Installation Instructions for
60 Watt Electronic Direct Power Feed
CanopyTransformer
LED-Illuminated Monorail
980MRLSFELEDDCT-LED
TRANSDIRSFE60_-LED
1.2
GP I :ENERAL RODUCT NFORMATION
This product is ETL listed only when all the products used are
supplied by LBL Lighting, is suitable only for indoor dry locations
and approved for use at any height above the finished floor.
This product may be dimmed only with a low voltage electronic
dimmer. Using a dimmer not designed for low voltage electronic
applications may cause undesirable noise and potentially shorten
the life of the transformer.
Minimum volume of the electrical box must be 6 cubic inches (98
cubic centimeters).
This product is intended for use with LBL low voltage lighting
systems only.
Read all instructions thoroughly before beginning installation.
Install the Power Feed Canopy
1A1A
Important Safety Information
To reduce the risk of fire and burns, do not install this lighting
system where the uninsulated open bus bar conductors can be
shorted or contact any conductive materials.
To reduce the risk of the system overheating and possibly causing a
fire, make sure all the connections are tight.
Do not install fixture assemblies closer than 6 inches to curtains or
similarly combustible materials.
Turn the electrical power off before modifying the lighting system in
any way.
The fixtures used with the system must be identified to be used
with the corresponding system.
Minimum volume of the electrical box must be 6 cubic inches (98
cubic centimeters).
Load the circuit of the surface mount transformer to no more than
the maximum rated capacity as specified.
NOTE: Use the provided universal round crossbar when the
canopy holes do not line up with the electrical box holes.
2
TRANSFORMER
POWER LINE WIRES
3
5
77
#8-32 SCREW
1
Disconnect power to the electrical box.
2
Connect the white transformer wire to the neutral power line
wire with a wire nut.
3
Connect the black transformer wire to the hot power line
wire with a wire nut.
4
Connect a suitable ground in accordance with local electrical
codes.
5
Connect the canopy wires to the transformer output wires
with wire nuts.
6
Place the transformer, wires, and wire nut connections inside
the electrical box.
7
Mount power feed canopy to the electrical box with the two
#8-32 screws.
1
Connect the MonoRail to the
Transformer Canopy
1A2A
POWER FEED
HOUSING
1
POWER
FEED CAP
2
NOTE:The standoffs should be installed to support the
LED-Illuminated Monorail while connecting LED-Illuminated
Monorail to the power feed canopy. Refer to the instruction
provided with the standoffs.
1
Remove the power feed cap from the power feed housing.
SCREW
1A2C
POWER
FEED CAP
5
5
Tighten the screw on the power feed cap for proper power
connection.
SCREW
2
Completely back out the screw on the power feed cap.
1A2B
LED-ILLUMINATED
MONORAIL
3
4
POWER
FEED CAP
3
Place the LED-Illuminated Monorail into the standoffs and
power feed housings.
4
Screw the power feed cap completely to the power feed
housing. Make sure that the power feed cap is not cross
threaded.
POWER FEED
HOUSING
SAVETHESE INSTRUCTIONS!
7400 Linder Ave, Skokie, IL 60077
800.323.3226 - 847.626.6300
www.lbllighting.com
© 2014 LBL Lighting.All rights reserved. The "LBL Lighting" graphic is a
registered trademark of LBL Lighting. LBL Lighting reserves the right to
change specifications for product improvements without notification.
2