Leader LT4670-SER01, LT4670-SER02, LT4670-SER03, LT4670-SER11, LT4670-SER21 Users Guide

...
Page 1
LT4670
SYNC GENERATOR
LT4670-SER01 GNSS LT4670-SER02 SDI LT4670-SER03 PTP LT4670-SER11 POWER UNIT LT4670-SER21 4K 3G-Quad Link
Instruction Manual
Thank you for your purchase. Please read this instruction manual and the included “GENERAL SAFETY SUMMARY” thoroughly, and use the product safely.
Page 2
TABLE OF CONTENTS
GENERAL SAFETY SUMMARY .................................................................................. I
1 INTRODUCTION ............................................................................................ 1
1.1 User Registration ................................................................................................................ 1
1.2 Scope of Warranty .............................................................................................................. 1
1.3 Trademark Acknowledgments .............................................................................................. 1
1.4 Operating Precautions ......................................................................................................... 2
1.4.1 Power Supply Voltage .................................................................................................. 2
1.4.2 Maximum Allowable Input Voltage ................................................................................. 2
1.4.3 Mechanical Shock ........................................................................................................ 2
1.4.4 Electrostatic Damage ................................................................................................... 2
1.4.5 Warming Up................................................................................................................ 2
2 PRODUCT CONFIGURATION ............................................................................ 3
2.1 Main Unit .......................................................................................................................... 3
2.2 Hardware Options .............................................................................................................. 3
2.3 Software Options ............................................................................................................... 4
3 SPECIFICATIONS ........................................................................................... 5
3.1 General ............................................................................................................................. 5
3.2 Features ............................................................................................................................ 5
3.2.1 LT4670 ....................................................................................................................... 5
3.2.2 LT4670-SER01 (GNSS) ................................................................................................. 7
3.2.3 LT4670-SER02 (SDI) .................................................................................................... 7
3.2.4 LT4670-SER03 (PTP) ................................................................................................... 8
3.2.5 LT4670-SER11 (POWER UNIT) ...................................................................................... 9
3.2.6 LT4670-SER21 (4K 3G-Quad Link) ................................................................................. 9
3.3 Standards ........................................................................................................................ 11
3.3.1 LT4670 ..................................................................................................................... 11
3.3.2 LT4670-SER01 (GNSS) ............................................................................................... 19
3.3.3 LT4670-SER02 (SDI) .................................................................................................. 20
3.3.4 LT4670-SER03 (PTP) ................................................................................................. 25
3.3.5 LT4670-SER11 (POWER UNIT) .................................................................................... 26
3.3.6 LT4670-SER21 (4K 3G-Quad Link) ............................................................................... 27
4 PANEL DESCRIPTION .................................................................................... 31
4.1 Front Panel ...................................................................................................................... 31
4.2 Rear Panel ....................................................................................................................... 34
5 PREPARATIONS ............................................................................................ 37
5.1 Turning the Power On ....................................................................................................... 37
Page 3
5.1.1 Turning the Instrument On and Off .............................................................................. 37
5.1.2 Mounting the AC Cord Clamp ...................................................................................... 38
5.1.3 Adding the Power Supply Unit (SER11) ........................................................................ 39
5.2 Rack Mounting ................................................................................................................. 41
6 BASIC OPERATION ....................................................................................... 42
6.1 Operation Basics .............................................................................................................. 42
6.1.1 Connecting a USB Memory Device ............................................................................... 42
6.1.2 Enabling the Key Lock ................................................................................................ 42
6.1.3 Menu Operations ....................................................................................................... 43
6.2 Signal Input (Genlock Operation) ....................................................................................... 46
6.2.1 Internal Mode ........................................................................................................... 46
6.2.2 Genlock Mode ........................................................................................................... 47
6.2.3 CW Mode .................................................................................................................. 49
6.2.4 GNSS mode (SER01) .................................................................................................. 51
6.2.5 PTP mode (SER03) .................................................................................................... 53
6.3 SDI Signal Output ............................................................................................................ 56
6.3.1 Analog Black Signal Output ......................................................................................... 56
6.3.2 Audio Signal Output ................................................................................................... 56
6.3.3 CW/1PPS Signal Output .............................................................................................. 56
6.3.4 SDI Signal Output (SER02) ......................................................................................... 56
6.3.5 PTP Signal Output (SER03) ......................................................................................... 57
6.4 LTC Signal I/O and Remote Control .................................................................................... 59
6.5 Alarm Display .................................................................................................................. 61
6.6 L-SYNC ........................................................................................................................... 62
7 REFERENCE CONFIG MENU ........................................................................... 64
7.1 Selecting the Reference Signal ........................................................................................... 64
7.2 Selecting the Genlock Format ............................................................................................ 65
7.3 Setting the Genlock Timing ................................................................................................ 66
7.4 Selecting the Satellite (SER01) ........................................................................................... 66
7.5 Setting the Recovery Operation .......................................................................................... 67
7.5.1 Selecting the Recovery Mode ...................................................................................... 67
7.5.2 Selecting the Relock Speed (Auto) ............................................................................... 67
7.5.3 Selecting the Relock Speed (Manual)............................................................................ 68
7.5.4 Power-on Settings ..................................................................................................... 68
7.6 Setting the Relock ............................................................................................................ 68
7.7 Selecting the Time Source ................................................................................................. 69
7.8 Loading the Date and Time ............................................................................................... 70
8 BLACK CONFIG MENU ................................................................................... 71
8.1 Selecting the Black Format ................................................................................................ 71
8.2 Configuring Timing Data ................................................................................................... 72
8.2.1 Adjusting the Timing (Frame) ..................................................................................... 72
8.2.2 Adjusting the Timing (Line) ........................................................................................ 72
8.2.3 Adjusting the Timing (Dot) ......................................................................................... 73
Page 4
8.3 Setting the Time Code ...................................................................................................... 73
8.3.1 Turning Time Code Insertion On and Off....................................................................... 73
8.3.2 Setting Dropped Frames ............................................................................................. 74
8.3.3 Setting the Time Code Superimposition Line ................................................................. 74
8.4 Setting the Black Output ................................................................................................... 75
8.4.1 Turning the Black Output On and Off ............................................................................ 75
8.4.2 Turning BMCA Linkage On and Off (SER03) .................................................................. 75
8.5 Settings Shared by Black Outputs ....................................................................................... 76
9 AUDIO CONFIG MENU ................................................................................... 77
9.1 Setting the AES/EBU Output .............................................................................................. 77
9.1.1 Selecting the Frequency ............................................................................................. 77
9.1.2 Setting the Level ....................................................................................................... 77
9.1.3 Setting Clicks ............................................................................................................ 78
9.1.4 Settings Shared by Channels ....................................................................................... 78
9.1.5 Selecting the Resolution ............................................................................................. 78
9.1.6 Selecting the Pre-emphasis Mode ................................................................................ 79
9.1.7 Turning Time Code Insertion On and Off....................................................................... 79
9.1.8 Adjusting the Timing .................................................................................................. 79
9.1.9 Turning Lip Sync Interlock On and Off (SER02) ............................................................. 80
9.2 Setting the Silence Output ................................................................................................. 80
9.2.1 Settings Shared with the AES/EBU Output .................................................................... 80
9.2.2 Selecting the Resolution ............................................................................................. 81
9.2.3 Adjusting the Timing .................................................................................................. 81
9.3 Setting the Word-clock Output ........................................................................................... 82
9.3.1 Adjusting the Timing .................................................................................................. 82
10 LTC CONFIG MENU ....................................................................................... 83
10.1 Turning the LTC Output On and Off ..................................................................................... 83
10.2 Selecting the LTC Format .................................................................................................. 83
10.3 Adjusting the Timing (Frame) ............................................................................................ 84
10.4 Adjusting the Timing (Bit) ................................................................................................. 84
10.5 Adjusting the Offset .......................................................................................................... 84
10.6 Setting Dropped Frames.................................................................................................... 85
10.7 Settings Shared by LTC Outputs ......................................................................................... 85
11 CW/1PPS CONFIG MENU ............................................................................... 86
11.1 Switching the Output Signal............................................................................................... 86
12 SDI CONFIG MENU (SER02) .......................................................................... 87
12.1 Selecting the Frequency Group .......................................................................................... 87
12.2 Setting the SDI Format ..................................................................................................... 88
12.2.1 Selecting the System ................................................................................................. 88
12.2.2 Selecting the Color System ......................................................................................... 89
12.2.3 Selecting the Frame Frequency ................................................................................... 89
Page 5
12.3 Configuring Timing Data ................................................................................................... 90
12.3.1 Selecting the Timing Reference ................................................................................... 90
12.3.2 Adjusting the Timing (Line) ........................................................................................ 90
12.3.3 Adjusting the Timing (Dot) ......................................................................................... 91
12.4 Configuring Fixed Patterns ................................................................................................. 91
12.5 Configuring User Patterns .................................................................................................. 94
12.5.1 Displaying a User Pattern ........................................................................................... 94
12.5.2 Selecting and Transferring a User Pattern ..................................................................... 98
12.5.3 Clearing a User Pattern .............................................................................................. 99
12.5.4 Copying a User Pattern from a USB Memory Device to the Instrument ........................... 100
12.5.5 Copying a User Pattern from the Instrument to a USB Memory Device ........................... 102
12.6 Turning YCbCr/GBR On and Off ........................................................................................ 104
12.7 Turning Safety Area Markers On and Off ........................................................................... 104
12.8 Configuring the Pattern Scroll Feature ............................................................................... 105
12.8.1 Turning Scrolling On and Off ..................................................................................... 105
12.8.2 Setting the Scroll Speed (Vertical) ............................................................................. 105
12.8.3 Setting the Scroll Speed (Horizontal).......................................................................... 106
12.9 Setting the Pattern Change .............................................................................................. 106
12.9.1 Turning Pattern Change On and Off ........................................................................... 106
12.9.2 Setting the Change Interval ...................................................................................... 107
12.10 Setting ID Characters ..................................................................................................... 107
12.10.1 Turning ID Characters On and Off .............................................................................. 108
12.10.2 Recalling ID Characters ............................................................................................ 108
12.10.3 Creating ID Characters ............................................................................................. 108
12.10.4 Setting the Position of ID Characters (Vertical) ............................................................ 109
12.10.5 Setting the Position of ID Characters (Horizontal) ........................................................ 109
12.10.6 Selecting the Size of ID Characters ............................................................................ 110
12.10.7 Selecting the Level of ID Characters........................................................................... 110
12.10.8 Turning ID Character Blinking On and Off ................................................................... 110
12.10.9 Setting the ID Character On-Time .............................................................................. 111
12.10.10 Setting the ID Character Off-Time.............................................................................. 111
12.10.11 Turning ID Character Scrolling On and Off .................................................................. 111
12.10.12 Setting ID Character Scroll Speed .............................................................................. 112
12.10.13 Saving ID Characters ............................................................................................... 112
12.10.14 Copying ID Characters from a USB Memory Device to the Instrument............................ 113
12.10.15 Copying ID Characters from the Instrument to a USB Memory Device............................ 114
12.10.16 Clearing ID Characters ............................................................................................. 114
12.11 Setting Logos ................................................................................................................. 115
12.11.1 Displaying a Logo .................................................................................................... 115
12.11.2 Turning the Logo On and Off ..................................................................................... 117
12.11.3 Selecting a Logo ...................................................................................................... 117
12.11.4 Setting the Logo Position (Vertical) ............................................................................ 117
12.11.5 Setting the Logo Position (Horizontal) ........................................................................ 118
12.11.6 Turning the Logo Transparency On and Off ................................................................. 118
12.11.7 Setting the Logo Transparency Level .......................................................................... 118
12.11.8 Copying Logos from a USB Memory Device to the Instrument ....................................... 119
12.11.9 Copying a Logo from the Instrument to a USB Memory Device ..................................... 120
Page 6
12.11.10 Clearing a Logo ....................................................................................................... 121
12.12 Setting the Moving Box ................................................................................................... 122
12.12.1 Turning the Moving Box On and Off ........................................................................... 122
12.12.2 Selecting the Moving Box Color ................................................................................. 123
12.12.3 Selecting the Moving Box Speed (Vertical) .................................................................. 123
12.12.4 Selecting the Moving Box Speed (Horizontal) .............................................................. 123
12.12.5 Selecting the Moving Box Height ............................................................................... 124
12.12.6 Selecting the Moving Box Width ................................................................................ 124
12.13 Setting a Circle .............................................................................................................. 125
12.13.1 Turning the Circle On and Off .................................................................................... 125
12.13.2 Selecting the Circle Level .......................................................................................... 126
12.13.3 Selecting the Circle Size ........................................................................................... 126
12.13.4 Turning Circle Blinking On and Off ............................................................................. 126
12.13.5 Setting the Circle Blinking On-Time ............................................................................ 127
12.13.6 Setting the Circle Blinking Off-Time ............................................................................ 127
12.14 Setting the Time Code .................................................................................................... 128
12.14.1 Turning the Time Code On and Off ............................................................................. 128
12.14.2 Setting the Time Code Position (Vertical) .................................................................... 129
12.14.3 Setting the Time Code Position (Horizontal) ................................................................ 129
12.14.4 Selecting the Time Code Size .................................................................................... 129
12.14.5 Selecting the Time Code Level .................................................................................. 130
12.15 Turning Lip Sync On and Off ............................................................................................ 130
12.16 Configuring Embedded Audio ........................................................................................... 132
12.16.1 Turning the Audio On and Off .................................................................................... 133
12.16.2 Selecting the Resolution ........................................................................................... 133
12.16.3 Selecting the Pre-emphasis Mode .............................................................................. 133
12.16.4 Selecting the Frequency ........................................................................................... 134
12.16.5 Setting the Level ..................................................................................................... 134
12.16.6 Setting Clicks .......................................................................................................... 134
12.16.7 Settings Shared by Channels ..................................................................................... 135
12.16.8 Settings Shared by Groups ....................................................................................... 135
12.17 Setting Ancillary Data ..................................................................................................... 136
12.17.1 Turning the LTC Signals On and Off ............................................................................ 136
12.17.2 Turning the VITC Signals On and Off .......................................................................... 136
12.17.3 Setting Dropped Frames ........................................................................................... 137
12.18 Setting the SDI Output ................................................................................................... 137
12.18.1 Turning the SDI Output On and Off ............................................................................ 137
12.18.2 Turning BMCA Linkage On and Off (SER03) ................................................................ 138
12.19 Settings Shared by SDI Outputs ....................................................................................... 138
13 PTP CONFIG MENU (SER03) ........................................................................ 139
13.1 PTP Leader and PTP Follower ........................................................................................... 139
13.2 Setting the PTP Leader ................................................................................................... 139
13.2.1 Selecting the Mode .................................................................................................. 139
13.2.2 Configuring BMCA .................................................................................................... 140
13.2.3 Recovering Priority 1 ................................................................................................ 140
13.2.4 Selecting the Profile ................................................................................................. 140
Page 7
13.2.5 Profile Default Settings ............................................................................................. 141
13.2.6 Setting the Domain .................................................................................................. 141
13.2.7 Selecting the Communication Mode ........................................................................... 141
13.2.8 Setting the Announce Message Transmission Interval ................................................... 142
13.2.9 Setting the Sync Message Transmission Interval .......................................................... 142
13.2.10 Setting the Announce Timeout .................................................................................. 143
13.2.11 Setting Priority 1 ..................................................................................................... 143
13.2.12 Setting Priority 2 ..................................................................................................... 143
13.2.13 Selecting the Step ................................................................................................... 144
13.2.14 Selecting the Default Frame ...................................................................................... 144
13.2.15 Setting the Dropped Frame Flag ................................................................................ 144
13.2.16 Setting the Color Frame ID ....................................................................................... 145
13.2.17 Selecting the Propagation Time Measurement Method.................................................. 145
13.3 Setting the PTP Follower ................................................................................................. 146
13.3.1 Selecting the Mode .................................................................................................. 146
13.3.2 Selecting the Profile ................................................................................................. 146
13.3.3 Profile Default Settings ............................................................................................. 146
13.3.4 Setting the Domain .................................................................................................. 147
13.3.5 Setting the Communication Mode .............................................................................. 147
13.3.6 Selecting the Desired Announce Message Transmission Interval .................................... 148
13.3.7 Selecting the Announce Message Reception Interval .................................................... 148
13.3.8 Selecting the Desired Sync Message Transmission Interval ........................................... 149
13.3.9 Selecting the Sync Message Reception Interval ........................................................... 149
13.3.10 Selecting the Delay Message Transmission Interval ...................................................... 150
13.3.11 Selecting the Desired Delay Message Transmission Interval .......................................... 150
13.3.12 Selecting the Delay Message Reception Interval .......................................................... 151
13.3.13 Setting the Announce Timeout .................................................................................. 151
13.3.14 Selecting the Propagation Time Measurement Method.................................................. 152
13.3.15 Setting the IP Address.............................................................................................. 152
13.3.16 Setting the Asymmetric Delay ................................................................................... 152
14 SYSTEM CONFIG MENU ............................................................................... 153
14.1 Setting the Backlight ....................................................................................................... 153
14.2 Configuring Presets ........................................................................................................ 153
14.2.1 Recalling Presets ..................................................................................................... 154
14.2.2 Storing Presets ........................................................................................................ 154
14.2.3 Adding a Comment .................................................................................................. 155
14.2.4 Power-on Settings ................................................................................................... 155
14.2.5 Copying Presets from a USB Memory Device to the Instrument ..................................... 156
14.2.6 Copying Presets from the Instrument to a USB Memory Device ..................................... 157
14.2.7 Clearing Presets ...................................................................................................... 158
14.3 Setting the Network........................................................................................................ 158
14.3.1 Setting the Network ................................................................................................. 158
14.3.2 Setting the IP Address.............................................................................................. 159
14.3.3 Setting the Subnet Mask ........................................................................................... 159
14.3.4 Setting the Default Gateway ..................................................................................... 159
14.3.5 Configuring SNMP .................................................................................................... 160
Page 8
14.3.6 Displaying the SNMP Engine ID ................................................................................. 160
14.3.7 Setting the SNMP Trap Transmission Destinations ........................................................ 160
14.3.8 Setting the IP Addresses of the SNMP Trap Transmission Destinations ............................ 161
14.3.9 Copying MIB Files from the Instrument to a USB Memory Device .................................. 161
14.3.10 Setting the SNMP Community Names ......................................................................... 162
14.3.11 Restarting SNMP ...................................................................................................... 162
14.3.12 Configuring HTTP .................................................................................................... 163
14.3.13 Configuring the Web Browser .................................................................................... 163
14.3.14 Configuring NTP ...................................................................................................... 163
14.3.15 Setting the NTP Server ............................................................................................. 164
14.4 Setting the Time ............................................................................................................ 165
14.4.1 Setting the Date and Time ........................................................................................ 165
14.4.2 Selecting the Time Zone ........................................................................................... 165
14.4.3 Turning Jam Sync On and Off .................................................................................... 166
14.4.4 Setting the Jam Sync Time ....................................................................................... 166
14.4.5 Turning the Daylight Saving Time On and Off (SER01) ................................................. 166
14.4.6 Setting the Daylight Saving Time Start Date (SER01)................................................... 167
14.4.7 Setting the Daylight Saving Time Offset (SER01) ......................................................... 167
14.4.8 Setting the Daylight Saving Time End Date (SER01) .................................................... 167
14.4.9 Setting the Leap Second (SER01) .............................................................................. 168
14.4.10 Setting L-SYNC ........................................................................................................ 168
14.5 Setting the GNSS (SER01) ............................................................................................... 169
14.5.1 Setting the Power Supply ......................................................................................... 169
14.5.2 Setting the Cable Delay ............................................................................................ 169
14.6 Configuring the PTP Settings (SER03) ............................................................................... 170
14.6.1 Setting the IP Address.............................................................................................. 170
14.6.2 Setting the Subnet Mask ........................................................................................... 170
14.6.3 Setting the Gateway ................................................................................................ 171
14.6.4 Configuring SFP ....................................................................................................... 171
14.6.5 Setting Port Mirroring ............................................................................................... 171
14.7 Setting the Alarm ........................................................................................................... 172
14.7.1 Selecting the Polarity ............................................................................................... 172
14.7.2 Turning the Alarm Output On and Off ......................................................................... 173
14.8 Configuring the Log ........................................................................................................ 174
14.8.1 Viewing the Log ...................................................................................................... 174
14.8.2 Copying the Log from the Instrument to a USB Memory Device .................................... 174
14.8.3 Clearing the Log ...................................................................................................... 175
14.9 Initialization ................................................................................................................... 175
14.9.1 Initializing the Settings ............................................................................................. 176
14.9.2 Factory Default Initialization ...................................................................................... 176
14.9.3 Selecting the Initial Value for the Format .................................................................... 176
14.10 Viewing and Adding Software Options ............................................................................... 177
14.10.1 Viewing Software Options ......................................................................................... 177
14.10.2 Adding Software Options .......................................................................................... 177
14.11 Configuring USB ............................................................................................................. 178
14.12 Turning the Fans On and Off ............................................................................................ 178
14.13 Copying the System Settings ........................................................................................... 179
Page 9
14.13.1 Copying System Settings from a USB Memory Device to the Instrument ........................ 179
14.13.2 Copying System Settings from the Instrument to a USB Memory Device ........................ 180
15 STATUS MENU ........................................................................................... 181
15.1 ALARM Menu ................................................................................................................. 181
15.2 INFORMATION Menu....................................................................................................... 182
15.3 CONFIG Menu ................................................................................................................ 184
15.3.1 REFERENCE Menu .................................................................................................... 184
15.3.2 BLACK Menu ........................................................................................................... 185
15.3.3 GNSS Menu (SER01) ................................................................................................ 185
15.3.4 SDI Menu (SER02) ................................................................................................... 186
15.3.5 PTP Menu (SER03) .................................................................................................. 186
15.3.6 SYSTEM Menu ......................................................................................................... 187
15.4 LOG Menu ..................................................................................................................... 188
15.4.1 Viewing the Log ...................................................................................................... 188
15.4.2 Clearing the Log ...................................................................................................... 188
16 SNMP........................................................................................................ 189
16.1 SNMP Versions ............................................................................................................... 189
16.2 SMI Definitions ............................................................................................................... 189
16.3 How to Use.................................................................................................................... 189
16.4 Enterprise MIB ............................................................................................................... 191
16.4.1 l44notificationTBL Group .......................................................................................... 192
16.4.2 l44systemTBL Group ................................................................................................ 193
16.4.3 l44statusTBL Group ................................................................................................. 194
16.4.4 l44referenceTBL Group ............................................................................................. 198
16.4.5 l44blackTBL Group ................................................................................................... 200
16.4.6 l44audioTBL Group .................................................................................................. 209
16.4.7 l44ltcTBL Group ....................................................................................................... 211
16.4.8 l44cw1ppsTBL Group ............................................................................................... 214
16.4.9 l44trapTBL Group .................................................................................................... 214
16.4.10 lt4670ser02 Group ................................................................................................... 214
16.4.11 lt4670ser03 Group ................................................................................................... 265
16.5 Extended Trap................................................................................................................ 275
17 WEB BROWSER.......................................................................................... 277
17.1 Operating Environment ................................................................................................... 277
17.2 How to Use.................................................................................................................... 277
17.3 Procedure ...................................................................................................................... 279
17.4 Screen Description ......................................................................................................... 282
17.4.1 STATUS Screen ....................................................................................................... 282
17.4.2 REFERENCE Screen .................................................................................................. 285
17.4.3 BLACK Screen ......................................................................................................... 286
17.4.4 AUDIO Screen ......................................................................................................... 287
17.4.5 LTC & CW/1PPS Screen ............................................................................................ 288
17.4.6 SDI Screen (SER02) ................................................................................................. 289
Page 10
17.4.7 PTP Screen (SER03) ................................................................................................ 294
17.4.8 SYSTEM Screen ....................................................................................................... 297
18 MAINTENANCE .......................................................................................... 300
18.1 Calibration and Repair ..................................................................................................... 300
18.2 Replacement of Parts ...................................................................................................... 300
18.2.1 Power Supply Unit Replacement ................................................................................ 301
18.2.2 Front Fan Unit Replacement ...................................................................................... 303
18.2.3 Rear Fan Unit Replacement ....................................................................................... 306
19 APPENDIX ................................................................................................. 308
19.1 List of Settings ............................................................................................................... 308
19.1.1 REFERENCE CONFIG Menu ....................................................................................... 308
19.1.2 BLACK CONFIG Menu ............................................................................................... 308
19.1.3 AUDIO CONFIG Menu ............................................................................................... 309
19.1.4 LTC CONFIG Menu ................................................................................................... 309
19.1.5 CW/1PPS CONFIG Menu ........................................................................................... 310
19.1.6 SDI CONFIG Menu (SER02) ...................................................................................... 310
19.1.7 PTP CONFIG Menu (SER03) ...................................................................................... 312
19.1.8 SYSTEM CONFIG Menu ............................................................................................. 313
19.2 Release Notes ................................................................................................................ 316
Page 11
I

GENERAL SAFETY SUMMARY

Read This before Using the Instrument
This instrument should only be used by persons with sufficient knowledge of electronics who thoroughly understand the contents of this manual.
This instrument is not designed or manufactured for households or ordinary consumers. If unqualified personnel are to use the instrument, be sure the instrument is handled under the supervision of qualified personnel (those who have electrical knowledge). This is to prevent the possibility of personal injury or damage to the instrument.
Note about Reading This Manual
The contents of this manual contain specialized terminology and may be difficult to understand. If you have any questions about the contents of this manual, please contact your local LEADER agent.
Symbols and Terms
The following symbols and terms are used in this instruction manual and on the instrument to indicate important warnings and notes.
<Symbol>
This symbol appears in this instruction manual and on the instrument to indicate an area where improper handling could result in personal injury, damage to the instrument, or malfunction of the instrument or devices connected to it. When you encounter this symbol on the instrument, be sure to refer to the information in this instruction manual that corresponds to the area that the symbol marks.
<Term>
Ignoring the precautions that this term indicates could lead to death or serious injury.
<Term>
Ignoring the precautions that this term indicates could lead to personal injury or damage to the instrument.
Page 12
II
GENERAL SAFETY SUMMARY
Read the warnings and information below thoroughly to avoid death, personal injury, fire, electric shock,
and damage and deterioration of the instrument.
Warnings Concerning the Case and Panels
• Do not remove the instrument's case or panels for any reason.
• Do not insert foreign materials, such as metal and flammable objects, or allow liquid to enter the instrument.
• Do not operate this instrument with wet hands.
• Do not install the instrument in a way that makes it difficult to operate the panel.
Installation Environment
• Use this instrument within a temperature range of 0 to 40°C at a relative humidity of 85% or less; ensure that there is no risk of condensation forming.
• Do not use the instrument with its vents blocked or in a high temperature environment.
• If there is a possibility that the instrument has condensation within it, wait for approximately 30 minutes before turning on the power.
• Do not use this instrument in an environment where flammable gases, explosive gases, or steam is emitted or stored.
If You Notice Something Wrong during Operation
• If you notice smoke, fire, strange odor, or any other anomaly while you are operating it, stop operation immediately, and remove the power cord plug from the outlet.
Warnings Concerning the Power Source
• Do not use a power source with a voltage other than the rated line voltage for the instrument.
• Be sure to use a power frequency of 50 or 60 Hz.
• Use a power cord that meets the safety standards of the country that you are using it in.
• If the power cord is damaged, stop using it.
• Do not install the instrument in a way that makes it difficult to operate the power cord plug.
• When removing the power cord from the power outlet, be sure to hold the plug; do not pull on the cord.
• When using the instrument, make sure that it is grounded using a grounded power cord.
Warnings Concerning the SFP Transceiver
• For safety reasons, use the Leader-designated SFP transceiver.
Page 13
III
GENERAL SAFETY SUMMARY
Cautions Concerning the Input and Output Connectors
• Do not apply signals exceeding the specifications in this instruction manual to the input connectors.
• Do not short circuit or apply an external voltage to the output connectors.
If You Will Not Use the Instrument for an Extended Period of Time
• If you will not use the instrument for an extended period of time, remove the power plug from the outlet.
Cautions Concerning the Ethernet Port
• When you are connecting the instrument to the communication provider's equipment, connect to the Ethernet port through a hub that is authorized for use in the country that you are using the instrument in.
Page 14
IV
GENERAL SAFETY SUMMARY
Routine Maintenance
When you clean the instrument, remove the power plug from the outlet. Do not use thinner or benzene when you clean the instrument's case, panels, or knobs. Doing so could lead to paint chipping or the corrosion of plastic components. To clean the case, panels, and knobs, use a soft cloth with mild detergent, and wipe gently. While cleaning, make sure that foreign materials, such as water and detergent, do not enter the instrument. If liquid or a metal object enters into the instrument, fire or electric shock may result.
About the European WEEE Directive
This instrument and its accessories are subject to the European WEEE Directive. Follow the applicable regulations of your country or region when discarding this instrument or its accessories. Follow the EU Battery Directive when discarding the batteries that you removed from this instrument. (WEEE stands for Waste Electrical and Electronic Equipment.)
Follow the warnings and precautions that have been listed in this section to use the instrument correctly and safely. Precautions are also contained in various other sections of this instruction manual. To use the instrument correctly, be sure to follow those precautions as well.
If you have any questions or comments about this instruction manual, please contact your local LEADER agent.
Page 15

1 INTRODUCTION

1
1 INTRODUCTION
Thank you for using the LEADER instrument. To use this instrument safely, read this instruction manual thoroughly, and make sure that you know how to use the instrument properly.
If some point about the operation of this instrument is still unclear after you have read this instruction manual, refer to the contact information on the back cover of the manual to contact LEADER, or contact your local LEADER agent.

1.1 User Registration

Register as a user to access the latest product Information. To register, go to the user registration page of the Leader website.
https://www.leader.co.jp/en/member/registry/

1.2 Scope of Warranty

This LEADER instrument has been manufactured under the strictest quality control guidelines. If a failure occurs when the instrument is used in normal conditions, we will repair the instrument free of charge for a period of one year from the date of purchase. The proof of purchase (delivery slip, receipt bill, etc.) may be used as a warranty. Keep it in a safe place.
LEADER shall not be obligated to furnish the following free services during the warranty period.
1. Repair of malfunction or damages resulting from fire, natural calamity, or improper voltage applied by the user.
2. Repair of a product that has been improperly repaired, adjusted, or modified by personnel other than a factory-trained LEADER representative.
3. Repair of malfunctions or damages resulting from improper use.
4. Repair of malfunctions caused by devices other than this instrument.
5. Repair of malfunctions or damages without the presentation of a proof of purchase or receipt bill for the instrument.
This Warranty is valid only in Japan.

1.3 Trademark Acknowledgments

The company and product names in this document are trademarks or registered trademarks of their respective holders.
Page 16
1 INTRODUCTION
2

1.4 Operating Precautions

1.4.1 Power Supply Voltage

Confirm the voltage of the power source before you connect the power cord to it. The power requirements of this instrument are indicated on its rear panel. Only use a power source that supplies a voltage within the operating voltage range and has a frequency of 50/60 Hz.

1.4.2 Maximum Allowable Input Voltage

The maximum signal voltage that can be applied to the input connectors is indicated below. Do not apply excessive voltage to the connectors. Doing so may damage the device or lead to injury.
Table 1-1 | Maximum allowable input voltage
Input Connector
Maximum Allowable Voltage
GENLOCK/CW IN GENLOCK
±5 V (DC + peak AC)
CW
1 Vrms (50 Ω termination)
LTC/REMOTE LTC
4Vp-p
REMOTE
5V
L-SYNC
3.3V
GNSS IN (SER01)
3.3Vp-p

1.4.3 Mechanical Shock

This instrument contains sensitive components, so it may be damaged if it is dropped or otherwise exposed to a strong shock.

1.4.4 Electrostatic Damage

Electronic components can be damaged by static discharge. Static electricity can build up in the core wire of a coaxial cable. Before connecting a coaxial cable to an I/O connector of the instrument, short the core wire of the cable with the external conductor.

1.4.5 Warming Up

To ensure more accurate measurements, turn ON the instrument approximately 30 minutes before you intend to use it to allow its internal temperature to stabilize.
Page 17

2 PRODUCT CONFIGURATION

3
2 PRODUCT CONFIGURATION

2.1 Main Unit

The configuration of the LT4670 instrument is as shown below.
Table 2-1 | Instrument
Model Number
Model Name
Functions
Port
Number
of Ports
LT4670
SYNC GENERATOR
Genlock/CW Input
BNC 2 Analog Black Output
BNC 6 CW/1PPS Output
BNC 1 Word-Clock Output
DIN 1.0/2.3
1
Silence Output
DIN 1.0/2.3
1
AES/EBU Output
DIN 1.0/2.3
1
Ethernet
RJ-45
1
LTC/Remote
D-Sub 26pin
1
Inter-instrument Synchronization (L-SYNC)
D-Sub 15pin
1
Power Requirements
Power Supply
1

2.2 Hardware Options

The following hardware options can be added to the LT4670.
Hardware options will be added by LEADER or the designated service personnel. Contact your local LEADER agent.
Table 2-2 | Hardware options
Model Number
Model Name
Functions
Port Added
Number
of Ports
LT4670-SER01
GNSS
GPS / GLONASS / GALILEO / BDS / QZSS Synchronization
BNC
1
LT4670-SER02
SDI
3G-SDI / HD-SDI / SD-SDI Output
BNC 2 LT4670-SER03
PTP
PTP
SFP/SFP+
2
LT4670-SER11
POWER UNIT
Redundant Power Supply
Power Supply
1
Page 18
2 PRODUCT CONFIGURATION
4

2.3 Software Options

The following software options can be added to the LT4670.
To add a software option, provide your local LEADER agent with the instrument’s MAC address and serial number. We will issue a license key.
When you receive the license key, add it using "SYSTEM CONFIG > LICENSE INFO. > LICENSE KEY INPUT". Each instrument requires a unique license key. You cannot use the same key for multiple instruments.
Table 2-3 | Software options
Model Number
Model Name
Functions
LT4670-SER21
4K 3G-Quad Link
4K 3G-Quad Link Output (This requires two LT4670-SER02 units.)
MAC Address
You can check the MAC address in "STATUS > CONFIG > SYSTEM > MAC ADDRESS".
Serial Number
You can check the serial number on the rear panel or in "STATUS > CONFIG > SYSTEM > MAIN". The upper 7-digit number represents the serial number.
[ M A C   A D D R E S S ]
|}
0 0 : 0 0 : 0 0 : 0 0 : 0 0 : 0 0
[ M A I N : 0 0 / 0 0 0 0 0 0 0 ]
|}
C 5 : 0 0 0 0 0 0 0 0 C 1 0 : 0 0 0 0 0 0 0 0
Page 19

3 SPECIFICATIONS

5
3 SPECIFICATIONS

3.1 General

The LT4670 is a 1U full-rack size sync signal generator that outputs analog video sync signals and audio word-clock signals. The genlock function allows operation synchronized with input signals.
The genlock function has a stay-in-sync function that maintains the phase when an error occurs in the input analog video sync signal. Adding the power option provides redundant operation. The power supply unit and fan can be replaced without turning off the power of the LT4670 main unit. These features make it possible to configure a highly reliable system.
The LT4670 has six independent standard outputs of the analog sync signal output, digital audio output, word-clock output, and LTC I/O. Also, options are available for GNSS and PTP synchronization, arbitrary pattern output using 3G-SDI (4K Quad), HD-SDI, and SD-SDI, etc. These options are designed to enable the management of the optimal synchronization system for your application.

3.2 Features

3.2.1 LT4670

Genlock Function
Various output signals can be synchronized by applying NTSC/PAL black burst signals, which are analog video sync signals, and HDTV tri-level sync signals. NTSC/PAL black burst signal with field reference pulse and NTSC black burst signal with 10 field IDs are also supported. The 10 MHz CW lock is also supported as a standard feature.
Stay-in-Sync and Slow Lock Functions
A stay-in-sync function is available in case errors occur at the genlock input. In addition, a slow lock function is available to reduce the shock that occurs when genlock is performed again based on stay-in-sync. This makes it possible to construct an extremely reliable synchronization system.
Analog Video Sync Signal Output
Six analog video sync signals can be output. The phase of each output can be adjusted independently. NTSC/PAL black burst signal with field reference pulse and NTSC black burst signal with 10 field IDs are also supported.
Word-Clock Signal Output
The LT4670 can output a 48 kHz word-clock signal synchronized with video signals.
Page 20
3 SPECIFICATIONS
6
AES/EBU Signal Output
This option can output a 48 kHz AES/EBU signal synchronized with video signals. (AES/EBU connector) It is also equipped with a AES/EBU signal output compatible with DARS. (SILENCE connector)
CW/1PPS Output
The CW/1PPS output can output 10 MHz CW or 1PPS, whichever is selected.
Time Code I/O
The time code generator can run in free run mode based on internal time information. Based on the NTP server, LTC, VITC, GNSS (SER01), or PTP (SER03) time information, it can embed the LTC3 system output and analog video sync signal output in VITC, as well as the SDI (SER02) output in ATC (LTC/VITC).
LTC I/O
The LTC has three independent outputs for an input. An offset time can be set for each output with respect to the frame rate and reference time.
Remote Connector
The remote connector can be used to load presets and transmit two alarm outputs.
Inter-instrument Synchronization Control (L-SYNC)
In a redundant system, the time can be synchronized by connecting the main and backup devices that are synchronized with the same analog video sync signal via L-SYNC.
Real Time Clock
The real time clock is backed up by a battery. There is no need to reset the clock even when the power is turned off and then back on.
Ethernet
Control is exerted based on the SNMP. When an error is detected, a TRAP is issued. Also, this instrument can be controlled using the HTTPS (future support), HTTP, and REST-API (future support). When connected to an NTP server as an NTP client, the instrument can be used for internal clock synchronization or as an NTP server.
Preset Memory Function
Up to 10 presets can be saved. Convenient registered presets can be recalled during operation. The LT4670 can be started with the same settings every time.
Page 21
3 SPECIFICATIONS
7
External Memory Support
The log can be saved and preset data can be written and saved from the panel using USB memory devices.
Logging Function
The operation status can be logged to internal memory or external memory.
Last Memory Function
When the power is turned on, it starts up with the settings when the power was turned off last time.

3.2.2 LT4670-SER01 (GNSS)

GNSS Sync
A GNSS antenna can be connected to generate and output signals by locking to the frequency and clock obtained from the GPS, GLONASS, GALILEO, BDS, and QZSS. It also features a stay in sync function, which retains the phase and frequency of the output signal when GNSS signals are lost.

3.2.3 LT4670-SER02 (SDI)

Triple-rate SDI Ready
The SDI signal output supports 3G-SDI (level A and level B), HD-SDI, and SD-SDI. There are two independent SDI signal output connectors, and different patterns and phases can be set for each. Also, two SER02 units can be mounted, and up to four independent SDI signals can be output. Moreover, adding a 4K option (SER21) supports the 4K 3G-Quad Link.
User Pattern Generation
In addition to internal patterns such as the color bar, SD and HD (2K) user patterns can be output.
ID Character Overlay
ID characters can be overlaid at any position on the display. In addition, ID characters can be scrolled horizontally or displayed in a blinking state for checking whether the display has frozen.
Logo Mark Overlay
24-bit full-color bitmap data can be overlaid as a logo mark at any position on the display at a 640 (dots) × 480 (lines) VGA size.
Safety Area Markers
90% and 80% safety area markers can be overlaid on the display. For 3G-SDI and HD-SDI, a 4:3 aspect marker can be overlaid.
Page 22
3 SPECIFICATIONS
8
Pattern Scrolling
This option is equipped with a function for scrolling patterns in eight directions. The moving speed can be varied.
Moving Box
A moving box can be overlaid on the display. Its color, size, and moving speed can be varied.
Circle
90%, 80%, and 70% circles can be overlaid on the display. Their brightness can be changed, and they can be displayed in a blinking state.
Time Code
A time code can be overlaid at any position on the display. Its character size and brightness can be changed.
Audio Embedding
Embedded audio of 16 channels (four channel × four groups) can be embedded. The frequency, level, and the like can be set for each channel.
Lip Sync Pattern
Lip sync patterns in which the video and audio are synchronized can be output. By using a waveform monitor that features a lip sync measurement function, such as the Leader’s LV5600, it is possible to measure the offset between the video and audio in SDI signal transmissions.

3.2.4 LT4670-SER03 (PTP)

PTP Leader Function
This option supports the Precision Time Protocol defined in IEEE1588-2008 and operates as a PTP grand master. SMPTE2059, AES67, and General profiles are supported. The PTP time source is obtained from the internal clock, NTP server, GNSS, VITC, or LTC.
PTP Follower Function
When a host PTP grand master is present in the system, this option operates as a PTP follower and can operate as a PTP leader for lower devices.
Two Independent PTP Ports
Since two PTP engines are mounted, a PTP system can be constructed for each of them as an independent grand master. The two engines can be used as followers. (The leader can be selected automatically or arbitrarily by the user.) It is also possible to use one engine as a follower and the other as the leader.
10GbE Support
A 10GbE SFP+ module, sold separately, can be used.
Page 23
3 SPECIFICATIONS
9
Local PTP Function
When genlocked to the analog video sync signal or HDTV tri-level sync signal, this function obtains time information from an external time source, such as a GNSS or NTP server. It can adjust the time according to the phase information of the genlocked sync signal and redistribute the PTP time.

3.2.5 LT4670-SER11 (POWER UNIT)

Redundant Power Supply
You can make the power supply redundant. When errors occur in power supply units, alarms are indicated on the instrument panel. Errors can also be output as alarms using SNMP.

3.2.6 LT4670-SER21 (4K 3G-Quad Link)

4K 3G-Quad Link Output
Two LT4670-SER02 (SDI) options are featured. When this option is enabled, the 4K 3G-Quad Link can be output.
4K Internal Pattern Generation (future support)
In addition to the internal patterns of LT4670-SER02, the following patterns can be output.
・UHD Color Bar ARIB STD-B66 ・HLG CB ITU-R BT.2111 HLG narrow range ・S-LOG3(Live HDR) Ver1.11 narrow range scale
User Pattern Generation
In addition to internal patterns such as the color bar, 4K user patterns can be output.
ID Character Overlay
ID characters can be overlaid at any position on the display. In addition, ID characters can be scrolled horizontally or displayed in a blinking state for checking whether the display has frozen.
Logo Mark Overlay
24-bit full-color bitmap data can be overlaid as a logo mark at any position on the display at a 640 (dots) × 480 (lines) VGA size.
Safety Area Markers
90% and 80% safety area markers can be overlaid on the display. A 4:3 aspect marker can also be overlaid.
Pattern Scrolling
This option is equipped with a function for scrolling patterns in eight directions. The moving speed can be varied.
Page 24
3 SPECIFICATIONS
10
Moving Box
A moving box can be overlaid on the display. Its color, size, and moving speed can be varied.
Circle
90%, 80%, and 70% circles can be overlaid on the display. Their brightness can be changed, and they can be displayed in a blinking state.
Time Code
A time code can be overlaid at any position on the display. Its character size and brightness can be changed.
Audio Embedding
Embedded audio of 16 channels (four channel × four groups) can be embedded. The frequency, level, and the like can be set for each channel.
Lip Sync Pattern
Lip sync patterns in which the video and audio are synchronized can be output. By using a waveform monitor that features a lip sync measurement function, such as the Leader’s LV5600, it is possible to measure the offset between the video and audio in SDI signal transmissions.
Page 25
3 SPECIFICATIONS
11

3.3 Standards

3.3.1 LT4670

General Specifications
Environmental Conditions
Operating Temperature 0 – 40°C Operating Humidity Range 85% RH or less (no condensation) Optimal Temperature 10 – 35°C Operating Environment Indoors Operating Altitude Up to 2,000 m Overvoltage Category II Pollution Degree 2
Power Supply
Voltage 100 – 240 VAC Voltage Variation ±10% Power Consumption 150 W max. (when all options are used)
Dimensions 482 (W) × 44 (H) × 400 (D) mm (excluding
protrusions)
Weight 4.15 kg (excluding options)
5.37 kg (including options)
Accessories Power cord
AC cord clamp General safety summary
Sold Separately SFP transceiver (LC2141 / LC2142 / LC2148 / LC2149)
GNSS antenna Fan unit (LP2184) LTC cable (LC2185)(for connecting with LT4448) L-SYNC cable (LC2186)
Power Supply Unit
Number of Units in Main Unit
Standard 1 Maximum 2 (when LT4670-SER11 is installed)
Power Supply Redundancy When LT4670-SER11 is installed Replacement Method The installed LT4670-SER11 can be replaced without
turning off the power of the main unit.
Alarm A power supply alarm is indicated on the LED and LCD
and notified by an SNMP trap.
Fan Unit
Number of Fans 2 (one on front, one on rear) Replacement Method The fan can be stopped using the panel and replaced
without turning off the power of the main unit.
Alarm A fan alarm is indicated on the LED and LCD and
notified by an SNMP trap.
Page 26
3 SPECIFICATIONS
12
Corresponding Standard
Analog Video Sync Signal
NTSC Black Burst Signal SMPTE ST 170, SMPTE ST 318, SMPTE RP 154 PAL Black Burst Signal ITU-R BT 1700, EBU N14 HD Tri-level Sync Signal SMPTE ST 240, SMPTE ST 274, SMPTE ST 296
AES/EBU Signal ANSI S4.40, AES3-2009, AES11-2009, SMPTE ST 276 LTC Signal SMPTE 12M-1 Phase Management SMPTE ST 2059-1
I/O Connectors
Genlock Input Connector
Connector 2 BNC connectors Input Signal Analog composite sync signal HD Tri-level Sync Signal Analog composite sync signal Format Loop-through Input Impedance 47 kΩ Maximum Input Voltage ±5 V (DC + peak AC) Operating Input Level Range ±6 dB External Lock Range ±5 ppm Jitter 1 ns (when genlock is in use)
10 MHz CW Input Connector
Connector 1 BNC connector (used in combination with the genlock
input connector) Input Impedance 47 kΩ (used with 50 Ω terminated to the loop-through) Input Signal Level 0.5 - 1 Vrms (50 Ω termination) Input Signal Frequency 10 MHz Locking Frequency Range ±5 ppm
10 MHz CW/1PPS Output Connectors
Connector 1 BNC connector (used in combination with 10 MHz CW
and 1PPS) Output Amplitude Signal Level
10 MHz CW 2 Vp-p ± 20% (1 Vrms) for square waves; 50 Ω
termination
1PPS 4.8 ± 0.5 V (no termination, high level)
2.4 ± 0.25 V (50 Ω termination, high level) Output Impedance 50 Ω unbalanced Output Signal Frequency 10 MHz/1PPS
Page 27
3 SPECIFICATIONS
13
LTC I/O Connector
Connector D-sub 26-pin (female) LTC
Number of Inputs 1 Input Impedance 1 kΩ (balanced)
500 Ω (unbalanced) Input Signal Level 0.5 - 4 Vp-p Number of Outputs 3 Output Impedance 24 Ω balanced Output Signal Level 2 Vp-p ± 10%
Analog Video Sync Signal Output Connector
Connector 6 BNC connectors, 6 outputs Output Signal NTSC black burst signal, PAL black burst signal, HD tri-
level sync signal
Output Impedance 75 Ω Sync Level
NTSC 40±1IRE PAL -300±6mV HD ±300±6mV Blanking 0 ± 15 mV
AES/EBU Digital Audio Output Connector
Connector 1 DIN 1.0/2.3 connector Output Amplitude 1 Vp-p ± 0.1 V Output Impedance 75 Ω unbalanced
AES/EBU Silence Output Connector
Connector 1 DIN 1.0/2.3 connector Output Amplitude 1 Vp-p ± 0.1 V Output Impedance 75 Ω unbalanced
Word-Clock Output Connector
Connector 1 DIN 1.0/2.3 connector Output Frequency 48 kHz Output Amplitude 4.8 V or more (no termination, high level)
2.4 V or more (75 Ω termination, high level)
Page 28
3 SPECIFICATIONS
14
Control Connectors
Ethernet Port
Standard IEEE 802.3 Protocol
SNMP v2c/v3
Command control, status query, trap transmission REST-API (future support) Command control, status query HTTP/HTTPS (HTTPS to be supported in the future)
Monitoring and operation using a browser NTP Internal clock synchronization, time distribution
Connector RJ-45 Type 10BASE-T, 100BASE-TX, 1000BASE-T (auto switching)
USB Port
Standard USB 2.0 Supported Media USB memory device Supported Format FAT32 Functions Preset, logo, ID character, and user pattern loading;
preset and log saving; MIB file retrieval; authentication
key retrieval (future support); firmware update
Connector USB Type A
Remote Connector
Connector Shape D-sub 26-pin (female) Locking Screw Inch screw (No.4-40UNC) Number of Ports 1 Control Signal
Preset Recall LV-TTL level (low active) Alarm Output HC-CMOS level
Input Voltage Range (Preset Recall) 0 - 5 VDC
All inputs are pulled up to +3.3 V (control is also
possible using +5 V).
Output Voltage Range (Alarm Output)
0 - 5 VDC
Functions Preset recall
Alarm output (when an error occurs, when the fan
malfunctions, or when the power supply malfunctions)
Page 29
3 SPECIFICATIONS
15
Inter-instrument Synchronization Connector (L-SYNC)
Connector Shape D-sub 15-pin (female) Number of Ports 1 Control Signal LV-CMOS
6 main-side outputs
6 backup-side inputs
Input Voltage Range 0 - 3.3 VDC Function The time of the two instruments is synchronized in a
redundant configuration.
* It is not supported when the reference signal format is 23.98 Hz.
LCD
Number of Characters 24 characters × 2 lines Backlight On/off
Genlock Function
Signal Format NTSC BB, NTSC BB+REF, NTSC BB+ID, NTSC
BB+REF+ID, PAL BB, PAL BB+REF,
525/59.94I, 525/59.94P, 625/50I, 625/50P,
1125/60P, 1125/59.94P, 1125/50P,
1125/60I, 1125/59.94I, 1125/50I,
1125/30P, 1125/29.97P, 1125/25P, 1125/24P,
1125/23.98P, 1125/24PsF, 1125/23.98PsF,
750/60P, 750/59.94P, 750/50P, 750/30P, 750/29.97P,
750/25P, 750/24P, 750/23.98P
Timing Adjustment
Adjustment Range
FINE ±100 (in units of 0.5 ns)
Reference Source
Internal Reference Signal INTERNAL External Reference Signal GENLOCK FMT-AUTO / GENLOCK FMT-MANUAL /
10MHz CW / GNSS (SER01) / PTP (SER03)
Recovery Mode
AUTO Resynchronizes according to the auto setting when the
external reference signal recovers.
MANUAL Retains the STAY IN SYNC state when the external
sync signal recovers.
Auto Setting
IMMEDIATE Resets the lock when the external sync signal recovers. FAST Quickly resynchronizes when the external sync signal
recovers.
SLOW Slowly resynchronizes when the external sync signal
recovers.
Page 30
3 SPECIFICATIONS
16
Manual Setting
IMMEDIATE Resets the lock when the external sync signal recovers
and REFERENCE READJUST operation is performed.
FAST Quickly resynchronizes when the external sync signal
recovers and REFERENCE READJUST operation is
performed.
SLOW Slowly resynchronizes when the external sync signal
recovers and REFERENCE READJUST operation is
performed.
REFERENCE READJUST Resynchronizes immediately.
Stay in Sync Function Retains the frequency (video phase) immediately
before error occurrence when an error occurs in the
external reference signal.
Retains the previous frequency if the 10 MHz CW signal
is interrupted when 10 MHz CW is input.
Analog Video Sync Signal Output
Signal Format Each of the 6 outputs can be configured independently.
NTSC BB, NTSC BB+REF, NTSC BB+ID, NTSC BB+REF+ID, NTSC BB+SETUP, NTSC BB+S+REF, NTSC BB+S+ID, NTSC BB+S+R+ID, PAL BB, PAL BB+REF, 525/59.94I, 525/59.94P, 625/50I, 625/50P, 1125/60P, 1125/59.94P, 1125/50P, 1125/60I, 1125/59.94I, 1125/50I, 1125/30P, 1125/29.97P, 1125/25P, 1125/24P, 1125/23.98P, 1125/24PsF, 1125/23.98PsF, 750/60P, 750/59.94P, 750/50P, 750/30P, 750/29.97P, 750/25P, 750/24P, 750/23.98P
Timing Adjustment Each of the 6 outputs can be configured independently.
Adjustment Range
NTSC Black Burst Signal ±5 frames PAL Black Burst Signal ±2 frames HD Tri-Level Sync Signal 1 frame (entire frame)
Adjustment Unit
NTSC/PAL Black Burst Signal In units of 0.0185 μs (54 MHz clock) HD Tri-Level Sync Signal In units of 0.0135 μs (74.25/1.001 MHz clock unit or
74.25 MHz clock unit)
Page 31
3 SPECIFICATIONS
17
AES/EBU Digital Audio Output
Timing Adjustment
Adjustment Range ±1 AES/EBU frame (±511)
Adjustment Unit In units of 512 fs (24.576 MHz) Sampling Frequency 48 kHz sampling (synced with the video signal) Resolution 20 bits, 24 bits Pre-emphasis OFF, 50/15, CCITT (only the CS bit is switched)
Frequency SILENCE, 400 Hz, 800 Hz, 1 kHz
Level -60 – 0 dBFS (in units of 1 dBFS)
Audio Click OFF, 1, 2, 4 sec
Lip Sync Synchronization with SDI-1
Sampling Clock Accuracy Grade 2 (±10 ppm)
* The frequency, level, and audio click can be set for each channel.
AES/EBU Silence Output
Timing Adjustment
Adjustment Range ±1 AES/EBU frame (±511)
Adjustment Unit In units of 512 fs (24.576 MHz) Sampling Frequency 48 kHz sampling (synced with the video signal) Resolution 20 bits, 24 bits Pre-emphasis OFF Frequency SILENCE Level MUTE Sampling Clock Accuracy Grade 2 (±10 ppm)
* Supports DARS. * When EQUAL TO AES/EBU is set to on, the same signal as the AES/EBU digital audio signal is output.
Word-Clock Output
Timing Adjustment
Adjustment Range ±1 AES/EBU frame (±511)
Adjustment Unit In units of 512 fs (24.576 MHz)
Time Code Function
Reference Time Internal / NTP / LTC / VITC / GNSS (SER01) / PTP
(SER03) Frame Rate 30 / 29.97 / 25 / 24 / 23.98 Hz Dropped Frame Mode On/Off JAM SYNC
Application Setting Set the application time with a timer.
ATC Setting
LTC Insertion Setting On/Off VITC Insertion Setting On/Off
Page 32
3 SPECIFICATIONS
18
Black Setting
VITC Insertion Setting On/Off Superimposed Line
NTSC 10 - 20 (*1) PAL 6 - 22 (*2)
AES/EBU Setting
Insertion Setting On/Off
LTC Setting
Output Setting On/Off
Leap Second
Application Setting Set the application date/time with a timer.
(The PTP (SER03) does not support timer setting.) Daylight Savings Time
Application Setting Set the application date and time with a timer.
*1 When REF is included in the black format, it cannot be superimposed on the 10th line.
When ID is included in the black format, it cannot be superimposed on the 15th line.
*2 When the black format is PAL BB+REF, it cannot be superimposed on the 7th line.
Preset Function
Preset Saves the panel settings. Number of Presets 10 Recall Method Panel, remote connector, SNMP, REST-API (future
support), browser Copy Method Copy from this instrument to a USB memory device or
copy from the USB memory device to this instrument.
* Logo data and device-specific information (IP address, time, etc.) cannot be saved.
Logging Feature
Saved Items Genlock status change, instrument operation, alarm
information, attention information Number of Logs Up to 1000 Copy Method Copy from this instrument to a USB memory device. Display Panel, browser (future support)
Page 33
3 SPECIFICATIONS
19

3.3.2 LT4670-SER01 (GNSS)

I/O Connectors
GNSS Input Connectors
Connector 1 BNC connectors Input Impedance 50 Ω Antenna, Pre-amp Power Supply
Voltage 5 V / 3.3 V / OFF Current 50 mA max. (built-in overcurrent protection circuit)
GNSS Lock
GNSS Receiver
Receive Frequency
GPS 1575.42MHz (L1) GLONASS 1602 MHz + k×562.5kHz (L1OF)
(k = -7,…,5,6)
GALILEO 1575.42MHz (E1-B/C) BDS 1561.098MHz (B1) GPS+QZSS 1575.42MHz (L1)
Status GNSS No Fix, ADJUST FREQ TO GNSS, ADJUST PHASE
TO GNSS, TRACKING, LOCK, STAY, RECOVERY Stay in Sync Function Retains the previous frequency and phase when the
GPS, GLONASS, GALILEO, BDS, or GPS+QZSS signal is
interrupted.
Page 34
3 SPECIFICATIONS
20

3.3.3 LT4670-SER02 (SDI)

Corresponding Standard
SDI Embedded Audio
3G, HD SMPTE ST 299 SD SMPTE ST 272
SDI Payload ID SMPTE ST 352
SDI Formats and Standards
Table 3-1| HD and SD video signal formats and standards
Color System
Quantization
Image
Frame (Field) Frequency/Scanning
Corresponding
Standard
YCBCR 4:2:2
10bit
1280×720
60/59.94/50/30/29.97/25/24/23.98/P
SMPTE ST 292-1 SMPTE ST 296
1920×1080
60/59.94/50/I
SMPTE ST 292-1 SMPTE ST 274
30/29.97/25/24/23.98/P
30/29.97/25/24/23.98/PsF
SMPTE ST 292-1 SMPTE RP 211
720×487
59.94/I
SMPTE ST 259 720×576
50/I
Table 3-2 | 3G-A video signal formats and standards
Color System
Quantization
Image
Frame (Field) Frequency/Scanning
Corresponding
Standard
YCBCR 4:2:2
10bit
1920×1080
60/59.94/50/P
SMPTE ST 274 SMPTE ST 425-1
12bit
1920×1080
60/59.94/50/I
30/29.97/25/24/23.98/P
30/29.97/25/24/23.98/PsF
RGB 4:4:4
10bit
1280×720
60/59.94/50/30/29.97/25/24/23.98/P
SMPTE ST 296 SMPTE ST 425-1
1920×1080
60/59.94/50/I
SMPTE ST 274 SMPTE ST 425-1
30/29.97/25/24/23.98/P
30/29.97/25/24/23.98/PsF
12bit
1920×1080 60/59.94/50/I
30/29.97/25/24/23.98/P
Page 35
3 SPECIFICATIONS
21
Table 3-3 | 3G-B video signal formats and standards
Color System
Quantization
Image
Frame (Field) Frequency/Scanning
Corresponding
Standard
YCBCR 4:2:2
10bit
1920×1080
60/59.94/50/P
SMPTE ST 274 SMPTE ST 372 SMPTE ST 425-1
12bit
1920×1080
60/59.94/50/I
30/29.97/25/24/23.98/P
30/29.97/25/24/23.98/PsF
RGB 4:4:4
10bit
1920×1080
60/59.94/50/I
30/29.97/25/24/23.98/P
30/29.97/25/24/23.98/PsF
12bit
1920×1080
60/59.94/50/I
30/29.97/25/24/23.98/P
30/29.97/25/24/23.98/PsF
I/O Connectors
SDI Output Connector 2 BNC connectors Output Impedance 75 Ω Output Amplitude 800 mVp-p ± 10% Output Return Loss
5 MHz – 1.485 GHz 15 dB or more
1.485 GHz – 2.97 GHz 10 dB or more Overshoot Less than 10% Rise and Fall Times
3G 135 ps or less (20 – 80%) HD 270 ps or less (20 – 80%) SD 0.4 ns or more, 1.5 ns or less (20 – 80%)
DC Offset 0 ± 0.5 V
SDI Video Output
SDI Signal
Bit Rate
3G 2.970Gbps, 2.970/1.001Gbps HD 1.485Gbps, 1.485/1.001Gbps SD 270Mbps
Timing Adjustment
Adjustment Range Entire frame Adjustment Unit
V Lines H Clocks (148.5 MHz, 148.5/1.001 MHz, 74.25 MHz,
74.25/1.001 MHz, 27 MHz)
Page 36
3 SPECIFICATIONS
22
Selecting the Timing Reference SD and HD only; SERIAL only for 3G
SERIAL Signals are output at the timing defined in the signal
standard.
LEGACY Signals are output at the same timing as Leader’s
conventional signal generators.
Test Patterns
3G, HD 100% color bar, 75% color bar, multiformat color bar
(ARIB STD-B28, pattern 2 area can be set to 100% white, 75% white, or +I), check field, flat field white 100%, white 50%, black 0%, red 100%, green 100%, blue 100%
SD
525/ 59.94I 100% color bar, 75% color bar, SMPTE color bar, check
field, flat field white 100%, white 50%, black 0%, red 100%, green 100%, blue 100%
625/50I EBU color bar, BBC color bar, check field, flat field white
100%, white 50%, black 0%, red 100%, green 100%, blue 100%
User Pattern Display Select one from INT1 to INT4 for SD and HD,
respectively.
File Format 24-bit full color bitmap format (.bmp)
24/48-bit TIFF format (.tif) uncompressed only
Automatic Switching Automatically switches between selectable color bar
patterns.
Switch Time 1 – 255 sec
Pattern Scrolling
Direction Eight directions (up, down, left, right, and their
combinations)
Speed Range and Unit
Interlace In unit of fields
V ±256 lines (in 1-line steps) H ±256 dots (in 2-dot steps)
Progressive In unit of frames
V ±256 lines (in 1-line steps) H ±256 dots (in 2-dot steps)
* Not available when the check field pattern is selected.
Page 37
3 SPECIFICATIONS
23
Safety Area Markers
3G, HD Action safe area (90%)
Title safe area (80%) 4:3 aspect ratio (can be turned on and off separately)
SD Action safe area (90%)
Title safe area (80%) (can be turned on and off separately)
* Not available when the check field pattern is selected.
ID Characters
Number of Characters Up to 20 characters Size 32 × 32, 64 × 64, 128 × 128, 256 × 256 dots Brightness 100%, 75% (black only for the background) Display Position Anywhere on the display Display Position Adjustment Range
V 0 - 100% (in units of 1%) H 0 - 100% (in units of 1%)
Blinking Display (*1) On/Off
On Time 1 - 9 sec (in units of 1 sec) Off Time 1 - 9 sec (in units of 1 sec)
Scrolling (*1)
Function Scroll including the ID character background Direction Two directions (left and right) Speed Range and Unit
Interlace In unit of fields
±256 dots (in 2-dot steps)
Progressive In unit of frames
±256 dots (in 2-dot steps)
* Not available when the check field pattern is selected. *1 The blinking display and scrolling can be set simultaneously.
Logo Mark
Logo Mark Data 24-bit full-color data Maximum Size 640 (dots) × 480 (lines) (VGA size) Number of Logo Marks That Can Be Saved in the Instrument Up to 4 types Display Position Anywhere on the display Display Position Adjustment Range
V 0 - 100% (in units of 1%)
H 0 - 100% (in units of 1%) File Format 24-bit full color bitmap format (.bmp) Logo Mark Data Transfer The data is transfer from a USB memory device to the
instrument.
* Not available when the check field pattern is selected.
Page 38
3 SPECIFICATIONS
24
Component On/Off
Function Each of the Y/G, Cb/B, and Cr/R components can be
turned on and off independently.
* Not available when the check field pattern is selected.
Moving Box
Box Color White, yellow, cyan, green, blue, red, magenta, black Speed Setting V/H LOW / MIDDLE / HIGH Size Setting V/H SIZE 1 - 5
* Not available when the check field pattern is selected.
Circle
Display Position 90%, 80%, or 70% of the resolution Brightness 100% / 75% Blinking Display On/Off
On Time 1 - 9 sec (in units of 1 sec)
Off Time 1 - 9 sec (in units of 1 sec)
* Not available when the check field pattern is selected.
Time Code
Size 32 × 32, 64 × 64, 128 × 128, 256 × 256 dots Brightness 100%, 75% (black only for the background) Display Position Anywhere on the display Display Position Adjustment Range
V 0 - 100% (in units of 1%)
H 0 - 100% (in units of 1%)
* Not available when the check field pattern is selected.
Image Overlay
Display Priority Test pattern < Circle < Moving box < Safety area
marker < Logo mark < ID character < Time code (The display order cannot be changed.)
Simultaneous Display The test pattern, circle, moving box, safety area
marker, logo mark, ID character, and time code can be displayed simultaneously.
Embedded Audio
Embedded Channels Can be turned on and off at the group level.
16 channels (4 channels × 4 groups) Sampling Frequency 48 kHz sampling (synced with the video signal) Resolution 20 bits, 24 bits Pre-emphasis OFF, 50/15, CCITT (only the CS bit is switched) Frequency SILENCE, 400 Hz, 800 Hz, 1 kHz Level -60 – 0 dBFS (in units of 1 dBFS) Audio Click OFF, 1 sec, 2 sec, 4 sec
Page 39
3 SPECIFICATIONS
25
* Audio (including packets) cannot be embedded when the check field pattern is selected. * The frequency, level, and audio click can be set for each channel. * The audio click and digital audio are asynchronous. * Not available when lip sync is enabled. * The following limitations apply for SD (525/59.94I).
• For 16 channel output, the resolution is set to 20 bits.
• Up to three groups (12 channels) can be output at 24-bit resolution.
Lip Sync Pattern
Setting SDI1, SDI2, SDI3, and SDI4 can be set separately.
(SDI3 and SDI4 are additional options.)
* AES/EBU is synchronized with SDI1. * Not available when the check field pattern is selected. * Safety area markers, ID characters, logo marks, moving boxes, circles, and time codes cannot be
overlaid.
* The audio click of embedded audio is disabled, and audio synchronized to the lip sync pattern is
output.
User Payload (future support)
Setting On/Off
* The content of the user payload ID can be edited only with a web browser.

3.3.4 LT4670-SER03 (PTP)

Corresponding Standard
Internet Protocol Version IPv4 PTP Standard IEEE 1588 – 2008 Supported Profile SMPTE ST 2059 / AES67 / General
I/O Connectors
SFP/SPF+ connector
Number of Ports 2 Port Type SFP gauge Compliant Standard MSA Supported Modules and Types
SFP Transceiver RJ-45 1000Base-T SFP + Optical Transceiver 10GBase-SR and 10GBase-SW
* The SFP/SFP+ module is optional.
Page 40
3 SPECIFICATIONS
26
Leader Function
Number of Controllable Leader Devices 2 Communication Mode Multicast / Unicast / MIXED SMPTE / MIXED SMPTE
without negotiation
Domain Number 0 – 127 (SMPTE ST 2059) 0 – 255 (AES67 / General) Announce Message Rate (*1) 0.125s 8Hz / 0.25s 4Hz / 0.5s 2Hz / 1s 1Hz / 2s 0.5Hz
/ 4s 0.25Hz / 8s 0.125Hz / 16s 0.0625Hz
Sync Message Rate (*1) 0.0078s 128Hz / 0.015s 64Hz / 0.0312s 32Hz /
0.0625s 16Hz / 0.125s 8Hz / 0.25s 4Hz / 0.5s 2Hz / 1s
1Hz / 2s 0.5Hz / 4s 0.25Hz / 8s 0.125Hz / 16s
0.00625Hz Priority 1 0 – 255 Priority 2 0 – 255 Number of Connectable Followers 1000 (theoretical value when the sync message is 8
Hz)
*1 The message rate setting range varies depending on the profile.
Follower Function
Number of Controllable Follower Devices 2 Communication Mode Multicast / Unicast / MIXED SMPTE / MIXED SMPTE
without negotiation Domain Number 0 – 127 (SMPTE ST 2059) 0 – 255 (AES67 / General) Delay Message Rate 0.0078s 128Hz / 0.015s 64Hz / 0.0312s 32Hz /
0.0625s 16Hz / 0.125s 8Hz / 0.25s 4Hz / 0.5s 2Hz / 1s
1Hz / 2s 0.5Hz / 4s 0.25Hz / 8s 0.125Hz / 16s
0.00625Hz
Announce Timeout Count 2 - 10

3.3.5 LT4670-SER11 (POWER UNIT)

Power Supply Redundancy Supported Replacement Method Can be replaced without turning off the power of the
main unit. Alarm A power supply alarm is indicated on the LED and LCD
and notified by an SNMP trap.
Page 41
3 SPECIFICATIONS
27

3.3.6 LT4670-SER21 (4K 3G-Quad Link)

Corresponding Standard
SDI Embedded Audio SMPTE ST 299 SDI Payload ID SMPTE ST 352
SDI Formats and Standards
Table 3-4 | 3G-Quad Link video signal formats and standards (supported only for 4K 2-sample interleave)
Division
Transmission
System
Color
System
Quantization
Image
Frame Frequency/
Scanning
Corresponding
Standard
2 sample interleave
YCBCR 4:2:2
10bit
3840×2160
60/59.94/50/P
SMPTE ST 425-5 SMPTE ST 2036-1
4096×2160
60/59.94/50/48/47.95/P
SMPTE ST 425-5 SMPTE ST 2048-1
12bit
3840×2160
30/29.97/25/24/23.98/P
SMPTE ST 425-5 SMPTE ST 2036-1
4096×2160
30/29.97/25/24/23.98/P
SMPTE ST 425-5 SMPTE ST 2048-1
RGB 4:4:4
10bit
3840×2160
30/29.97/25/24/23.98/P
SMPTE ST 425-5 SMPTE ST 2036-1
4096×2160
30/29.97/25/24/23.98/P
SMPTE ST 425-5 SMPTE ST 2048-1
12bit
3840×2160
30/29.97/25/24/23.98/P
SMPTE ST 425-5 SMPTE ST 2036-1
4096×2160
30/29.97/25/24/23.98/P
SMPTE ST 425-5 SMPTE ST 2048-1
SDI Video Output
SDI Signal
Bit Rate
3G (QL) 2.970Gbps, 2.970/1.001Gbps
Timing Adjustment
Adjustment Range Entire frame Adjustment Unit
V Lines H Clocks (148.5 MHz, 148.5/1.001 MHz)
Test Patterns 100% color bar, 75% color bar, multiformat color bar
(ARIB STD-B28, pattern 2 area can be set to 100%
white, 75% white, or +I), check field, flat field white
100%, white 50%, black 0%, red 100%, green 100%,
blue 100%
Page 42
3 SPECIFICATIONS
28
4K Additional Test Patterns (future support)
UHDColorBar ARIB STD-B66 UHDTV MULTIFORMAT COLOR BAR HLGCB ARIB STD-B72 Color Bar Test Pattern for HLG HDR-TV
System
Recommendation ITU-R BT.2111 HLG
Slog3_LiveHDR_narrow_V11 S-Log3 (Live HDR) Ver.1.11 narrow range scale
User Pattern Display Select one from 4K (2SI) INT1 to INT4.
File Format 24-bit full color bitmap format (.bmp)
24/48-bit TIFF format (.tif) uncompressed only
Automatic Switching Automatically switches between selectable color bar
patterns.
Switch Time 1 – 255 sec
Pattern Scrolling
Direction Eight directions (up, down, left, right, and their
combinations)
Speed Range and Unit
Progressive In unit of frames
V ±256 lines (in 2-line steps) H ±256 dots (in 4-dot steps)
* Not available when the check field pattern is selected.
Safety Area Markers Action safe area (90%)
Title safe area (80%)
4:3 aspect ratio
(can be turned on and off separately)
* Not available when the check field pattern is selected.
ID Characters
Number of Characters Up to 20 characters Size 32 × 32, 64 × 64, 128 × 128, 256 × 256 dots Brightness 100%, 75% (black only for the background) Display Position Anywhere on the display Display Position Adjustment Range
V 0 - 100% (in units of 1%) H 0 - 100% (in units of 1%)
Blinking Display (*1) On/Off
On Time 1 - 9 sec (in units of 1 sec) Off Time 1 - 9 sec (in units of 1 sec)
Page 43
3 SPECIFICATIONS
29
Scrolling (*1)
Function Scroll including the ID character background Direction Two directions (left and right) Speed Range and Unit
Progressive In unit of frames
±256 dots (in 4-dot steps)
* Not available when the check field pattern is selected. *1 The blinking display and scrolling can be set simultaneously.
Logo Mark
Logo Mark Data 24-bit full-color data Maximum Size 640 (dots) × 480 (lines) (VGA size) Number of Logo Marks That Can Be Saved in the Instrument Up to 4 types Display Position Anywhere on the display Display Position Adjustment Range
V 0 - 100% (in units of 1%)
H 0 - 100% (in units of 1%) File Format 24-bit full color bitmap format (.bmp) Logo Mark Data Transfer The data is transfer from a USB memory device to the
instrument.
* Not available when the check field pattern is selected.
Component On/Off
Function Each of the Y/G, Cb/B, and Cr/R components can be
turned on and off independently.
* Not available when the check field pattern is selected.
Moving Box
Box Color White, yellow, cyan, green, blue, red, magenta, black Speed Setting V/H LOW / MIDDLE / HIGH Size Setting V/H SIZE 1 - 5
* Not available when the check field pattern is selected.
Circle
Display Position 90%, 80%, or 70% of the resolution Brightness 100% / 75% Blinking Display On/Off
On Time 1 - 9 sec (in units of 1 sec)
Off Time 1 - 9 sec (in units of 1 sec)
* Not available when the check field pattern is selected.
Page 44
3 SPECIFICATIONS
30
Time Code
Size 32 × 32, 64 × 64, 128 × 128, 256 × 256 dots Brightness 100%, 75% (black only for the background) Display Position Anywhere on the display Display Position Adjustment Range
V 0 - 100% (in units of 1%)
H 0 - 100% (in units of 1%)
* Not available when the check field pattern is selected.
Image Overlay
Display Priority Test pattern < Circle < Moving box < Safety area
marker < Logo mark < ID character < Time code (The display order cannot be changed.)
Simultaneous Display The test pattern, circle, moving box, safety area
marker, logo mark, ID character, and time code can be displayed simultaneously.
Embedded Audio
Embedded Channels Can be turned on and off at the group level.
16 channels (4 channels × 4 groups) Sampling Frequency 48 kHz sampling (synced with the video signal) Resolution 20 bits, 24 bits Pre-emphasis OFF, 50/15, CCITT (only the CS bit is switched) Frequency SILENCE, 400 Hz, 800 Hz, 1 kHz Level -60 – 0 dBFS (in units of 1 dBFS) Audio Click OFF, 1 sec, 2 sec, 4 sec
* Audio (including packets) cannot be embedded when the check field pattern is selected. * The frequency, level, and audio click can be set for each channel. * The audio click and digital audio are asynchronous. * Not available when lip sync is enabled.
Lip Sync Pattern
Setting On/Off
* Synchronized with AES/EBU. * Not available when the check field pattern is selected. * Safety area markers, ID characters, logo marks, moving boxes, circles, and time codes cannot be
overlaid.
* The audio click of embedded audio is disabled, and audio synchronized to the lip sync pattern is
output.
User Payload ID (future support)
Setting On/Off
* The content of the user payload ID can be edited only with a web browser.
Page 45

4 PANEL DESCRIPTION

31
4 PANEL DESCRIPTION

4.1 Front Panel

An overall and enlarged view of the front panel is shown below.
Figure 4-1 | Front panel (overall view)
Figure 4-2 | Front panel (enlarged view)
1 POWER 1
Lights in green when POWER1 is on. Lights red in the following cases.
・When an error occurs in the POWER1 fan ・When the power supply is redundant and an error occurs on POWER1 ・When the power supply is redundant and POWER1 is off
[See also] "5.1 Turning the Power On"
2 POWER 2 (SER11)
Lights in green when POWER2 is on. Lights red in the following cases.
・When an error occurs in the POWER2 fan ・When the power supply is redundant and an error occurs on POWER2 ・When the power supply is redundant and POWER2 is off
[See also] "5.1 Turning the Power On"
Page 46
4 PANEL DESCRIPTION
32
3 LCD panel
Displays various information.
4 GENLOCK/CW
Lights in green when the reference signal is locked in GENLOCK or CW. Flashes in orange until locked, lights in orange during stay in sync.
[See also] "6.2.2 Genlock Mode" "6.2.3 CW Mode"
5 GNSS (SER01)
Lights in green when the reference signal is locked in GNSS. Flashes in orange until locked, lights in orange during stay in sync.
[See also] "6.2.4 GNSS mode (SER01)"
6 PTP IN (SER03)
Lights in green when the reference signal is locked in PTP. Flashes in orange until locked, lights in orange during stay in sync.
[See also] "6.2.5 PTP mode (SER03)"
7 INT
Lights in green when the reference signal is INTERNAL.
[See also] "6.2.1 Internal Mode"
8 TIME
Lights in green when the time is successfully acquired from the selected TIME SOURCE. Lights in orange when the time has not been obtained or when the TIME SOURCE has been changed.
When TIME SOURCE is LTC, LTC ST309, VITC, VITC ST309, or NTP, it flashes in orange if the time regularly obtained from TIME SOURCE and the internal time differ by more than 1 second.
9 PTP OUT
Lights in green when the PTP output is operating normally.
[See also] "6.3.5 PTP Signal Output (SER03)"
10 STAY
Lights in orange when in stay-in-sync mode.
[See also] "6.2 Signal Input (Genlock Operation)"
11 ALARM
Lights in red when an alarm occurs.
[See also] "6.5 Alarm Display"
Page 47
4 PANEL DESCRIPTION
33
12 KEYLOCK
Lights in green when the key lock is enabled.
[See also] "6.1.2 Enabling the Key Lock"
13 CONFIG
The CONFIG menu is displayed. Switches the top menu or returns to the higher level menu. It also cancels the settings.
[See also] "6.1.3 Menu Operations"
14 STATUS
The STATUS menu is displayed. Switches the top menu or returns to the higher level menu.
[See also] "6.1.3 Menu Operations" "15 STATUS MENU"
15 KEYLOCK
Holding the key locks the keys or releases the key lock.
[See also] "6.1.2 Enabling the Key Lock"
16 Arrow keys
Used to move the cursor and to set values.
[See also] "6.1.3 Menu Operations"
17 ENTER
Confirms values and enters a lower level menu.
[See also] "6.1.3 Menu Operations"
18 Fan (LP2184)
Cooling fan for the instrument. It needs to be replaced periodically.
[See also] "18.2.2 Front Fan Unit Replacement"
19 USB
USB port. Used to save and load various data.
[See also] "6.1.1 Connecting a USB Memory Device"
Page 48
4 PANEL DESCRIPTION
34

4.2 Rear Panel

An overall and enlarged view of the rear panel is shown below.
Figure 4-3 | Rear panel (overall view)
Figure 4-4 | Rear panel (enlarged view)
1 Serial number label
The serial number is printed on this label.
2 GNSS IN (SER01)
Optional GNSS input connector. It supports GPS, GLONASS, GALILEO, BDS, and QZSS. A separately sold GNSS antenna is available.
[See also] "6.2.4 GNSS mode (SER01)" "14.5 Setting the GNSS (SER01)"
3 L-SYNC
Control port for synchronizing the time of two LT4670 units. A separately sold L-SYNC cable (LC2186) is available.
[See also] "6.6 L-SYNC"
4 CW/1PPS
10 MHz CW or 1PPS output connector.
[See also] "6.3.3 CW/1PPS Signal Output" "11 CW/1PPS CONFIG MENU"
Page 49
4 PANEL DESCRIPTION
35
5 SFP/SFP+ 1, 2 (SER03)
Optional SFP/SFP+ port. To use this port, insert one of the following SFP modules sold separately. ・SFP RJ-45 (LC2141/LC2142) ・SFP+ MULTI-MODE (LC2148) ・SFP+ SINGLE-MODE (LC2149)
[See also] "6.2.5 PTP mode (SER03)" "13 PTP CONFIG MENU (SER03)" "14.6 Configuring the PTP
Settings (SER03)"
6 3G SDI OUT 1, 2 (SER02) 7 3G SDI OUT 3, 4 (SER02)
Optional SDI output connector. It outputs SD, HD, and 3G signals. Adding SER21 allows the connector to output the 4K 3G-Quad signal as well. (Two SER02 units are required.)
[See also] "6.3.4 SDI Signal Output (SER02)" "12 SDI CONFIG MENU (SER02)"
8 LTC/REMOTE
Time code and remote I/O connector. A separately sold LTC cable (LC2185) is available for connection with LT4448.
[See also] "6.4 LTC Signal I/O and Remote Control" "10 LTC CONFIG MENU"
9 ETHERNET/CONTROL
Ethernet port. It supports SNMP, REST-API (future support), HTTP/HTTPS (HTTPS to be supported in the future), and NTP.
10 ANALOG BLACK OUT 1-6
Analog black output connectors. They output HD tri-level sync or NTSC/PAL black burst signals.
[See also] "6.3.1 Analog Black Signal Output" "8 BLACK CONFIG MENU"
11 GENLOCK/CW IN
Loop-through analog sync signal or 10 MHz CW input connectors. For analog sync signals, input HD tri-level sync or NTSC/PAL black burst signals.
[See also] "6.2.2 Genlock Mode" "6.2.3 CW Mode" "7 REFERENCE CONFIG MENU"
12 WCLK
48 kHz word-clock output connector.
[See also] "6.3.2 Audio Signal Output" "9.3 Setting the Word-clock Output"
13 SILENCE
AES/EBU output connector compatible with DARS.
[See also] "6.3.2 Audio Signal Output" "9.2 Setting the Silence Output"
Page 50
4 PANEL DESCRIPTION
36
14 AES/EBU
AES/EBU output connector.
[See also] "6.3.2 Audio Signal Output" "9.1 Setting the AES/EBU Output"
15 Fan (LP2184)
Cooling fan for the instrument. It needs to be replaced periodically.
[See also] "18.2.3 Rear Fan Unit Replacement"
16 POWER2 (SER11)
Optional AC inlet. Adding this option provides power supply redundancy. It needs to be replaced periodically. The LED lights in green or red in conjunction with the POWER2 LED on the front panel.
[See also] "5.1 Turning the Power On" "18.2.1 Power Supply Unit Replacement"
17 POWER1
AC inlet. It needs to be replaced periodically. The LED lights in green or red in conjunction with the POWER1 LED on the front panel.
[See also] "5.1 Turning the Power On" "18.2.1 Power Supply Unit Replacement"
Page 51

5 PREPARATIONS

37
5 PREPARATIONS

5.1 Turning the Power On

5.1.1 Turning the Instrument On and Off

This instrument does not have a power switch. To turn on the power, connect the supplied power cord to POWER1 on the rear panel.
When you turn on the power, the following screens are displayed. During this time, key operations are not possible.
When the following screen is displayed, the startup is complete.
When you turn on the power, POWER 1 on the front panel and the LED on the rear panel light in green. If an error occurs in the fan of the power supply unit, these LEDs turn red. In this case, check the power supply unit where the error occurred and contact your local LEADER agent.
Figure 5-1 | POWER LEDs
Immediately after the power is turned on, the instrument is set to the conditions that it was in when the power was turned off the last time. However, if POWER ON RECALL on the SYSTEM CONFIG menu is set to an option other than OFF, the instrument starts with the specified preset.
[See also] "14.2.4 Power-on Settings"
L E A D E R L T 4 6 7 0
I N I T I A L I Z I N G . . .
L E A D E R L T 4 6 7 0
X T A L W A R M U P . . .
[ S T A T U S ]
|}
I N F O R M A T I O N
Page 52
5 PREPARATIONS
38

5.1.2 Mounting the AC Cord Clamp

An AC cord clamp is included with the instrument to prevent the power cord from being pulled free of the AC inlet. To mount it, follow the procedure below.
1 Connect the power cable.
Ensure that the power cable is inserted within the loop of the AC cord clamp.
2 Adjust the position of the loop portion of the AC cord clamp.
Move the loop portion forward or backward to position it as shown below. To pull the loop portion forward, lift the lever first and then move the loop portion.
Figure 5-2 | Mounting the AC cord clamp 1
3 Adjust the size of the loop portion of the AC cord clamp.
Turn the knob to tighten the loop portion until the knob stops. To loosen the loop portion, lift the lever first and then move the loop portion.
Figure 5-3 | Mounting the AC cord clamp 2
4 Pull the power cord to check that it does not come loose.
Page 53
5 PREPARATIONS
39

5.1.3 Adding the Power Supply Unit (SER11)

Adding the optional power supply unit (SER11) to POWER2 on the rear panel provides power supply redundancy. Even if one of the power supplies fails, the instrument can continue to run with the other power supply, enabling you to build a highly reliable system.
It is possible to add the power supply unit with the power turned on. The following is the procedure for adding the power supply unit to POWER2 with the power of POWER1 turned on as an example.
The power supply unit must be added by LEADER or the designated service personnel. Contact your local LEADER agent.
1 Insert the new power supply unit to POWER2.
Insert the unit until it clicks into place.
Figure 5-4 | Adding the power supply unit 1
2 Tighten the two screws.
Figure 5-5 | Adding the power supply unit 2
3 Connect the power cable to POWER2. 4 Check that the LED on the power supply unit lights in green.
Figure 5-6 | Adding the power supply unit 3
Page 54
5 PREPARATIONS
40
When the power is supplied to POWER1 and POWER2, the POWER LEDs on the front panel light in green. Usually, use the product in this state.
Figure 5-7 | POWER LEDs (during normal operation)
In one of the following situations, either of the POWER LEDs on the front panel turns red and an alarm is displayed.
・An error occurs in the fans of the power supply units. ・An error occurs in the power supply units. ・The power is not supplied to either of the power supply units.
In this case, check the power supply units in which an error occurred and contact your local LEADER agent.
Figure 5-8 | POWER LEDs (when an error occurs)
Page 55
5 PREPARATIONS
41

5.2 Rack Mounting

If you are mounting this instrument on a rack, be sure to provide additional support for the body of the instrument. If you use only the front panel to mount the instrument, the instrument case may deform or fall. This instrument can be mounted on a 19-inch EIA standard rack.
The recommended slide rails are shown in the following table. To mount this instrument on a rack, two slide rails, one for the left side and one for the right side of the instrument, are required.
Table 5-1 | Recommended slide rails
Model Number
Manufacturer
KC-251-16
TAKIGEN MFG CO., LTD.
C203-16
Accuride Japan Co., Ltd.
C-203-16
Settsu Metal Industrial Co., Ltd.
Slide Rail Attachment
Attach slide rails to the instrument using binding head machine screws (M4×10).
Figure 5-9 | Slide rail attachment
Rack Mounting
Insert the instrument into the rack, and then fasten the front panel to the rack. Use M5, 10-32UNF, or 12-24UNC screws.
Figure 5-10 | Rack mounting
Page 56

6 BASIC OPERATION

42
6 BASIC OPERATION

6.1 Operation Basics

6.1.1 Connecting a USB Memory Device

To write and read various types of data, you can use a USB memory device. You can connect and disconnect a USB memory device with the power turned on. Use a USB memory device with USB DEVICE on the SYSTEM CONFIG menu set to ENABLE.
Connecting a USB Memory Device
When you connect a USB memory device, the following message appears. Do not turn the power off or remove the USB memory device while it is being accessed.
Removing the USB Memory Device
When you remove the USB memory device, the following message appears.

6.1.2 Enabling the Key Lock

You can enable the key lock to prevent settings from being changed when keys are pressed by mistake.
Enabling the Key Lock
Hold down the KEYLOCK key until the following message is displayed. This enables the key lock, causing the LED to light in green. While the key lock is enabled, the following message is displayed if you press a key; no key operations are possible.
Releasing the Key Lock
Hold down the KEYLOCK key until the following message is displayed. This releases the key lock, causing the LED to turn off.
1 . U S B D E V I C E
      ■ E N A B L E     □ D I S A B L E
U S B S T O R A G E D E V I C E
I N S E R T
U S B S T O R A G E D E V I C E
E J E C T
K E Y L O C K
P U S H < K E Y L O C K > 3 S E C
K E Y L O C K
U N L O C K S U C C E S S
Page 57
6 BASIC OPERATION
43

6.1.3 Menu Operations

The menu is largely divided into two types, the CONFIG menu and the STATUS menu.
CONFIG Menu
This menu is used to configure this instrument. Press the CONFIG key to display it. When the menu level is 0, press the CONFIG key or the ▶ key to switch from one menu to another in the order below. Press the ◀ key to switch from one menu to another in the reverse order. (This includes option menus).
0 . R E F E R E N C E C O N F I G
|}
u
R E F E R E N C E S O U R C E
CONFIG key / ▶ key ◀ key
0 . B L A C K C O N F I G
|}
u
B L A C K 1              
0 . A U D I O C O N F I G
|}
u
A E S / E B U              
0 . L T C C O N F I G
|}
L T C   O U T P U T  
0 . C W / 1 P P S C O N F I G
|}
O U T P U T  
0 . S D I   C O N F I G
|}
u
S D I 1              
0 . P T P   C O N F I G
|}
u
P T P 1                
0 . S Y S T E M C O N F I G
|}
u
L C D   B A C K L I G H T    
➡➡➡
Page 58
6 BASIC OPERATION
44
Except for some cases, a number is displayed at the upper left of the CONFIG menu. This number indicates the menu level. The larger the number, the deeper the level. To enter a lower level menu, press the ENTER key. To return to a higher level menu, press the CONFIG key. When the menu level is other than 0, hold down the CONFIG key to return to menu level 0.
STATUS Menu
This menu displays the status of this instrument. Press the STATUS key to display it. When you are the top level, press the STATUS key or the ▶ key to switch from one menu to another in the order below. Press the ◀ key to switch from one menu to another in the reverse order.
No levels are indicated on the STATUS menu. As with the CONFIG menu, to enter a lower level menu, press the ENTER key. To return to a higher level menu, press the STATUS key. When you are at a level other than the top level, hold down the STATUS key to return to the top level.
0 . S Y S T E M C O N F I G
|}
N E T W O R K                    
ENTER key CONFIG key
1 . N E T W O R K
Hold down the CONFIG key
u
N E T W O R K S E T U P          
ENTER key STATUS key
2 . N E T W O R K S E T U P
  E N A B L E     □ D I S A B L E
➡➡➡
[ S T A T U S ]
|}
A L A R M  
STATUS key / ▶ key ◀ key
[ S T A T U S ]
|}
I N F O R M A T I O N
[ S T A T U S ]
|}
C O N F I G
[ S T A T U S ]
|}
L O G
[ S T A T U S ]
|}
C O N F I G
ENTER key CONFIG key
[ C O N F I G ]
|}
Hold down the STATUS key
R E F E R E N C E                    
ENTER key CONFIG key
[ R E F E R E N C E S O U R C E ]
|}
I N T E R N A L
➡➡➡
Page 59
6 BASIC OPERATION
45
Specifying Values
To specify a value, select a digit with the ◀ and ▶ keys first and then change it with the ▲ and ▼ keys. Hold down the ▲ or ▼ key to change the value quickly. Except for some cases, value modifications are applied immediately, but the value is not confirmed until you press the ENTER key.
Selecting Items
To select an item, use the ◀ and ▶ keys.
If a menu contains many items, the menu may look like the one shown below. An * is displayed for the currently set item.
If a cursor (_) is displayed, use the ◀ and ▶ keys to move the cursor, and use the ▲ key to turn the item on and the ▼ key to turn it off.
To select a single item from multiple menus, use the ▲ and ▼ key to select a menu and then use the ◀ and ▶ key to select the item.
Confirming and Canceling Settings
To confirm settings, press the ENTER key. After you change settings, press the CONFIG key instead of the ENTER key to return the settings to their original values.
1 . G E N L O C K   T I M I N G   F I N E
  F I N E :       0
1 . L C D   B A C K L I G H T
O N     □ A U T O   O F F   □ O F F
1 . R E F E R E N C E   S O U R C E
|}
G E N L O C K F M T - A U T O
3 . S D I 1 C O M P O N E N T
Y / G       ■ C b / B     ■ C r / R
4 . S D I 1 C O L O R B A R
u
} * 1 0 0
4 . S D I 1   M O N I T O R
}   F L A T   F I E L D   1 0 0 %
4 . S D I 1   S D I
  C H E C K   F I E L D
Page 60
6 BASIC OPERATION
46

6.2 Signal Input (Genlock Operation)

Genlock refers to the act of establishing synchronization using a reference signal. Here, the operation in the following five modes is explained according to the following flow of steps.
Internal mode: Mode in which an internal signal is used as a reference signal
(factory default value)
Genlock mode: Mode in which an external analog sync signal is used as a
reference signal
CW mode: Mode in which an external 10MHz CW signal is used as a
reference signal
GNSS mode (SER01): Mode in which an external GNSS signal is used as a reference
signal
PTP mode (SER03): Mode in which a PTP signal is used as a reference signal
1. Setting
2. Input of a reference signal
3. Lock
4. An error occurs in the reference signal
5. The reference signal is restored
6. Relock
The operation performed when the reference signal is restored differs depending on RECOVERY MODE on the REFERENCE CONFIG menu. When RECOVERY MODE is set to AUTO, relock is automatically performed. When it is set to MANUAL, relock is not performed. Here, the operation performed when the mode is AUTO, in which relock is automatically performed, is explained.

6.2.1 Internal Mode

1. Setting
On the REFERENCE CONFIG menu, set REFERENCE SOURCE to INTERNAL.
Under "STATUS > INFORMATION > REF SRC", "INTERNAL" appears, and INT on the front panel lights in green. Use the instrument in this state.
2 . R E C O V E R Y   M O D E
  A U T O     □ M A N U A L
1 . R E F E R E N C E   S O U R C E
} I N T E R N A L
Page 61
6 BASIC OPERATION
47

6.2.2 Genlock Mode

1. Setting
On the REFERENCE CONFIG menu, set REFERENCE SOURCE to GENLOCK FMT-AUTO or GENLOCK FMT-MANUAL.
When you set it to GENLOCK FMT-MANUAL, set the reference signal format manually. Use GENLOCK FORMAT on the REFERENCE CONFIG menu to select the reference signal format. When you set it to GENLOCK FMT-AUTO, this instrument automatically identifies the reference signal format; this setting is not necessary.
When you set REFERENCE SOURCE to GENLOCK, GENLOCK/CW on the front panel blinks in orange, and under "STATUS > INFORMATION > REF SRC", "INITIALIZE" appears. From now on, this screen is used for explanation.
2. Input of a reference signal
Apply an HD tri-level sync or NTSC/PAL black burst signal to one of the GENLOCK/CW IN connectors on the rear panel. Use either of the following method to apply it.
・Apply to one connector and terminate the other at 75 Ω. ・Apply to one connector, connect the other to another device, and terminate the device at
the end of the chain at 75 Ω.
When you apply the signal, the message changes to "TRACKING" and the reference signal is introduced. Wait in this state.
1 . R E F E R E N C E   S O U R C E
|}
G E N L O C K F M T - A U T O
1 . G E N L O C K N T S C
u
} N T S C   B B
Page 62
6 BASIC OPERATION
48
3. Lock
When the instrument is locked with the reference signal, GENLOCK/CW on the front panel lights in green, and the message changes to "LOCK". Use the instrument in this state.
4. An error occurs in the reference signal
If an error occurs in the reference signal, the frequency that was in use immediately before the error occurred is maintained (stay-in-sync function). When stay-in-sync becomes active, GENLOCK/CW and STAY light in orange, and the message changes to "STAY". In this case, check the reference signal.
5. The reference signal is restored
When the reference signal is restored, STAY on the front panel blinks in orange, and the message changes to "RECOVERY". Wait in this state.
6. Relock
When the instrument is relocked with the reference signal, GENLOCK/CW on the front panel lights in green and STAY turns off. In addition, the message changes to "LOCK". Use the instrument in this state.
Page 63
6 BASIC OPERATION
49

6.2.3 CW Mode

1. Setting
On the REFERENCE CONFIG menu, set REFERENCE SOURCE to 10MHz CW.
When you set REFERENCE SOURCE to 10MHz CW, GENLOCK/CW on the front panel blinks in orange, and under "STATUS > INFORMATION > REF SRC", "INITIALIZE" appears. From now on, this screen is used for explanation.
2. Input of a reference signal
Apply a 10MHz CW signal to one of the GENLOCK/CW IN connectors on the rear panel. Use either of the following methods to apply it.
・Apply to one connector and terminate the other at 75 Ω. ・Apply to one connector, connect the other to another device, and terminate the device at
the end of the chain at 75 Ω.
When you apply the signal, the message changes to "TRACKING" and the reference signal is introduced. Wait in this state.
3. Lock
When the instrument is locked with the reference signal, GENLOCK/CW on the front panel lights in green, and the message changes to "LOCK". Use the instrument in this state.
1 . R E F E R E N C E   S O U R C E
|}
1 0 M H z C W
Page 64
6 BASIC OPERATION
50
4. An error occurs in the reference signal
If an error occurs in the reference signal, the frequency that was in use immediately before the error occurred is maintained (stay-in-sync function). When stay-in-sync becomes active, GENLOCK/CW and STAY light in orange, and the message changes to "STAY". In this case, check the reference signal.
5. The reference signal is restored
When the reference signal is restored, STAY on the front panel blinks in orange, and the message changes to "RECOVERY". Wait in this state.
6. Relock
When the instrument is relocked with the reference signal, GENLOCK/CW on the front panel lights in green and STAY turns off. In addition, the message changes to "LOCK". Use the instrument in this state.
Page 65
6 BASIC OPERATION
51

6.2.4 GNSS mode (SER01)

1. Setting
On the REFERENCE CONFIG menu, set REFERENCE SOURCE to GNSS.
When you set REFERENCE SOURCE to GNSS, GNSS on the front panel blinks in orange, and under "STATUS > INFORMATION > REF SRC", "GNSS No. Fix" appears. From now on, this screen is used for explanation.
2. Input of a reference signal
Apply a GNSS signal to the GNSS IN connector on the rear panel.
When you apply the signal, an "*" is attached after "GNSS". In addition, the message changes to "ADJUST FREQ TO GNSS" > "ADJUST PHASE TO GNSS" > "TRACKING" in this order, and the reference signal is introduced. Wait in this state.
3. Lock
When the instrument is locked with the reference signal, GNSS on the front panel lights in green, and the message changes to "LOCK". Use the instrument in this state.
1 . R E F E R E N C E   S O U R C E
|}
G N S S
Page 66
6 BASIC OPERATION
52
4. An error occurs in the reference signal
If an error occurs in the reference signal, the frequency that was in use immediately before the error occurred is maintained (stay-in-sync function). When stay-in-sync becomes active, GNSS and STAY light in orange, and the message changes to "STAY". In this case, check the reference signal.
5. The reference signal is restored
When the reference signal is restored, STAY on the front panel blinks in orange, and the message changes to "RECOVERY". Wait in this state.
6. Relock
When the instrument is relocked with the reference signal, GNSS on the front panel lights in green and STAY turns off. In addition, the message changes to "LOCK". Use the instrument in this state.
Page 67
6 BASIC OPERATION
53

6.2.5 PTP mode (SER03)

1. Setting
In the REFERENCE CONFIG menu, set REFERENCE SOURCE to PTP1, PTP2, or PTP1/2. In the following example, it is set to PTP1.
When you set REFERENCE SOURCE to PTP1 or PTP2, PTP IN on the front panel blinks in orange, and under "STATUS > INFORMATION > REF SRC", "PTP FOLLOWER AGING" > "PTP LEADER NOT FOUND" appears. From now on, this screen is used for explanation.
2. Input of a reference signal
Apply PTP signals to PTP connectors on the rear panel. Mount and use one of the SFP and SFP+ modules listed below, which are sold separately. You can connect and disconnect the SFP and SFP+ modules with the power turned on.
・SFP RJ-45 (LC2141/LC2142) ・SFP+ MULTI-MODE (LC2148) ・SFP+ SINGLE-MODE (LC2149)
When you apply the signal, the message changes to "PTP ADJUST FREQ" > "PTP ADJUST PHASE" > "TRACKING" in this order, and the reference signal is introduced. Wait in this state.
1 . R E F E R E N C E   S O U R C E
|}
P T P 1
Page 68
6 BASIC OPERATION
54
3. Lock
When the instrument is locked with the reference signal, PTP IN on the front panel lights in green, and the message changes to "LOCK". Use the instrument in this state.
When REFERENCE SOURCE is set to PTP1/2, the instrument automatically selects the reference signal. "LOCK" is displayed for the reference signal, and "PASSIVE" is displayed for the other signal.
4. An error occurs in the reference signal
If an error occurs in the reference signal, the frequency that was in use immediately before the error occurred is maintained (stay-in-sync function). When stay-in-sync becomes active, PTP IN and STAY light in orange, and the message changes to "STAY". In this case, check the reference signal.
5. The reference signal is restored
When the reference signal is restored, STAY on the front panel blinks in orange, and the message changes to "PTP ADJUST FREQ" > "PTP ADJUST PHASE" > "RECOVERY" in this order. Wait in this state.
6. Relock
When the instrument is relocked with the reference signal, PTP IN on the front panel lights in green and STAY turns off. In addition, the message changes to "LOCK". Use the instrument in this state.
Page 69
6 BASIC OPERATION
55
When REFERENCE SOURCE is set to PTP1/2, the PTP IN LED on the front panel is displayed as shown below according to the combination of the PTP1 state and the PTP2 state.
Table 6-1 | PTP IN LED
PTP1
・LOCK ・PASSIVE
・STAY ・PTP ADJUST FREQ (when restored) ・PTP ADJUST PHASE (when restored) ・RECOVERY
・PTP FOLLOWER AGING ・PTP LEADER NOT FOUND ・PTP ADJUST FREQ (when locked) ・PTP ADJUST PHASE (when locked) ・TRACKING
PTP2
・LOCK ・PASSIVE
Lit in green
Lit in orange
Blinking orange
・STAY ・PTP ADJUST FREQ (when restored) ・PTP ADJUST PHASE (when restored) ・RECOVERY
Lit in orange
Lit in orange
Blinking orange
・PTP FOLLOWER AGING ・PTP LEADER NOT FOUND ・PTP ADJUST FREQ (when locked) ・PTP ADJUST PHASE (when locked) ・TRACKING
Blinking orange
Blinking orange
Blinking orange
Page 70
6 BASIC OPERATION
56

6.3 SDI Signal Output

6.3.1 Analog Black Signal Output

Six analog black signals synchronized with the reference signal are output from ANALOG BLACK OUT connectors 1 to 6 on the rear panel. You can set the analog black signals on the BLACK CONFIG menu.
[See also] "8 BLACK CONFIG MENU"

6.3.2 Audio Signal Output

An AES/EBU signal synchronized with the reference signal is output from the AES/EBU connector on the rear panel; a silence (DARS) signal synchronized with the reference signal is output from the SILENCE connector; and a word-clock signal synchronized with the reference signal is output from the WCLK connector. Use DIN cables. You can set the audio signals on the AUDIO CONFIG menu.
[See also] "9 AUDIO CONFIG MENU"

6.3.3 CW/1PPS Signal Output

A 10MHz CW signal or 1PPS signal synchronized with the reference signal is output from the CW/1PPS connector on the rear panel.
You can select the output signal type with CW/1PPS OUTPUT on the CW/1PPS CONFIG menu.
[See also] "11 CW/1PPS CONFIG MENU"

6.3.4 SDI Signal Output (SER02)

Four SDI signals synchronized with the reference signal are output from 3G SDI OUT connectors 1 to 4 on the rear panel. You can set the SDI signal on the SDI CONFIG menu.
[See also] "12 SDI CONFIG MENU (SER02)"
1 . C W / 1 P P S O U T P U T
      ■ C W             □ 1 P P S    
Page 71
6 BASIC OPERATION
57

6.3.5 PTP Signal Output (SER03)

Two PTP signals synchronized with the reference signal are output from PTP connectors 1 and 2 on the rear panel.
Mount and use one of the SFP and SFP+ modules listed below, which are sold separately. You can connect and disconnect the SFP and SFP+ modules with the power turned on.
・SFP RJ-45 (LC2141/LC2142) ・SFP+ MULTI-MODE (LC2148) ・SFP+ SINGLE-MODE (LC2149)
To output the PTP signal requires setting the PTP Leader. In the PTP CONFIG menu, set PTP1 MODE or PTP2 MODE to ENABLE LEADER.
[See also] "13.1 PTP Leader and PTP Follower"
When you set PTP1 MODE or PTP2 MODE to ENABLE LEADER, PTP OUT on the front panel blinks in orange, and the "STATUS > INFORMATION > PTP OUTPUT" message is switched to "TIME MEASURING" > "TIME SETTING" > "LISTENING" > "PRELEADER" in this order and displayed. During this time, the PTP signal is not output correctly. Wait in this state.
When the PTP output becomes normal, PTP OUT on the front panel lights in green, and the message changes to "LEADER". Use the instrument in this state.
2 . P T P 1   M O D E
} * E N A B L E   L E A D E R        
Page 72
6 BASIC OPERATION
58
Note that when the BMCA function causes this instrument to enter the passive state, PTP OUT on the front panel lights in orange and the message changes to "PASSIVE".
When PTP1 and PTP2 are both leaders, the PTP OUT LED on the front panel is displayed as shown below according to the combination of the PTP1 state and the PTP2 state.
Table 6-2 | PTP OUT LED
PTP1
・LEADER
・PASSIVE
・TIME MEASURING ・TIME SETTING ・LISTENING ・PRELEADER
PTP2
・LEADER
Lit in green
Lit in orange
Blinking orange
・PASSIVE
Lit in orange
Lit in orange
Blinking orange
・TIME MEASURING ・TIME SETTING ・LISTENING ・PRELEADER
Blinking orange
Blinking orange
Blinking orange
Page 73
6 BASIC OPERATION
59

6.4 LTC Signal I/O and Remote Control

The LTC/REMOTE connector on the rear panel is used to input an LTC signal (1 input), output three LTC signals (3 outputs), and perform remote control (alarm output, preset recall).
Figure 6-1 | LTC/REMOTE
Table 6-3 | Pinout
Pin No.
I/O
Pin Name
1
I
LTC+ 2 -
GND 3 O
LTC1+ 4 O
LTC2+ 5 O
LTC3+ 6 -
GND 7 O
ALARM1 8 O
ALARM2 9 -
RESERVED
10
I
LTC-
11
-
GND
12
O
LTC1-
13
O
LTC2-
14
O
LTC3-
15
-
GND
16
-
RESERVED
17
-
RESERVED
18
-
OPEN
19
-
SHIELD GND
20
I
PRESET1
21
I
PRESET2
22
I
PRESET3
23
I
PRESET4
24
-
GND
25
-
RESERVED
26
-
SHIELD GND
Page 74
6 BASIC OPERATION
60
LTC Signal Input (1 input)
It is possible to insert time codes received through LTC into the black output, AES/EBU output, and SDI output (SER02) and output from LTC1 to LTC3.
LTC Signal Output (3 Outputs)
Time codes synchronized with the reference time are output from LTC1 to LTC3. You can select the time code type with TIME SOURCE on the REFERENCE CONFIG menu.
Alarm Output
When any of the alarms set to ENABLE with ALARM OPTION on the SYSTEM CONFIG menu occurs, the alarm is output from ALARM1 or ALARM2 at the 5V CMOS level. (The polarity can be inverted.)
[See also] "14.7.2 Turning the Alarm Output On and Off"
Table 6-4 | Alarm output
Alarm
Alarm Condition
UNIT POWER1
When an error occurs in POWER1 When power supply redundancy is provided and the power is not supplied to POWER1 (SER11)
UNIT POWER2
When an error occurs in POWER2 (SER11) When power supply redundancy is provided and the power is not supplied to POWER2 (SER11)
FAN POWER1
When an error occurs in the POWER1 fan
FAN POWER2
When an error occurs in the POWER2 fan (SER11)
FAN FRONT
When an error occurs in the front fan unit
FAN REAR
When an error occurs in the rear fan unit
REFERENCE NO SIGNAL
When the set reference signal is not received
REFERENCE STAY
When an error occurs in the reference signal, and stay-in-sync is in operation.
GNSS ANTENNA
When ANTENNA POWER on the SYSTEM CONFIG menu is set to 3.3V or 5V and a short circuit occurs (SER01)
Page 75
6 BASIC OPERATION
61
Recalling Presets
You can use PRESET1 to PRESET4 to recall presets 0 to 9. Apply L according to the table below.
Table 6-5 | Recalling presets
Preset Numbers
23p
22p
21p
20p
PRESET4
PRESET3
PRESET2
PRESET1
0 H H H L 1 H H L H 2 H H L L 3 H L H H 4 H L H L 5 H L L H 6 H L L L 7 L H H H 8 L H H L 9 L H L
H

6.5 Alarm Display

If an alarm occurs, the ALARM indicator on the front panel lights in red.
To check the description of the alarm, select ALARM from the STATUS menu. If multiple alarms have occurred, you can use the ◀ and ▶ keys to switch from the description of one alarm to that of another.
For information about the types of alarms displayed, see "15.1 ALARM Menu".
Figure 6-2 | Alarm display
Page 76
6 BASIC OPERATION
62

6.6 L-SYNC

L-SYNC refers to a function whereby, in a redundant system, the primary and backup instruments, synchronized with the same analog sync signal, can be synchronized in time with each other. The following explains how to use it, considering the following system as an example.
Figure 6-3 | L-SYNC
1. Connect the L-SYNC connectors of the LT4670s with an L-SYNC cable.
For the L-SYNC cable, use the LC2186 (sold separately).
2. Apply an analog sync signal to one of the GENLOCK/CW IN connectors of each of the LT4670 (primary) and the LT4670 (backup).
Apply the same analog sync signal to the primary and backup instruments. Terminate the unused connector of each of the primary and backup instruments at 75 Ω. L-SYNC is not supported when the analog sync signal format is 23.98 Hz.
Page 77
6 BASIC OPERATION
63
3. On each of the LT4670 (primary) and the LT4670 (backup), set REFERENCE SOURCE.
You can set REFERENCE SOURCE with "REFERENCE CONFIG > REFERENCE SOURCE". Set it to "GENLOCK FMT-AUTO" or "GENLOCK FMT-MANUAL".
When the operation is performed properly, GENLOCK/CW on the front panel lights in green.
4. On the LT4670 (primary), set TIME SOURCE.
You can set TIME SOURCE with "REFERENCE CONFIG > TIME SOURCE". Select one of the options. The TIME SOURCE setting of the LT4670 (backup) is fixed to INTERNAL by setting L-SYNC SETUP to BACKUP in step 5.
When the operation is performed properly, TIME on the front panel lights in green.
5. On each of the LT4670 (primary) and LT4670 (backup), set L-SYNC SETUP.
You can set L-SYNC SETUP with "SYSTEM CONFIG > TIME MANAGEMENT > L-SYNC SETUP".
For the LT4670 (primary), set it to "PRIMARY".
For the LT4670 (backup), set it to "BACKUP".
Subsequently, the time of LT4670 (backup) will be the same as the time set by the LT4670 (primary). When the time of the LT4670 (primary) changes, the time of the LT4670 (backup) will also change accordingly.
1 . R E F E R E N C E   S O U R C E
|}
G E N L O C K F M T - A U T O
1 . T I M E S O U R C E
} * I N T E R N A L
2 . L - S Y N C S E T U P
} * P R I M A R Y
2 . L - S Y N C S E T U P
} B A C K U P
Page 78

7 REFERENCE CONFIG MENU

64
7 REFERENCE CONFIG MENU
The REFERENCE CONFIG menu is used to specify settings related to the reference signal and genlock operation. To display the REFERENCE CONFIG menu, press CONFIG several times until the following menu appears.

7.1 Selecting the Reference Signal

To select the reference signal, follow the procedure below.
Procedure REFERENCE CONFIG > REFERENCE SOURCE
Parameters INTERNAL: The internal reference signal is used.
GENLOCK FMT-AUTO: An external reference signal received through GENLOCK/CW IN
on the rear panel is used. The format is automatically identified.
GENLOCK FMT-MANUAL: An external reference signal received through GENLOCK/CW IN
on the rear panel is used. The format should be set manually.
10MHz CW: An external reference signal received through GENLOCK/CW IN
on the rear panel is used.
GNSS (SER01): An external reference signal received through GNSS IN on the
rear panel is used.
PTP1 (SER03): An external reference signal received through PTP on the rear
panel is used. PTP1 operates as a PTP follower.
PTP2 (SER03): An external reference signal received through PTP on the rear
panel is used. PTP2 operates as a PTP follower.
PTP1/2 (SER03): An external reference signal received through PTP on the rear
panel is used. Both PTP1 and PTP2 operate as PTP followers, and the instrument automatically selects the reference signal. You can check the selection result using "STATUS > INFORMATION > REF SRC". "LOCK" is displayed for the reference signal, and "PASSIVE" is displayed for the other signal.
Initial value INTERNAL
0 . R E F E R E N C E C O N F I G
|}
u
G E N L O C K S O U R C E
1 . R E F E R E N C E   S O U R C E
} I N T E R N A L
Page 79
7 REFERENCE CONFIG MENU
65

7.2 Selecting the Genlock Format

When REFERENCE SOURCE is set to GENLOCK FMT-MANUAL, to select the genlock format, follow the procedure below. To select an item, use the ▲, ▼, ◀, and ▶ keys.
The genlock formats are expressed in terms of the total number of lines, not the number of effective lines. REF represents the field reference pulse, and ID represents the field ID.
Procedure REFERENCE CONFIG > GENLOCK FORMAT
Parameters NTSC: NTSC BB / NTSC BB+REF / NTSC BB+ID / NTSC BB+REF+ID
PAL: PAL BB / PAL BB+REF COMPONENT: 525/59.94I / 525/59.94P / 625/50I / 625/50P 1125:HD: 1125/60I / 1125/59.94I / 1125/50I / 1125/30P / 1125/29.97P /
1125/25P / 1125/24P / 1125/23.98P / 1125/24PsF / 1125/23.98PsF / 1125/60P / 1125/59.94P / 1125/50P
750:HD: 750/60P / 750/59.94P / 750/50P / 750/30P / 750/29.97P /
750/25P / 750/24P / 750/23.98P
Initial value NTSC BB (when FORMAT SETTING on the SYSTEM CONFIG menu is set to NTSC)
PAL BB (when FORMAT SETTING on the SYSTEM CONFIG menu is set to PAL)
1 . G E N L O C K N T S C
u
} * N T S C   B B
1 . G E N L O C K P A L
}   P A L   B B
1 . G E N L O C K C O M P O N E N T
}   5 2 5 / 5 9 . 9 4 I
1 . G E N L O C K 1 1 2 5 : H D
}   1 1 2 5 / 6 0 I
1 . G E N L O C K 7 5 0 : H D
}   7 5 0 / 6 0 P
Page 80
7 REFERENCE CONFIG MENU
66

7.3 Setting the Genlock Timing

When REFERENCE SOURCE is set to GENLOCK, you can collectively adjust the timing of the output signals (ANALOG BLACK OUT, 3G SDI OUT, AES/EBU, SILENCE, WCLK, and LTC) relative to the reference signal. (You can also adjust them individually.) One step is approximately 0.5 ns, which covers a 1-dot cycle.
Procedure REFERENCE CONFIG > GENLOCK TIMING FINE
Parameters ±100
Initial value 0

7.4 Selecting the Satellite (SER01)

When REFERENCE SOURCE is set to GNSS, to select the satellite, follow the procedure below. Leave this set to ALL under standard operating circumstances.
Procedure REFERENCE CONFIG > GNSS SATELLITE
Parameters ALL / GPS / GLONASS / GALILEO / BDS / GPS+QZSS
Initial value ALL
1 . G E N L O C K   T I M I N G   F I N E
  F I N E :       0
1 . G N S S S A T E L L I T E
} A L L
Page 81
7 REFERENCE CONFIG MENU
67

7.5 Setting the Recovery Operation

Under RECOVERY/TRACKING on the REFERENCE CONFIG menu, you can set the recovery operation that takes place when the reference signal is lost during genlock operation. This menu appears when REFERENCE SOURCE is set to an option other than INTERNAL.

7.5.1 Selecting the Recovery Mode

To select the operation to perform when the reference signal recovers after it is lost during genlock operation, follow the procedure below.
Procedure REFERENCE CONFIG > RECOVERY/TRACKING > MODE
Parameters AUTO: Relocks onto the reference signal.
MANUAL: Stay-in-sync operation is held. Use REFERENCE READJUST to
relock.
Initial value AUTO

7.5.2 Selecting the Relock Speed (Auto)

When RECOVERY MODE is set to AUTO, to select the relock speed, follow the procedure below. From the time this instrument is started until the time set with IMMEDIATE MODE TIME elapses, the instrument operates with IMMEDIATE regardless of the selection made here. (This does not apply when REFERENCE SOURCE is set to GNSS.)
Procedure REFERENCE CONFIG > RECOVERY/TRACKING > AUTO SETTING
Parameters IMMEDIATE: Immediately relocks onto the reference signal. This cannot be
selected when REFERENCE SOURCE is set to GNSS. FAST: Quickly relocks onto the reference signal. SLOW: Slowly relocks onto the reference signal.
Initial value FAST
0 . R E F E R E N C E C O N F I G
|}
R E C O V E R Y / T R A C K I N G
2 . R E C O V E R Y   M O D E
  A U T O     □ M A N U A L
2 . A U T O   S E T T I N G
|}
F A S T
Page 82
7 REFERENCE CONFIG MENU
68

7.5.3 Selecting the Relock Speed (Manual)

When RECOVERY MODE is set to MANUAL, to select the relock speed, follow the procedure below. From the time this instrument is started until the time set with IMMEDIATE MODE TIME elapses, the instrument operates with IMMEDIATE regardless of the selection made here.
Procedure REFERENCE CONFIG > RECOVERY/TRACKING > MANUAL SETTING
Parameters IMMEDIATE: Immediately relocks onto the reference signal.
FAST: Quickly relocks onto the reference signal. SLOW: Slowly relocks onto the reference signal.
Initial value IMMEDIATE

7.5.4 Power-on Settings

From the time this instrument is started until the set time elapses, the instrument operates with IMMEDIATE regardless of the selection made with AUTO SETTING or MANUAL SETTING. To set the time for which the instrument operates with IMMEDIATE, follow the procedure below.
Procedure REFERENCE CONFIG > RECOVERY/TRACKING > IMMEDIATE MODE TIME
Parameters OFF / 5 - 30 [min]
Initial value 5 [min]

7.6 Setting the Relock

When REFERENCE SOURCE is set to an option other than INTERNAL, relock onto the reference signal, select OK by following the procedure below.
Procedure REFERENCE CONFIG > REFERENCE READJUST
2 . M A N U A L   S E T T I N G
|}
I M M E D I A T E
2 . I M M E D I A T E M O D E T I M E
B O O T - U P : 5 m i n
1 . R E F E R E N C E R E A D J U S T
      □ O K             ■ C A N C E L
Page 83
7 REFERENCE CONFIG MENU
69

7.7 Selecting the Time Source

To select the time source to use with this instrument, follow the procedure below. The date and time selected here is used for the log and the time code and for storing to a USB memory device, for example.
Procedure REFERENCE CONFIG > TIME SOURCE
Parameters INTERNAL / LTC / LTC ST309 / VITC / VITC ST309 / NTP /
GNSS (SER01) / PTP1 (SER03) / PTP2 (SER03) / PTP1/2 (SER03)
Initial value INTERNAL
The selectable TIME SOURCEs depend on the setting of REFERENCE SOURCE as shown below.
Table 7-1 | TIME SOURCE
REFERENCE SOURCE
TIME SOURCE
Description
INTERNAL
INTERNAL
The internal clock is used.
LTC (*1)
At power-on and when REFERENCE SOURCE or TIME SOURCE is changed, the hours, minutes, and seconds are loaded from TIME SOURCE once and are set in the internal clock. The internal year, month, and day are used.
LTC ST309 (*1)
At power-on and when REFERENCE SOURCE or TIME SOURCE is changed, the year, month, and day, as well as the hours, minutes, and seconds, are loaded from TIME SOURCE and are set in the internal clock.
NTP (*2)
GNSS (SER01)
PTP1 (SER03)
PTP2 (SER03)
GENLOCK FMT-AUTO GENLOCK FMT-MANUAL (*3)
INTERNAL
The internal clock is used. The internal clock is counted up in sync with REFERENCE SOURCE.
LTC (*1)
At power-on and when REFERENCE SOURCE or TIME SOURCE is changed, the hours, minutes, and seconds are loaded from TIME SOURCE once and are set in the internal clock. The internal year, month, and day are used. The internal clock is counted up in sync with REFERENCE SOURCE. (*4)
VITC (*1)
LTC ST309 (*1)
At power-on and when REFERENCE SOURCE or TIME SOURCE is changed, the year, month, and day, as well as the hours, minutes, and seconds, are loaded from TIME SOURCE and are set in the internal clock. The internal clock is counted up in sync with REFERENCE SOURCE. (*4)
VITC ST309 (*1)
NTP (*2)
GNSS (SER01)
PTP1 (SER03)
PTP2 (SER03)
1 . T I M E S O U R C E
} I N T E R N A L
Page 84
7 REFERENCE CONFIG MENU
70
REFERENCE SOURCE
TIME SOURCE
Time information
10MHz CW
INTERNAL
The internal clock is used. The internal clock is counted up in sync with REFERENCE SOURCE.
LTC (*1)
At power-on and when REFERENCE SOURCE or TIME SOURCE is changed, the hours, minutes, and seconds are loaded from TIME SOURCE once and are set in the internal clock. The internal year, month, and day are used. The internal clock is counted up in sync with REFERENCE SOURCE. (*4)
LTC ST309 (*1)
At power-on and when REFERENCE SOURCE or TIME SOURCE is changed, the year, month, and day, as well as the hours, minutes, and seconds, are loaded from TIME SOURCE and are set in the internal clock. The internal clock is counted up in sync with REFERENCE SOURCE. (*4)
NTP (*2)
GNSS (SER01)
PTP1 (SER03)
PTP2 (SER03)
GNSS (SER01)
GNSS
The time acquired from the satellite is used.
PTP1 (SER03)
PTP1
The time received by the PTP follower is used.
PTP2 (SER03)
PTP2
The time received by the PTP follower is used.
PTP1/2 (SER03)
PTP1/2
The time received by the PTP follower is used. The instrument automatically selects the time source, and you can check the selection result using "STATUS > INFORMATION > REF SRC". "LOCK" is displayed for the time source, and "PASSIVE" is displayed for the other signal.
*1 The input and output frame counts do not match. *2 Available when both NETWORK SETUP and NTP SETUP are set to ENABLE in the SYSTEM CONFIG
menu.
*3 TIME SOURCE is fixed to INTERNAL when L-SYNC SETUP in the SYSTEM CONFIG menu is set to
BACKUP.
*4 If REFERENCE SOURCE differs from TIME SOURCE, the internal clock will shift from the TIME SOURCE
time.

7.8 Loading the Date and Time

When REFERENCE SOURCE is locked and the time can be acquired from TIME SOURCE normally, load the time selected with TIME SOURCE, select OK by following the procedure below.
Procedure REFERENCE CONFIG > TIME READJUST
1 . T I M E R E A D J U S T
      □ O K             ■ C A N C E L
Page 85

8 BLACK CONFIG MENU

71
8 BLACK CONFIG MENU
The BLACK CONFIG menu is used to specify settings related to the black output. To display the REFERENCE CONFIG menu, press CONFIG several times until the following menu appears.
On the BLACK CONFIG menu, you can specify settings for BLACK1 to BLACK6 individually. The procedure below is for BLACK1, but the same procedure can also be applied to BLACK2 to BLACK6.

8.1 Selecting the Black Format

To select the black format, follow the procedure below. To select an item, use the ▲, ▼, ◀, and ▶ keys.
The black formats are expressed in terms of the total number of lines, not the number of effective lines. REF and R represent the field reference pulse, ID represents the field ID, and S represents setup.
Procedure BLACK CONFIG > BLACK1 > FORMAT
Parameters NTSC: NTSC BB / NTSC BB+REF / NTSC BB+ID / NTSC BB+REF+ID /
NTSC BB+SETUP / NTSC BB+S+REF / NTSC BB+S+ID / NTSC
BB+S+R+ID PAL: PAL BB / PAL BB+REF COMPONENT: 525/59.94I / 525/59.94P / 625/50I / 625/50P 1125:HD: 1125/60I / 1125/59.94I / 1125/50I / 1125/30P / 1125/29.97P /
1125/25P / 1125/24P / 1125/23.98P / 1125/24PsF /
1125/23.98PsF / 1125/60P / 1125/59.94P / 1125/50P 750:HD: 750/60P / 750/59.94P / 750/50P / 750/30P / 750/29.97P /
750/25P / 750/24P / 750/23.98P
0 . B L A C K C O N F I G
|}
u
B L A C K 1            
2 . B L A C K 1 N T S C
u
} * N T S C   B B
2 . B L A C K 1 P A L
}   P A L   B B
2 . B L A C K 1 C O M P O N E N T
}   5 2 5 / 5 9 . 9 4 I
2 . B L A C K 1 1 1 2 5 : H D
}   1 1 2 5 / 6 0 I
2 . B L A C K 1 7 5 0 : H D
}   7 5 0 / 6 0 P
Page 86
8 BLACK CONFIG MENU
72
Initial value NTSC BB (when FORMAT SETTING on the SYSTEM CONFIG menu is set to NTSC)
PAL BB (when FORMAT SETTING on the SYSTEM CONFIG menu is set to PAL)

8.2 Configuring Timing Data

Under TIMING on the BLACK1 menu, you can adjust the timing of the black output relative to the reference signal.

8.2.1 Adjusting the Timing (Frame)

When the black format is set to NTSC or PAL, to adjust the timing of the black output relative to the reference signal at the frame level, follow the procedure below.
Procedure BLACK CONFIG > BLACK1 > TIMING > FRAME
Parameters ±5 [FRAME] (when FORMAT is set to NTSC)
±2 [FRAME] (when FORMAT is set to PAL)
Initial value 0 [FRAME]

8.2.2 Adjusting the Timing (Line)

To adjust the timing of the black output relative to the reference signal at the line level, follow the procedure below. The variable range varies depending on the black format.
Procedure BLACK CONFIG > BLACK1 > TIMING > VERTICAL
Parameters ±1124 [LINE]
Initial value 0 [LINE]
1 . B L A C K 1
T I M I N G  
3 . B L A C K 1 T I M I N G   F
    0   F R A M E
3 . B L A C K 1 T I M I N G   V
          0   L I N E
Page 87
8 BLACK CONFIG MENU
73

8.2.3 Adjusting the Timing (Dot)

To adjust the timing of the black output relative to the reference signal at the dot level, follow the procedure below. At the lower right of the screen, the value in dots converted to time is displayed. The variable range varies depending on the black format.
Procedure BLACK CONFIG > BLACK1 > TIMING > HORIZONTAL
Parameters ±4124 [DOT]
Initial value 0 [DOT]

8.3 Setting the Time Code

Under VITC SETTING on the BLACK1 menu, you can specify settings for the time code to insert into the black output. This menu appears when the black format is set to NTSC or PAL.

8.3.1 Turning Time Code Insertion On and Off

To turn time code insertion on and off, follow the procedure below. The time code selected with TIME SOURCE on the REFERENCE CONFIG menu is used.
Procedure BLACK CONFIG > BLACK1 > VITC SETTING > VITC
Parameters ON / OFF
Initial value OFF
3 . B L A C K 1 T I M I N G   H
        0   D O T       0 . 0 0 0 0 μ s
1 . B L A C K 1
V I T C   S E T T I N G            
3 . B L A C K 1   V I T C
      □ O N             ■ O F F
Page 88
8 BLACK CONFIG MENU
74

8.3.2 Setting Dropped Frames

To select the dropped frame setting, follow the procedure below. This setting is valid when the frame frequency of the black output is set to 59.94 or 29.97.
Procedure BLACK CONFIG > BLACK1 > VITC SETTING > DROP FRAME
Parameters ON: Dropped frame time code is used.
OFF: Non-dropped frame time code is used.
Initial value ON

8.3.3 Setting the Time Code Superimposition Line

To set the line number on which the time code will be superimposed, follow the procedure below. Set the line number for field 1. The line number in field 2 is displayed in parentheses.
There are some lines that cannot be selected as shown below. ・When the black format is NTSC and REF is included: Line 10 cannot be selected ・When the black format is NTSC and ID is included: Line 15 cannot be selected ・When the black format is PAL BB+REF: Line 7 cannot be selected
Procedure BLACK CONFIG > BLACK1 > VITC SETTING > LINE NUMBER
Parameters 10 - 20 [LINE] (when FORMAT is set to NTSC)
6 - 22 [LINE] (when FORMAT is set to PAL)
Initial value 14 (when FORMAT is set to NTSC)
19 (when FORMAT is set to PAL)
3 . B L A C K 1 D R O P   F R A M E
      ■ O N             □ O F F
3 . B L A C K 1 L I N E N U M B E R
1 4 ( 2 7 7 ) L I N E
Page 89
8 BLACK CONFIG MENU
75

8.4 Setting the Black Output

Under OUTPUT SETTING on the BLACK1 menu, you can specify settings for the black output.

8.4.1 Turning the Black Output On and Off

To turn the black output on and off, follow the procedure below.
Procedure BLACK CONFIG > BLACK1 > OUTPUT SETTING > OUTPUT
Parameters ENABLE / DISABLE
Initial value ENABLE

8.4.2 Turning BMCA Linkage On and Off (SER03)

If you set ENABLE in the procedure below, the black output is stopped in linkage with BMCA of the selected PTP. Once the black output is stopped, this menu and the OUTPUT menu are both changed to DISABLE. To enable the black output again, set the OUTPUT menu to ENABLE.
Procedure BLACK CONFIG > BLACK1 > OUTPUT SETTING >
LINKED TO PTP1 BMCA / LINKED TO PTP2 BMCA
Parameters ENABLE / DISABLE
Initial value DISABLE
1 . B L A C K 1
O U T P U T S E T T I N G      
3 . B L A C K 1   O U T P U T
      ■ E N A B L E     □ D I S A B L E
3 . B L A C K 1   L I N K E D T O P T P 1
      □ E N A B L E     ■ D I S A B L E
Page 90
8 BLACK CONFIG MENU
76

8.5 Settings Shared by Black Outputs

To specify the settings for BLACK2 to be the same as those for BLACK1, select ON by following the procedure below. In this case, you cannot specify the settings for BLACK2. Similarly, you can also specify the settings for BLACK3 to BLACK6 to be the same as those for BLACK1.
Procedure BLACK CONFIG > BLACK2 > EQUAL TO BLACK1
Parameters ON / OFF
Initial value OFF
2 . B L A C K 2   E Q U A L   T O   B L A C K 1
      □ O N             ■ O F F
Page 91

9 AUDIO CONFIG MENU

77
9 AUDIO CONFIG MENU
The AUDIO CONFIG menu is used to specify settings related to the AES/EBU output, silence output, and word-clock output. To display the AUDIO CONFIG menu, press CONFIG several times until the following menu appears.

9.1 Setting the AES/EBU Output

Under AES/EBU on the AUDIO CONFIG menu, you can specify settings for the AES/EBU output.

9.1.1 Selecting the Frequency

To select the frequency of the selected channel, follow the procedure below.
Procedure AUDIO CONFIG > AES/EBU > SETTING > CH1 / CH2 > FREQ
Parameters SILENCE / 400Hz / 800Hz / 1kHz
Initial value 1kHz

9.1.2 Setting the Level

To set the level of the selected channel, follow the procedure below.
Procedure AUDIO CONFIG > AES/EBU > SETTING > CH1 / CH2 > LEVEL
Parameters
-60 - 0 [dBFS]
Initial value
-20 [dBFS]
0 . A U D I O C O N F I G
|}
u
A E S / E B U              
0 . A U D I O C O N F I G
|}
u
A E S / E B U              
4 . A E S / E B U   C H 1   F R E Q
| * 1 k H z
4 . A E S / E B U   C H 1   L E V E L
                    - 2 0   [ d B F S ]
Page 92
9 AUDIO CONFIG MENU
78

9.1.3 Setting Clicks

To insert click sounds into the selected channel at the specified interval, follow the procedure below. This is invalid when LIPSYNC(SYNC TO SDI1) is set to ON and the SDI pattern is a lip sync one.
Procedure AUDIO CONFIG > AES/EBU > SETTING > CH1 / CH2 > CLICK
Parameters OFF / 1sec / 2sec / 4sec
Initial value OFF

9.1.4 Settings Shared by Channels

To specify the settings for CH2 (frequency, level, and click sound) to be the same as those for CH1, select ON by following the procedure below. In this case, you cannot specify the settings for CH2.
Procedure AUDIO CONFIG > AES/EBU > SETTING > CH2 > EQUAL TO CH1
Parameters ON / OFF
Initial value OFF

9.1.5 Selecting the Resolution

To select the resolution, follow the procedure below.
Procedure AUDIO CONFIG > AES/EBU > SETTING > RESOLUTION
Parameters 20BIT / 24BIT
Initial value 20BIT
4 . A E S / E B U   C H 1   C L I C K
} * O F F
4 . C H 2   E Q U A L   T O   C H 1
      □ O N             ■ O F F
3 . A E S / E B U   R E S O L U T I O N
      ■ 2 0 B I T       □ 2 4 B I T
Page 93
9 AUDIO CONFIG MENU
79

9.1.6 Selecting the Pre-emphasis Mode

To select the pre-emphasis mode, follow the procedure below.
Procedure AUDIO CONFIG > AES/EBU > SETTING > EMPHASIS
Parameters 50/15 / CCITT / OFF
Initial value OFF

9.1.7 Turning Time Code Insertion On and Off

To turn time code insertion on and off, follow the procedure below. The time code selected with TIME SOURCE on the REFERENCE CONFIG menu is used.
Procedure AUDIO CONFIG > AES/EBU > SETTING > TIMECODE
Parameters ON / OFF
Initial value OFF

9.1.8 Adjusting the Timing

To adjust the timing of the AES/EBU output relative to the reference signal in the range of ±1AES/EBU frame, follow the procedure below.
Procedure AUDIO CONFIG > AES/EBU > TIMING
Parameters ±511 [FS]
Initial value 0 [FS]
3 . A E S / E B U   E M P H A S I S
  □ 5 0 / 1 5   □ C C I T T   ■ O F F
3 . A E S / E B U   T I M E C O D E
      □ O N             ■ O F F
2 . A E S / E B U   T I M I N G
                            0   [ F S ]
Page 94
9 AUDIO CONFIG MENU
80

9.1.9 Turning Lip Sync Interlock On and Off (SER02)

When SDI1 LIP SYNC on the SDI CONFIG menu is set to ON, to output a sound interlocked with the lip sync pattern, select ON by following the procedure below.
[See also] "12.15 Turning Lip Sync On and Off"
Procedure AUDIO CONFIG > AES/EBU > LIPSYNC(SYNC TO SDI1)
Parameters ON / OFF
Initial value OFF

9.2 Setting the Silence Output

Under SILENCE on the AUDIO CONFIG menu, you can specify settings for the silence output.

9.2.1 Settings Shared with the AES/EBU Output

To specify the settings for the silence output (resolution and timing) to be the same as those for the AES/EBU output, select ON by following the procedure below. In this case, you cannot specify the settings for the silence output.
Procedure AUDIO CONFIG > SILENCE > EQUAL TO AES/EBU
Parameters ON / OFF
Initial value OFF
2 . L I P S Y N C ( S Y N C   T O   S D I 1 )
      □ O N             ■ O F F
0 . A U D I O C O N F I G        
|}
S I L E N C E                        
2 . E Q U A L   T O   A E S / E B U
      □ O N             ■ O F F
Page 95
9 AUDIO CONFIG MENU
81

9.2.2 Selecting the Resolution

To select the resolution, follow the procedure below.
Procedure AUDIO CONFIG > SILENCE > SETTING > RESOLUTION
Parameters 20BIT / 24BIT
Initial value 20BIT

9.2.3 Adjusting the Timing

To adjust the timing of the silence output relative to the reference signal in the range of ±1AES/EBU frame, follow the procedure below.
Procedure AUDIO CONFIG > SILENCE > TIMING
Parameters ±511 [FS]
Initial value 0 [FS]
3 . S I L E N C E   R E S O L U T I O N
      ■ 2 0 B I T       □ 2 4 B I T
2 . S I L E N C E   T I M I N G
                            0   [ F S ]
Page 96
9 AUDIO CONFIG MENU
82

9.3 Setting the Word-clock Output

Under WCLK on the AUDIO CONFIG menu, you can specify settings for the word-clock output.

9.3.1 Adjusting the Timing

To adjust the timing of the word-clock output relative to the reference signal in the range of ±1AES/EBU frame, follow the procedure below.
Procedure AUDIO CONFIG > WCLK > TIMING
Parameters ±511 [FS]
Initial value 0 [FS]
0 . A U D I O C O N F I G
|}
W C L K                        
2 . W C L K   T I M I N G
                            0   [ F S ]
Page 97

10 LTC CONFIG MENU

83
10 LTC CONFIG MENU
The LTC CONFIG menu is used to specify settings related to LTC output. To display the LTC CONFIG menu, press CONFIG several times until the following menu appears.
On the LTC CONFIG menu, you can specify settings for LTC1 to LTC3 individually. The procedure below is for LTC1, but the same procedure can also be applied to LTC2 and LTC3.

10.1 Turning the LTC Output On and Off

To turn the LTC output on and off, follow the procedure below.
Procedure LTC CONFIG > LTC OUTPUT > LTC1 > ON/OFF
Parameters ON / OFF
Initial value OFF

10.2 Selecting the LTC Format

To select the LTC format, follow the procedure below.
Procedure LTC CONFIG > LTC OUTPUT > LTC1 > FORMAT
Parameters 30 / 29.97 / 25 / 24 / 23.98 fps
Initial value
29.97 fps (when FORMAT SETTING on the SYSTEM CONFIG menu is set to NTSC) 25 fps (when FORMAT SETTING on the SYSTEM CONFIG menu is set to PAL)
0 . L T C C O N F I G
|}
L T C   O U T P U T              
3 . L T C 1
      □ O N             ■ O F F
3 . L T C 1 F O R M A T
} 2 9 . 9 7 f p s              
Page 98
10 LTC CONFIG MENU
84

10.3 Adjusting the Timing (Frame)

To adjust the timing of the LTC output relative to the reference signal at the frame level, follow the procedure below.
Procedure LTC CONFIG > LTC OUTPUT > LTC1 > TIMING > FRAME
Parameters ±29 [FRAME] (when the LTC format is set to 30 fps or 29.97 fps)
±24 [FRAME] (when the LTC format is set to 25 fps) ±23 [FRAME] (when the LTC format is set to 24 fps or 23.98 fps)
Initial value 0 [FRAME]

10.4 Adjusting the Timing (Bit)

To adjust the timing of the LTC output relative to the reference signal at the bit level, follow the procedure below. At the lower right of the screen, the value in bits converted to time is displayed.
Procedure LTC CONFIG > LTC OUTPUT > LTC1 > TIMING > BIT
Parameters ±39 [BIT]
Initial value 0 [BIT]

10.5 Adjusting the Offset

To adjust the offset of the LTC output relative to the reference signal, follow the procedure below.
Procedure LTC CONFIG > LTC OUTPUT > LTC1 > OFFSET
Parameters ±23:59:59
Initial value +00:00:00
4 . L T C 1 T I M I N G   F R A M E
          0   F R A M E
4 . L T C 1 T I M I N G   B I T
      0   B I T       0 . 0 0 0 m s
3 . L T C 1   O F F S E T
0 0 : 0 0 : 0 0   [ H H : M M : S S ]
Page 99
10 LTC CONFIG MENU
85

10.6 Setting Dropped Frames

To select the dropped frame setting, follow the procedure below. This setting is valid when the frame frequency of the LTC output is set to 29.97.
Procedure LTC CONFIG > LTC OUTPUT > LTC1 > DROP FRAME
Parameters ON: Dropped frame time code is used.
OFF: Non-dropped frame time code is used.
Initial value ON

10.7 Settings Shared by LTC Outputs

To specify the settings for LTC2 to be the same as those for LTC1, select ON by following the procedure below. In this case, you cannot specify the settings for LTC2. Similarly, you can also specify the settings for LTC3 to be the same as those for LTC1.
Procedure LTC CONFIG > LTC OUTPUT > LTC2 > EQUAL TO LTC1
Parameters ON / OFF
Initial value OFF
3 . L T C 1   D R O P F R A M E
      ■ O N             □ O F F
3 . L T C 2 E Q U A L   T O   L T C 1
      □ O N             ■ O F F
Page 100

11 CW/1PPS CONFIG MENU

86
11 CW/1PPS CONFIG MENU
The CW/1PPS CONFIG menu is used to specify settings related to the 10MHz CW output and the 1PPS output. To display the CW/1PPS CONFIG menu, press CONFIG several times until the following menu appears.

11.1 Switching the Output Signal

To select the signal to output from the CW/1PPS connector on the rear panel, follow the procedure below.
Procedure CW/1PPS CONFIG > OUTPUT
Parameters CW / 1PPS
Initial value CW
1 . C W / 1 P P S O U T P U T
      ■ C W             □ 1 P P S    
1 . C W / 1 P P S O U T P U T
      ■ C W             □ 1 P P S    
Loading...