Installation Instructions for
980MROCKCWCF
Mini-Rock Candy Cylinder Wall (Compact Fluorescent)
WALL
GENERAL PRODUCT INFORMATION:
This product is suitable for damp locations.
This product can mount either to a 4” square electrical box with a
round plaster ring or an octagon electrical box.
This instruction shows a typical instruction.
CAUTION - RISK OF FIRE
This product requires installation by a qualified
electrician. Before installing be sure to read all
instructions and TURNTHE POWER TO THE
ELECTRICAL BOX OFF.
PW623_CF
1.0
Install the Fixture
1A
1
1
With the Allen wrench provided, back out (do not fully
remove) the set screws at the base of the fixture.
2
Remove the mounting plate from the back of the
fixture.
SET SCREW
ALLEN WRENCH
MOUNTING
PLATE
1B
BALLAST
5
3
Connect the mounting plate ground wire to a suitable
63
ground in accordance to local electrical codes.
Connect the white ballast wire to the neutral power line
64
wire with a wire nut.
65
Connect the black ballast wire to the hot power line
wire with a wire nut.
1
4
1C
1E
NOTCHED END
#8-32 SCREW
7
MOUNTING
PLATE
6
Place all wire, wire connections, and ballast inside the
7
electrical box.
SCREW
WASHER
Slide a #8 screw through a washer and screw it into an
612
SCREW
WASHER
anchor. Repeat for the other anchor to secure the
mounting plate to the wall.
1F
12
7
Attach the mounting plate to the electrical box using
the two #8-32 screws provided. Make sure the notched
end of the mounting plate is at the top.
1D
ANCHOR
8
Verify that the mounting plate is level before continuing.
ANCHOR
13
613
Hook the top of the sconce to the top of the mounting
plate and swing the bottom of the sconce toward the
plate until it is flush with the wall.
614
Tighten the set screw at the bottom of the sconce to
secure it to the mounting plate.
9
Line up an anchor tip with the center of the mounting
plate hole and push the anchor into the wall up to the
threads.
610
Screw the anchors in the rest of the way.
Repeat steps 4-6 for the other anchor.
611
2