Installation Instructions for
980LINEAW
Linea
Wall
GP I :ENERAL RODUCT NFORMATION
This product is suitable for damp locations.
This product can mount to either a 4" square electrical box with
round plaster ring or an octagon electrical box.
This instruction shows a typical installation.
LN_0SI
CAUTION - RISK OF FIRE
This product must be installed in accordance with
the applicable installation code by a person familiar
with the construction and operation of the product
and the hazards involved.
Use minimum 90°c supply conductors.
1.3
Install the Fixture
1A
CROSSBAR
ASSEMBLY
3
#8-32 FLAT
HEAD SCREW
POWER LINEWIRES
NOTE: Do not disassemble the crossbar assembly.
Feed the power line wires through the nipple attached to the
1
crossbar assembly.
Mount the crossbar assembly to the electrical box with the
2
two #8-32 flat head screws.
3
Make sure that the crossbar assembly is grounded in
accordance with local electrical codes.
1
2
1B
BACKPLATE
4
SOCKET HOUSING
4
Remove the backplate from the socket housing.
1C
7
5
Feed the power line wires through the backplate center hole.
Slide the backplate center hole onto the nipple attached to the
crossbar.
8
5
END HOLE
6
BACKPLATE
7
6
Hold the backplate against the wall.
7
Level the backplate horizontally and mark the two end holes
on to the wall.
8
Remove the backplate.
1
1D
MARKED POINT
1G
BACK PLATE
END HOLE
16
9
ANCHOR
9
Push the anchors into the marked points on the wall up to the
10
threaded portion.
10
Screw the anchors in the rest of the way with a Phillips
screwdriver.
1E
ROUND PLATE
LOCK WASHER
12
WASHER
NUT
11
Feed the power line wires through the round plate center hole,
11
backplate center hole, lock washer, washer, and nipple.
BACKPLATE
ANCHOR
13
END HOLE
12
SOCKET
#8 SCREW
16
Place all wires and wire nut connections into the socket
SOCKET HOUSING
housing.
17
Push the two #8 screws through the screw hole next to the
each socket.Tighten the screws to the anchors through the
end holes in backplate.
Install the Lamp
2A
LAMP CONTACT
2
1
SWITCH
1717
SOCKET
2
12
Slide the round plate and backplate onto the nipple attached to
the crossbar. Level the backplate horizontally and line up the
end holes with the anchors.
13
Tighten the nut to secure the round plate and backplate in
place.
1F
15
SOCKET HOUSING
14
Connect the black fixture wire to the hot power line wire with
a wire nut.
15
Connect the white fixture wire to the neutral power line wire
with a wire nut.
16
Use 120 Volt, WattType Linestra IncandescentMAX 60
Single Contact Double S14S Base Lamp With Model
LN60SI.
Use 120 Volt, WattType Linestra Incandescent
MAX 150
Single Contact Double S14S Base Lamp With Model
LN120SI.
1
Turn off power to the fixture.
Push the lamp so the contacts snap into the sockets.
2
3
Turn the power to the fixture on.
SAVETHESE INSTRUCTIONS!
7400 Linder Ave, Skokie, IL 60077
800.323.3226 - 847.626.6300
www.lbllighting.com
© 2014 LBL Lighting.All rights reserved. The "LBL Lighting" graphic is a
registered trademark of LBL Lighting. LBL Lighting reserves the right to
change specifications for product improvements without notification.
2
A Generation Brands Company