LBL Lighting Final Call Medium User Manual

Installation Instructions for
980FNLCMW
Final Call Medium Bath
Wall
GENERAL PRODUCT INFORMATION:
This product is suitable for damp locations.
This product can mount either to a 4” square electrical box with a round plaster ring or an octagon electrical box.
This instruction shows a typical installation.
CAUTION - RISK OF FIRE
This product requires installation by a qualified electrician. Before installing be sure to read all instructions and TURNTHE POWER TO THE ELECTRICAL BOX OFF.
PW674_CF
1.0
Install the Fixture Base
1A
FIXTURE BASE
FIXTURE SCREW
1
1
With the Allen wrench provided, remove the two fixture screws.
Separate the front cover from the fixture base.
2
2
FRONT COVER
ALLEN WRENCH
1
FIXTURE SCREW
1
1B
#8-32 SCREW
1D
BACKPLATE SCREWS
CROSSBAR
ELECTRICAL BOX
#8-32 SCREW
23
Align the backplate mounting screws horizontally and mount the crossbar to the electrical box with the two #8-32 screws provided.
1C
BACKPLATE SCREWS
THUMB NUT THUMB NUT
7
Install the fixture base onto the crossbar and secure it tightly with the two thumb nuts.
4
5
4
Connect the mounting plate ground wire to a suitable ground according to local electrical codes.
5
Connect the white fixture wire to the neutral power line wire with a wire nut.
3
6
Connect the black fixture wire to the hot power line wire with a wire nut.
2