LBL Lighting Linea User Manual

Installation Instructions for
980LINEAW
Linea
Wall
GP I :ENERAL RODUCT NFORMATION
This product is suitable for damp locations.
This instruction shows a typical installation.
LN_0SI
CAUTION - RISK OF FIRE
This product must be installed in accordance with the applicable installation code by a person familiar with the construction and operation of the product and the hazards involved.
Use minimum 90°c supply conductors.
1.3
Install the Fixture
1A
CROSSBAR ASSEMBLY
3
#8-32 FLAT HEAD SCREW
POWER LINEWIRES
NOTE: Do not disassemble the crossbar assembly.
Feed the power line wires through the nipple attached to the
1
crossbar assembly.
Mount the crossbar assembly to the electrical box with the
2
two #8-32 flat head screws.
3
Make sure that the crossbar assembly is grounded in accordance with local electrical codes.
1
2
1B
BACKPLATE
4
SOCKET HOUSING
4
Remove the backplate from the socket housing.
1C
7
5
Feed the power line wires through the backplate center hole. Slide the backplate center hole onto the nipple attached to the crossbar.
8
5
END HOLE
6
BACKPLATE
7
6
Hold the backplate against the wall.
7
Level the backplate horizontally and mark the two end holes on to the wall.
8
Remove the backplate.
1
1D
MARKED POINT
1G
BACK PLATE
END HOLE
16
9
ANCHOR
9
Push the anchors into the marked points on the wall up to the
10
threaded portion.
10
Screw the anchors in the rest of the way with a Phillips screwdriver.
1E
ROUND PLATE
LOCK WASHER
12
WASHER
NUT
11
Feed the power line wires through the round plate center hole,
11
backplate center hole, lock washer, washer, and nipple.
BACKPLATE
ANCHOR
13
END HOLE
12
SOCKET
#8 SCREW
16
Place all wires and wire nut connections into the socket
SOCKET HOUSING
housing.
17
Push the two #8 screws through the screw hole next to the each socket.Tighten the screws to the anchors through the end holes in backplate.
Install the Lamp
2A
LAMP CONTACT
2
1
SWITCH
1717
SOCKET
2
12
Slide the round plate and backplate onto the nipple attached to the crossbar. Level the backplate horizontally and line up the end holes with the anchors.
13
Tighten the nut to secure the round plate and backplate in place.
1F
15
SOCKET HOUSING
14
Connect the black fixture wire to the hot power line wire with a wire nut.
15
Connect the white fixture wire to the neutral power line wire with a wire nut.
16
Use 120 Volt, WattType Linestra IncandescentMAX 60 Single Contact Double S14S Base Lamp With Model LN60SI.
Use 120 Volt, WattType Linestra Incandescent
MAX 150
Single Contact Double S14S Base Lamp With Model LN120SI.
1
Turn off power to the fixture.
Push the lamp so the contacts snap into the sockets.
2
3
Turn the power to the fixture on.
SAVETHESE INSTRUCTIONS!
7400 Linder Ave, Skokie, IL 60077