LBL Lighting Batons Chandelier SCH User Manual

Page 1
Installation Instructions for
980BATONSCH
Batons
Chandeliers
GP I :ENERAL RODUCT NFORMATION
This product can mount to either a 4" square electrical box with round plaster ring or an octagon electrical box.
This product is suitable for indoor dry locations only.
This product can be dimmed with an electronic dimmer.
Optional Heads GB1AM, GB1BU, GB1FR, GB1GR, GB1RD are the compatible accessories.
CAUTION - RISK OF FIRE
This product must be installed in accordance with the applicable installation code by a person familiar with the construction and operation of the product and the hazards involved.
Use minimum 90°c supply conductors.
HS20612_FRSC
1.0
Install the Fixture
1A
CAP NUT
1
Remove the two cap nuts on the dome cover.
1
1B
1C
ELECTRICAL BOX
CANOPY HOUSING
1
1
DOME COVER
CROSSBAR
3
#8-32 SCREW
3
Mount the crossbar to the electrical box with the two #8-32 screws.
3
1D
CANOPY HOUSING
4
CANOPY HOUSING
1
Remove the canopy housing from the dome cover.
2
2
DOME COVER
POWERWIRE
4
Feed the power wires through the canopy housing center hole.
1
Page 2
1E
1G
9
5
5
5
Align the canopy housing holes to the crossbar threaded holes and completely tighten the two provided #8-32 screws to secure the canopy housing in place.
1F
6
7
8
#8-32 SCREW
THREADED ROD
10
9
Place all wires and wire nut connections properly inside the
CAP NUT
10
canopy housing.
10
Slide the dome cover onto the threaded rods and secure it in place by tightening the cap nuts completely to the threaded rods.
6
In accordance with local electrical codes, make sure that the canopy housing is grounded.
7
Connect the fixture white wire to the neutral power line wire with a wire nut.
8
Connect the fixture black wire to the hot power line wire with a wire nut.
2
Page 3
Install the Fixture Arms
Install the Lamp & Glass Shade
2A
M3 SET SCREW
3A
DOME COVER
POWER
10
6
7
1
12
4
3
11
2
8
5
9
POST
1
SOCKET
NOTE:Use only your fingers and a soft cloth to install
the lamp.
Use Watt Bi-Pin Xenon (Xelogen)MAX 10 Lamp With Each Socket.
1
For each socket, push the lamp pins completely into the socket holes.
WARNING: RISK OF FIRE
1
1
2
DOME COVER
Never replace a Xenon (Xelogen) lamp with a regular Halogen lamp.A regular Halogen lamp requires a protective glass shield.
LAMP
1.5 MM ALLEN WRENCH
1
Starting with the socket assembly wires marked 1 and 2,insert
SOCKET ASSEMBLE WIRE
the assembly wire marked 1 into the dome cover power post that is marked 1.Tighten the M3 set screw with the provided
1.5 MM Allen wrench to secure the wire in place.
2
While supporting the socket assembly, insert the wire marked 2 into the dome cover power post marked 2.Tighten the M3 set screw with the 1.5 MM Allen wrench to secure the socket assembly in place.
Repeat steps 1 and 2 to attach other socket assemblies in
3
ascending order as marked on the wires.
3B
SOCKET
2
SPRING CLIP
2
Push the glass shade completely onto the spring clip.
GLASS SHADE
3
Page 4
SAVETHESE INSTRUCTIONS!
7400 Linder Ave, Skokie, IL 60077
800.323.3226 - 847.626.6300
www.lbllighting.com
© 2014 LBL Lighting.All rights reserved. The "LBL Lighting" graphic is a registered trademark of LBL Lighting. LBL Lighting reserves the right to change specifications for product improvements without notification.