LBL Lighting LED Illum MO Direct Feed Surf Mag Xfmr User Manual

Installation Instructions for
12 Volt 300 Watt Single Direct Power Feed Magnetic Surface MountTransformers
LED-Illuminated Monorail
CAUTION - RISK OF FIRE
This product must be installed in accordance with the applicable installation code by a person familiar with the construction and operation of the product and the hazards involved.
Use minimum 90°c supply conductors.
980MRLDSFMT30SMT-LED
TRANSDIRSFM300SC-LED_
1.2
GP I :ENERAL RODUCT NFORMATION
A typical installation is shown. Specific installation must be in accordance with local electrical codes.
This product may be dimmed only with a low voltage magnetic dimmer. Using a dimmer not designed for low voltage magnetic applications may cause undesirable noise and potentially shorten the life of the transformer.
This product is intended for use with LBL Lighting low voltage lighting systems only.
Read all instructions thoroughly. Read "Important Safety Information" on next column before proceeding with the installation.
Important Safety Information
Do not conceal or extend bus bar conductors through a building wall.
Do not install this lighting system in a damp or wet location.
To reduce the risk of fire and burns, do not install this lighting system where the uninsulated open bus bar conductors can be shorted or contact any conductive materials.
To reduce the risk of the system overheating and possibly causing a fire, make sure all the connections are tight.
Do not install fixture assemblies closer than six inches to curtains or similarly combustible materials.
Turn the electrical power off before modifying the lighting system in any way.
The fixtures used with the system must be identified to be used with the corresponding system.
Minimum volume of the electrical box must be 6 cubic inches (98 cubic centimeters).
Load the circuit of the surface mount transformer to no more than the maximum rated capacity as specified.
1
Install the Transformer
1A1A
3/32 ALLEN WRENCH
1
#8-32 FLAT HEAD SCREW
Loosen the three #8-32 flat head screws(Do Not Remove)
1
BACKPLATE
3
1
with the provided 3/32 Allen wrench.
2
Rotate the backplate counter clockwise so that the #8-32 flat head screws are lined up with vertical cut out portion of the "L" slots.
3
Remove the backplate from the housing.
1A1B
HOUSING
1A1C
6
5
BACKPLATE BRACKET
SAFETY WIRE
5
Hook the transformer safety wire onto the backplate bracket.
6
Connect the backplate green wire to the ground in accordance
7
with local electrical codes.
8
5
#8-32 SCREW
4
BACKPLATE
CAUTION: Turn the power to electrical box off!
4
Mount the backplate to the electrical box with the provided
4
two #8-32 screws.
7
Connect the transformer white wire to the neutral power line wire with a wire nut.
8
Connect the transformer black wire to the hot power line wire with a wire nut.
1A1D
#8-32 FLAT HEAD SCREW
11
3/32 ALLEN WRENCH
9
Slide the vertical portion of the housing "L" slots completely
11
onto the three backplate #8-32 flat head screws.
10
Rotate the transformer housing clockwise to lock the housing slots around the #8-32 flat head screws.
HOUSING
Tighten the three #8-32 flat head screws with the 3/32 Allen
11
wrench to secure the transformer in place.