Lanier LD232C, LD228C, LD238C User Manual

A
Lanier Worldwide, Inc. 2300 Parklake Drive, NE
tlanta, GA USA 30345-2979
MATERIAL SAFETY DATA SHEET
Emergency Telephone: 800-551-3087
Section 1: Chemical Product and Company Information
Identity:
Toner Cassette P1 Magenta
Product ID: 480-0202 Issued: 11/09/2004 Synonyms
& Common Names:
Uses: Chemical
Magenta Toner Cassette P1 for LD232c, LD238c, LD228c
Lanier LD232c, LD238c, LD228c Mixture
Formula:
MSDS No.
Supersedes:
Date:
Prepared by:
Approved by:
European
Contact:
CP- 409 01/26/2004
11/09/2004 EH&S Department 770-496-9500
Larry Choskey, Manager, CEH&S Walter Fricke, Manager, Safety & Environment, Lanier Worldwide, Inc. Im Taubental D-41468 Neuss, Germany +49-2131-387-177
Section 2: Composition / Information on Ingredients
Component Percent CAS No. Exposure Limits Source
Polyole resin > 85 Confidential Not listed N/a Organic Pigment <10 5281-04-9 Not listed N/a Organic salt <5 Confidential Not listed N/a
Section 3: Hazards Identification
HMIS Rating:
FLAMMABILITY = 1 HEALTH = 1 REACTIVITY = 0 SPECIAL = none
Health Hazards (Acute, Chronic, Immediate and Potential): Minimum irritation to respiratory tract may occur as with exposure to any non-toxic dust. May cause gasping if inhaled. Inhalation should be avoided. May cause temporary eye discomfort.
Health Hazards of Long Term exposure (Chronic): No data is available on this product Carcinogenicity: This product does not contain the carcinogenic substances, which are listed in NTP, IARC, and are regulated by
OSHA.
Section 4: First Aid Measures
Inhalation:
Skin Contact:
Gargle with water. Remove to fresh air if effects occur. Get medical attention if needed.
Wash with soap and water.
Eye Contact:
Ingestion:
In case of contact, immediately flush eyes with water for 15 minutes. Get medical attention if needed. Dilute stomach contents with several glasses of water. Get medical attention.
Section 5: Fire Fighting Measures
Suitable extinguishing media: CO
B
B, dry chemical, foam or water.
2
Special protective equipment for fire fighters: none UEL: n/a LEL: n/a
Extinguishing media which may not be used for safety reasons: none
your document management partner
MATERIAL SAFETY DATA SHEET
Page 2 of CP-409
Section 6: Accidental Release Measures
Spill / leak Procedures: If spilled, sweep up using an approved toner vacuum with a 0.5 micron filter or smaller, such as the Atrix AAA Toner Vacuum or 3M Toner Vacuum. Use of a vacuum cleaner not rated for toner particles, could result in a fire or personal injury. Remove residue with soap and cold water. Miscellaneous: Keep product out of sewers and watercourses. Personal protection: Avoid inhalation of dust.
Section 7: Handling and Storage
Special Handling: Cleanse skin after contact before breaks or meals, and end of workday.
Special Storage: Avoid direct sunlight. Keep out of reach of children. Store in a cool, dry place. Below 35C (95F)
Do not handle in areas where the wind blows. Minimize the breathing of dust.
Section 8: Exposure Control and Personal Protection Information:
Respiratory Protection: none required under normal use. Hand Protection: none required under normal use. Eye Protection: none required under normal use. Skin Protection: none required under normal use.
Section 9: Physical and Chemical Properties
CHARACTERISTICS: Appearance: Magenta Melting point: N/a Form: Powder Vapor pressure: N/a Odor: Slight plastic odor Vapor density: N/a Solubility in Water: Insoluble Evaporation rate: N/a Density: N/a Boiling point: N/a
Section 10: Stability and Reactivity
Conditions to avoid: none Materials to avoid: none Hazardous decomposition products: Will not occur Stability: Stable
Section 11: Toxicological Information:
Ames test negative Acute skin irritation: n/a Acute oral toxicity: >5000mg/kg (rat) Acute allergenic effects: n/a
Special effects: Mutagenicity: Ames Test Negative Effects on reproductive system: No data is available on this product Teratogenic: No data
Section 12: Environmental / Ecological Information
Acute toxicity to fish: N.A. Bioaccumulation: Not known in bioaccumulation Persistence/Degradability: Not known Acute toxicity to daphnia: Not available Algae inhibition test: Not available
Section 13: Disposal Consideration
Used Toner should be disposed of under conditions that meet all federal, state and local environmental regulations. Disposal regulations vary from locality to locality; therefore consult your local Lanier office or the EPA to determine the proper method for disposal. Do not incinerate loose or spilled Toner.
Section 14: Transportation Information
International regulations: RID/ADR Not applicable ICAO-TI/ATA-DGR Not applicable DOT 49 CFR Not applicable UN Classification Number Not applicable ADNR Not applicable IMDG Code Not applicable
Specific precautionary transport measures: Avoid direct sunlight. Do not keep over 35°C (95°F). Specific material to avoid: None in normal use.
Information on this data sheet represents our current data and best opinion as to the proper use in handling of this product under normal conditions.
usual precautionary measures for dealing with chemicals.
On the basis of the data available to us, this product is not a dangerous substance. One should, however, observe the
Loading...