LBL Lighting Fusion Jack Canopy 3 Light Rectangle LED User Manual

Installation Instructions for
980FSJ3PLC
3 Rectangle Fusion Jack Canopy
Fusion Jack
GP I :ENERAL RODUCT NFORMATION
This product is suitable for indoor dry locations only.
This product can be dimmed with a standard incandescent dimmer.
Install the Canopy
CK003R-FJ_
CAUTION - RISK OF FIRE
This product must be installed in accordance with the applicable installation code by a person familiar with the construction and operation of the product and the hazards involved.
Use minimum 90°c supply conductors.
1.1
1A 1C
MOUNTING PLATE
1
#8-32 SCREW
1
Remove the six #8-32 screws on the sides of the canopy housing.
2
Lift the mounting plate from the canopy housing.
1 1
2
CANOPY HOUSING
4
5
1B 1D
3 3
MOUNTING PLATE
4
ANCHOR
With a hammer tap the anchors at the marked points into the ceiling up to the threaded portion.
Screw the anchors in the rest of the way with a Phillips screwdriver.
7 7
5
ANCHOR
#8-32 SCREW
3
Align the mounting plate slots with the electrical box holes and mark two points onto the ceiling through the mounting holes.
6
Feed the power line wires through the mounting plate center hole.
7
Line up the two mounting plate slots with the electrical box holes and use the two provided #8-32 screws to mount it to the electrical box.
1E 1H
8
#8 SCREW
8
Secure the mounting plate to the anchors with the provided #8 screws.
8
15
16
1F
SAFETY BRACKET
MOUNTING PLATE
16
15
16
16
Slide the housing onto the mounting plate and line up the housing holes with the mounting plate holes.
Replace and tighten the six #8-32 screws to secure the housing in place.
9
SAFETY CABLE
9
HOUSING
9
Insert one end of the safety cable into the mounting plate
10
10
safety bracket and insert the other end into the housing safety bracket.
10
Repeat step 9 for the other safety cable.
1G
11
13
14
12
1I
17 17
FUSION JACK PORT
CAUTION: load perRISK OF FIRE. Maximum
port is watt.60 Do Not Overload!
17
Screw each fixture Fusion Jack completely into the Fusion Jack port.
Turn the power on.
18
17
FIXTURE FUSION JACK
11
Make sure the mounting plate is grounded in accordance with local electrical codes.
12
Connect the housing white wire to the neutral power line wire with a wire nut.
13
Connect the housing black wire to the hot power line wire with a wire nut.
14
Place all wires and wire nut connections properly inside the housing.
SAVE THESE INSTRUCTIONS!
7400 Linder Ave, Skokie, IL 60077
800.323.3226 - 847.626.6300
www.lbllighting.com
© 2008 LBL Lighting.All rights reserved. The "LBL Lighting" graphic is a registered trademark of LBL Lighting. LBL Lighting reserves the right to change specifications for product improvements without notification.
A Generation Brands Company
Loading...