Installation Instructions for
980FSJ4PSC
Fusion Jack
GP I :ENERAL RODUCT NFORMATION
This product is suitable for indoor dry locations only.
This product can be dimmed with a standard incandescent dimmer.
Install the Canopy
CK004S-FJ_
CAUTION - RISK OF FIRE
This product must be installed in accordance with the applicable installation code by a person familiar with the construction and operation of the product and the hazards involved.
Use minimum 90°c supply conductors.
1.0
1A 1C
1
#8-32 SCREW
1
Remove the four #8-32 screws on the sides of the canopy housing.
2
Lift the mounting plate from the canopy housing.
CANOPY HOUSING
1B
MOUNTING PLATE
2
1
MOUNTING PLATE
1
4
5
1D
3
3
3
3
5
4
5
ANCHOR
With a hammer tap the anchors at the marked points into the ceiling up to the threaded portion.
Screw the anchors in the rest of the way with a Phillips screwdriver.
6
8
5
ANCHOR
8
#8-32 SCREW
3
Align the mounting plate slots with the electrical box holes and mark four points onto the ceiling through the mounting holes.
6
Ground the mounting plate in accordance with local electrical codes.
7
Feed the power line wires through the mounting plate center hole.
Line up the two mounting plate slots with the electrical box
8
holes and use the two provided #8-32 screws to mount it to
1
1E 1H
9
9
9
9
16
16
16
#8 SCREW
Secure the mounting plate to the anchors with the provided
9
#8 screws.
1F
SAFETY BRACKET
SAFETY CABLE
SAFETY BRACKET
10
Insert one end of the safety cable into the mounting plate safety bracket and insert the other end into the housing safety bracket.
10
10
#8-32 SCREW
15
15
Slide the housing onto the mounting plate and line up the housing holes with the mounting plate holes.
141716
Replace and tighten the four #8-32 screws to secure the housing in place.
1I
FIXTURE
FUSION JACK PORT
CAUTION: load perRISK OF FIRE. Maximum
FUSION JACK
port is watt.60 Do Not Overload!
Screw each fixture Fusion Jack completely into the Fusion Jack port.
17
1G
12
11
11
Connect the housing green wire to the mounting plate ground wire with a wire nut.
12
Connect the housing white wire to the neutral power line wire with a wire nut.
13
Connect the housing black wire to the hot power line wire with a wire nut.
14
14
Place all wires and wire nut connections properly inside the housing.
13
18
Turn the power on.
SAVETHESE INSTRUCTIONS!