Installation Instructions for
980FSJ2C
Fusion Jack 2.75" Flush Canopy
Fusion Jack
Fusion Jack
GP I :ENERAL RODUCT NFORMATION
This product is suitable for dry locations only.
Model numbers ending in “-LED” or “-LED277” can be dimmed
with a low-voltage electronic dimmer, have a rated maximum output
of 60 watts, and are compatible with LED elements.
All other model numbers can be dimmed with a standard
incandescent dimmer, have a rated maximum output of 75 watts,
and are not compatible with LED elements.
Install the 2.75" Canopy
CK001I-FJ2-_
CAUTION - RISK OF FIRE
CAUTION - RISK OF FIRE
This product must be installed in accordance with
This product must be installed in accordance with
the applicable installation code by a person familiar
the applicable installation code by a person familiar
with the construction and operation of the product
with the construction and operation of the product
and the hazards involved.
and the hazards involved.
Use minimum 90°c supply conductors.
Use minimum 90°c supply conductors.
1.1
1A
2” ELECTRICAL BOX
2
4
TRANSFORMER
NOTE:The 2” electrical box must be installed prior to
these steps. Refer to the instruction sheet provided with
the electrical box.
1
Disconnect power to the electrical box.
2
Connect the green transformer wire to a suitable ground
according to local electrical codes.
5
3
1B
FRONT BRACKET
6
Insert the front bracket into the 2” electrical box.
2" ELECTRICAL BOX
3
Connect the white transformer wire to the neutral
power line wire with a wire nut.
4
Connect the black transformer wire to the hot power
line wire with a wire nut.
5
Place the transformer inside the electrical box.
1
1C
1E
#6 SCREW
7
Adjust the front bracket so that it is flush with the
8
8
FRONT
BRACKET
drywall.
8
Replace and tighten the two remaining #6 screws on
the front bracket to secure it in place.
1D
LOWVOLTAGE
WIRES
9
9
11
ALLEN
WRENCH
11
Mount the canopy to the electrical box with the two #8-
#8-32 SCREW
11
32 screws using the provided 3/32 Allen wrench.
1F
FUSION JACK PORT
12
1
FUSION JACK
CANOPY
9
Connect each canopy wire to a low voltage wire with a
wire nut.
10
Place all wire and wire nut connections properly inside
the electrical box.
12
Screw the Fusion Jack into the Fusion Jack port.
13
Turn the power on.
SAVETHESE INSTRUCTIONS!
7400 Linder Ave, Skokie, IL 60077
800.323.3226 - 847.626.6300
www.lbllighting.com
© 2009 LBL Lighting.All rights reserved. The "LBL Lighting" graphic is a
registered trademark of LBL Lighting. LBL Lighting reserves the right to
change specifications for product improvements without notification.
2