LBL Lighting Iris WCF3 User Manual

Installation Instructions for
980IRISWCF3
Iris 2X13W Compact Fluorescent Wall
Wall
GENERAL PRODUCT INFORMATION:
This product is suitable for damp locations.
CAUTION - RISK OF FIRE
This product must be installed in accordance with the applicable installation code by a person familiar with the construction and operation of the product and the hazards involved.
Use minimum 90°c supply conductors.
PWAP11_SC213_
1.4
Install the Fixture
MOUNTING PLATE
2
3
1
In accordance with local electrical codes, make sure that the mounting plate is grounded.
2
Connect the fixture white wire to the neutral power line wire with a wire nut.
3
Connect the fixture black wire to the hot power line wire with a wire nut.
1B1A
5
5
4
#8-32 SCREW
4
Place all wires and wire nut connections properly inside the electrical box.
5
Align the mounting plate holes with electrical box holes and tighten the two #8-32 screws to secure the fixture in place.
ELECTRICAL BOX HOLE
1
1
Install the Lamp & Shade
2A
LAMP
LAMP PIN
1
SOCKET
For The Fixtures With Electronic Ballast, Use MAX 13 Watt Type Quad Tube G24q-1
Base 4-PIN Compact Fluorescent Lamp, With Each Socket.
For The Fixtures With Magnetic Ballast, Use MAX 13 Watt Type Quad Tube
GX23-2 Base Compact Fluorescent Lamp, With Each Socket.
1
Push the lamp pins completely into the socket holes.
2B
2
THUMB SCREW
2
Place the glass shade onto the mounting plate. Align the glass shade holes with the mounting plate holes. Tighten the thumb screws to secure the glass shade in place.
GLASS SHADE
SAVE THESE INSTRUCTIONS!
2
NOTE: Do not over tighten the thumb screws which may
cause the glass shade to break.