capabilities, advanced
triggering and excellent
connectivity to improve
troubleshooting and shorten
debug time. With bandwidths
from 40 MHz to 200 MHz,
sample rates up to 2 GS/s
and waveform memory
up to 10 kpts/Ch (20 kpts
interleaved) the WaveAce
exceeds all expectations of a
small affordable oscilloscope.
Long Capture and Zoom
Small, portable oscilloscopes often
suffer from short capture time due
to the small waveform memory. The
WaveAce is available in 4 kpts/Ch
and 10 kpts/Ch congurations which
is up two to three times more than
competitive products. More memory
results in longer capture times showing
more waveform detail with each trigger.
Activate the built-in zoom function
to take a closer look at the details.
Digital Filter
Digital ltering is available on each
channel of the WaveAce. The Low-Pass,
High-Pass, Band-Pass and Band-Stop
lters allow you to isolate only the
frequencies you want to see.
Trigger
Edge triggering is not always the best
choice for every signal. Beyond the
basic edge trigger is a set of trigger
capabilities which include Pulse Width,
Video and Slope (Rise Time) triggers.
2
Automatic Measurements
With 32 standard automatic measure-
ments the WaveAce simplies
how you work. Display up to ve
measurements without crowding
the waveform display or show all
32 at once with the measurement
dashboard. A wide range of advanced
timing parameters provide insight
to the relationship between two
different signals.
Waveform Math
The WaveAce provides ve math
functions including Add, Subtract,
Multiply, Divide and FFT. The FFT
capability includes the choices of
four windows and two different
vertical scales.
Connectivity
The WaveAce provides a USB host port
on the front panel for saving screen
images, waveforms and setups to a
memory stick. A rear panel USB device
port allows for connection to a PC or
printer. Connecting and communicating
with a PC is simplied with EasyScope
software providing full access to the
oscilloscope’s display, measurements,
waveform data and front panel controls.
Large Internal Storage
Saving and recalling waveforms and
setups from internal memory can save
a lot of time during test and debug. The
WaveAce can save up to 20 waveforms,
20 setups and two reference waveforms
to the internal memory.
Pass/Fail Test
With built-in Pass/Fail Mask testing
the WaveAce can quickly identify
problems and let you know when
they occur. A history of the P/F results
can be displayed on the screen.
Waveform Sequence Recorder
Capture and replay a sequence of
up to 2500 waveforms to isolate
that runt or glitch which is causing
problems in your system.
Acquisition Modes
Different applications call for different
acquisitions modes. The WaveAce
offers Real Time, Equivalent Time, Peak
Detect and Averaging modes to ensure
that any waveform can be captured
and displayed.
3
SMART, SIMPLE, EFFICIENT
1. Fast Power Up
The WaveAce turns on and is ready for
use in under 10 seconds.
2. Display
All WaveAce models have a
5.7" color display.
4
9
3. Connectivity
Saving waveforms, screenshots and
setups is easy with the front panel USB
port for use with a memory stick.
4. Portability
The small compact form factor is
lightweight and only 5" deep.
5. Communication
Rear panel USB and RS-232 ports
enable direct remote control from
a PC. The USB port also allows for
connecting to a printer.
5
2
10
1
3
6. Intensity
Waveform intensity can be quickly
adjusted by rotating this knob, a
meter on the display will appear
and show the current setting.
7. Individual Vertical Controls
Quickly change the vertical scale
of either channel.
4
8. Push Knobs
All WaveAce knobs can be pushed
6
11
12
13
for additional capabilities. Push the
V/div knobs to toggle between xed
and variable gain. Push the T/div knob
to enter zoom mode and push the
position knobs to center the waveform
on screen.
9. Local Language User
7
Interface
The intuitive user interface is available
in several different languages.
10. Front Panel Print Button
Saving or Printing screenshots requires
8
only a single button press.
11. Backlit Menu Buttons
When using certain features like
Cursors or Measurements the button
remains lit for easy menu navigation.
12. Context Sensitive Help
Press any button or turn any knob while
in help mode and a pop-up
window displays the functionality
of that control.
13. Auto Setup
Quickly congures the vertical,
horizontal and trigger settings for
the WaveAce. Choose to view the
waveform as multi-cycle, single-
cycle, rising or falling edge.
5
WAVEACE 100 SPECIFICATIONS
WaveAce WaveAce
101 102
Bandwidth 40 MHz 60 MHz
Rise Time 8.8 ns 5.8 ns
Input Channels 2 2
Display 5.7” Color, 320 x 240 Resolution
Sampling Rate (Single Shot) 500 MS/s (interleaved),
250 MS/s (all channels)
Sampling Rate (Equivalent Time) 50 GS/s
Peak Detect Period 10 ns
Memory Length 4 kpts/Ch
Maximum Memory 4 kpts
Vertical Resolution 8-bits
Vertical Sensitivity 2 mV/div–5 V/div
Bandwidth Limiting Filter 20 MHz
Maximum Input Voltage 400 Vpk, 300 V
Input Coupling GND, DC 1 MΩ, AC 1 MΩ
Input Impedance 1 MΩ || 13 pF
Probes 10:1, 1:1 Switchable Passive Probe (one per channel)
Timebase Range 10 ns/div–50 s/div 5 ns/div–50 s/div
Measure Amplitude, Average, Base, Burst Width, Cyclic RMS, + Duty Cycle, - Duty Cycle, Fall Time, Frequency,
Math Add, Subtract, Multiply, Divide, FFT (up to 1 kpts with Rectangular, Von Hann, Hamming or
Waveform Sequence Recorder Record and playback a sequence of up to 2500 waveforms
Max, Mean, Min, Overshoot, Peak-Peak, Period, Phase, Rise Time, RMS, Top, + Width, - Width.
Plus 8 advanced parameters for edge to edge timing measurements
Blackman windows)
Input/Output Interfaces
USB USB host port for flash drives, USB device port for connecting to PC and printers
RS-232 RS-232 port for connection to PC and EasyScope software (2 Channel models only)
LAN LAN port for connection to PC and EasyScope software (4 Channel models only)
Physical
2 Ch Models
Dimensions (HWD) 154 mm x 305 mm x 133 mm; 6" x 12" x 5.25" (height excludes feet)
Weight 2.3 kg; 5 lbs.
4 Ch Models
Dimensions (HWD) 159 mm x 336 mm x 133 mm; 6.3" x 13.2" x 5.25" (height excludes feet)
Weight 3 kg; 6.6 lbs.
7
ORDERING INFORMATION
Ordering Information
Product Description Product Code
40 MHz, 250 MS/s, 2 Ch, 4 kpts/Ch with 5.7" WaveAce 101
Color Display. 500 MS/s Iinterleaved, 1 M
60 MHz, 250 MS/s, 2 Ch, 4 kpts/Ch with 5.7" WaveAce 102
Color Display. 500 MS/s Interleaved, 1 M
60 MHz, 1 GS/s, 2 Ch, 9 kpts/Ch with 5.7" WaveAce 202
Color Display. 18 kpts Interleaved. 1 M
60 MHz, 1 GS/s, 4 Ch, 10 kpts/Ch with 5.7" WaveAce 204
Color Display. 20 kpts Interleaved. 1 M
100 MHz, 1 GS/s, 2 Ch, 9 kpts/Ch with 5.7" WaveAce 212
Color Display. 18 kpts Interleaved. 1 M
100 MHz, 1 GS/s, 4 Ch, 10 kpts/Ch with 5.7" WaveAce 214
Color Display. 20 kpts Interleaved. 1 M
200 MHz, 1 GS/s, 2 Ch, 9 kpts/Ch with 5.7" WaveAce 222
Color Display. 18 kpts, 2 GS/s Interleaved.
50/1 M
Ω Input
200 MHz, 1 GS/s, 4 Ch, 10 kpts/Ch with 5.7" WaveAce 224
Color Display. 20 kpts, 2 GS/s Interleaved.
50/1 M
Ω Input
Ω Input
Ω Input
Ω Input
Ω Input
Ω Input
Ω Input
Product Description Product Code
Included with Standard Conguration
One Passive Probe per Channel
Multi-language User-interface and Help (English, French,
German, Italian, Japanese, Korean, Russian, Simplied
Chinese, Spanish, Traditional Chinese)
EasyScope PC Software with USB Cable
Getting Started Manual
Protective Front Cover (4 channel models only)
Calibration and Performance Certicate
3-year Warranty
Accessories
Soft Carrying Case for WaveAce Oscilloscopes WA-SOFTCASE
Customer Service
Teledyne LeCroy oscilloscopes and probes are designed, built, and
tested to ensure high reliability. In the unlikely event you experience
difculties, our digital oscilloscopes are fully warranted for three years
and our probes are warranted for one year.