Installation Instructions for
980FSJMSOMDD
Mini-Someday Pendant (LED)
Fusion Jack
GP I :ENERAL RODUCT NFORMATION
This product is ETL listed and suitable only for indoor dry locations and approved for use at any height above the finished floor.
This instruction shows a typical installation.
CAUTION - RISK OF FIRE
This product requires installation by a qualified electrician. Before installing be sure to read all instructions and TURNTHE POWER TO THE ELECTRICAL BOX OFF.
HS749_LED
1.0
Install the Shade
1A
1
GLASS SHADE
FIXTURE FRAME
Adjust the Fixture Height
2B
ALLEN WRENCH
SET SCREW
CONNECTOR
3
Back out (do not remove) the set screw on tip of the connector with the provided Allen wrench.
2C
ALLEN WRENCH
SET SCREW
4
3
1
Slip the cord through the glass shade and gently lower the glass shade onto the .
fixture frame
4
Back out (do not remove) the set screw on the conical connector with the provided Allen wrench.
1
Page 2
2D
5
5
Gently twist the end of the coaxial cable between thumb and forefinger.
2E
SURFACE
PLATE
6
Tap the conical connector on a hard surface with the set screw facing down, so the plate inside drops into place.
2G
ALLEN WRENCH
9
Look into the sight hole on the top of the connector to make
INNER WIRE
SIGHT HOLE
10
sure that the inner wire is contacting the end of the connector.
10
Hold the coaxial cable in place and tighten the set screw on tip of the connector with the provided Allen wrench. Make sure this set screw connection is tight.
2H
11
9
2F
7
CONICAL CONNECTOR
7
Feed and push the coaxial cable into the conical connector.The coaxial cable will come to a stop point after being inserted 3/4" into the conical connector.
2G
8
WRINKLE ON OUTER WRAPPED WIRE
8
Keep pushing the coaxial cable into the connector while rotating the connector to ease feeding the inner wire into the tip of the connector.The outer wrapped wire will start wrinkling while being inserted another 1/2" into the connector.
OUTER WRAPPED WIRE STOPS HERE
INNER WIRE STOPS HERE
11
Firmly tighten the set screw on the conical connector.
2I
12
12
Pull the coaxial cable toward the fixture to smooth the wrinkles.
2
Page 3
Install the Lamp
3A
NOTE:To reduce the risk of a burn or electric shock
during relamping, disconnect the power to the fixture.
1
1
1
Lift the and glass shade up to expose the socketfixture frame assembly.
FIXTURE FRAME
GLASS SHADE
SOCKET
3C
FIXTURE FRAME
GLASS SHADE
SOCKET
3
Gently lower the fixture frame and glass shade until they rest properly on the socket assembly.
NOTE: To re-lamp,reverse section 3 instructions.
3B
2
NOTE:Use only your fingers to replace the lamp.
The lamp is rated at 6 watts at 12 volts.
SOCKET
LAMP
2
Screw the lamp into the socket.
3