MODEL: SR-18-8T
Installation
Operation
Maintenance
Manual
Lang Manufacturing Company 6500 Merrill Creek Parkway Everett, WA 98203
Part Number: 60802-17 Ph: 425-349-2400 Fax: 524-349-2733 January 1994
INSTALLATION
RECEIVING THE MODEL SR-18 STOCK POT RANGE
Upon receipt, check for freight damage, both visible and concealed. Visible damage should be
noted on the freight bill at the time of delivery and signed by the carrier's agent. Concealed loss
or damage means loss or damage which does not become apparent until the merchandise has
been unpacked. If concealed loss or damage is discovered upon unpacking, make a written
request for inspection by the carrier's agent within 15 days of delivery. All packing material
should be kept for inspection. Do not return damaged merchandise to Lang Manufacturing
Company. File your claim with the carrier.
Uncrate your Stock Pot Range as near its intended location as practical. The crating will help
protect the unit from the physical damage normally associated with moving it through hallways
and doorways.
VENTILATION AND CLEARANCES
The installation of any components such as vent hoods, grease extractors, or fire extinguisher
systems, must conform to their applicable nationally recognized installation standards.
Caution
Caution
Caution
Caution
Minimum clearance from combustible construction shall be:
3 inches from side walls
3 inches from back wall
DATA PLATE INFORMATION
2
A data plate is located on the side of the control box.
The voltage, wattage, serial number, wire size, and clearance specifications are on the data plate.
This information should be carefully read and understood before proceeding with the installation.
ELECTRICAL CONNECTION
The electrical connection must be made in accordance with local codes or in the absence of local
codes with NFPA No. 70 latest edition (in Canada use: CSA STD. C22.1)
The electrical service entrance is provided by a cord and plug located at the rear of the control
box.
The plug is a NEMA 50P. The receptacle must be supplied by the installer and is a NEMA
6-50R.
Supply wire size must be large enough to carry the amperage load for the number of Stock Pot
Ranges being installed.
The Stock Pot Range data plate is located on the side of the control box.
Wire size information can be found on the Stock Pot Range.
WARNING
ELECTRICAL GROUNDING INSTRUCTIONS
THIS APPLIANCE IS EQUIPPED WITH A 3-PRONG (GROUNDING) PLUG FOR YOUR
PROTECTION AGAINST SHOCK HAZARD AND MUST BE PLUGGED DIRECTLY INTO
A PROPERLY GROUNDED 3-PRONG RECEPTACLE.
DO NOT CUT OR REMOVE THIS GROUNDING PRONG FROM THE PLUG.
ELECTRICAL SPECIFICATION
MODEL VOLT WATT AMPS WIRE
SR-18-8-T208 8,000 38.5 8